Loading...
HomeMy WebLinkAboutDRC_2019-04-10_AgendaPacket http://www.facebook.com/planningatascadero @atownplanning Scan This QR Code with your smartphone to view DRC Website CITY OF ATASCADERO DESIGN REVIEW COMMITTEE AGENDA Committee Meeting Wednesday, April 10, 2019 2:00 P.M. City Hall 6500 Palma Avenue, Room 306 Atascadero, California CALL TO ORDER Roll Call: Chairperson Roberta Fonzi Committee Member Heather Newsom Committee Member Duane Anderson Committee Member Mark Dariz Committee Member Jamie Jones APPROVAL OF AGENDA PUBLIC COMMENT CONSENT CALENDAR 1. APPROVAL OF DRAFT MINUTES OF MARCH 6, 2019 City of Atascadero Design Review Committee Agenda Regular Meeting, April 10, 2019 Page 2 of 2 http://www.facebook.com/planningatascadero @atownplanning Scan This QR Code with your smartphone to view DRC Website DEVELOPMENT PROJECT REVIEW 2. DESIGN REVIEW OF 5730 EL CAMINO REAL Design review of a two-story mixed-use building in the downtown on a vacant infill site.  Recommendation: Review the conceptual renderings and provide recommendations for any potential design modifications. Make a recommendation to Planning Commission regarding approval of a 15% density bonus through the Conditional Use Permit process for providing exceptional design quality. (PRE19-0027) 3. DESIGN REVIEW OF 6490 EL CAMINO REAL Design review of an existing mono-pine cell tower to add 15-feet in height.  Recommendation: Review the conceptual renderings and provide recommendations for any potential design modifications. (AMND19-0012) 4. DESIGN REVIEW OF 9010 WEST FRONT ROAD Design review of proposed construction of two solar shade structures in the parking lot of the Holiday Inn Express.  Recommendation: Review the conceptual renderings and provide recommendations for any potential design modifications. (PRE19-0028) 5. DESIGN REVIEW OF 6925 EL CAMINO REAL Design review of proposed construction to infill a 1st floor space of a healthcare building that is currently used as a driveway.  Recommendation: Review the conceptual renderings and provide recommendations for any potential design modifications. (PRE19-0030) COMMITTEE MEMBER COMMENTS AND REPORTS DIRECTOR’S REPORT ADJOURNMENT The next DRC meeting is tentatively scheduled for Wednesday, April 24, 2019, at 2:00 p.m. Agendas, Minutes and Staff Reports are available online at www.atascadero.org under City Officials & Commissions, Design Review Committee. DRC Draft Minutes of 3/6/2019 Page 1 of 2 ITEM NUMBER: 1 DATE: 4-10-19 x CITY OF ATASCADERO DESIGN REVIEW COMMITTEE DRAFT MINUTES Regular Meeting – Wednesday, March 6, 2019 – 2:00 P.M. City Hall, 6500 Palma Avenue, Rm. 306, Atascadero, CA CALL TO ORDER – 2:04 p.m. Committee Member Dariz agreed to chair the meeting. Chairperson Dariz called the meeting to order at 2:04 p.m. ROLL CALL Present: Committee Member Duane Anderson Committee Member Mark Dariz Committee Member Heather Newsom Absent: Chairperson Roberta Fonzi (excused absence) Committee Member Jamie Jones (excused absence) Staff Present: Community Development Director, Phil Dunsmore Assistant Planner, Mariah Gasch Recording Secretary, Annette Manier Others Present: Shana Reiss, Reiss Design Studio APPROVAL OF AGENDA MOTION: By Committee Member Anderson and seconded by Committee Member Newsom to approve the Agenda. There was Committee consensus to approve the Agenda. PUBLIC COMMENT None. Chairperson Dariz closed the Public Comment period. CONSENT CALENDAR 1. APPROVAL OF DRAFT MINUTES OF JANUARY 23, 2019 1 DRC Draft Minutes of 3/6/2019 Page 2 of 2 ITEM NUMBER: 1 DATE: 4-10-19 MOTION: By Committee Member Anderson and seconded by Committee Member Newsom to approve the Consent Calendar. There was Committee consensus to approve the Consent Calendar. DEVELOPMENT PROJECT REVIEW 2. DESIGN REVIEW OF 8783 EL CAMINO REAL Guest House Grill is proposing to remodel the existing restaurant façade by constructing a new wooden awning that would be made up of painted or stained wood beams with concrete bases to be wrapped in stone veneer. The awning would be structurally independent and does not tie into the existing building structure.  Recommendation: Review the conceptual renderings and provide recommendations for any potential design modifications. (PRE19-0011) Assistant Planner Gasch presented the project and answered questions from the Committee. Applicant Shana Reiss gave a presentation on the project and stated that the project will provide a bigger space for customers to wait outside, and Guest House Gill will coordinate with existing tenants before work commences. PUBLIC COMMENT The following members of the public spoke during public comment: Shana Reiss. Chairperson Dariz closed the Public Comment period. This item was approved by the Committee. Staff and the applicant will work together on bird protection and rain gutters. COMMITTEE MEMBER COMMENTS AND REPORTS None DIRECTOR’S REPORT Director Dunsmore gave an update on projects within the City. Director Dunsmore stated that the meeting for March 13, 2019, will be cancelled. The next DRC meeting is tentatively scheduled for Wednesday, March 27, 2019. ADJOURNMENT– 2:20 p.m. The next regular meeting of the DRC is tentatively scheduled for March 27, 2019, at 2:00 p.m. MINUTES PREPARED BY: _________________________________________________ Annette Manier, Recording Secretary/Administrative Assistant 2 ITEM 2 5730 El Camino Real, Colony Lofts PRE 19-0027 / Zappas ADDITIONAL INFORMATION MAY BE OBTAINED BY CONTACTING THE ATASCADERO COMMUNITY DEVELOPMENT DEPARTMENT AT http://www.atascadero.org 6500 PALMA AVENUE | ATASCADERO, CA 93422 | (805) 461-5000 Atascadero Design Review Committee Staff Report – Community Development Department Downtown Mixed-Use, Colony Lofts 5730 El Camino Real MEETING DATE PROJECT PLANNER APPLICANT CONTACT PLN NO. 4/10/19 Callie Taylor Senior Planner Max Zappas PRE19-0027 RECOMMENDATION Staff Recommends to the DRC: 1. Review the conceptual renderings and provide recommendations for any potential design modifications. 2. Recommend the Planning Commission approve a 15% density bonus through the Conditional Use Permit process for providing exceptionally high design quality. PROJECT ADDRESS GENERAL PLAN DESIGNATION ZONING DISTRICT ASSESOR PARCEL NUMBER(S) SITE AREA 5730 El Camino Real, Atascadero, CA 93422 Downtown (D) Downtown Commercial (DC) 030-818-055 0.202 acres PROJECT DESCRIPTION A new mixed-use building is proposed on a vacant infill lot at 5730 El Camino Real in the downtown. The building includes 2,500 sq. ft. of commercial space on the ground floor facing El Camino Real, and five (5) residential units. Four (4) units are proposed on second floor, and one (1) accessible unit is proposed on the ground floor behind the commercial. The project includes a request for a 15% density bonus for providing exceptionally high design quality. ENVIRONMENTAL DETERMINATION The City of Atascadero’s environmental review process incorporates the requirements in implementing the California Environmental Quality Act. Persons, agencies, or organizations interested in obtaining more information regarding the environmental should contact the Community Development Department. ☐ EIR / MND / ND / Statutory Exemption to be circulated ☐ Prior CEQA Review CEQA # ____________ Certified: _________ ☒ Cat. Exemption Class____32______ CEQA Guidelines § 15332 ☐ No Project - § 15268 Ministerial Project 3 ITEM 2 5730 El Camino Real, Colony Lofts PRE 19-0027 / Zappas Design Review Committee | City of Atascadero | www.atascadero.org | fb.me/planningatascadero DISCUSSION: Project Description / Summary A new mixed-use building is proposed on a vacant infill lot at 5730 El Camino Real in the downtown, next door to Bru Coffeehouse and A-1 Mobility. The ground floor proposes a 2,500 square foot commercial space on El Camino Real. A covered front patio is located at the entrance and can be utilized for outdoor dining. Behind the commercial space, one (1) accessible residential unit is proposed on the ground floor at 1,544 square feet with two bedrooms plus an office. Four (4) 2-bedroom residential units are proposed on the second floor, at approximately 1200 square feet each. DRC DISCUSSION ITEMS: Site Design and Floor Plan Layout The site plan is well thought out to efficiently provide all code required amenities for the residential units. Each residential unit is provided a private outdoor patio or balcony, and there is laundry in each unit. Five (5) single car garage spaces are located at the back of the building on the ground floor and are accessed from the alley adjacent to Highway 101. Tandem parking is provided in front of the garages so that each unit has two parking spaces, and one guest space is provided on site. A screened trash enclosure is located next to alley at the back of the site. The residential units are accessed by a 5- foot walkway along the south side of building, which is secured by private gates at each side of the lot. Separation between the new building and the adjacent downtown buildings also allows light and air to enter the sides of the residential units so that bedrooms can be provided towards the middle of the building. The Atascadero Zoning Ordinance permits residential units in the Downtown Commercial zone only when located on the second or third floors ; however, there is a provision in AMC Section 9-3.330 which allows an exception for accessible units. The code section states that if a project is required to provide a unit in compliance with the Americans with Disabilities Act, the accessible unit may be located on a first floor. A first floor unit shall be located in a non-storefront location. California Building Code (Section 1102A.3) requires that buildings with three (3) or more for rent dwelling units, or four (4) or more condominium units, shall provide 10% of the units as accessible units. The project proposes five (5) multifamily residential units, and therefore one unit must be accessible. This can be provided by either installing an elevator to the upper floors, or through the provision identified above which allows the required unit to be located on the ground floor behind the commercial. The project proposal is consistent with the accessible standards of the CBC and the zoning regulations of the City’s Municipal Code. 4 ITEM 2 5730 El Camino Real, Colony Lofts PRE 19-0027 / Zappas Design Review Committee | City of Atascadero | www.atascadero.org | fb.me/planningatascadero Architecture and Materials The proposed building at 5730 El Camino Real is designed in accordance with the Downtown Design Guidelines and the City’s Appearance Review Manual. The building is well articulated with architectural design details to complement the surrounding historic downtown buildings. The architectural detailing and materials on the f ront façade are high quality and traditional, yet unique to this new building. The brick proposed on the front façade and the color scheme compliment nearby historic buildings, as well as the Carlton Hotel and the future La Plaza project. The lower wainscot molding on the front columns is cast concrete, and upper trim and cornices are to be made of foam trim. The plans specify hand troweled plaster to achieve a flat exterior finish consistent with historic structures. The facades are balanced with careful consideration to window and door placement. The large aluminum storefront windows facing El Camino Real are scaled appropriately to the building and provide a traditional downtown commercial façade. An appropriate area is designated across the front for high quality signage. The second floor residential units include balconies overlooking El Camino Real, and are adorned with metal railings and symmetrically placed windows and doors. Side and rear elevations are not very visible; however, still incorporate basic architectural detailing such as the roof cornice, arched brick above the windows and garages, and rear balconies. Utilities and trash are screened. Solid gates at the four corners of the building provide security for the residential units which access the side walkways. Density Bonus Based on the 0.202 acre lot size of the subject site, and the 20 unit per acre maximum density allowed in the Downtown Commercial zone, the site is permitted up to four (4) units. General Plan Policy 2.1, Program 2 allows a 15% density bonus for exceptionally high design quality, which can be approved through the Conditional Use Permit process. A 15% density bonus would provide 4.65 units, which is rounded up to five (5) units. The proposed project is exceptionally well designed and would be an asset to the downtown. City staff recommends approval of the density bonus based on the high quality design, and as provided by General Plan Policy 2.1. Conditions of approval had been included in the draft DRC Action Form to ensure that the high quality materials and design details identified on the preliminary plans are implemented during construction. Use of metal or wood storefronts, windows and doors, rather than a modern vinyl, is imperative to ensure historic compatibility for the new structure. The hand troweled plaster, brick veneer, and other details will be verified at time of building permits and during construction. These high quality materials add to the construction costs, and are often eliminated or modified at the construction phase to cut costs. However, when a density bonus is awarded for providing high quality design, it is critical to maintain a high level of quality throughout the project. 5 ITEM 2 5730 El Camino Real, Colony Lofts PRE 19-0027 / Zappas Design Review Committee | City of Atascadero | www.atascadero.org | fb.me/planningatascadero Summary The addition of an infill mixed-use building at this location enhances the downtown and fulfils several goals and policies of the General Plan and the Downtown Revitalization Plan. Economic development is strengthened by a new high quality commercial space in the heart of the downtown. The project provides streetscape appeal, improved retail and restaurant opportunities, and additional multifamily housing within the downtown. The project is consistent with the Downtown Design Guidelines and the Appearance Review Manual. Staff recommends a 15% density bonus be approved through the Conditional Use Permit process for providing exceptionally high quality archit ecture and design. ATTACHMENTS: Attachment 1: Zoning Map Attachment 2: Aerial Photo vacant lot Attachment 3: DRC Action Form Attachment 4: Proposed Preliminary Design Plans 6 ITEM 2 5730 El Camino Real, Colony Lofts PRE 19-0027 / Zappas Design Review Committee | City of Atascadero | www.atascadero.org | fb.me/planningatascadero Attachment 1: Zoning Map PRE 19-0027 Subject Site 5730 El Camino Real 7 ITEM 2 5730 El Camino Real, Colony Lofts PRE 19-0027 / Zappas Design Review Committee | City of Atascadero | www.atascadero.org | fb.me/planningatascadero Attachment 2: Aerial Photo vacant lot PRE 19-0027 Subject Site 5730 El Camino Real 8 ITEM 2 5730 El Camino Real, Colony Lofts PRE 19-0027 / Zappas Design Review Committee | City of Atascadero | www.atascadero.org | fb.me/planningatascadero Attachment 3: DRC Action Form PRE 19-0027 Conditions & Recommendations: 1. Design of the facades and site shall be in substantial conformance with the project plans dated March 5, 2019, by Studio Design Group. 2. The high quality materials and design details identified on the preliminary plans shall be implemented during construction. Windows, doors, and the commercial storefront shall be metal/aluminum or wood, not vinyl. Stucco shall be hand troweled plaster. Lower floor wainscot moldings shall be concrete or similar high quality material. Foam trim may be used on upper floors. 3. Project shall comply with all standards and code requirements of the Municipal Code and the California Building Code, including but not limited to the sign ordinance, landscape and fencing standards, lighting standards, multifamily development standards, and the Downtown Commercial zoning district standards. Approval of the preliminary design shall not constitute any waiver of code requirements. 4. Landscape shall be provided within large planter boxes and large pots as identified on the site plan. Drip irrigation with automatic timer controllers shall be installed to ensure vegetation survives. 5. Site density shall conform to Municipal Code and General Plan standards. A Conditional Use Permit shall be processed in accordance with General Plan Policy 2.1, Program 2 for the 15% density bonus requested for exceptionally high design quality. An application and fees for the CUP shall be submitted, and the project will be reviewed by the Planning Commission. 9 ITEM 2 5730 El Camino Real, Colony Lofts PRE 19-0027 / Zappas Design Review Committee | City of Atascadero | www.atascadero.org | fb.me/planningatascadero Attachment 4: Proposed Preliminary Design Plans (Dated March 5, 2019) PRE 19-0027 See Attached 10 11 EXIST .07" TREE NEW TRE E CL CL875.95 FS876.71 FS879.03 FS879.24 FSCONFORM1.5%3.9%879.14 FS876.45 FS1.5%878.00 FS1%5% MAX.878.46 FS878.50 FS5.0%878.46 FS876.76 FS876.65 FS5.0% MAX 875.95 FS6" CONCRETE CURB 878.56 FS880.08 FS880.03 FS1%880.42 FSCONFORM880.13 FS5% MAX. 875 876 877 878 879 876877 876877878 878877878879 879880 880879EX. 6" SSEX. 2" PE GAS MAINEX. EPASPHALT OVERLAY TO BE INSTALLED OVER 1/2 THE STREET (ALLEY) WIDTH PLUS 10' IN ACCORDANCE WITH MUNICIPAL CODE SECTION 9-4.160 EX. JP S EX. HIGHWAY FENCE LINEEX. 4" PEM GASEX. 10" HCP GASEX. FENCE LINEEL CAMINO REALMATCH EXISTING GRADE @ ASPHALT82.00' N58°54'25"W30.00' S31°09'54"W 15.00' S58°54'25"E95.00' S31°09'54"W 125.00' N31°09'54"E 67.00' S58°54'25"E880 879.92 FSCONFORM879.51 FSCONFORM879.14 FSCONFORM879.29 TCEXIST879.98 TCEXIST2% MAX. 2% MAX. 2% MAX.DRAIN1 SITE PLAN REFERENCE NOTES 1.SITE NOTES FF 878.6'FF 878.6' FF 879.94' FF 878.50' FF 877.16' FF 876.74' FF 876.32' FF 875.90' FF 877.58'10'-0"4'-0"10'-8"TYP.18'-0"12'-0"5'-0"10'-8"TYP.18'-0" TYP. 20'-0" TYP.8'-0"TYP.5'-3"5'-9"9'-4"A0El Camino Real Mixed Use 5730 El Camino, Atascadero , CA These drawings are instruments of service and are the property of STUDIO DESIGN GROUP ARCHITECTS, INC. All designs and other information on the drawings are for use on the specified project and shall not be used without the expressed written consent of STUDIO DESIGN GROUP ARCHITECTS, INC. 3/1/19SITE PLAN EXHIBIT 0 10 20 12 A1El Camino Real Mixed Use 5730 El Camino, Atascadero , CA These drawings are instruments of service and are the property of STUDIO DESIGN GROUP ARCHITECTS, INC. All designs and other information on the drawings are for use on the specified project and shall not be used without the expressed written consent of STUDIO DESIGN GROUP ARCHITECTS, INC. CL CL875.95 FS876.71 FS879.03 FS879.24 FSCONFORM1.5%3.9%879.14 FS876.45 FS1.5%878.00 FS1%5% MAX.878.46 FS878.50 FS5.0%878.46 FS876.76 FS876.65 FS5.0% MAX 875.95 FS6" CONCRETE CURB 878.56 FS880.08 FS880.03 FS1%880.42 FSCONFORM880.13 FS5% MAX.MATCH EXISTING GRADE @ ASPHALT879.92 FSCONFORM879.51 FSCONFORM879.14 FSCONFORM879.29 TCEXIST879.98 TCEXIST2% MAX. 2% MAX. 2% MAX.DRAIN2nd F.F. = 894.94' R DW FP P W D KING76x80LIN. +9' CLG. +9' CLG. +8' CLG.KING76x80RP FPWDDWKING76x80RPFPWDDW PATIO PATIO PATIO PATIO R DW FP P W DKING76x80 LIN. +9' CLG. +9' CLG. +8' CLG. OPEN TO BELOW B STORAGE C STORAGE E STORAGE D STORAGE R DW FP P W D KING76x80LIN. +9' CLG. +9' CLG. +8' CLG. R DW FP P W D KING76x80LIN. +9' CLG. +9' CLG. +8' CLG. 2nd F.F. = 891.44' UNIT B LIVING ROOM UNIT B KITCHEN UNIT B POWDER UNIT B BR 1UNIT B BR 2 UNIT B BATHROOM UNIT C LIVING ROOM UNIT C KITCHEN UNIT C POWDER UNIT C BR 1 UNIT C BR 2 UNIT C BATHROOM UNIT D LIVING ROOM UNIT D KITCHEN UNIT D POWDER UNIT D BR 1 UNIT D BR 2 UNIT D BATHROOM UNIT E LIVING ROOM UNIT E KITCHEN UNIT E POWDER UNIT E BR 1 UNIT E BR 2 UNIT E BATHROOM DEMO PLAN REFERENCE NOTES 1.EXISTING WALL TO REMAIN. 1 EXISTING WALL WALL LEGEND 1 DEMO PLAN 2 REF NOTES 1.NOTE EXISTING PLAN 2EXIST .07" TREE NEW TRE E CL CL875.95 FS876.71 FS879.03 FS879.24 FSCONFORM1.5%3.9%879.14 FS876.45 FS1.5%878.00 FS1%5% MAX.878.46 FS878.50 FS5.0%878.46 FS876.76 FS876.65 FS5.0% MAX 875.95 FS6" CONCRETE CURB 878.56 FS880.08 FS880.03 FS1%880.42 FSCONFORM880.13 FS5% MAX.MATCH EXISTING GRADE @ ASPHALT879.92 FSCONFORM879.51 FSCONFORM879.14 FSCONFORM879.29 TCEXIST879.98 TCEXIST2% MAX. 2% MAX. 2% MAX.DRAINPRDW NEW 3 1/2" FRAMED WALL NEW 5 1/2" FRAMED WALL EXISTING WALL NEW MASONRY WALL WALL LEGEND NEW MASONRY WALL 2 ROOMROOM UNIT A GARAGE UNIT B GARAGE UNIT C GARAGE UNIT D GARAGE UNIT E GARAGE RETAIL 1st F.F. = 879.94' ELECTRICAL FIRE RISER +7'-6" CLG. +8'-0" CLG. +10' CLG. +9' CLG. +9' CLG. +9' CLG. OPEN TO ABOVE PATIO OPEN TO ABOVE W/ TRELLIS W D+7'-6" CLG. +8'-0" CLG. +10' CLG. APARTMENT 1st F.F. = 878.50' OPEN TO ABOVE FP PATIO OPEN TO ABOVE W/ TRELLIS KING76x80+8'-0" CLG. +9' CLG. +9' CLG. +7'-6" CLG.+8'-0" CLG. +9' CLG. +9' CLG. +9' CLG. OPEN TO ABOVE PATIO OPEN TO ABOVE W/ TRELLIS +10' CLG. PATIO W/ 2ND STORY ABOVE PATIO W/ 2ND STORY ABOVE +10' CLG. +9' CLG. +10' CLG.UNISEXRESTROOMATTIC ACCESS 36"-96"STORAGE CABINETSATTIC ACCESS 36"-96"STORAGE CABINETSATTIC ACCESS 36"-96"STORAGE CABINETS36"-96"STORAGE CABINETS36"-96"STORAGE CABINETSATTIC ACCESS ATTIC ACCESS UNISEXRESTROOMUNIT A LIVING ROOM UNIT A KITCHEN UNIT A MASTER BATH UNIT A BATH UNIT A MASTER BR UNIT A BR 2 UNIT A OFFICE RETAIL TRASH FF 878.6 FF 878.6 +7'-6" CLG. +8'-0" CLG. FLOOR PLAN REFERENCE NOTES 1.NEW WALL. 1 0 8 163/1/191ST FLOOR PLAN 13 A2El Camino Real Mixed Use 5730 El Camino, Atascadero , CA These drawings are instruments of service and are the property of STUDIO DESIGN GROUP ARCHITECTS, INC. All designs and other information on the drawings are for use on the specified project and shall not be used without the expressed written consent of STUDIO DESIGN GROUP ARCHITECTS, INC. CL CL875.95 FS876.71 FS879.03 FS879.24 FSCONFORM1.5%3.9%879.14 FS876.45 FS1.5%878.00 FS1%5% MAX.878.46 FS878.50 FS5.0%878.46 FS876.76 FS876.65 FS5.0% MAX 875.95 FS6" CONCRETE CURB 878.56 FS880.08 FS880.03 FS1%880.42 FSCONFORM880.13 FS5% MAX.MATCH EXISTING GRADE @ ASPHALT879.92 FSCONFORM879.51 FSCONFORM879.14 FSCONFORM879.29 TCEXIST879.98 TCEXIST2% MAX. 2% MAX. 2% MAX.DRAIN2nd F.F. = 894.94' R DW FP P W D KING76x80LIN. +9' CLG. +9' CLG. +8' CLG.KING76x80RP FPWDDWKING76x80RPFPWDDW PATIO PATIO PATIO PATIO R DW FP P W DKING76x80 LIN. +9' CLG. +9' CLG. +8' CLG. OPEN TO BELOW B STORAGE C STORAGE E STORAGE D STORAGE R DW FP P W D KING76x80LIN. +9' CLG. +9' CLG. +8' CLG. R DW FP P W D KING76x80LIN. +9' CLG. +9' CLG. +8' CLG. 2nd F.F. = 891.44' UNIT B LIVING ROOM UNIT B KITCHEN UNIT B POWDER UNIT B BR 1UNIT B BR 2 UNIT B BATHROOM UNIT C LIVING ROOM UNIT C KITCHEN UNIT C POWDER UNIT C BR 1 UNIT C BR 2 UNIT C BATHROOM UNIT D LIVING ROOM UNIT D KITCHEN UNIT D POWDER UNIT D BR 1 UNIT D BR 2 UNIT D BATHROOM UNIT E LIVING ROOM UNIT E KITCHEN UNIT E POWDER UNIT E BR 1 UNIT E BR 2 UNIT E BATHROOM DEMO PLAN REFERENCE NOTES 1.EXISTING WALL TO REMAIN. 1 EXISTING WALL WALL LEGEND 1 DEMO PLAN 2 REF NOTES 1.NOTE EXISTING PLAN 2 0 8 163/1/192ND FLOOR PLAN 14 15 16 4'-5"1%878.46 FS878.50 FS5.0%878.46 FS876.76 FS878.56 FS20'-11 1/2"23'-4"10'-0"PDWWD+8'-0" CLG.APARTMENT1st F.F. =878.50'FPKING76x80ATTICACCESS36"-96"STORAGE CABINETSATTICACCESS36"-96"STORAGE CABINETSATTICACCESS36"-96"STORAGE CABINETS36"-96"STORAGE CABINETS36"-96"STORAGE CABINETSATTICACCESSATTICACCESSF.F. =887.00'MEZZANINESTORAGE / MECH.2nd F.F. =894.94'BSTORAGECSTORAGEESTORAGEDSTORAGERDWFPPWDKING76x805'-0"5'-0"LIN.4'-1"+9' CLG.+9' CLG.+8' CLG.RDWFPPWDKING76x805'-0"5'-0"LIN.4'-1"+9' CLG.+9' CLG.+8' CLG.2nd F.F. =891.44'3'-0"6'-10"20'-6"28'-0"28'-0"11'-4"12'-6"11'-3"5'-11"6'-2"5'-7"5'-8"20'-11 1/2"10'-0"10'-0"6'-2"11'-6"5'-8"20'-11 1/2"106'-8"10'-0"5'-11"6'-2"5'-7"FF2: 894.94' FF1: 879.94' GARAGE COMMERCIAL SPACE UPSTAIRS UNIT UPSTAIRS UNIT ACCESSIBLE UNIT 6'-10" +887.00 LANDING +879.94 RETAILWD +887.33 FF MEZ . +878.50 APARTMENT7'-8"+894.94 FF2 FRONT STORAGE +887.00 MEZZANINE STORAGE +891.44 FF2 REAR 6'-9"A5El Camino Real Mixed Use 5730 El Camino, Atascadero , CA These drawings are instruments of service and are the property of STUDIO DESIGN GROUP ARCHITECTS, INC. All designs and other information on the drawings are for use on the specified project and shall not be used without the expressed written consent of STUDIO DESIGN GROUP ARCHITECTS, INC. VERTICAL CIRCULATION SECTION LONGITUDINAL SECTION MEZZANINE STORAGE / MECHANICAL F.F. = 887.00' MEZZANINE STORAGE / MECH. 17 5 1/4"9"2 3/4"4"2"4 1/4"1" FOAM TRIM - A SURFACE MOUNTED FOAM TRIM W/ STUCCO COLOR COAT FINISH 1/4"11" FOAM TRIM - A 1'-3 3/4"11" 5"3"3"4"5"6"3/4"FOAM TRIM - B SURFACE MOUNTED FOAM TRIM W/ STUCCO COLOR COAT FINISH FOAM TRIM - C SURFACE MOUNTED FOAM TRIM W/ STUCCO COLOR COAT FINISH 3"6"1 3/4"4"1"2"1/4"FOAM TRIM - C FOAM TRIM - D 2"1" FOAM TRIM - E SURFACE MOUNTED FOAM TRIM W/ STUCCO COLOR COAT FINISH 1'-1 1/4"9 1/4"3/4"6"3"3"5 1/4"3 1/2"4"FOAM TRIM - E FOAM TRIM - F SURFACE MOUNTED FOAM TRIM W/ STUCCO COLOR COAT FINISH 9"5"1 3/4"4"3"1"1"2"1"1/4"FOAM TRIM - F FOAM TRIM - CFOAM TRIM - DENTIL SURFACE MOUNTED FOAM TRIM W/ STUCCO COLOR COAT FINISH 6"3"4" EQUALLY SPACED AS INDICATED ON ELEVATION 1'-0"1'-0"3"X3" FLEUR DE LIS DALTILE "EARTHEN ART" TILES COLOR: "MARTINI OLIVE" NATURAL GREY GROUT 6"X6" AVIGNON DECO DALTILE "EARTHEN ART" TILES COLOR: "MARTINI OLIVE" NATURAL GREY GROUT ACCENT TILE DETAIL A6El Camino Real Mixed Use 5730 El Camino, Atascadero , CA These drawings are instruments of service and are the property of STUDIO DESIGN GROUP ARCHITECTS, INC. All designs and other information on the drawings are for use on the specified project and shall not be used without the expressed written consent of STUDIO DESIGN GROUP ARCHITECTS, INC.18 ITEM 3 Monopine Height Extension AMND19-012 / American Tower Corporation ADDITIONAL INFORMATION MAY BE OBTAINED BY CONTACTING THE ATASCADERO COMMUNITY DEVELOPMENT DEPARTMENT AT http://www.atascadero.org 6500 PALMA AVENUE | ATASCADERO, CA 93422 | (805) 461-5000 Atascadero Design Review Committee Staff Report – Community Development Department Downtown Cell Tower Height Extension MEETING DATE PROJECT PLANNER APPLICANT CONTACT PLN NO. 4/10/19 Kelly Gleason American Tower Corporation AMND 19-0012 PROJECT ADDRESS GENERAL PLAN DESIGNATION ZONING DISTRICT ASSESOR PARCEL NUMBER(S) SITE AREA 6490 El Camino Real Downtown (D) Downtown Commercial (DC) 030-191-017 Approximately 1,250sf lease area RECOMMENDATION Staff Requests the Design Review Committee: 1. Review the proposed height extension for an existing cell tower (faux pine tree) and direct the applicant to make any modifications to the design as necessary. PROJECT DESCRIPTION The applicant proposes to add 15-feet in height to the existing cell tower. This extension is necessary in order to accommodate the La Plaza project development. The project also includes a new perimeter wall and gate. ENVIRONMENTAL DETERMINATION The City of Atascadero’s environmental review process incorporates the requirements in implementing the California Environmental Quality Act. Persons, agencies, or organizations interested in obtaining more information regarding the environmental should contact the Community Development Department. ☐ EIR / MND / ND / Statutory Exemption to be circulated ☐ Prior CEQA Review: ☒ Categorical Exemption: § 15301 Existing Facilities ☐ No Project - § 15268 Ministerial Project 19 ITEM 3 Monopine Height Extension AMND 19-0012 / American Tower Design Review Committee | City of Atascadero | www.atascadero.org | fb.me/planningatascadero SPECIAL DEVELOPMENT PLAN STANDARDS ☐ Downtown Revitalization Plan ☐ Specific Plan ______________________________________________________ ☐ Planned Development Overlay____________________________________________ USE CLASSIFICATION ALLOWED OR CONDITIONALLY ALLOWED USE STRUCTURE 50-YEARS OLD OR GREATER JURISDICTIONAL CREEK Telecommunication Facility ☐ Allowed ☒ Conditional ☐ Yes ☒ No ☐ Atascadero ☐ Graves ☐ Paloma ☐ Boulder ☐ Other ☒ N/A ☐ Registered Building ☐ No historical significance EXISTING USES Mono-pine cell tower SURROUNDING ZONING DISTRICTS AND USES North: South: East: West: Downtown Commercial Downtown Commercial Downtown Commercial Hwy 101 AVERAGE SLOPE VEGETATION <10% None DENSITY / FLOOR AREA RATIO ☐ RSF-X / LSF-X: 4 units per acre ☐ RMF-10: 2-10 units per acre ☐ RMF-20: 20-24 units per acre ☐ CP/CR/CS/CN/DO/DC: Max 20 units per acre ☒ Other: N/A ☐ State Density Bonus Requested ☐ Density Bonus for High Quality Architecture ☐ City Inclusionary Housing Density Bonus ☐ Inclusionary Housing Required ☐ Floor Area Ratio (FAR) (Total square foot of building compared to the size of the property) ZONING ORDINANCE / MUNICIPAL CODE STANDARDS / CITY POLICIES City Standards Meets Requirements Exception Requested Setback standards (AMC 9-4.103) ☒Yes ☐No Height Standards (AMC 9-4.111) ☐Yes ☒No Landscaping (AMC 9-4.124) ☒Yes ☐No Fencing Standards (AMC 9-4.128) ☒Yes ☐No Lighting Standards (AMC 9-4.137) ☒Yes ☐No 20 ITEM 3 Monopine Height Extension AMND 19-0012 / American Tower Design Review Committee | City of Atascadero | www.atascadero.org | fb.me/planningatascadero Water Efficient Landscaping (AMC Title 8, Chapter 10 ) ☒Yes ☐No Use Classification Standards: “Telecommunications Facility” ☒Yes ☐No ADVISORY BODIES / OUTSIDE AGENCIES THAT REQUIRE REVIEW OF PROPOSED PROJECT: ☒ Native American Tribes ☐ Atascadero Mutual Water Company (AMWC) ☐ Caltrans District 5 ☐ Regional Water Quality Control Board (RWQCB) ☐ Dept. of Fish & Wildlife (DFW) ☐ SLO Air Pollution Control (APCD) ☐ SLO County ☐ _____________________________ ☐ _____________________________ ☐ _____________________________ APPROVAL PROCESS ☒ DRC ☐ AUP ☒ PC ☐ CC Aerial Map DISCUSSION: Project History A 63-foot high cell tower was established at the subject location in 1997 with a conditional use permit. (CUP 97-009). In 2002 an amendment to the use permit was approved to allow for co- location and to convert the pole into a stealth pole to resemble a pine tree (the term “monopine” is used by wireless companies to describe a faux pine tree cell tower). The request was approved and the monopine was installed shortly after. In 2017, the La Plaza project was approved by the City Council. The project encompasses this site and multiple properties to the North. Following approval of the project the applicant team was made aware that American Tower retained an easement for Radio Frequency (RF) transmission through the property and that the easement prevented construction from impeding the easement rights . Following many months of discussion and negotiation, American Tower concluded that the 21 ITEM 3 Monopine Height Extension AMND 19-0012 / American Tower Design Review Committee | City of Atascadero | www.atascadero.org | fb.me/planningatascadero development may proceed if the tower is raised to allow the wireless facility to clear the height of the building. The La Plaza project features a three story mixed use building with a tower feature that extends above the third floor. In order to maintain cellular signal range, the applicant is requesting to extend the monopine height by 15-feet. Project Description / Summary The cell facility extension would include the placement of additional faux trunk and branches to extend the carrier antennas to a height of 70-feet. The tower would extend to a total height of 80-feet with faux branching extending to a maximum total height of 86-feet. The proposal also includes replacement of the existing equipment enclosure material. Site Plan Analysis Tower Height. The applicant is proposing to increase the height of the monopine by 15- feet to provide a total height of 80-feet for the tower and 86-feet for the additional faux pine screening material (faux tree branches). The maximum height in the Downtown Commercial Zoning District for this type of facility is 55-feet. The original CUP approval in 1997 approved a height exception to allow the tower to be up to 65 -feet. The 2002 CUP amendment maintained tower height but allowed additional height for the faux pine material. The increased height is needed to accommodate the taller La Plaza mixed-use development. The previous commercial building on the site was a single -story building, however; the La Plaza development is approved as a three story structure with a tower feature that extends to a fourth floor. The height of the La Plaza building is 45 -feet with the tower extending to just above 60-feet. The additional cell facility height will allow the co-located carriers to maintain their existing cell signal range. A condition is proposed to 22 ITEM 3 Monopine Height Extension AMND 19-0012 / American Tower Design Review Committee | City of Atascadero | www.atascadero.org | fb.me/planningatascadero require the replacement of any existing faux branches that are faded or in a state of disrepair to ensure that there will be no visible color difference between the new and existing pine structure. PROPOSED 23 ITEM 3 Monopine Height Extension AMND 19-0012 / American Tower Design Review Committee | City of Atascadero | www.atascadero.org | fb.me/planningatascadero Equipment Enclosure. The existing equipment enclosure is a combination of wood and chain-link fencing. The proposal includes the construction of a new enclosure utilizing concreate block and steel gates. Staff has added a condition that dark colored, split - faced block be used and that brick pilasters be added to the corners facing the La Plaza building to provide architectural consistency. Landscaping of the enclosure will be completed with the La Plaza development. DRC DISCUSSION ITEMS: 1. Tower Height. 2. Equipment Enclosure. ATTACHMENTS: 1. Notice of Action 2. Conceptual Plans 24 ITEM 3 Monopine Height Extension AMND 19-0012 / American Tower Design Review Committee | City of Atascadero | www.atascadero.org | fb.me/planningatascadero Attachment 1: Notice of Action AMND19-0012 DRC NOTICE OF ACTION Conditions of Approval: 1. All existing faux pine material shall be replaced as needed to ensure color and quality compatibility with the newly added pine material. 2. Equipment enclosure shall be constructed of dark color split face block with brick clad pilasters at the corners facing the La Plaza buildings and parking area. 3. The facility shall be maintained in perpetuity in a manner consistent with the CUP approval, including continued upkeep and maintenance of the pine material and replacement of such should it become faded or in a state of disrepair. Action/ Decision Summary: To be recorded at meeting conclusion Meeting Date: April 10, 2019 Project Planner: Kelly Gleason Senior Planner 25 ITEM 3 Monopine Height Extension AMND 19-0012 / American Tower Design Review Committee | City of Atascadero | www.atascadero.org | fb.me/planningatascadero Attachment 2: Conceptual Plans AMND 19-0012 26 ITEM 3 Monopine Height Extension AMND 19-0012 / American Tower Design Review Committee | City of Atascadero | www.atascadero.org | fb.me/planningatascadero 27 ITEM 3 Monopine Height Extension AMND 19-0012 / American Tower Design Review Committee | City of Atascadero | www.atascadero.org | fb.me/planningatascadero 28 ITEM 3 Monopine Height Extension AMND 19-0012 / American Tower Design Review Committee | City of Atascadero | www.atascadero.org | fb.me/planningatascadero 29 ITEM 4 Holiday Inn Solar Canopies PRE 19-0028 / Holland ADDITIONAL INFORMATION MAY BE OBTAINED BY CONTACTING THE ATASCADERO COMMUNITY DEVELOPMENT DEPARTMENT AT http://www.atascadero.org 6500 PALMA AVENUE | ATASCADERO, CA 93422 | (805) 461-5000 Atascadero Design Review Committee Staff Report – Community Development Department Holiday Inn Solar Structures MEETING DATE PROJECT PLANNER APPLICANT CONTACT PLN NO. 4/10/2019 Mariah Gasch Assistant Planner Jerry Holland (owner) Charlie Schluter PRE 19-0028 RECOMMENDATION Staff Recommends to the DRC: Review the proposed project and provide recommendations for any potential design modifications. PROJECT ADDRESS GENERAL PLAN DESIGNATION ZONING DISTRICT ASSESOR PARCEL NUMBER(S) SITE AREA 9010 West Front Road Atascadero, CA 93422 General Commercial (GC) Commercial Retail (CR) / Planned Development Overlay Zone No. 23 056-131-024 1.72-acres PROJECT DESCRIPTION The applicant is proposing to install two solar shade structures within the Holiday Inn Express parking lot. The structures will be located adjacent to north and south property lines. ENVIRONMENTAL DETERMINATION The City of Atascadero’s environmental review process incorporates the requirements in implementing the California Environmental Quality Act. Persons, agencies, or organizations interested in obtaining more information regarding the environmental should contact the Community Development Department. ☐ EIR / MND / ND / Statutory Exemption to be circulated ☐ Prior CEQA Review CEQA # ____________ Certified: _________ ☒ Cat. Exemption Class ____3_______ CEQA Guidelines § 15303 ☐ No Project - § 15268 Ministerial Project 30 ITEM 4 Holiday Inn Solar Canopies PRE 19-0030 / Holland Design Review Committee | City of Atascadero | www.atascadero.org | fb.me/planningatascadero DISCUSSION: Project Description / Summary The subject property is a freeway facing parcel located on West Front Road. The parcel is within the Commercial Retail Zoning district (CR) but is also governed by Planned Development (PD) Overlay Zone No. 19. The PD covers the hotel site, the 3 restaurant pads (Marston’s, Starbucks, and Jack-in-the-Box) and the newer residential sites to the west. The site is neighbored on the west by multi -family properties and by commercial properties to the north and south. The applicant is proposing the installation of two solar shade structures within the Holiday Inn parking lot. The structures are proposed to be built nearly parallel to the north and south property lines. The structure at the north property line will cover 13 parking spaces and be approximately 125 feet long by 19 feet wide. The structure at the south of the property will cover 4 parking spaces and be approximately 46 feet long by 19 feet wide. The height of the structure will be dependent on the angle at which the solar panels must be placed. The plans submitted show a height of approximately 20 feet which includes a clearance height maximum of 18 feet with an additional two feet to accommodate the cross beams and solar modules. The maximum height that engineering allows is approximately 22 feet. The solar system is not reflected in the master plan of development for the property. However, staff does not expect them to visually change the development’s compatibility with the surrounding community. However, the addition of shade for parking spaces combined with the opportunity to produce solar energy is a factor in considering the placement of the structures. Similar structures have been placed at many of the school sites around the County. DRC DISCUSSION ITEMS: Color The plans submitted do not show a proposed color for the two new solar structures. However, the applicant has suggested painting them a tan color similar to the color seen on the surrounding buildings. Staff Recommendation Staff recommends that the applicant paint the new structures a darker brown color to match the frame of the monument sign outside of the hotel. Design The proposed structures would be made of steel. The structure at the north property line will be approximately 125 feet long by 19 feet wide. The structure at the south of the 31 ITEM 4 Holiday Inn Solar Canopies PRE 19-0030 / Holland Design Review Committee | City of Atascadero | www.atascadero.org | fb.me/planningatascadero property will be approximately 46 feet long by 19 feet wide. The structures’ minimum clearance height would be 16 feet high with a maximum clearance height of approximately 18 feet. Including the solar panels themselves, the maximum height of the structure would be approximately 22 feet. Staff Recommendation Staff has no recommendations. The maximum height is within the height limitations for the zoning district. ATTACHMENTS: Attachment 1: Aerial View Attachment 2: Site Pictures Attachment 3: Site Plan Attachment 4: North Structure Elevations Attachment 5: South Structure Elevations Attachment 6: DRC Action Form 32 ITEM 4 Holiday Inn Solar Canopies PRE 19-0030 / Holland Design Review Committee | City of Atascadero | www.atascadero.org | fb.me/planningatascadero Attachment 1: Aerial View PRE 19-0028 Proposed solar structures Holiday Inn Express 33 ITEM 4 Holiday Inn Solar Canopies PRE 19-0028 / Holland ADDITIONAL INFORMATION MAY BE OBTAINED BY CONTACTING THE ATASCADERO COMMUNITY DEVELOPMENT DEPARTMENT AT http://www.atascadero.org 6500 PALMA AVENUE | ATASCADERO, CA 93422 | (805) 461-5000 Attachment 2: Site Pictures PRE 19-0028 North Property Line South Property Line 34 ITEM 4 Holiday Inn Solar Canopies PRE 19-0028 / Holland ADDITIONAL INFORMATION MAY BE OBTAINED BY CONTACTING THE ATASCADERO COMMUNITY DEVELOPMENT DEPARTMENT AT http://www.atascadero.org 6500 PALMA AVENUE | ATASCADERO, CA 93422 | (805) 461-5000 Attachment 3: Site Plan PRE 19-0028 Proposed Solar Structures 35 ITEM 4 Holiday Inn Solar Canopies PRE 19-0030 / Holland Design Review Committee | City of Atascadero | www.atascadero.org | fb.me/planningatascadero Attachment 4: North Structure Examples PRE 19-0028 36 ITEM 4 Holiday Inn Solar Canopies PRE 19-0030 / Holland Design Review Committee | City of Atascadero | www.atascadero.org | fb.me/planningatascadero Attachment 5: South Structure Examples PRE 19-0028 37 ITEM 4 Holiday Inn Solar Canopies PRE 19-0028 / Holland ADDITIONAL INFORMATION MAY BE OBTAINED BY CONTACTING THE ATASCADERO COMMUNITY DEVELOPMENT DEPARTMENT AT http://www.atascadero.org 6500 PALMA AVENUE | ATASCADERO, CA 93422 | (805) 461-5000 Attachment 6: DRC Action Form PRE 19-0028 CITY OF ATASCADERO Community Development Department 6500 Palma Avenue | Atascadero, CA 93422 | Phone: (805) 461-5035 | www.atascadero.org DRC Action Form Project #: PRE19-0028 Project Title: Drive through Infill Planner/ Project Manager: Mariah Gasch DRC Review Date(s): 4/10/19 Final Action:  DRC  PC  CC Conditions & Recommendations: Yes No Staff recommends that the applicant paint the new structures a darker color to blend in with the surrounding area. 38 ITEM 5 Drive-thru Infill PRE 19-0030 / Lewis ADDITIONAL INFORMATION MAY BE OBTAINED BY CONTACTING THE ATASCADERO COMMUNITY DEVELOPMENT DEPARTMENT AT http://www.atascadero.org 6500 PALMA AVENUE | ATASCADERO, CA 93422 | (805) 461-5000 Atascadero Design Review Committee Staff Report – Community Development Department El Camino Real Drive-Thru Infill MEETING DATE PROJECT PLANNER APPLICANT CONTACT PLN NO. 4/10/19 Mariah Gasch Assistant Planner Peter Lewis (owner) RRM Design Group PRE 19-0030 RECOMMENDATION Staff Recommends to the DRC: Review the conceptual renderings and provide recommendations for any potential design modifications. PROJECT ADDRESS GENERAL PLAN DESIGNATION ZONING DISTRICT ASSESOR PARCEL NUMBER(S) SITE AREA 6925 El Camino Real, Atascadero, CA 93422 Downtown (D) Downtown Commercial 030-513-012 1.64 Acres PROJECT DESCRIPTION The applicant is proposing to infill a first floor space of a healthcare office building that is currently used as a driveway. The infill will create a new 1,600- square foot building shell and increase the patio of existing office space on the second floor directly over it. The façade is designed to match that of the existing building, including stucco walls, matching paint and large multi-paned windows. ENVIRONMENTAL DETERMINATION The City of Atascadero’s environmental review process incorporates the requirements in implementing the California Environmental Quality Act. Persons, agencies, or organizations interested in obtaining more information regarding the environmental should contact the Community Development Department. ☐ EIR / MND / ND / Statutory Exemption to be circulated ☐ Prior CEQA Review CEQA # ____________ Certified: _________ ☒ Cat. Exemption Class ____3_______ CEQA Guidelines § 15303 ☐ No Project - § 15268 Ministerial Project 39 ITEM 5 Drive-thru Infill PRE 19-0030 / Lewis Design Review Committee | City of Atascadero | www.atascadero.org | fb.me/planningatascadero Section of existing building where infill is proposed Zoning Map 40 ITEM 5 Drive-thru Infill PRE 19-0030 / Lewis Design Review Committee | City of Atascadero | www.atascadero.org | fb.me/planningatascadero DISCUSSION: Project Description / Summary The building is located on the intersection of El Camino Real and Highway 41 and hosts the healthcare offices of the First California Physician Partners. The building faces El Camino Real and has a rear parking lot adjacent to the highway. The driveway currently has three access points, two off of Highway 41 and one off of El Camino Real. The driveway from El Camino Real is covered and was once used as a drive-thru ATM service for a former bank tenant. The applicant is proposing a building remodel involving the conversion of the old drive- thru into a new 1600-square foot building shell. The new space would extend approximately ten (10) feet north and south beyond the boundaries of the second floor. As a result, the office spaces above the proposed addition would receive approximately 237 square feet of patio space on the north side of the building and 245 square feet of patio space on the south side of the building. The applicant is also proposing new hardscaping and landscaping on both sides of the addition as well as three new parking spots. DRC DISCUSSION ITEMS: Architecture and Color The applicant is proposing for the new space to match the facade of the existing building. The addition will have two main facades on the North and South of the structure. The plans submitted show both facades as having exterior stucco walls which are scheduled to be painted an off-white shade named “Swiss Coffee.” The south facade which faces El Camino Real is proposed to have two storefront windows which are ten (10) feet tall and approximately six and a half (6.5) feet wide. The northern facade facing the parking lot will have the same design and will include the entrance to the new space. All windows are proposed to be multi-paned with black, metal trim. The new patio space on the second floor will be contained with metal railing on the sides connected to stucco walls on the corners. The railing will match that of the existing building. Staff Recommendations Staff has no recommendations as the applicant is proposing to match the existing façade. Frontage Improvements and Landscaping The proposed addition would completely fill in the existing driveway that passes underneath the second floor. The applicant must install the curb, gutter, and sidewalk at the existing driveway approach as part of their required frontage improvements. These improvements are reflected in their plans and are in compliance with the downtown design standards. The plans submitted show the addition of hardscaped and 41 ITEM 5 Drive-thru Infill PRE 19-0030 / Lewis Design Review Committee | City of Atascadero | www.atascadero.org | fb.me/planningatascadero landscaped areas at front and rear of the structure. The applicant is proposing to plant three new street trees (London Plane Sycamores) along El Camino Real. There is no new lighting proposed as part of the frontage improvements. The site plan also shows an extension of the paved walkway behind the structure which will replace the driveway approach to the existing drive through . The new paved area will help accommodate three new parking spaces. There is no landscaping shown for the extension of this walk way. Staff Recommendations Staff recommends installing acorn street lights along El Camino Real in accordance with Downtown Design Guidelines. The street lights should alternate with the street trees proposed which will require changing the placement of the street trees. The spacing should be similar to the street lights and trees at Colony Square. Staff recommends that the owner include landscaping on the edge of the walkway extension in front of the three new parking spaces. The applicant should provide a landscape plan that is consist with the Water Efficient Landscape Ordinance and shows all new landscaping associated with the remodel. Parking The existing healthcare uses utilize a common parking area that parallels Morro Road. The applicant is proposing the addition of three new parking spaces to the existing parking lot as part of the remodel. The plans submitted state that the new space will remain an empty shell until a tenant is found. Since the future use of the space is unknown, the parking requirements are unknown. Therefore, construction can move forward; however, parking requirements may need to be analyzed prior to any use being established for the new space. In the downtown, most land uses rely on shared parking, and few land uses (except office and residential) require any parking. Fortunately, the office uses in this location have a peak parking demand that is different than the Galaxy Theatre. If land uses in this building exceed the City’s parking requirements, then the applicant may apply for a parking exception that acknowledges shared parking or other off-site parking. Staff Recommendations Staff has no recommendations at this time. Parking requirements will not affect issuance of the building permit. Summary The proposed infill of this space is in alignment with downtown goals. It will eliminate an attractive nuisance (gathering location for homeless), it will provide additional street parking and on-site parking, it will enhance the appearance of the building, and it will eliminate a non-conforming drive through space, while providing additional floor space in the downtown at the City’s gateway. 42 ITEM 5 Drive-thru Infill PRE 19-0030 / Lewis Design Review Committee | City of Atascadero | www.atascadero.org | fb.me/planningatascadero ATTACHMENTS: Attachment 1: Existing Façade Attachment 2: Proposed Façade Rendering Attachment 3: Proposed Elevations Attachment 4: Site Plan Attachment 5: Site Plan with Staff Recommendations Attachment 6: DRC Action Form 43 ITEM 5 Drive-thru Infill PRE 19-0030 / Lewis ADDITIONAL INFORMATION MAY BE OBTAINED BY CONTACTING THE ATASCADERO COMMUNITY DEVELOPMENT DEPARTMENT AT http://www.atascadero.org 6500 PALMA AVENUE | ATASCADERO, CA 93422 | (805) 461-5000 Attachment 1: Existing Facade PRE 19-0030 44 ITEM 5 Drive-thru Infill PRE 19-0030 / Lewis ADDITIONAL INFORMATION MAY BE OBTAINED BY CONTACTING THE ATASCADERO COMMUNITY DEVELOPMENT DEPARTMENT AT http://www.atascadero.org 6500 PALMA AVENUE | ATASCADERO, CA 93422 | (805) 461-5000 Attachment 2: Proposed Façade Rendering PRE 19-0030 45 ITEM 5 Drive-thru Infill PRE 19-0030 / Lewis ADDITIONAL INFORMATION MAY BE OBTAINED BY CONTACTING THE ATASCADERO COMMUNITY DEVELOPMENT DEPARTMENT AT http://www.atascadero.org 6500 PALMA AVENUE | ATASCADERO, CA 93422 | (805) 461-5000 Attachment 3: Proposed Elevations PRE 19-0030 46 ITEM 5 Drive-thru Infill PRE 19-0030 / Lewis Design Review Committee | City of Atascadero | www.atascadero.org | fb.me/planningatascadero Attachment 4: Site Plan PRE 19-0030 47 ITEM 5 Drive-thru Infill PRE 19-0030 / Lewis Design Review Committee | City of Atascadero | www.atascadero.org | fb.me/planningatascadero Attachment 4: Site Plan with Staff Recommendations PRE 19-0030 Install acorn street lights in compliance with downtown standards. Alternate street lights and street trees. Provide landscaping on the edge of the walkway extension in front of the three new parking spaces. 48 ITEM 5 Drive-thru Infill PRE 19-0030 / Lewis Design Review Committee | City of Atascadero | www.atascadero.org | fb.me/planningatascadero Attachment 3: DRC Action Form PRE 19-0030 CITY OF ATASCADERO Community Development Department 6500 Palma Avenue | Atascadero, CA 93422 | Phone: (805) 461-5035 | www.atascadero.org DRC Action Form Project #: PRE19-0030 Project Title: Drive-Thru Infill Planner/ Project Manager: Mariah Gasch DRC Review Date(s): 4/10/19 Final Action:  DRC  PC  CC Conditions & Recommendations: Yes No Install Acorn Street lights along El Camino Real in accordance with downtown area standards. The street lights should alternate with the street trees proposed which will require changing the placement of the street trees. The spacing should be similar to the street lights and trees at Colony Square. Provide landscaping on the edge of the walkway extension in front of the three new parking spaces. The applicant should provide a landscape plan that is consist with the Water Efficient Landscape Ordinance and shows all new landscaping associated with the remodel. 49