HomeMy WebLinkAboutPC_2004-07-20_AgendaPacketCITY OFATASCADERO
PLANNING COMMISSION AGENDA
Regular Meeting
July 20, 2004 — 5:30 P.M.
City of Atascadero
Pavilion on the Lake
9315 Pismo Ave. - Atascadero, California
CALL TO ORDER
Pledge of Allegiance
Roll Call: Chairperson Kelley
Vice Chairperson Jones
Commissioner Fonzi
Commissioner Peterson
Commissioner Beraud
Commissioner O'Keefe
Commissioner Porter
APPROVAL OF AGENDA
PUBLIC COMMENT
(This portion of the meeting is reserved for persons wishing to address the Commission on any matter not
on this agenda and over which the Commission has jurisdiction. Speakers are limited to five minutes.
Please state your name and address for the record before making your presentation. The Commission may
take action to direct the staff to place a matter of business on a future agenda)
CONSENT CALENDAR
(All items on the consent calendar are considered to be routine and non -controversial by City Staff and will
be approved by one motion if no member of the Commission or public wishes to comment or ask questions)
1. APPROVAL OF MINUTES OF THE REGULAR PLANNING COMMISSION
MEETING ON JULY 6, 2004.
PUBLIC HEARINGS
(For each of the following items, the public will be given an opportunity to speak. After a staff report, the Chair will open the public
hearing and invite the applicant or applicant's representative to make any comments. Members of the public will be invited to provide
testimony to the Commission following the applicant. Speakers should state their name and address for the record and can address the
Commission for five minutes. After all public comments have been received, the public hearing will be closed, and the Commission
will discuss the item and take appropriate action(s).)
The Dove Creek Environmental Hearing /teen below begins at 5:30 p.m.
2. PROPOSED MITIGATED NEGATIVE DECLARATION FOR ZONE CHANGE
2003-0049, DOVE CREEK
Applicant:
Bermant Development Company, 5383 Hollister Avenue, Suite 150, Santa Barbara, CA
Project Title:
93111, Phone: 964-7200
Project Title:
Environmental Document for Dove Creek Mixed -Use Development, (Zone Change 2003-
Location:
0049, Conditional Use Permit 2003-0099, Tentative Tract Map 2003-0033) a single-family
Project
residential/commercial center/open space development.
Project
Santa Barbara Road and EI Camino Real, Atascadero, CA 93422 (San Luis Obispo County)
Location-
APN 45-342-03, 45-381-10, 45-381-07, 45-381-09, 45-331-02, 45-331-04, 45-331-08, 45-
331-01, 45-342-05, 45-342-04, 45-342-13, 45-342-01, 45-342-08, 45-342-02, 45-352-05.
Project
Environmental Documentation review for a project consisting of 282 residential dwelling units
Description:
in a variety of styles and densities, approximately 60,000 square feet of neighborhood
Environmental
commercial uses, and 19.2 acres of natural open space.
Determination:
Proposed Zoning: Combination of CR (Commercial Retail), RMF -10 (Residential Multi -
Family), and OS (Open Space).
* This meeting is a review of the prepared environmental documentation for the
project site. Public testimony will be received, however, no action will be taken on this
project at this time.
Regular Planning Commission items below begin at 7;00 p.m.
3. CONDITIONAL USE PERMIT 2004-0129, LARGE FAMILY DAYCARE
Applicant:
Chris Doolin, 9030 San Gabriel Road, Atascadero, CA 93422, Phone 466-0829
Project Title:
Conditional Use Permit 2004-0129; Large Family Day Care
Project
9030 San Gabriel Road, Atascadero, CA 93422
Location:
(San Luis Obispo County) APN 056-211-009
Project
An application to allow a large family day care consisting of seven or more children at an existing
Description:
single-family residence, located at 9030 San Gabriel Road.
General Plan Designation: Single Family Residential
Zoning District: Residential Single Family -Y
Statutory Exemption CEQA
Proposed
Article 18 Section 15274
Environmental
Family Day Care Homes
Determination:
4. AMENDMENT TO CONDITIONAL USE PERMIT 2003-0095, TENTATIVE
TRACT MAP 2004-0052, SAN DIEGO WAY, SOUTHSIDE VILLAS
Applicant:
JRM Enterprises, 1050 Herdsman Way, Templeton, CA 93465 Phone: 238-5313
Project Title:
Southside Villas— Amendment to CUP 2003-0095 for an 84 -unit multi -family residential
Project
development and Tentative Tract Map 2004-0052 for a condominium map.
Project
San Diego Way Lots 9, 11, 12, and 13; Block 66, Atascadero, CA 93422
Location:
(San Luis Obispo County) APN 045-352-002, 003, 004, 006, 007.
Project
The proposed project consists of an amendment to Conditional Use Permit 2003-0095 to
Description-_
revise the previously approved master Plan of Development and to allow for the airspace
subdivision of the units for individual sale and ownership.
General Plan Designation: High Density Multi -Family
Zoning District: Residential Multi -Family - 16
Proposed
Finding of consistency with previously certified Mitigated Negative Declaration 2003-0011.
Environmental
The Mitigated Negative Declaration is available for public review at 6905 EI Camino Real,
Determination
Suite 6, Community Development Department, from 8:00 a.m. to 5:00 p.m., Monday through
Determination
Friday.
5. TENTATIVE PARCEL MAP 2004-0058,2135 SAN FERNANDO RD.
Applicant:
Dan Phillips, 8800 EI Camino Real, Atascadero, CA 93422, Phone 461-1664
Project Title:
Tentative Parcel Map 2004-0058
Project
2135 San Fernando Rd., Atascadero, CA 93422, San Luis Obispo County
Location:
APN 049-281-012
Project
A proposed subdivision of an existing 6.05 gross acre lot into two individual parcels of 2.93 and
Description:
3.12 gross acres. The site is currently under construction for a single-family residence that will be
confined to proposed parcel 1, allowing the new lot to be developed with a single-family
residence. The parcels are steeply sloped and contain vegetation and native oak trees. Onsite
septic will serve the property and water is available from Atascadero Mutual Water Company.
General Plan Designation: Residential Suburban (RS)
Zoning District: Rural Estate RE
Proposed
Based on the initial study prepared for the project, a Mitigated Negative Declaration is proposed.
Environmental
The proposed Negative Declaration is available for public review from 6/7/04 through 7/6/04 at
Determination
6905 EI Camino Real, Suite 6, Community Development Department, from 8:00 a.m. to 5:00 p.m.,
Monday through Friday.
6. TENTATIVE PARCEL MAP 2004-0049, VARIANCE 2004-0003, TECORIDA
AVE.
Applicant: David Graves, 4155 Carrizo Road, Atascadero, CA 93422, Phone 466-5124
Project Title: Tentative Parcel Map 2004-0049 and Variance 2004-0003
Project
Location:
Tecorida Avenue, Atascadero, CA 93422, San Luis Obispo County
APN 030-292-005
Project
A proposed condominium map creating four airspace units and one common lot for a multi -
Description:
family development with a request to modify the interior setbacks between buildings from 10
Location:
feet to 8 feet. The parcel is slightly sloped. Native trees are not proposed for removal. City
Project
sewer will serve the property, and water is available from the Atascadero Mutual Water
Description-
Company.
General Plan Designation: Residential Multi Family
Zoning District: Residential Multi -family — 10 RMF -10
Proposed
The project qualifies for a Class 3(b) Categorical Exemption, which exempts the conversion
Environmental
and/or construction of small structures including multi -family projects of less than 4 units that do
Determination:
not otherwise create a negative impact and Class 5(a) minor setback variances.
COMMUNITY DEVELOPMENT STAFF REPORTS
7. TREE REMOVAL PERMIT 2004-0053
Applicant:
Robert Quigley, 7805 Santa Ynez Avenue, Atascadero, CA 93422, Phone 461-5986
Project Title:
Tree Removal Permit 2004-0053
Project
3858 Orillas Way, Atascadero, CA 93422
Location:
(San Luis Obispo County) APN 049-033-046
Project
Request to remove three (3) Live Oak trees, one of which is over 24 -inches in diameter, in
Description-
conjunction with the development of a 2,380 square -foot single family home with an attached 800
square foot garage located at 3858 Orillas Way
General Plan Designation: Single Family Residential
Zoning District: Residential Single Family -X
COMMISSIONER COMMENTS AND REPORTS
DIRECTOR'S REPORT
ADJOURNMENT
The next regular meeting of the Planning Commission will be on August 3, 2004, at the Pavilion
on the Lake, 9315 Pismo Avenue, Atascadero.
Please note: Should anyone challenge in court any proposed development entitlement listed
on this Agenda, that person may be limited to raising those issues addressed at the public
hearing described in this notice or in written correspondence delivered to the Planning
Commission at, or prior to this public hearing.
City of Atascadero
WELCOME TO THE ATASCADERO PLANNING COMMISSION MEETING
The Planning Commission meets in regular session on the first and third Tuesday of each month at 7:00
p.m., at the Pavilion on the Lake, 9315 Pismo Ave., Atascadero. Matters are considered by the
Commission in the order of the printed Agenda.
Copies of the staff reports or other documentation relating to each item of business referred to on the
Agenda are on file in the office of the Community Development Department and are available for public
inspection during City Hall Annex business hours at the Community Development counter and on our
website, www.atascadero.org. An agenda packet is also available for public review at the Atascadero
Library, 6850 Morro Road. All documents submitted by the public during Commission meetings that are
either read into the record or referred to in their statement will be noted in the minutes and available for
review in the Community Development Department.
In compliance with the Americans with Disabilities Act, if you need special assistance to participate in
a City meeting or other services offered by this City, please contact the City Manager's Office, (805)
461-5000, or the City Clerk's Office, (805) 461-5000. Notification at least 48 hours prior to the meeting or
time when services are needed will assist the City staff in assuring that reasonable arrangements can be
made to provide accessibility to the meeting or service.
TO SPEAK ON AGENDA ITEMS
Members of the audience may speak on any item on the agenda. The Chairperson will identify the
subject, staff will give their report, and the Commission will ask questions of staff. The Chairperson will
announce when the public comment period is open and will request anyone interested to address the
Commission regarding the matter being considered to step up to the podium. If you wish to speak for,
against or comment in any way:
• You must approach the podium and be recognized by the Chairperson
• Give your name and address (not required)
• Make your statement
• All comments should be made to the Chairperson and Commission
• All comments limited to 5 minutes (unless changed by the Commission)
• No one may speak for a second time until everyone wishing to speak has had an opportunity
to do so, and no one may speak more than twice on any item.
If you wish to use a computer presentation to support your comments, you must notify the Community
Development Department at least 24 hours prior to the meeting. Access to hook up your laptop to the
City's projector will be provided. You are required to submit to the Recording Secretary a printed copy
of your presentation for the record. Please check in with the Chairperson before the meeting begins to
announce your presence and turn in the printed copy.
The Chairperson will announce when the public comment period is closed, and thereafter, no further
public comments will be heard by the Council.
TO SPEAK ON SUBJECTS NOT LISTED ON THE AGENDA
Under Agenda item, "PUBLIC HEARINGS", the Chairperson will call for anyone from the audience having
business with the Commission to:
• Please approach the podium and be recognized
• Give your name and address (not required)
• State the nature of your business
This is the time items not on the Agenda may be brought to the Commission's attention. A maximum of
30 minutes will be allowed for Community Forum (unless changed by the Commission).
CITY OF ATASCADERO
PLANNING COMMISSION
DRAFT MINUTES
Regular Meeting
July 6, 2004 — 7:00 P.M.
CALL TO ORDER
Chairperson Kelley called the meeting to order at 7:00 p.m. and Vice Chairperson Jones
led the Pledge of Allegiance.
Rr)l I rAl I
Present: Commissioners Beraud, Fonzi, O'Keefe, Porter, Jones and
Chairperson Kelley
Absent: Commissioner Peterson
Staff Present: Public Works Director Steve Kahn, Deputy Community
Development Director Steve McHarris, Associate Planner Kelley
Gleason, Associate Planner Kerry Margason and Recording
Secretary Grace Pucci.
APPROVAL OF AGENDA
MOTION: By Vice Chairperson Jones and seconded by Commissioner
Fonzi to approve the agenda
Motion passed 6:0 by a roll -call vote.
PUBLIC COMMENT
None
CONSENT CALENDAR
1. APPROVAL OF MINUTES OF THE REGULAR PLANNING COMMISSION
MEETING ON JUNE 15, 2004.
MOTION: By Commissioner Fonzi and seconded by Commissioner
Porter to approve the Planning Commission Minutes of June
15, 2004.
Motion passed 5:0 by a roll -call vote. (Beraud abstain)
PUBLIC HEARINGS
2. CONDITIONAL USE PERMIT 2004-0125,14595 EL MONTE WATER TANK
Applicant:
Atascadero Mutual Water Co. , 5005 EI Camino Real, Atascadero, CA 93422, Phone: 466-2428
Project Title:
CUP 2004-0125, New Water Storage Tank
Project
14595 EI Monte Road, Atascadero, CA 93422
Location:
(San Luis Obispo County) APN 050-361-005
Project
The proposed project consists of a new water storage tank on a vacant lot. The site contains
Description:
several native oak trees and native vegetation. No native trees are to be removed; however,
seven oak trees will be impacted. Onsite grading will require approximately 701 cubic yards of
cut and 644 cubic yards of fill. The lot contains a shared access easement from EI Monte
Road.
General Plan Designation: RS
Zoning District: SE
Environmental
Begins: May 20, 2004
Review Dates:
Ends: June 8, 2004
Proposed
Based on the initial study prepared for the project, a Mitigated Negative Declaration is proposed.
Environmental
The proposed Mitigated Negative Declaration is available for public review at 6905 EI Camino
Determination:
Real, Suite 6, Community Development Department, from 8:00 a.m. to 5:00 p.m., Monday through
Friday.
Commissioner Jones stepped down from consideration of this item as he is Director of
Atascadero Mutual Water Company.
Deputy Community Development Director Steve McHarris provided the staff report and
answered questions of the Commission. An addendum containing a revised Landscape
Exhibit (Exhibit A) as well as a letter from a neighbor expressing her concerns with the
project (Exhibit B) was distributed to the Commission.
PUBLIC COMMENT
John Neil, Atascadero Mutual Water Company, reviewed the issues and concerns
raised at the last Commission meeting in addition to those raised by neighbors and
indicated how the water company would handle those items. Mr. Neil answered
questions of the Commission.
Karen Vaughan explained the requests she had made of the Water Company and why
she had raised those issues. Ms. Vaughan answered questions of the Commission.
Steve Rayburn stated he was supportive of this project, but expressed concern
regarding fire safety issues.
Chairperson Kelley closed the Public Comment period.
Chairperson Kelley suggested adding a condition that the water company would supply
Ms. Vaughan the same water pressure in the future as she has today.
MOTION: By Chairperson Kelley and seconded by Commissioner Fonzi
to adopt Resolution PC 2004-0069 approving Conditional Use
Permit (CUP 2004-0125) based on findings and subject to
Conditions of Approval and adding a condition that Mrs.
Vaughan's water pressure always be maintained at a minimum
of 45 PSI, any cost incurred would be the responsibility of the
Water Company, and adding the staff addendum regarding the
oak trees.
Motion passed 5:0 by a roll -call vote.
Vice Chairperson Jones rejoined the hearing.
3. ZONE CHANGE 2003-0046, CONDITIONAL USE PERMIT 2003-0096,
TENTATIVE TRACT MAP 2003-0031, 2325 EL CAMINO REAL OUTLETS
PHASE 2 AMENDMENT 22 -LOT PD -7
Applicant:
Jeff Borges, 625 Wild Oats Way, Templeton, CA 93465; Phone: 434-3738
Project Title:
Zone Change 2003-0046, Conditional Use Permit 2003-0096, Tentative Tract Map 2003-
0031 for a residential and commercial subdivision with a Planned Development #7 Overlay
Zone.
Project Location:
2325 EI Camino Real, Atascadero, CA 93422, (San Luis Obispo County) APN 049-151-037
Project
The proposed project consists of an application for a Zone Change, Conditional Use Permit,
Description:
and Tentative Tract Map for a planned development 22 -lot subdivision consisting of 16
single-family homes, a small neighborhood park, and 5 commercial lots, each with a 2 -story
commercial building on a 4.0 -acre site.
General Plan Designation: Commercial Retail, Medium -Density Residential
Deputy Community Development Director Steve McHarris provided the staff report and
answered questions of the Commission. A letter from the Rottman Group was
distributed to the Commission (Exhibit C).
PUBLIC COMMENT
Russ Thompson, R. Thompson Consulting, applicant's representative, explained the
meetings held since the last Commission meeting and the subsequent changes that
have been made to the project. He indicated the applicant's preference is to move
forward the original plan and he is ready to go today.
Jim Silver, partner in the project, stated they are anxious to get started with this project
and encouraged the Commission to help them move forward.
Keith Mathias, Rottman Group, representing the property owners to the north and south
of the project, reviewed the meetings he has had with the applicant and his
representative regarding changes to the project.
Maury Froman, President Rottman Froman Communities, owner of the properties
adjoining this project, stated he is here to insure that this project doesn't impact his
ability to improve his property as he would like. Mr. Froman discussed the issues he
would like to see addressed.
Chairperson Kelley closed the Public Comment period.
Several concerns were raised by the Commissioners including: changing the Master
Plan and the potential loss of commercial retail zoning, important that the residential
and commercial are built at the same time, traffic flow, ensure that Phase 2 and Phase
1 line up at the northern and southern entrance to the property, location of the pocket
park in the commercial area of the project reduces the amount of commercial retail and
should be located in the residential area, loss of commercial zoning to office, conceptual
development of commercial retail and loss of reciprocal access.
Chairperson Kelley asked Mr. Mathias if his company could move forward as quickly as
possible with the escrow on an adjoining property in order to proceed with granting the
easement and whether Mr. Thompson felt the applicant would be in favor of a
continuance to allow this to happen. Mr. Mathias stated they could close earlier, but the
Zoning District: General Commercial, Residential Multifamily -10
Environmental
Begins: May 24, 2004
Review
Ends: June 14, 2004
Dates:
Proposed
Based on the initial study prepared for the project, a Mitigated Negative Declaration is
Environmental
proposed. The proposed Mitigated Negative Declaration is available at 6905 EI Camino
Determination:
Real, Suite 6, Community Development Department, from 8:00 a.m. to 5:00 p.m., Monday
through Friday.
Deputy Community Development Director Steve McHarris provided the staff report and
answered questions of the Commission. A letter from the Rottman Group was
distributed to the Commission (Exhibit C).
PUBLIC COMMENT
Russ Thompson, R. Thompson Consulting, applicant's representative, explained the
meetings held since the last Commission meeting and the subsequent changes that
have been made to the project. He indicated the applicant's preference is to move
forward the original plan and he is ready to go today.
Jim Silver, partner in the project, stated they are anxious to get started with this project
and encouraged the Commission to help them move forward.
Keith Mathias, Rottman Group, representing the property owners to the north and south
of the project, reviewed the meetings he has had with the applicant and his
representative regarding changes to the project.
Maury Froman, President Rottman Froman Communities, owner of the properties
adjoining this project, stated he is here to insure that this project doesn't impact his
ability to improve his property as he would like. Mr. Froman discussed the issues he
would like to see addressed.
Chairperson Kelley closed the Public Comment period.
Several concerns were raised by the Commissioners including: changing the Master
Plan and the potential loss of commercial retail zoning, important that the residential
and commercial are built at the same time, traffic flow, ensure that Phase 2 and Phase
1 line up at the northern and southern entrance to the property, location of the pocket
park in the commercial area of the project reduces the amount of commercial retail and
should be located in the residential area, loss of commercial zoning to office, conceptual
development of commercial retail and loss of reciprocal access.
Chairperson Kelley asked Mr. Mathias if his company could move forward as quickly as
possible with the escrow on an adjoining property in order to proceed with granting the
easement and whether Mr. Thompson felt the applicant would be in favor of a
continuance to allow this to happen. Mr. Mathias stated they could close earlier, but the
final decision will be up to the property owner Mr. Messer. Mr. Thompson indicated the
applicant present tonight would be in favor of a continuance.
MOTION: By Commissioner Fonzi and seconded by Commissioner
O'Keefe to continue this item into the near future with a date to
be expedited by staff to be considered.
Motion passed 6:0 by a roll -call vote.
4. CONDITIONAL USE PERMIT 2002-0054, ATASCADERO CHRISTIAN HOME
RECONSIDERATION (CUP 89-008)
Applicant:
Atascadero Christian Home, 8455 Santa Rosa Road, Atascadero, CA 93422, Phone: 466-0281
Project Title:
Reconsideration of Conditional Use Permit 89-008; Senior Assisted Living Facility Expansion
Project
8455 Santa Rosa, Atascadero, CA 93422
Location:
(San Luis Obispo County) APN 056-301-030
Project
An application to expand the existing use at a senior assisted care living facility in Atascadero. The
Description:
proposal includes construction of 19 new individual cottages, a one-story 10 -unit building, grading
and landscaping for associated access and parking areas. The proposed locations would be within
the existing 15.25 -acre development for senior living that has been in existence since 1989. The
project is located on the north side of Santa Rosa Road approximately 1/4 mile west of U.S.
Highway 101. The project will require the removal of several native trees. The proposed building
sites are slightly sloped and occur in a semi -rural primarily grassland setting within a single-family
residential vicinity. The project will gain access from an existing driveway to Santa Rosa Road.
General Plan Designation: Single Family Residential
Zoning District: Residential Single Family -Y
Environmental
Begins: May 14, 2004
Review Dates:
Ends: June 4, 2004
Proposed
Based on the initial study prepared for the project, a Mitigated Negative Declaration is proposed.
Environmental
The proposed Mitigated Negative Declaration is available for public review at 6905 EI Camino
Determination:
Real, Suite 6, Community Development Department, from 8:00 a.m. to 5:00 p.m., Monday through
Friday.
Associate Planner Kerry Margason provided the staff report and answered questions of
the Commission.
PUBLIC COMMENT
Scott Hurley, Atascadero Christian Home, spoke about the project and the need for this
type of facility. Mr. Hurley stated he agreed with the conditions of approval and
answered questions of the Commission.
Chairperson Kelley closed the Public Comment period.
Commissioner O'Keefe asked the applicant if he would have some flexibility in moving
the position of the driveway if it affects the trees. The applicant stated they would be
open to moving the driveway if needed, but would like to go with what is proposed.
MOTION: By Commissioner Porter and seconded by Chairperson Kelley
to adopt Resolution No. PC 2004-0078 certifying the Proposed
Mitigated Negative Declaration and approving the amendment
to Conditional Use Permit 89-008 a request to amend the site
plan subject to the findings, conditions and exhibits as
attached to the resolution.
Motion passed 6:0 by a roll -call vote.
COMMISSIONER COMMENTS AND REPORTS
None
DIRECTOR'S REPORT
Deputy Community Development Director Steve McHarris reviewed the agenda for the
next Planning Commission meeting and the special starting time of 5:30 p.m.
ADJOURNMENT
Chairperson Kelley adjourned the meeting at 8:37 p.m. to the next regularly scheduled
meeting of the Planning Commission on July 20, 2004.
MEETING RECORDED AND MINUTES PREPARED BY:
Grace Pucci, Recording Secretary
The following exhibits are available for review in the Community Development Department:
Exhibit A — Addendum, Revised Landscape Exhibit D
Exhibit B — Karen Vaughan, Letter
Exhibit C — Rottman Group Letter
ITEM NUMBER: 2
DATE: 7120/nd
Planning Commission Staff Report
Staff Report - Community Development Department
63 -Acre Dove Creek Mixed -Use Project
Planned Development Zone Code Text 2004-0080,
Zone Change 2004-0081,
Master Plan of Development (CUP 2004-0128),
Initial Study/Mitigated Negative Declaration 2004-0026
(Bermant Development Company)
SUBJECT:
The purpose of the meeting is to receive a project description and processing
requirements from staff and the applicant, and to receive public comment on the
proposed Dove Creek Mixed -Use Project Draft Initial Study/Draft Mitigated Negative
Declaration, per the requirements of the California Environmental Quality Act (CEQA).
The meeting is being conducted to accept public comments only on the environmental
documentation. No decisions regarding project approval will be made at this time. The
public is encouraged to attend and/or provide written comments through July 16, 2004
to the City of Atascadero Community Development Department, 6905 EI Camino Real,
Suite 6, Atascadero, CA 93422.
The project is described as a master plan development of 282 residential units, 60,000
square feet commercial retail, 19 acres of natural open space on a 63.3 -acre site. The
project site land use is designated mixed-use within the City's general plan.
RECOMMENDATION:
Staff Recommends:
1. Receive report from staff.
2. Open public hearing to receive public comments on the project environmental
documentation.
3. Close public hearing and provide questions/comments to staff.
ITEM NUMBER: 2
DATE: 7120/nd
SITUATION AND FACTS:
1. Applicant / Representative: Bermant Development Co., 5383 Hollister Ave, Suite
150, Santa Barbara, CA 93111-2305
2. Project Address: 63 -acre site between U.S. Highway 101, EI Camino
Real, Santa Barbara Road and San Diego Way
(San Luis Obispo County) APN 45-342-03, 45-381-10, 45-
381-07, 45-381-09, 45-331-02, 45-331-04, 45-331-08, 45-331-01,
45-342-05, 45-342-04, 45-342-13, 45-342-01, 45-342-08, 45-342-
02, 45-352-05.
3. General Plan Designation: Mixed Use (MU)
4. Zoning District: Commercial Retail (CR) with Planned Development
Overlay
5. Site Area: 63.3 acres
6. Existing Use: Vacant
7. Environmental Status: Proposed Mitigated Negative Declaration 2004-0015
DISCUSSION:
On May 11, 2004, the City Council authorized staff to process the application for a
General Plan Amendment and PD -overlay zone change on the subject parcel. Per
Council direction, staff has prepared a draft initial study and draft mitigated negative
declaration to assess potential environmental impacts related to the proposed project.
The draft document and appendix has been provided to the Planning Commission,
interested and jurisdictional public agencies, and has been made available to the public
for review and comment from June 17, 2004 to July 16, 2004. The project description
and environmental analysis is contained within these draft documents.
PREPARED BY: Steve McHarris, Deputy Community Development Director
ATTACHMENTS: Draft Dove Creek Mixed -Use Development Initial
Study/Mitigated Negative Declaration 2004-0026
ITEM NUMBER: 3
DATE: 07-20-04
Atascadero Planning Commission
Staff Report - Community Development Department
Large Family Day Care
CUP 2004-0129
(9030 San Gabriel Road / Doolin)
SUBJECT:
The proposed project is a Conditional Use Permit (CUP 2004-0129) to allow a
large family day care home consisting of seven or more children at an existing
single-family residence.
RECOMMENDATION:
Staff Recommends:
1. Adopt Resolution PC 2004-0077 approving Conditional Use Permit 2004-
0129 based on findings and subjects to Conditions of Approval.
Situation and Facts:
1. Applicant / Representative: Chris Doolin
9030 San Gabriel Road, Atascadero, CA 93422
2. Project Address: 9030 San Gabriel Road, Atascadero, CA 93422
(San Luis Obispo County) APN 056-211-009
3. General Plan Designation: General Plan Designation: Single Family
Residential—Y (SFR -Y)
4. Zoning District: Residential Single Family -Y (RSF-Y)
5. Site Area: Approximately 0.57 acres
ITEM NUMBER: 3
DATE: 07-20-04
6. Existing Use: Small family day care service in Single Family
residence.
7. Environmental Status: Statutory Exemption
CEQA Article 18 Section 15274
Family Day Care Homes
Background:
The existing residence currently operates a small family day care, which is an
allowable use without the requirement of a business license. The project is for a
large family day care, which requires a business license and discretionary approval
through a conditional use permit (AMC 9-6.125). A large family day care home is
defined as a home that provides family day care for 7 to 14 children, including
children under the age of 10 years who reside at the home. Staff has conditioned
that the use permit apply to a maximum of twelve (12) children.
Discussion:
Both state and local requirements are applicable to the establishment of large family
day care homes. According to Atascadero Municipal Code, large family day care
homes are required to provide the following:
• site area consisting of 6,000 square feet or more,
• fenced play areas — 6 feet along property line with residential use, and
• parking and loading to accommodate at least 2 cars in addition to the parking
required for the single-family residence.
The site contains approximately 21,000 square feet with a single-family home and a
detached garage with an attached 400 square foot playroom. An outdoor play area
is located next to the playroom and behind the existing residence and is fenced with
a six-foot high solid wood fence along the property line with an interior five-foot chain
link fence.
An on-site drop off accommodates two (2) or more parked vehicles, in addition to the
existing two -car garage for the use of the residents (Exhibit B). Staff visited the site
with a City vehicle to determine the practicality of egress from the site. The paved
area between the outdoor play area and the residence provides significant space to
accommodate a three-point turn if necessary.
Increasing the amount of six (6) children permitted at a day care home may increase
the level of onsite noise. Although noise levels associated with a day care home are
considered insignificant, the indoor playroom/study area, existing mature vegetation,
and solid wood fencing may buffer the amount of outdoor noise exposure to the
surrounding residential area.
ITEM NUMBER: 3
DATE: 07-20-04
Although no signage is proposed, one identification sign with a maximum area of two
square feet may be erected if material and color are compatible with the surrounding
neighborhood (Exhibit A, Condition 3).
Staff Findings:
1. The proposed project or use is consistent with the General Plan and the City's
Appearance Review Manual.
Staff Comment: The City's appearance review requirements apply to
discretionary projects such as a Conditional Use Permit. The existing residential
property is consistent with appearance review standards for residential
development. Noise impacts are considered reduced by the existing site
improvements that include fencing, surrounding structures, and mature
vegetation (General Plan Goal SFN 10). The noise that may be associated with
the large family day care is considered residential in nature.
2. The proposed land use satisfies all applicable provisions of the Title (Zoning
Ordinance).
Staff Comment: As presented, the project satisfies all conditional use permit
provisions for a large family day care facility.
3. The establishment, and subsequent operation or conduct of the use will not,
because of the circumstances and conditions applied in the particular case, be
detrimental to the health, safety, or welfare of the general public or persons
residing or working in the neighborhood of the use, or be detrimental or injurious
to property or improvements in the vicinity of the use.
Staff Comment: Conditions of approval are included to mitigate any foreseeable
negative impacts that may be detrimental to the general public or working
persons health, safety, or welfare. These conditions include the maintenance of
the site and clear access for unloading and loading children. The project is also
conditioned to adhere to all state and local regulations.
4. That the proposed project or use will not be inconsistent with the character or the
immediate neighborhood or contrary to its orderly development.
Staff Comment: The property is currently used as both a residence and a small
day care home, consistent with the surrounding neighborhood.
ITEM NUMBER: 3
DATE: 07-20-04
Conclusion
The California Health and Safety Code requires large family day care facilities to be
approved if it is in compliance with local ordinances and consistent with traffic
control, parking, and noise control for a residential zone. The proposed project is
consistent with the General Plan and Atascadero Municipal Code, as analyzed
within this staff report. It is staff's recommendation that the proposed project, as
conditioned allows the Planning Commission to make all of the required findings for
project approval.
ALTERNATIVES:
1. The Commission may make modifications to the project and/or conditions of
approval for the project.
2. The Commission may determine that more information is needed on some
aspect of the project and may refer the item back to the applicant and staff to
develop the additional information. The Commission should clearly state the
type of information that is required and move to continue the item to a future
date.
3. The Commission may deny the project. The site would retain its use of a
small family day care home. The Commission should specify the reasons for
denial of the project and make the findings for such action.
PREPARED BY: Lisa Wilkinson, Assistant Planner
ATTACHMENTS:
Attachment 1:
Aerial
Attachment 2
Zoning and Vicinity Map
Attachment 3:
Site Plan
Attachment 4:
Photos
Attachment 5:
Draft Resolution of Approval Proposed Conditional Use Permit
ITEM NUMBER
DATE: 07-20-04
Attachment 2: Zoning and Vicinity Map
ml'I
ill i'
IN
Attachment 3: Site Plan
c 'C :)t s 011C
cr:lri frncr
1 4:
ITEM NUMBER: 3
DATE: 07-20-04
Roo,,
Outside Play Area
2 -Car `
Garage PNI
Loading and Unloading Area
P a•,u,g
sox s_qG»,
Not to Scale.
1�
6 -toot soil /
cedar fence
Shop
I
20x19'
Parking
1
Unroaaq
1
L`J J
ITEM NUMBER: 2
DATE: 07-20-04
Attachment 5: Draft Resolution
RESOLUTION PC 2004-0077
A RESOLUTION OF THE CITY OF ATASCADERO PLANNING
COMMISSION APPROVING CONDITIONAL USE PERMIT 2004-0129
APN 056-211-009
(9030 San Gabriel Road / Doolin)
WHEREAS, an application has been received from Chris Doolin (9030 San Gabriel
Road, Atascadero, CA 93446), Applicant and Property Owner to consider a project
consisting of a conditional use permit for a large family day care home (CUP 2004-0129);
and,
WHEREAS, the laws and regulations relating to the preparation and public notice of
environmental documents, as set forth in the State and local guidelines for implementation of
the California Environmental Quality Act (CEQA) have been adhered to; and,
WHEREAS, the site's General Plan designation is SFR Y (Single Family
Residentia�Y); and,
WHEREAS, the site's zoning designation is RSF-Y (Residential Single Family -Y);
and,
WHEREAS, the Planning Commission of the City of Atascadero held a public
hearing on July 20, 2004; and,
NOW, THEREFORE, the Planning Commission takes the following actions:
SECTION 1. Findings for Approval of Conditional Use Permit. The Planning
Commission finds as follows:
1. The proposed project or use is consistent with the General Plan and the City's
Appearance Review Manual; and,
2. The proposed project or use satisfies all applicable provisions of the Title (Zoning
Ordinance); and,
3. The establishment, and subsequent operation or conduct of the use will not,
because of the circumstances and conditions applied in the particular case, be
detrimental to the health, safety, or welfare of the general public or persons
residing or working in the neighborhood of the use, or be detrimental or injurious
to property or improvements in the vicinity of the use; and,
4. That the proposed project or use will not be inconsistent with the character or the
immediate neighborhood or contrary to its orderly development; and,
ITEM NUMBER: 2
DATE: 07-20-04
5. That the proposed use or project will not generate a volume of traffic beyond the
safe capacity of all roads providing access to the project, either existing or to be
improved in conjunction with the project, or beyond the normal traffic volume of
the surrounding neighborhood that would result from full development in
accordance with the Land Use Element; and,
SECTION 2. Approval. The Planning Commission of the City of Atascadero, in a
regular session assembled on July 20, 2004, resolved to approve Conditional Use Permit
2004-0129 subject to the following:
1. EXHIBIT A: Conditions of Approval
2. EXHIBIT B: Site Plan
BE IT FURTHER RESOLVED that a copy of this Resolution be delivered
forthwith by the Planning Commission Secretary to the City Council of the City of
Atascadero.
AYES:
NOES:
ABSENT:
ABSTAIN:
ADOPTED:
CITY OF ATASCADERO, CA
Bob Kelley
Chairperson
Attest:
Warren M. Frace
Planning Commission Secretary
ITEM NUMBER:
DATE: 07-20-04
EXHIBIT A: Conditions of Approval
Large Family Day Care (CUP 2004-0129)
Conditions of Approval /
Timing
Responsibility
Mitigation
Mitigation Monitoring Program
/Monitoring
Measure
PS: Planning Services
BL: Business License
BS: Building Services
GP: Grading Permit
FD: Fire Department
Large Family Day Care
BP: Building Permit
Fl: Finallnspecfion
PD: Police Department
CE: City Engineer
CUP 2004-0129
TO: Temporary Occupancy
F0: Final Occupancy
WW: Wastewater
CA: City Attomey
Planning Services
1. The large family day care home shall comply with both State
BL
PS
and City of Atascadero regulations.
2. The use permit is for no more than twelve (12) children.
BL
PS
3. A sign no more than two (2) square feet may be erected
BL
PS
subject to appearance review and staff approval.
4. A business license with the City will be maintained/renewed
BL
PS
on an annual basis.
5. All outdoor play areas are to remain enclosed with solid
BL
PS
fencing no less than 4 -feet in height. A six-foot solid fence is
required for play areas abutting residential uses on adjacent
lots.
6. Residential vehicles will not block the designated areas for
BL
PS
drop off or parking locations.
7. At least two adults shall be employed and present during day
PS
care hours of operation.
7. Hours of operation shall be:
BL
PS
Monday thru Friday 7am-6 pm.
EXHIBIT B: Site Plan
CUP 2004-0129
6 -foot solid
cedarrence
21' d
ITEM NUMBER: 2
DATE: 07-20-04
..f 1
Cern
4p^n
., UI51 do PI Jy Arra
1 _.Car
,_OfJC^ � Fool
Loading and Unloading Aroa
PaAdng
N 610ot %olla /
6 -foot \ cedar reflce
chain Ink \
\ Shco
\ 2c x15'
\ 23�:
Park 'a
io— `
1
1
Um uaa':
1
t
1
SOR 9-i »ore
Not to Scale.
ITEM NUMBER
DATE: 07-20-04
ITEM NUMBER: 4
DATE: 7/20/04
Planning Commission Staff Report
Staff Report - Community Development Department
Southside Villas
Reconsideration of CUP 2003-0095
Condo Map TTM 2004-0052
(9190 San Diego Way/JRM Enterprises)
SUBJECT:
The proposed project consists of a revision to a previously approved Master Plan of
Development (Conditional Use Permit) and Condominium Map application for an 84 -unit
multi -family development.
RECOMMENDATION:
Staff Recommends:
1. Adopt Resolution PC 2004-0081 recertifying Mitigated Negative Declaration 2003-
0011; and,
2. Adopt Resolution PC 2004-0082 to approve revisions to Master Plan of
Development (CUP 2003-0095) based on findings and subject to Conditions of
Approval and Mitigation Monitoring; and,
3. Adopt Resolution PC 2004-0083 to approve Vesting Tentative Parcel Map 2004-
0052 based on findings and subject to Conditions of Approval and Mitigation
Monitoring.
ITEM NUMBER: 4
DATE: 7/20/04
SITUATION AND FACTS:
1. Applicant/ Representative: JRM Development
80913 th Street, Paso Robles, CA 93446
2. Project Address: 9190 San Diego Way, Atascadero, CA 93422
(San Luis Obispo County) APN 045-352-002, 003, 004,
006,007
3. General Plan Designation: General Plan Designation: High -Density Residential
(16 units/acre)
4. Zoning District: RMF -16 (Residential Multiple Family)
5. Site Area: 4.06 acres gross, 3.97 acres net
6. Existing Use: Single Family Residences, approved 86 -unit
development entitlement
7. Environmental Status: Consistent with the previously certified Mitigated
Negative Declaration 2003-0011 prepared for CUP
2003-0095.
DISCUSSION:
Background
On October 21, 2003, the Planning Commission approved a Master Plan of
Development to allow the construction of an 86 -unit apartment development at the
project location. The applicant is requesting an amendment to the project to allow minor
site and building configuration changes resulting in an 84 -unit multi -family development.
Included with the amendment application is a condominium map proposal which would
allow individual sale and ownership of each unit. The 35% density bonus for the
provision of love and/or very bw-income units that was previously approved for the
project is included in this request.
Project Definition
The applicant is proposing amendments to the approved Master Plan of Development to
include: increases in building size; elimination of common laundry facilities and inclusion
of individual facilities in each unit; architectural design changes; and minor
reconfigurations of open space areas.
ITEM NUMBER: 4
DATE: 7/20/04
The project, as proposed, includes 84 condominium units, 60 of which are two-bedroom
units with the remaining 24 proposed as three-bedroom units. The project includes 197
parking spaces for residents and guests in accordance with code requirements.
Project Summary Table
Lot Area
3.997ac net
Building coverage
47,064 sqft
(not to exceed 50%)
27%
Outdoor recreation area
28,556 sqft
Parking Spaces
188 total
Covered
84
Guest
17
Surroundina Land Use and Settin
The project site is within the High Density Multi -family General Plan land use
designation and is zoned Residential Multi -family -16. Properties to the west are zoned
Residential Multi -family allowing for a potential of up to 16 dwelling units per acre. The
63 -acre Dove Creek project area is located to the south of the project site and is
currently proposing a variety of residential uses and open space areas adjacent to the
project site.
I VV. Proposed
�ulti-Family Apartments
Public
Dove CreekMixed-Use
Area
North: High Density Residential
South: Commercial Retail — Mixed -Use Planned
Development designation
East: High Density Residential/Commercial
Tourist
West: High Density Residential
ITEM NUMBER: 4
DATE: 7/20/04
Appearance Review
Architecture. Materials. Color
The architecture has been modified from a craftsman style to a Spanish -themed
building design. The applicant has upgraded building materials to include Spanish tile
roofing, smooth finished stucco exterior, decorative ironwork, and upgraded recessed
windows (See Attachment 4 for review of previously approved elevations). As proposed,
the residential units will retain private outdoor patio spaces oriented toward landscaped
open space areas. Front entrances have been relocated to within a common
entranceway and "balconettes" (small ornamental balcony features) have been
incorporated on all sides of the proposed residential buildings. The rear entry patios
have been upgraded to include additional entrance features such as decorative iron
railing with smooth finish pilasters consistent with the building architectural theme.
Elevations
ITEM NUMBER: 4
DATE: 7/20/04
iyy
rK iir�
--�sraEv►tioV o
iia ww
wr rr
II/A
Mr rr
tiw
!.I � i.11•
The applicant has included a color and material board illustrating color and material
schemes. Refer to Exhibit H for details.
Landscape Design
The proposed landscape plan is consistent with the approved Master Plan of
Development with the exception of a reconfiguration of the open space courtyards. The
central open space areas have been redesigned to include formal pathways and
prominent rear patio entrances to the ground floor units. Wood trellis features have also
been integrated into the entranceways to these areas to create a refined residential
amenity.
The project, as proposed, retains an informal landscape buffer along EI Camino Real
and street trees planted along San Diego Way with additional shade trees within the
project site. Parking lot landscaping features landscape fingers throughout. The tot lot
located along the south-east corner of the project site has been redesigned to
accommodate the required parking and building configuration. The rehabilitated
wetlands area is retained on-site with limited access as recommended by the project
biologist.
ITEM NUMBER: 4
DATE: 7/20/04
Site Plan, Circulation, Parking
The project includes a total of 197 parking spaces, consistent with the previously
approved project and consistent with code requirements, as noted in the chart below.
The project retains two access points off of San Diego Way with a third emergency
access onto EI Camino Real as previously approved (See Attachment 3 for previously
approved site plan).
Pedestrian pathways are included throughout the project site including a revised main
pedestrian entrance off of San Diego Way. Pedestrian connectivity to the adjacent Dove
Creek development has been relocated to the eastern edge of the project site,
consistent with conceptual plan for the adjacent development. A condition has been
included that allows flexibility in the location of the pedestrian connection to align with
the final Dove Creek Development (Condition CUP 12).
Site Drainage
The site is moderately sloped to the south-west. Consistent with the previously
approved development plan, shallow stormwater detention basins have been
incorporated into the design of the common open space areas located between
residential buildings. Detention basins have been designed in accordance with City
standards. The use of these areas as a resident amenity will not be limited by the
temporary water capacity of the proposed basins and a Condition is included to ensure
that these areas remain open and accessible to residents and guests and shall not be
fenced (Condition CUP 8). On-site drainage is also designed to create and enhance the
on-site wetland restoration area located along the southerly boundary of the site as
discussed below.
Wetland Rehabilitation
The project site contains a degraded wetland in areas along the south and east
boundaries extending partially onto the project site. The approved Master Plan of
Development will disturb portions of the existing wetland area. As such, staff retained
# of units
Required spaces
Parking
Spaces
Provided
Two Bedroom Units
60
2
120
Three Bedroom Units
24
2.5
60
Guest Parking
84
1/5 units
16.8
Total Parking
spaces required
196.8
Pedestrian pathways are included throughout the project site including a revised main
pedestrian entrance off of San Diego Way. Pedestrian connectivity to the adjacent Dove
Creek development has been relocated to the eastern edge of the project site,
consistent with conceptual plan for the adjacent development. A condition has been
included that allows flexibility in the location of the pedestrian connection to align with
the final Dove Creek Development (Condition CUP 12).
Site Drainage
The site is moderately sloped to the south-west. Consistent with the previously
approved development plan, shallow stormwater detention basins have been
incorporated into the design of the common open space areas located between
residential buildings. Detention basins have been designed in accordance with City
standards. The use of these areas as a resident amenity will not be limited by the
temporary water capacity of the proposed basins and a Condition is included to ensure
that these areas remain open and accessible to residents and guests and shall not be
fenced (Condition CUP 8). On-site drainage is also designed to create and enhance the
on-site wetland restoration area located along the southerly boundary of the site as
discussed below.
Wetland Rehabilitation
The project site contains a degraded wetland in areas along the south and east
boundaries extending partially onto the project site. The approved Master Plan of
Development will disturb portions of the existing wetland area. As such, staff retained
ITEM NUMBER: 4
DATE: 7/20/04
the previously approved conditions of approval pertaining to building location and
wetland reconstruction methods.
The project biologist reviewed the requested site changes and has added no additional
conditions to the project. However, per the request of the biologist, a retaining wall
design has been incorporated into the rehabilitated wetland area in order to ensure a
safe habitat for existing wildlife.
Wastewater
The project will connect to City sewer.
Density Bonus Provisions
A 35% density bonus (up to 22 units) for the provision of affordable income units was
approved by the Planning Commission during the initial project approval. The applicant
is maintaining this request and, consistent with the previous approval, will be required to
deed restrict either 10% of the pre -density bonus project units as very low-income units
(6.4 units), or 20% of the pre -density bonus units as low-income units (12.8 units), in
accordance with State Law. A condition has been added to ensure that this state
requirement is met and maintained over the required 30 -year period (Condition CUP 6,
TTM 7).
General Plan Consistency
The proposed project is consistent with the following General Plan Land Use Element
Policies:
Land Use Policy 1.1: "Preserve the rural atmosphere of the community and assure
"elbow room" in areas designed for lower density development by guiding new
development into the Urban Core to conform to the historic Colony land use patterns of
the City and to respect the natural environment, hillside area and existing
neighborhoods".
Housing Element Policy 1.2: "Encourage a variety of high quality developments with
detached units on individual lots or airspace condominiums on commonly owned lots. "
Housing Element Policy 2.2: "Promote and encourage availability of new housing units
to first time homebuyers. "
Housing Element Policy 4.3: "Encourage attractive architecture and site landscaping
that respect terrain and native trees".
ITEM NUMBER: 4
DATE: 7/20/04
Implementing General Plan programs require appearance review of architectural
design, materials, street trees, and landscaping to maintain the retain the rural
atmosphere, protect the environment, and incorporate architectural themes into the site
and building design. As analyzed above, the proposed project as conditioned is
consistent with the General Plan.
In staff's opinion the project is consistent with the goals and policies of the Land Use
Element and the Housing Element. The project will provide 84 condominium units that
fulfill an important housing need within the community and follow the General Plan's
policies relating to the implementation of smart growth principles. As conditioned, the
project incorporates architectural and landscape elements that are consistent Wth the
scale and character of the surrounding neighborhood and the General Plan's
appearance review requirement. The proposed project provides a high quality infill
development within the City's urban core area. The proposed residential use is
consistent with the surrounding neighborhood use and character.
Tentative Tract Map
An 85 -lot condominium map is proposed consistent with the Master Plan of
Development, establishing 84 airspace units on one common lot. The project has been
conditioned to meet all requirements of the Atascadero Municipal Code.
Master Plan of Development (Conditional Use Permit)
The Planning Commission must make the following five findings to approve the revised
Master Plan of Development (CUP 2003-0095):
1. The proposed project or use is consistent with the General Plan and the City's
Appearance Review Manual.
Staff Comment: The use is consistent with the Multi -Family Residential designation
of the Plan and General Plan Land Use Element Policy 1.1, Housing Element Policy
1.2, Housing Element Policy 2.2, and Housing Element Policy 4.3.
2. The proposed project or use satisfies all applicable provisions of the Title (Zoning
Ordinance).
Staff Comment: As conditioned and based on findings, the project satisfies all
zoning code provisions.
3. The establishment, and subsequent operation or conduct of the use will not,
because of the circumstances and conditions applied in the particular case, be
detrimental to the health, safety, or welfare of the general public or persons residing
ITEM NUMBER: 4
DATE: 7/20/04
or working in the neighborhood of the use, or be detrimental or injurious to property
or improvements in the vicinity of the use.
Staff Comment: The proposed residential project will not be detrimental to the
general public or working persons health, safety, or welfare.
4. The proposed project or use will not be inconsistent with the character or the
immediate neighborhood or contrary to its orderly development.
Staff Comment: The project has been designed to be consistent with the existing
neighborhood character.
5. The proposed use or project will not generate a volume of traffic beyond the safe
capacity of all roads providing access to the project, either existing or to be improved
in conjunction with the project, or beyond the normal traffic volume of the
surrounding neighborhood that would result from full development in accordance
with the Land Use Element.
Staff Comment: The proposed project and use is consistent with the traffic
projections and road improvements anticipated within the General Plan.
Based on staff's analysis in the preceding sections, and with the incorporation of the
project conditions, it appears that all of the required findings for approval of a Master
Plan of Development (Conditional Use Permit) can be made.
Proposed Environmental Determination
The Planning Commission certified Mitigated Negative Declaration 2003-0011 on
October 21, 2003. The proposed revisions are consistent with the previously certified
document. Draft resolution PC 2003-0081 has been included to allow the Planning
Commission to re -certify the original environmental documentation.
Conclusion
The proposed project is consistent with the approved Master Plan of Development,
General Plan, and Atascadero Municipal Code, as analyzed within this staff report. The
requested revisions to the site plan and architectural theme, in addition to the requested
condominium map is consistent with land use and housing element goals. The applicant
has upgraded architectural elements throughout the project and has revised the site
plan to include emphasized pedestrian pathways and circulation corridors. The
applicant agrees with all mitigation measures and conditions of approval. It is staff's
opinion that the proposed project, as conditioned, allows the Planning Commission to
make all of the required findings for project approval.
ITEM NUMBER: 4
DATE: 7/20/04
ALTERNATIVES
1. The Commission may make modifications to the project revisions and/or
conditions of approval for the project.
2. The Commission may determine that more information is needed on some
aspect of the project and may refer the item back to the applicant and staff to
develop the additional information. The Commission should clearly state the type
of information that is required and move to continue the item to a future date.
3. The Commission may deny the project revision. The previously approved Master
Plan of Development would remain valid. The Commission should specify the
reasons for denial of the project and make an associated finding with such
action.
PREPARED BY: Kelly Gleason, Associate Planner
ATTACHMENTS:
Attachment 1:
Location Map, Zoning and General Plan
Attachment 2:
Certified Mitigated Negative Declaration 2003-0011 and Initial Study
Attachment 3:
Previously approved Site Plan
Attachment 4:
Previously approved Elevations
Attachment 5:
Draft Resolution PC 2004-0081
Attachment 6:
Draft Resolution PC 2004-0082
Attachment 7:
Draft Resolution PC 2004-0083
ITEM NUMBER: 4
DATE: 7/20/04
Attachment 1: Location Map, General Plan and Zoning
1
Multi -Family
Proposed
Project
_r
`\ \ Public
Dove Creek 1
Area
General Plan Desi nation:
- High Density Residential
Zoning District:
- Residential Multi -Family - 16
ITEM NUMBER
DATE: 7/20/04
Attachment 2: Certified Mitigated Negative Declaration 2003-0011 and Initial Study
This page intentionally left blank
Attachment 3: Previously approved Site Plan
ITEM NUMBER: 4
DATE: 7/20/04
)\K- !^ - -
ir
)\K- !^ - -
lmwll jmm
'I Iml; !!IV 1:11
M.
ITEM NUMBER: 4
DATE: 7/20/04
Attachment 5: Draft Resolution PC 2004-0081
Re -certification of Mitigated Negative Declaration 2003-0011
DRAFT RESOLUTION PC 2004-0081
A RESOLUTION OF THE PLANNING COMMISSION
OF THE CITY OF ATASCADERO RE -CERTIFYING MITIGATED
NEGATIVE DECLARATION 2003-0011 PREPARED FOR AN
AMENDMENT TO CONDITIONAL USE PERMIT 2003-0095 AND
PROPOSED TENTATIVE TRACT MAP 2004-0052
APN 045-352-0029 0039 0049 0069 007
(9190 San Diego Way/JRM Enterprises)
WHEREAS, an application has been received from JRM Development (809 13th Street,
Paso Robles, CA 93446), Applicant and Property Owner to consider an amendment to the
Master Plan of Development (CUP 2003-0095) and to consider an application for a
condominium map (TTM 2004-0052) to approve an 84 -unit multifamily development; and,
WHEREAS, an Initial Study and Proposed Mitigated Negative Declaration 2003-0011
were prepared for the project and made available for public review in accordance with the
requirements of the California Environmental Quality Act (CEQA); and,
WHEREAS, the Planning Commission of the City of Atascadero held a public hearing
on July 20, 2004 following the close of the review period to consider the Initial Study and
Proposed Mitigated Negative Declaration; and,
NOW, THEREFORE, the Planning Commission of the City of Atascadero, hereby
resolves to re -certify Mitigated Negative Declaration 2003-0011 based on the following Findings
as shown on Exhibit A:
1. The Mitigated Negative Declaration has been completed in compliance with
CEQA; and,
2. The Mitigated Negative Declaration was presented to the Planning Commission,
and the information contained therein was considered by the Planning
Commission, prior to recommending action on the project for which it was
prepared; and,
3. The project does not have the potential to degrade the environment when
mitigation measures are incorporated into the project.
ITEM NUMBER: 4
DATE: 7/2n/n4
4. The project will not achieve short-term to the disadvantage of long-term
environmental goals.
5. The project does not have impacts, which are individually limited, but
cumulatively considerable.
6. The project will not cause substantial adverse effects on human beings either
directly or indirectly.
BE IT FURTHER RESOLVED that a copy of this Resolution be delivered forthwith by
the Planning Commission Secretary to the City Council of the City of Atascadero.
On motion by Commissioner , and seconded by Commissioner
the foregoing resolution is hereby adopted in its entirety by the following roll call vote:
AYES:
NOES:
ABSENT:
ABSTAIN:
ADOPTED:
CITY OF ATASCADERO, CA
Bob Kelley
Planning Commission Chairperson
Attest:
Warren M. Frace
Planning Commission Secretary
ITEM NUMBER:
DATE: 7/20/04
Exhibit A: Mitigated Negative Declaration 2003-0011
This page intentionally left blank
Attachment 6: Draft Resolution PC 2004-0082
Approval of Amended Master Plan of Development
DRAFT RESOLUTION PC 2004-0082
A RESOLUTION OF THE PLANNING COMMISSION
OF THE CITY OF ATASCADERO APPROVING AN AMENDMENT
TO MASTER PLAN OF DEVELOPMENT (CUP 2003-0095)
ON APN 045-352-0029 0039 0049 0069 007
(9190 San Diego Way/JRM Enterprises)
WHEREAS, an application has been received from JRM Development (809 13th Street,
Paso Robles, CA 93446), Applicant and Property Owner to consider an amendment to the
Master Plan of Development (CUP 2003-0095) and to consider an application for a
condominium map (TTM 2004-0052) to approve an 84 -unit multifamily development; and,
WHEREAS, the site's General Plan Designation is HDR (High -Density Residential);
and,
WHEREAS, the site's current zoning district is RMF -16 (Residential Multiple -Family);
and,
WHEREAS, the laws and regulations relating to the preparation and public notice of
environmental documents, as set forth in the State and local guidelines for implementation of the
California Environmental Quality Act (CEQA) have been adhered to; and,
WHEREAS, a timely and properly noticed Public Hearing upon the subject Conditional
Use Permit Amendment application was held by the Planning Commission of the City of
Atascadero at which hearing evidence, oral and documentary, was admitted on behalf of said
Amended Master Plan of Development; and,
WHEREAS, the Planning Commission of the City of Atascadero, at a duly noticed
Public Hearing held on July 20, 2004, studied and considered the Amended Master Plan of
Development (CUP 2003-0095), after first studying and considering the Mitigated Negative
Declaration prepared for the project, and
NOW, THEREFORE, the Planning Commission takes the following actions:
SECTION 1. Findings for approval of Master Plan of Development. The Planning
Commission finds as follows:
The proposed project or use is consistent with the General Plan and the City's
Appearance Review Manual; and,
2. The proposed project or use satisfies all applicable provisions of the Title (Zoning
Ordinance); and,
3. The establishment, and subsequent operation or conduct of the use will not, because
of the circumstances and conditions applied in the particular case, be detrimental to
the health, safety, or welfare of the general public or persons residing or working in
the neighborhood of the use, or be detrimental or injurious to property or
improvements in the vicinity of the use; and,
4. That the proposed project or use will not be inconsistent with the character or the
immediate neighborhood or contrary to its orderly development; and,
That the proposed use or project will not generate a volume of traffic beyond the safe
capacity of all roads providing access to the project, either existing or to be improved
in conjunction with the project, or beyond the normal traffic volume of the
surrounding neighborhood that would result from full development in accordance
with the Land Use Element.
SECTION 2. Approval. The Planning Commission of the City of Atascadero, in a regular
session assembled on July 20, 2004, resolved to approve amendments to the Master Plan of
Development (CUP 2003-0095) subject to the following:
EXHIBIT A:
Conditions of Approval
EXHIBIT B:
Site Plan
EXHIBIT C:
Grading and Drainage Plan
EXHIBIT D:
Landscape Plan
EXHIBIT E:
Elevations
EXHIBIT F:
Lower Floor Plans
EXHIBIT G:
Upper Floor Plans
EXHIBIT H:
Accessory Structure Designs
EXHIBIT I:
Materials Board
EXHIBIT J:
Preliminary Biological Assessment; Althouse and Mead
EXHIBIT K:
Follow-up Biological Assessment, Althouse and Mead
EXHIBIT L:
Project Statistical Summary
EXHIBIT M:
Off-site public improvements
On motion by Commissioner , and seconded by Commissioner
the foregoing resolution is hereby adopted in its entirety by the following roll call vote:
AYES:
NOES:
ABSENT:
ABSTAIN:
ADOPTED:
CITY OF ATASCADERO, CA
Bob Kelley
Planning Commission Chairperson
Attest:
Warren M. Frace
Planning Commission Secretary
Exhibit A: Conditions of Approval
Conditions of Approval /
Timing
Responsibility
Mitigation
Mitigation Monitoring Program
/Monitoring
Measure
PS: Planning Services
BL: Business
BS: Building Services
9190 San Diego Way
License
FD: Fire Department
Southside Villas
GP: Grading Permit
BP: Building Permit
PD: Police Department
CE: City Engineer
CUP 2003-0095 (Amendment)
FI: Final Inspection
TO: Temporary
WW: Wastewater
CA: City Attorney
Occupancy
F0: Final
Occupancy
Planning Services
1. This conditional use permit shall be for a 84-u nit multi -family
Ongoing
PS
development, parking lot, and landscaping on a 4.06 -acre siteas
described on the attached exhibits and located on parcel 045-352-
002, 003, 004, 006, 007regardless of owner.
2. The approval of this use permit shall become final and effective for the
FM
PS
purposes of issuing building permits fourteen (14) days following the
Planning Commission approval unless prior to the time, an appeal to
the decision is filed as set forth in Section 9-1.111(b) of the Zoning
Ordinance.
3. The Community Development Department shall have the authority to
BP / FM
PS
approve the following minor changes to the project that (1) modify the
site plan project by less than 10%, (2) result in a superior site design
or appearance, and/or (3) address a construction design issue that is
not substantive to the Master Plan of Development. The Planning
Commission shall have the final authority to approve any other
changes to the Conditional Use Permit.
4. Approval of this Conditional Use Permit shall be valid for twelve (12)
BP / FM
PS
months after its effective date. At the end of the period, the approval
shall expire and become null and void unless the project has received
a building permit.
5. All exterior elevations, finish materials and colors shall be consistent
BP
PS
with the Master Plan of Development as shown in EXHIBIT E, H, and
I.
6. All site development shall be consistent with the maximum intensities
BP/FM
PS
described in the statistical project summary as shown on EXHIBIT L.
7. All site work, grading and site improvements shall be consistent with
BP/FM
PS
the Master Plan of Development as shown in EXHIBIT B, C, and D.
8. A final landscape and irrigation plan shall be approved prior to the
BP
PS
issuance of building permits and included as part of site improvement
plan consistent with EXHIBIT D. All exterior meters, air conditioning
units, and mechanical equipment shall be screened with landscape
material. Trash/recycle container areas shall be screened w ith
fencing or landscape.
Conditions of Approval /
Timing
Responsibility
Mitigation
Mitigation Monitoring Program
/Monitoring
Measure
PS: Planning Services
BL: Business
BS: Building Services
9190 San Diego Way
License
FD: Fire Department
Southside Villas
GP: Grading Permit
BP: Building Permit
PD: Police Department
CE: City Engineer
CUP 2003-0095 (Amendment)
FI: Final Inspection
TO: Temporary
WW: Wastewater
CA: City Attorney
Occupancy
F0: Final
Occupancy
9. All project fencing shall be consistent with EXHIBIT Hand shall be
BP
PS
installed along the site perimeter subject to the following.
a. Fence pillars and/or wall features shall incorporate materials
consistent with the architectural theme, subject to staff approval.
b. All fencing shall be low and transparent in nature and shall not
exceed a height of 5 feet with columns at a maximum of 6 feet high.
c. Fencing shall be set back a minimum of 5 feet from the property
line at EI Camino Real. No fencing shall be located along San
Diego Way.
10. Retaining walls shall incorporate design & materials to utilize dark
GP
PS
color split face block or material compatible with the architectural
BP
theme, subject to staff approval. Retaining wall adjacent to wetland
area and along project edge shall be of dark color split face block to
blend with the natural vegetation, subject to staff approval.
11. Affordable Housing Requirement: The applicant shall set aside 10%
FM, BP
PS, CE
of the base density units at the very low-income rate, or 20% of the
base density units at the low-income rate for a period of 30 years. At
least one three-bedroom unit shall be deed restricted.
12. All exterior material finishes (stucco, materials, lighting) shall be
BP
PS
durable, high quality, and consistent with the elevations shown in
EXHIBIT E, H, and I. with the incorporation of the following, subject to
staff approval:
A A minimum of two color schemes utilizing the same pallet shall be
utilized throughout the project.
B. All windows shall be of vinyl material and shall be gridded as shown
in EXHIBIT E. Windows shall be recessed from the exterior building
fagade.
C. Windows on side elevations listed as "optional' shall be included on
all side elevations facing open space and parking areas.
D. Tile accents shall be incorporated into the stucco pilasters at the
rear entrance patios.
13. Unobstructed access shall be provided between the rear patios and
FM
PS, CE
the shared common open space areas, as shown in EXHIBIT E.
Open Space areas acting as detention basins shall remain open and
un -fenced.
14. All trash enclosures shall be finished with non -machine finished, hand
BP
PS
troweled or similar stucco consistent with the proposed architecture
and consistent with EXHIBIT E.
Conditions of Approval /
Timing
Responsibility
Mitigation
Mitigation Monitoring Program
/Monitoring
Measure
PS: Planning Services
BL: Business
BS: Building Services
9190 San Diego Way
License
FD: Fire Department
Southside Villas
GP: Grading Permit
BP: Building Permit
PD: Police Department
CE: City Engineer
CUP 2003-0095 (Amendment)
FI: Final Inspection
TO: Temporary
WW: Wastewater
CA: City Attorney
Occupancy
F0: Final
Occupancy
and consistent with EXHIBIT E.
15. Landscaping along the southern portion of the site, adjacent to the off-
BP
PS
site wetland and on-site wetland restoration area shall include native
tree and shrub plantings
16. Monument entry signage shall be consistent with design shown in
BP
PS
EXHIBIT H, and shall i nclude the following subject to staff approval:
■ Signage lettering shall be constructed of individual die cut raised
metal letters mounted on a smooth stucco face consistent with
building color and finish.
17. The pedestrian connection to the adjacent Dove Creek open space
BP
PS
area shall be located to adjoin pathways proposed for the adjacent
project.
18. The fire access portion of the driveway shall incorporate decorative
BP
PS
pavers and decorative removable bollards.
19. A pedestrian access path shall be provided from EI Camino Real onto
BP
PS
the project site and shall connect with the internal pedestrian
pathways throughout the project.
20. Rear ground floor patio areas facing EI Camino Real shall be
BP
PS
extended where possible to maximize private open space for each
unit.
21. Parking shade structures shall be constructed of heavy timber, or
BP
PS
similar metal elements, and shall be designed with a flat trellis style
roof, consistent to open space entry feature trellises and subject staff
approval.
22. Workforce Housing
FM
PS, CE
Prior to issuance of building permits, the applicant shall enter into a legal
agreement with the City to reserve '/2 of the units to residents or workers
within the City of Atascadero, including the affordable units. The agreement
shall include the following provisions:
■ The units shall be offered for rent to residents or workers within the
City of Atascadero for a minimum of 60 -days. During this time period
offers may only be accepted from Atascadero residents or workers;
■ The applicant shall provide reasonable proof to the City that at least
one of the qualified renters is a resident or worker within the City Limits
of Atascadero;
■ The Atascadero resident or worker restriction shall apply to the initial
Conditions of Approval /
Timing
Responsibility
Mitigation
Mitigation Monitoring Program
/Monitoring
Measure
PS: Planning Services
BL: Business
BS: Building Services
9190 San Diego Way
License
FD: Fire Department
Southside Villas
GP: Grading Permit
BP: Building Permit
PD: Police Department
CE: City Engineer
CUP 2003-0095 (Amendment)
FI: Final Inspection
TO: Temporary
WW: Wastewater
CA: City Attorney
Occupancy
F0: Final
Occupancy
rental only;
■ The applicant shall identify which units will be reserved; and
■ The City Attorney shall approve the final form of the agreement.
23. As previously approved, removal of the 48" oak tree shall be mitigated
by the payment of $1600.00 into the tree replacement fund as
required by the tree ordinance.
Building Services
24. A soils investigation prepared by a licensed Geotechnical Engineer
BP
FM
is to be provided for the project. The report is to be provided at the
time of building permit submittal along with the building plans for
review by the Building Division. Recommendations contained in
the report are to be incorporated into the project plans.
Fire Marshal
25. Provide a letter from the Atascadero Mutual Water Company
stating the minimum expected water available to the site. Amount
available must meet min. requirement specified in the California
Fire Code.
26. Show location of existing and any proposed fire hydrants.
BP
FD
27. Note approved address signage is to be provided.
BP
FD
28. Note on plans that fire lanes shall be delineated to restrict parking
BP
FD
as required by the Fire Authority.
29. One additional fire hydrant shall be added to the emergency
BP
FD
access area off of EI Camino Real, subject to the approval of the
fire marshal.
City Engineer
Standard Conditions
30. The applicant shall enter into a Plan Check & Inspection agreement
BP
BS
with the City.
31. The applicant shall be responsible for the protection, relocation
BP
BS
and/or alteration of existing utilities.
32. The applicant shall install all new utilities (water, gas, electric, cable
BP
BS
TV and telephone) underground.
33. The applicant shall monument all property corners for construction
BP
BS
control and shall promptly replace them if disturbed.
34. Prior to issuance of building permits, the applicant shall submit a
BP
BS
grading and drainage plan with a separate sheet(s) devoted to
sedimentation and erosion control, prepared by a registered civil
Conditions of Approval /
Timing
Responsibility
Mitigation
Mitigation Monitoring Program
/Monitoring
Measure
PS: Planning Services
BL: Business
BS: Building Services
9190 San Diego Way
License
FD: Fire Department
Southside Villas
GP: Grading Permit
BP: Building Permit
PD: Police Department
CE: City Engineer
CUP 2003-0095 (Amendment)
FI: Final Inspection
TO: Temporary
WW: Wastewater
CA: City Attorney
Occupancy
F0: Final
Occupancy
engineer for review and approval by the City Engineer.
35. Prior to the final inspection, all outstanding plan check and
BP
BS
inspection fees shall be paid.
36. All construction activities shall comply with the City of Atascadero
BP
BS
Noise Ordinance for hours of operation.
Construction activities shall be limited to the following hours of
operation:
• 7 a.m. to 7 p.m. Monday through Friday
• 9 a.m. to 6 p.m. Saturday
• No construction on Sunday
The hours of construction may be modified by the Community
Development Director upon a determination that unusually loud
construction activities are having a significant impact on the
neighbors.
Failure to comply with the above-described hours of operation may
result in withholding of inspections and possible construction
prohibitions, subject to the review and approval of the Planning
Commission.
37. Prior to the final inspection, the applicant shall submit a written
BP
BS
statement from a registered civil engineer that all work has been
completed and is in full compliance with the approved plans and
the Uniform Building Code (UBC).
City Engineer
Site Specific Conditions
Public Improvements:
38. EI Camino Real. Full frontage improvements are required with this
BP
PW
development from the southerly project boundary to San Diego
Way. These include pave out for additional travel lanes with
adequate width for bicycles, curb, gutter, landscaping and
sidewalk. The project shall install &foot landscape strip at the
street frontage with a 5 -foot sidewalk behind it. The entire surface
of EI Camino Real will be restriped for bicycles lanes and two travel
lanes in both directions and a center turn lane. The landscaping on
EI Camino Real shall be irrigated, maintained and cared for by this
project.
The asphalt will transition back to the existing edge of pavement at
the south end of the project at a 5:1 ratio. Public Improvement plans
shall be submitted detailing the design. Cross sections shall be
submitted detailing the existing and proposed cross fall on EI Camino
Real.
39. San Diego Way. Full frontage improvements are required with this
BP
PW
development from the southerly project boundary to EI Camino
Real. These include pave out, which will allow travel lanes in each
Conditions of Approval /
Timing
Responsibility
Mitigation
Mitigation Monitoring Program
/Monitoring
Measure
PS: Planning Services
BL: Business
BS: Building Services
9190 San Diego Way
License
FD: Fire Department
Southside Villas
GP: Grading Permit
BP: Building Permit
PD: Police Department
CE: City Engineer
CUP 2003-0095 (Amendment)
FI: Final Inspection
TO: Temporary
WW: Wastewater
CA: City Attorney
Occupancy
F0: Final
Occupancy
direction with room for bicycles and no parking. A 5 foot sidewalk
will be constructed from the southerly project property line to EI
Camino Real.
Traffic Calming features shall be installed at the two project entrances
on San Diego Way, subject to the approval of the City Engineer.
40. Intersection of San Diego Way and EI Camino Real. The
BP
PW
intersection will be raised and realigned to be perpendicular to EI
Camino Real. The intersection will be restriped to allow for left and
right hand turn pockets onto EI Camino Real.
41. All public improvements shall be constructed in conformance with
BP
PW
the City of Atascadero Engineering Department Standard
Specifications and Drawings or as directed by the City Engineer.
Drainage:
42. Drainage calculations are required per section 5 of Atascadero
BP
PW
Engineering Standards. The "Retention Areas" will be sized for the
detention of the 50 year developed storm runoff, while metering out
the 2 year undeveloped storm runoff. The offsite storm water flows
will be allowed to be passed through the project undetained in
drainage easements. The offsite flows and the detained onsite
flows must be released down stream in the same location,
concentration and pattern as historic flows were released, unless
the downstream owner provide written approval of a deviation.
43. Drainage calculations shall be produced considering all areas
BP
PW
tributary to this property. These calculations shall be in
conformance the City of Atascadero Engineering Standards.
Submit calculations to support the design of any structures or
pipes. Closed conduits shall be designed to convey the 10 -year
flow with gravity flow; the 25 -year flow with head, and provide safe
conveyance for the 100 -year overflow.
44. A Storm Water Pollution Prevention Plan shall be produced and
BP
PW
approved by the Regional Water Quality Control Board and the City
of Atascadero. These plans shall recommend mitigation measure
during and after construction to eliminate point and non point
source pollution. The use on onsite grading feature to pond and
percolate storm water is recommended. A filter system, mechanical
or non, shall be installed with this project. This system shall comply
with the intent of National Pollution Discharge Elimination System,
Phase II requirements.
45. Obtain approval by the City Engineer of the grading & drainage
BP
PW
plan and the storm drain design & facilities.
46. Acquire drainage easements where needed. Drainage shall cross
BP
PW
lot lines only where a drainage easement has been provided.
Conditions of Approval /
Timing
Responsibility
Mitigation
Mitigation Monitoring Program
/Monitoring
Measure
PS: Planning Services
BL: Business
BS: Building Services
9190 San Diego Way
License
FD: Fire Department
Southside Villas
GP: Grading Permit
BP: Building Permit
PD: Police Department
CE: City Engineer
CUP 2003-0095 (Amendment)
FI: Final Inspection
TO: Temporary
WW: Wastewater
CA: City Attorney
Occupancy
F0: Final
Occupancy
47. Concentrated drainage from off-site areas shall be conveyed
BP
PW
across the project site in drainage easements.
Transit:
48. Bus stop with shelter shall be installed on EI Camino Real (south
BP
PW
bound) along the EI Camino real Frontage, per the Public Works
Director.
Wastewater:
49. This project proposes a sewage lift station. This lift station will meet
BP
PW
the following criteria:
■ Sewer lift stations, force mains, gravity mains, laterals and other
sewer facilities shall be privately owned and maintained.
■ Catalogue cuts of equipment that will be installed the lift station
shall be submitted and approved by the Director of Public Works.
■ Lift stations shall be installed with alarm dialers programmed to
notify qualified maintenance personnel when malfunctions occur.
■ Developer shall submit a lift station emergency contingency plan
that addressed protection of public health and the environment
from sewage spills and prolonged power outages.
■ Lift Station shall be equipped with duplex pumps.
50. Drainage piping serving fixtures which have flood level rims located
BP
PW
below the elevation of the next upstream manhole cover of the
public or private sewer serving such drainage piping shall be
protected from backflow of sewage by installing an approved type
backwater valve Fixtures above such elevation shall not discharge
through the backwater valve.
51. The sewer force main crossing EI Camino Real shall cross
BP
PW
perpendicular in the right of way.
52. All sewer main taps will be done by the City of Atascadero. The
BP
PW
developers shall pay a sewer tap fee.
53. Sewer connection permit shall be issued separately (from building
BP
PW
permit) after public sewer extension has been completed and has
received a satisfactory final Public Works inspection. Final project
inspection shall be contingent upon completion of the public sewer
extension and Public Works final inspection.
Solid Waste Conditions:
54. Atascadero Waste Alternative shall approve the location, size and
BP
PW
design of all solid waste facilities. The facilities shall include room
for recycling and green waste containers. The location of the
facilities will take into account the collection of the solid waste.
Conditions of Approval /
Timing
Responsibility
Mitigation
Mitigation Monitoring Program
/Monitoring
Measure
PS: Planning Services
BL: Business
BS: Building Services
9190 San Diego Way
License
FD: Fire Department
Southside Villas
GP: Grading Permit
BP: Building Permit
PD: Police Department
CE: City Engineer
CUP 2003-0095 (Amendment)
FI: Final Inspection
TO: Temporary
WW: Wastewater
CA: City Attorney
Occupancy
F0: Final
Occupancy
Atascadero Mutual Water Company
55. Prior to the start of construction, , the applicant shall submit plans
BP
BS
for review and approval by AMWC for all existing and proposed
water distribution facilities that provide water service to the
proposed Development. The plans shall show all facilities required
for fire protection. The plans shall show all cross -connection
devices required to isolate the fire protection and landscape
irrigation systems from the domestic water system.
56. Prior to the issuance of building permits, the applicant shall obtain
BP
BS
a "Will Serve" letter from the Atascadero Mutual Water Company
for the newly created Lots.
57. Prior to the start of construction, the applicant shall pay all
BP
BS
installation and connection fees required by the Atascadero Mutual
Water Company.
58. All water distribution facilities shall be constructed in conformance
BP
BS
with Atascadero Mutual Water Company standards, policies and
approved procedures. All cross -connection devices shall be
constructed in conformance with AWWA and Department of Health
Services standards.
Mitigation Measures
BP
PS, BS, CE
1.c.1
Mitigation Measure 1.c.1: The following landscape mitigations shall apply:
■ Development along EI Camino Real shall be buffered with an
informal landscape theme to include groupings of shade and
accent trees. Evergreen shall be utilized where there is heightened
visibility of the project from EI Camino Real.
■ Fencing surrounding the private park space and the adjacent
wetland areas shall be transparent wrought iron and shall be
integrated with the final landscape plan subject to staff approval.
■ Development along San Diego Way will include street trees placed
30 feet on center, landscaped common open space area, and an
appropriately landscaped pedestrian project entrance.
• The project shall include landscaping of all common areas,
including slopes, common open space areas, and building
frontages.
■ Parking lot shade trees shall be provided within landscape fingers
and curbside landscape planters as shown in Exhibit 5. Trees shall
be large canopy trees and shall be of a scale appropriate to the
project.
Conditions of Approval /
Timing
Responsibility
Mitigation
Mitigation Monitoring Program
/Monitoring
Measure
PS: Planning Services
BL: Business
BS: Building Services
9190 San Diego Way
License
FD: Fire Department
Southside Villas
GP: Grading Permit
BP: Building Permit
PD: Police Department
CE: City Engineer
CUP 2003-0095 (Amendment)
FI: Final Inspection
TO: Temporary
WW: Wastewater
CA: City Attorney
Occupancy
F0: Final
Occupancy
■ All trees shall be 15 gallon size or greater and shall be double
staked.
Mitigation Measure 1.c.2: The proposed apartments shall include a variety
BP
PS, BS, CE
1.c.2
of earth -tone paint and roof colors designed to blend with the surrounding
environment and reduce the potential for reflected light and glare.
Mitigation Measure 1.c.3: Building architecture shall include features that
BP
PS, BS, CE
1.c.3
emphasize vertical elements and minimize the horizontal nature of the
buildings. Such features are to be of exceptionally high design quality per
General Plan Land Use Policy 2.1.2 and shall include changes in materials,
facade undulation, and vertically emphasized window elements; or similar
treatments.
Mitigation Measure 1.d: All lighting shall be designed to eliminate any off
BP
PS, BS, CE
1.d.
site glare. All exterior site lights shall utilize full cut-off, "hooded" lighting
fixtures to prevent offsite light spillage and glare. Building mounted fixtures
shall be designed to direct light downward. Any parking lot lighting shall be
low bollard style lighting or decorative pole lighting designed to be a
maximum of 14 feet in height. Lighting of the parking area shall be
integrated with proposed landscaping and/or covered parking elements.
Lighting at the rear of the proposed buildings shall be limited to low level
building mounted fixtures and shall be designed to produce a zero
footcandle reading at the property line.
Conditions of Approval /
Mitigation Monitoring Program
9190 San Diego Way
Southside Villas
CUP 2003-0095 (Amendment)
Timing
BL: Business
License
GP: Grading Permit
BP: Building Permit
FI: Final Inspection
TO: Temporary
Occupancy
F0: Final
Occupancy
Responsibility
/Monitoring
PS: Planning Services
BS: Building Services
FD: Fire Department
PD: Police Department
CE: City Engineer
WW: Wastewater
CA: City Attorney
Mitigation
Measure
Mitigation Measure 3.b: The project shall be conditioned to comply with all
BR GP
PS, BS, CE
3.b
applicable District regulations pertaining to the control of fugitive dust (PM -
10) as contained in sections 6.3, 6.4 and 6.5 of the April 2003 Air Quality
Handbook.
Section 6.3: Construction Equipment
■ Maintain all construction equipment in proper tune according to
manufacturer's specifications.
■ Fuel all off-road and portable diesel powered equipment, including but
not limited to bulldozers, graders, cranes, loaders, scrapers, backhoes,
generator sets, compressors, auxiliary power units, with ARB certified
motor vehicle diesel fuel (Non -taxed version suitable for use off-road).
■ Maximize to the extent feasible, the use of diesel construction
equipment meeting the ARB's 1996 or newer certification standard for
off-road heavy-duty diesel engines.
■ Install diesel oxidation catalysts (DOC), catalyzed diesels particulate
filters (CDPF) or other District approved emission reduction retrofit
services (Required for projects grading more than 4.0 acres of
continuously worked area).
Section 6.4: Activity Management Techniques
■ Develop a comprehensive construction activity management plan
designed to minimize the amount of large construction equipment
operating during any given time period.
• Schedule of construction truck trips during non -peak hours to reduce
peak hour emissions.
■ Limit the length of the construction workday period, if necessary.
■ Phase construction activities, if appropriate.
Conditions of Approval /
Mitigation Monitoring Program
9190 San Diego Way
Southside Villas
CUP 2003-0095 (Amendment)
Timing
BL: Business
License
GP: Grading Permit
BP: Building Permit
FI: Final Inspection
TO: Temporary
Occupancy
F0: Final
Occupancy
Responsibility
/Monitoring
PS: Planning Services
BS: Building Services
FD: Fire Department
PD: Police Department
CE: City Engineer
WW: Wastewater
CA: City Attorney
Mitigation
Measure
(Continued from above)
GP
PS, BS, CE
3.b
Section 6.5: Fugitive PM10
All of the following measures shall be included on grading, demolition and
building plan notes:
A Reduce the amount of the disturbed area where possible.
B. Use of water trucks or sprinkler systems in sufficient quantities to
prevent airborne dust from leaving the site. Increased watering
frequency would be required whenever wind speeds exceed 15 mph.
Reclaimed (non -potable) water should be used whenever possible.
C. All dirt stock -pile areas should be sprayed daily as needed.
D. Permanent dust control measures identified in the approved project re -
vegetation and landscape plans should be implemented as soon as
possible following completion of any soil disturbing activities.
E. Exposed ground areas that are plann4ed to be reworked at dates
greater than one month after initial grading should be sown with a fast -
germinating native grass seed and watered until vegetation is
established.
F. All disturbed soil areas not subject to re -vegetation should be stabilized
using approved chemical soil binder, jute netting, or other methods
approved in advance by the APCD.
G. All roadways, driveways, sidewalks, etc, to be paved should be
complete as soon as possible. In addition, building pads should be laid
as soon as possible after grading unless seeding or soil binders are
used.
H. Vehicle speed for all construction vehicles shall not exceed 15 mph on
any unpaved surface at the construction site.
I. All trucks hauling dirt, sand, soil, or other loose materials are to be
covered or should maintain at least two feet of freeboard (minimum
vertical distance between top of load and top of trailer) in accordance
with CVC Section 23114.
J. Install wheel washers where vehicles enter and exit unpaved roads onto
streets, or was off trucks and equipment leaving the site.
K. Sweep streets at the end of each day if visible soil material is carried
onto adjacent paved roads. Water sweepers with reclaimed water
should be used where feasible.
L. The contractor or builder shall designate a person or persons to monitor
the dust control program and to order increased watering, as
necessary, to prevent transport of dust off site. The name and
telephone number of such persons shall be provided to the APCD prior
to land use clearance for map recordation and land us a clearance for
finish grading of any structure.
Mitigation Measure 4.a: The project shall be conditioned to comply with all
BP, GP
PS, BS, CE
4.a
applicable regulations developed by Althouse and Mead, Inc. in their
biological review, dated June 13, 2003 (Attachment 6).
Conditions of Approval /
Mitigation Monitoring Program
9190 San Diego Way
Southside Villas
CUP 2003-0095 (Amendment)
Timing
BL: Business
License
GP: Grading Permit
BP: Building Permit
FI: Final Inspection
TO: Temporary
Occupancy
F0: Final
Occupancy
Responsibility
/Monitoring
PS: Planning Services
BS: Building Services
FD: Fire Department
PD: Police Department
CE: City Engineer
WW: Wastewater
CA: City Attorney
Mitigation
Measure
Mitigation Measure 4.b.1: The project shall be conditioned to Comply with all
BP, GP, CA
PS, BS, CE
4.b.1
applicable regulations developed by Althouse and Mead, Inc. in their
biological review, dated June 13, 2003, pertaining to building location and
wetland rehabilitation methods. Implementation of the following mitigation
measures prior to, during, and following site construction will serve to avoid
and/or minimize adverse indirect impacts to Waters of the U.S. and wetlands
within the proposed project area:
A Buildings 124/125 and 126/127 shall be relocated, eliminated, and/or
downsized to avoid significant disturbance of the designated wetland
area. The applicant will be required to comply with all requirements and
regulations set forth by governing state agencies and shall obtain the
necessary permitting as discussed below.
B. Signage shall be placed at the pedestrian pathway entrance to the
wetlands area informing users of the sensitive nature of the wetlands
habitat.
C. The applicant shall provide a full biologist report, prior to the entitlement
hearing, that identifies all sensitive habitats on and adjacent to the
project site, and certifying the proposed development plan in regards to
wetland mitigations.
D. The project applicant shall retain a qualified biologist to conduct a pre -
construction survey of the on-site wetlands area and to report the
survey results to the City. This biologist shall also place protective
fencing at the protected wetlands boundary to ensure that construction
activities do not impact the noted areas. A note to this effect shall be
placed on the approved construction/grading plans with the provision
that CDFG shall be notified if the pre -construction survey finds
additional wetland habitat on-site, and that construction work is the area
shall not proceed without specific direction from the CDFG.
E. A qualified biologist shall be present during phases of construction that
are conducted adjacent to the identified wetland habitat. The biologist
shall submit regular reports to the Community Development Department
verifying the integrity of the impacted areas. Upon project completion
and prior to final occupancy a final status report shall be prepared by
the project biologist certifying that the stated wetland protection and
mitigation measures were implemented and that the construction -
related protection and enhancement measures are no longer required.
F. Per recommendations set forth in the prepared biology review (Althouse
and Mead, Inc), the applicant shall contact the Army Corps of Engineers
prior to permit issuance and shall request authorization to install
culverts, impact degraded wetlands, and create functional wetlands
under Nationwide Permits, NW #7 Outfall Structures, NW #18 Minor
Discharges, and NW #27 Stream and Wetland Restoration Activities.
Conditions of Approval /
Timing
Responsibility
Mitigation
Mitigation Monitoring Program
/Monitoring
Measure
PS: Planning Services
BL: Business
BS: Building Services
9190 San Diego Way
License
FD: Fire Department
Southside Villas
GP: Grading Permit
BP: Building Permit
PD: Police Department
CE: City Engineer
CUP 2003-0095 (Amendment)
FI: Final Inspection
TO: Temporary
WW: Wastewater
CA: City Attorney
Occupancy
F0: Final
Occupancy
G. Per recommendations set forth in the prepared biology review (Althouse
BP, GP
PS, BS, CE
4.b.1
and Mead, Inc), the applicant shall develop a wetland mitigation site at
a ration of 2:1, based on anticipated ratios required by the Army Corps
of Engineers, which shall be located adjacent to the established
wetlands at the southerly border of the subject property and which will
be located in the area of the existing degraded wetlands habitat.
Mitigation Measure 5.b.1 : Should any cultural resources be unearthed
GP
PS, BS, CE
5.b.2
during site development work, the provisions of CEQA -Section 15064.5, will
be followed to reduce impacts to a non-significant level.
Mitigation Measure 6.b: The grading permit application plans shall include
BP, GP
PS, BS, CE
6.b
erosion control measures to prevent soil, dirt, and debris from entering the
storm drain system during and after construction. A separate plan shall be
submitted for this purpose and shall be subject to review and approval of the
City Engineer at the time of Building Permit application.
Mitigation Measure 6.c.: A soils report shall be required to be submitted with
GP
BS
6.c
a future building permit by the building department.
Mitigation Measure 8.e.f.1: Points of concentrated drainage through the
GP
PS, BS, CE
8.e.f.1
existing wetlands areas shall be addressed by the project biologist and
engineer, and subject to review and approval as identified in the Biology
section of this initial study. All proposed drainage shall be subject to the
approval of the City Engineer and shall be designed to City standards. All
site runoff shall be retained on site through the provision of on-site drainage
basins.
Mitigation Measure 8.e.f.2: A Stormwater Pollution Prevention Plan
GP
PS, BS, CE
8.e.f.2
(SWPPP)/Erosion Control Plan shall be submitted and approved by the City
Engineer prior to the issuance of the building permit. The plan shall include
storm water measures for the operation and maintenance of the project for
the review and approval of the City Engineer. The Building Permit
application plans shall identify Best Management Practices (BMPs)
appropriate to the uses conducted on site that effectively prohibit the entry of
pollutants into storm water runoff.
Mitigation Measure 8.e.f.3: The developer is responsible for ensuring that
BP, GP
PS, BS, CE
8.e.f.3
all contractors are aware of all storm water quality measures and that such
measures are implemented. Failure to comply with the approved
construction Best Management Practices will result in the issuance of
correction notices, citations, or stop orders.
Conditions of Approval /
Timing
Responsibility
Mitigation
Mitigation Monitoring Program
/Monitoring
Measure
PS: Planning Services
BL: Business
BS: Building Services
9190 San Diego Way
License
FD: Fire Department
Southside Villas
GP: Grading Permit
BP: Building Permit
PD: Police Department
CE: City Engineer
CUP 2003-0095 (Amendment)
FI: Final Inspection
TO: Temporary
WW: Wastewater
CA: City Attorney
Occupancy
F0: Final
Occupancy
Mitigation Measure 11.d: All construction activities shall comply with the
GP
PS, BS, CE
11.d
City of Atascadero Noise Ordinance for hours of operation, and as follows:
Construction activities shall be limited to the following hours of operation:
• 7 a.m. to 7 p.m. Monday through Friday
• 9 a.m. to 6 p.m. Saturday
• No construction on Sunday
Further, particularly loud noises shall not occur before 8 a.m. on weekdays
and not at all on weekends.
The hours of construction may be modified by the Community Development
Director upon a determination that unusually loud construction activities are
having a significant impact on the neighbors.
Failure to comply with the above-described hours of operation may result in
withholding of inspections and possible construction prohibitions, subject to
the review and approval of the Community Development Director.
A sign shall be posted on-site with the hours of operation and a telephone
number of the person to be contacted in the event of any violations. The
details of such a sign shall be approved by staff during the Grading
Plan/Building Permit review process.
Mitigation Measure 14.a.b: The project shall include a tot lot within the
BP, GP
PS, BS, CE
14.a.b
communal open space area at the southern border of the site. The tot lot
shall at a minimum include a commercial -grade swing set, slide, climbing
apparatus or similar equipment on a soft surface designed for the safety and
enjoyment of young children. The tot lot shall include pedestrian connection
from throughout the project and shall include durable seating arrangements
for adults and children. The tot lot shall be landscaped and shall include
shade trees.
Mitigation Measure 15.a.b.1 : Per the provided traffic study, the project shall
GP
PS, BS, CE
15.a.b.1
include the construction of full frontage improvements along San Diego Way
and EI Camino Real as approved by the City Engineer and per standards
listed in the General Plan Circulation Element. Improvements are to include:
■ Widening of EI Camino Real to allow for 2 southbound travel lanes and
class 2 bike facilities.
■ Widening of San Diego Way to a width of 24 feet to allow for a total of 2
travel lanes.
■ Curb, gutter, and sidewalk improvements along EI Camino Real and
San Diego Way.
Conditions of Approval /
Timing
Responsibility
Mitigation
Mitigation Monitoring Program
/Monitoring
Measure
PS: Planning Services
BL: Business
BS: Building Services
9190 San Diego Way
License
FD: Fire Department
GP: Grading Permit
PD: Police Department
Southside Villas
BP: Building Permit
CE: City Engineer
CUP 2003-0095 (Amendment)
FI: Final Inspection
TO: Temporary
WW: Wastewater
CA: City Attorney
Occupancy
F0: Final
Occupancy
Mitigation Measure 15.a.b.2: A Bus turnout shall be provided along the EI
BP, GP
PS, BS, CE
15.a.b.2
Camino Real frontage. Facilities shall include a 5 -foot width bus turnout and
shelter. The shelter shall be a City Standard shelter and shall be subject to
the approval of the City Engineer.
Mitigation Measure 16.c.1: Proposed drainage into the existing wetlands
BP, GP
PS, BS, CE
16.c.1
areas shall be addressed by the project biologist and engineer, and subject
to review and approval as identified in the Biology section of this initial study.
Mitigation Measure 16.c.2: Drainage retention basins shall be included in the
BP, GP
PS, BS, CE
16.c.2
project site and shall be subject to the approval of the City Engineer. Basins
shall be designed to accommodate all site runoff and each basin will be
maintained as designed.
EXHIBIT B: Site Plan
1(11�j,j1 ••::�.,:.:e_::o, a: ....,.w"�i.
ia! .may.
itl� 4 • �,w.,n .
/,'7£G 47Q4�6C.7
lkvm 09)30 N'0'9 6616
SV"^ 33911wno9
I
id
EXHIBIT C: Grading and Drainage Plan
57
15
.i �� i,J�N� d JIB• � �1
�4 � � :. S"'ter' lt:ll�liilIii ,I11 ,It i�
jSjj Sp1jpt!}
��i t •R 14�� �.' ` 1�:+ t OV6Gt�E7JOE�G�041 O�i�GtiyJv�G�Q�iob,
i}
U xnu I .l vRr i
Or I
to
EXHIBIT E: Elevations
EXHIBIT F: Lower Floor Plan
fit
9 r
90,K6 Y� 'S31IX12! OSvd �
AVM 00710 NVS 0616 n N
SVI M 301SIUFX s g Q
alwas.nlnrv+w� � a �'
Ali
C�
_
= c =
EXHIBIT G: Upper Floor Plan
--
-;'_Irl v �.., '�wK rN:r ora +w.w•�w n .qy 91,6 VO 'S7180M OSVd a N
3 66 1 i
=,'if• ,s,,,o .
AVM O'J3I6 isi 0616
u N
r' I ��!rV arra . sv rile 7dVL* ntV' I • tF Q
ii bCTJ QTtlVd.RJO NYid 1
f
U-
EXHIBIT H: Accessory Structure Designs
��'•� 1N +'M7 7 '1.1 Ott "OOWM M yq
1 j 9►bf: fi rU 'S31JUti USVd
1 'rl,tl 3__1_1__L n I.VAA 00310 Nv5 0616 _ I,
!'Itj�� : w.w • ;YIIVti 701SNMDS i t b a l Q
gym. Z is \ '� �_.._` , •• �;+-
t
I� I Cn
J
s
lowW1 -
men
Q 1
y lei
0 '4 UP
Z
:XHIBIT I: Color and Materials Board
P-2
CP -1/P-1
• ARCHITECTURE •
• GRAPHICS •
• DESIGN •
A R C H 1 T E C T
KEN M. NAGAHARA 610 101h SUoet, SuMe A
P-3 Prnopat Paso Robles. CA 93446
Ph 48051 2385501 Fx (806) 239.5869
COLOR SCHEDULE
SYM
MATERIAL MANUFACTURER
COLOR
RP -1
CONCRETE "S" TILE ROOF HANSON
40% MARIGOLD BLEND R-419
40% BALBOA BLEND R-420
20% REDWOOD BLEND R-542
CP -1
CEMENT PLASTER LA HABRA
TO MATCHE FRAZEE "PALE
ALL EXTERIOR PLASTER
CHAMOIS" #7300W
P-1
PAINT - EXPOSED WOOD FRAZEE
"BASQUE BROWN" #8265A
(INCLUDING TRELLIS POST, CARPORT POST, TRASH ENCLOSURE DOORS, &
EXTERIOR DOORS)
P-2
PAINT - EXPOSED WOOD FRAZEE
"PALE CHAMOIS" #7300W
(INCLUDING FASCIA. OUTRIGGER, TRELLIS BEAMS & RAFTERS)
P-3
PAINT - METAL RAILING FRAZEE
"DOMINO" FLAT BLACK #AC141N
(INCLUDING GUARDRAILS AND PERIMETER FENCE RAILING)
VP -1
(4) - 4" DIAMETER CLAY VENT PIPE AT GABLE ENDS
EXHIBIT J: Preliminary Biological Assessment
Althouse and Mead
ALTHOUSE AND MEADE, INC.
BIOLOGICAL AND ENVIRONMENTAL SERVICES
1875 Wellsona Road • Paso Robles, CA 93446 • Telephone (805) 467-1041 - Fax (805) 467-1021.
VIA FACSIMILE
June 13, 2003
274.1
Steve McHarris 461-5036
Planning Services Manager
City of Alascadero
6500 Palma Avenue
Atascadero, CA 93422
Lynm Dec Altho=, RLD.c.
(905)459-!660
Danis) E, Meade, Ph.D.
(805) 705-2479
Re: South Side Villas, 9190 San Diego Road, JRM Development Proposal
APN 045-352-002,3,4,6,7
Dear Steve:
Yesterday I looked at the proposed development between San Diego Road and EI
Camino Real. I identified two small wetlands along the property boundary as shown on
the attached map. The total area of the two wetlands is approximately 430 square feet.
One wetland is at the terminus of a small culvert that drains water from the mobile home
park north of San Diego Road and from the upslope area- The second wetland is in the
comer of the lawn area, down slope from a septic tank vent. Both wetlands are
dominated by rabbit's -foot grass (Polypogon monspeliewls) and Italian ryegrass (Lolium
mulriflorum). The wetland at the terminus of the culvert also contains vetch (Vicia
sattva), yellow starthistle (Centauria solstitfalis), and other non -wetland species.
The remainder of the project boundary adjacent to wetlands on the parcel south of the
subject property, is dominated by fescue and blue -grass lawns and back yard structures
(i.e., above -ground pool, landscaping, and fences) that have been in place since the early
1970's.
Tim Roberts and I discussed the appropriate location for a wetland mitigation site,
anticipating a 2:1 mitigation ratio from the Army Corps. By moving buildings 125 and
126 away from one another, there is plenty of room for creating wetland habitat adjacent
to the neighbor's existing wetland.
I left a message for Corrie Veenstra from the US Army Corps of Engineers this morning
stating that I had observed two small wetlands adjacent to the adjoining parcel she looked
at last week- I recommend that the applicant notify the Corps of Engineers and request
authorization to install culverts, impact degraded wetlands, and create functional
wetlands under Nationwide Permits NW #7, Outfall structures, NW #18, Minor
Disharges; and, NW#27, Stream and Wetland Restoration Activities.
Sincerely,
LynneDee Althouse
Copy: Tim Roberts via fax — 238-6148
EXHIBIT J: Preliminary Biological Assessment
Althouse and Mead
Althouse and Meade, Inc.
Attachment — Portions of map sent via fax by Tim Roberts (not to scale)
CIean Water Act Section 404 Wetlands,
�side the fenceline are contiguous with
�(Zwetlands to the south, on the adjoining
parcel. Wetland sites are indicated by ojvals.
,
let
71
\ � \ -4it
it
`r a
ZB -tl $bT9 9RZ 9H Ib33N LSH3 Sl>J3Htl}! LIV 92:80 £BBZ-£L-Nllf
Soath Side Villas 274.1 2
EXHIBIT J: Preliminary Biological Assessment
Althouse and Mead
ALTHQUSE AND M MADE, INC.
BIOLOGICAL AND EWIRONMEWAL SERVICES
1875 Wellso m Road + Pwo Robles, CA 93446 • TeIrphow (805)167-1041 • Fax(8t15) 467-1021
FACSIMILE TR"SMMAL Lynne Dee Atdnase. Pb.D e.
(305)459-1W
BMW E. me dc. Ph.D.
July 28, 2003 cis) ros zrr9
2743
Peter Josserand
809 13'° Street
Paso Robles, CA 93446
238-5313
FAX 238-5373
Re: San Diego Way Apartments — Site Plan Review
Dear Peter.
We recommend the following information be included on a site plan for submittal to the
US Army Corps of Engineers and to the CA Department of fish and Game for review
• Grading plan with wetland areas clearly shown.
• Drainage plan (model flows from 2 yr to 100 yr storms in each drainageway) with
ordinary high water mark clearly indicated were drainage modifications are
proposed-
■ Cross-sections and details of drainageways and proposed culvert installations.
• Watershed boundary map-
The site plan you submitted to our office today does not show topography or drainages
(with wetland areas clearly identified).
1 recommend that we notify the Corps of Engineers and request authorization to install
culverts, impact degraded wetlands, and create functional wetlands. The Corps process
takes from 90 days to over a year, depending on endangered species issues. The Corps
will require a wetland delineation and may require additional surveys following
Endangered Species Act Section 7 consultation with the US Fish and Wildlife Service.
Your project will need a Clean Water Act 401 certification from the Regional Water
Quality Control Board before the Corps penmit it fully authorized -
Your project may also require a permit £rot the CA Department of Fish and Game to
modify the location and function of wetlands.
Sincerely, �j,�/
�Yn�&z Althouse
EXHIBIT K: Follow-up Biological Assessment
Althouse and Mead
ALTHOUSE AND MEADE, INC.
Bt()tAxil('AL AND INVIRONMENfAL SLRVICLI — —
1873 Wdhona Rauf • Paso Robles. CA 93446 • Tek"x (1105) 467-1041 • Fax MIS) 467-1021
L\me Ne Akh3se. %I S
k$05) 419-16611 i -cU)
It1ncdeo4Aihwarkw6e cvn
May 20, 2004 tk.d a scale. Ph D
2741 (1107 i 70!�-24'4 �"11)
dmAAdnuuandnrane :�n
Kelly Gleason
City of A.tascadero
Community Development Depmtment/Public Works
6500 Palma Avenue
Atascadero, CA 93422
Re. CUP 2003-0095
9190 San Diego Way
Dear Kelly
This letter respond, to corrections released on April 26, 2004, items 4 and S
The wetland mitigation area is designed to mitigate for impacts to degraded wetlands on
the project site The wetland mitigation area will be vcbctatcd with native species and
will have significantly higher functions and values than the existing wetlands on site.
The wetland mitigation area is part of the L!.S Army Corps of Engineers Nationwide 27
and 39 permits, in process The wetland on the subject property connects with a much
larger wetland to the south, part of the Paloma Creek drainage system.
Pedestrian access is being c widinatcd between this project and the project to the south
( 1'he Villages al Dove Creek) Pedestrian access will pass from the park, through the fire
access road now El Camino Real, toward the wetland The path will be set back front the
wetland so the area between the path and the wetland can be planted with a "bramble -
berry hedge" of California wild roses and blackberries
Pedestrian a"ess is not possible in the wetland mitigation arca for three reasons
1 The wetland will be boggy most of the year.
2 The border of the wetland will be surrounded on three sides by a retaining
wall covered with blackberries.
3 We need to inhibit human access to the wetland due to the possible presence
of federal threatened species, California rcd•legged frog
Attached is a copy of the mitigation planting plan prepared by C1P Productions Inc
(Atascadero) Also attached is a portion of the grading, drainage and site utility plan
prepared by Roberts Engineering (Templeton) ]'he blue line on the grading plan
indicates the location of the existing wetlands on the subject parcel with respect to the
adjacent parcel to the south The proposed wetland mitigation area is correctly located to
provide an extension of the existing wetland.
EXHIBIT K: Follow-up Biological Assessment
Althouse and Mead
:liriiuu.rc•uad.i%a1k', inc.
The retaining wall adjacent to the %wdand mitigation area is useful for three reasons,
I 1'he wall inhibits California red -legged frogs (if present) from entering the
development
'_ The wall inhibits pedestrian access to the wetland.
3 fhe design of the wetland mitigation area requires a wall in order to maintain
the building pads for the cond(nniniums.
As 1 understand the revised plan, the proposed wall along the property boundary is set
back from the property botmdary by three feet It is important that the wall be set back
from the property boundary so there is enough room for landscape matenals ( native trees
and shrubs), irrigation, and maintenance activities.
The revised grading, drainage and site utility plan provides suitable mitigation for
wetland impacts. Picase notify me of changes that are made to the site grading, drainage
and landscape plans that may affect the wetland mitigation arca or the wetland south of
the subject parcel
Sincerely,
ynn Althousc
Attachments Mitigation Planting Plan prepared by CJP Producxions, Inc
Portion of Grading, Drainage and Site Utility Plan prepared by Roberts
F.nginocring
Copy Peter lc»serand XIII
San Mego N ay CondwNnima
EXHIBIT K: Follow-up Biological Assessment
Althouse and Mead
L J
• J
zz t
S
YNJ
p 1
0C z
�— L_Yoo
lLLJ7J F p« �« L
r2
171
171O i
r
Y p � • o
vQ iO OZ
4 �Z
Y a N <�
a < rv QY
��S pS X�
m •
j{{ 0 <JJ
o r• n • n n � �+ - �
• r -
u
yyz S s o� <a
W, z IN ��«c � O_ .0
U`
4 JS 03 Ne �V Z , J�J oo ot< t?A
L_S qSO �4 <; C� O �<
�Yp Y 2 << yO'O A y(; < l0 mZ
Y 1 �V C vt 7U �U JO •J } �C
UU0 87
x'UU
J q le
RAJ[: 34
<
00
•
EXHIBIT K: Follow-up Biological Assessment
Althouse and Mead
EXHIBIT L: Project Statistical Summary
Area Calculations
Gross Site =
176,694
sq.ft.
Offer Oflkdication
2,824
sq.ft.
Net Site -
174,140
sq.fl.
Badding Footprints
12 Buildings ® 1302
15,624
sq -
fl -30 Buildings (q-? 1048 =
31,440
sq. fl.
Total Footprints =
47,064
%q. ft. 27'0 of net
Parkin
Total Parking & Drives = 55,405 sq.ft. _ 31.8% of net
Carports - 21 x 720 -- 15,120 sq.t1 of total parking
Landscape
Walks & Flatwork - 11,991 sq.ft.
Open arra - 28,556 sq.fi.
Softscapr = 32,767
Lvital I and,apc 71.745 + ft. 41,21`9 of act
Total Building. Parking, and tAnscape -100'/0 of net
EXHIBIT M: Off-site Public Improvement Plan
Attachment 7: Draft Resolution PC 2004-0083
Tentative Tract Map 2004-0052
DRAFT RESOLUTION PC 2004-0083
A RESOLUTION OF THE PLANNING COMMISSION
OF THE CITY OF ATASCADERO APPROVING TENTATIVE
TRACT MAP 2004-0052, TO ALLOW 84 AIRSPACE UNITS ON ONE
COMMON LOT CONSISTENT WITH A MASTER PLAN OF
DEVELOPMENT (CUP 2003-0095)
PN 045-352-0021, 0039 0049 0069 007
(9190 San Diego Way/JRM Enterprises)
WHEREAS, an application has been received from JRM Development (809 13th Street,
Paso Robles, CA 93446), Applicant and Property Owner to consider an amendment to the
Master Plan of Development (CUP 2003-0095) and to consider an application for a
condominium map (TTM 2004-0052) to approve an 84 -unit multifamily development; and,
WHEREAS, the site's General Plan Designation is HDR (High -Density Residential);
and,
WHEREAS, the site's current zoning district is RMF -16 (Residential MultrFamily);
and,
WHEREAS, the Planning Commission has approved an amendment to the Master Plan
of Development (CUP 2003-0095) thereby allowing an eighty-four unit multifamily
development on the site; and,
WHEREAS, the laws and regulations relating to the preparation and public notice of
environmental documents, as set forth in the State and local guidelines for implementation of the
California Environmental Quality Act (CEQA) have been adhered to; and,
WHEREAS, a timely and properly noticed Public Hearing upon the subject Tentative
Tract Map application was held by the Planning Commission of the City of Atascadero at which
hearing evidence, oral and documentary, was admitted on behalf of said application; and,
WHEREAS, the Planning Commission of the City of Atascadero, at a duly noticed
Public Hearing held on July 20, 2004, studied and considered Tentative Tract Map 2004-0052,
after first studying and considering the Mitigated Negative Declaration prepared for the project;
and,
NOW, THEREFORE, the Planning Commission takes the following actions:
SECTION 1. Findings of Approval for Tentative Tract Map, the Planning
Commission of the City of Atascadero finds as follows:
1. The proposed subdivision, as conditioned, is consistent with the General Plan and
applicable zoning requirements.
2. The design and improvement of the proposed subdivision is consistent with the General
Plan and applicable zoning requirements.
3. The proposed subdivision, as conditioned, is consistent with the proposed Master Plan of
Development (CUP 2003-0095).
4. The site is physically suitable for the type of development proposed.
5. The site is physically suitable for the density of development proposed.
6. The design and improvement of the proposed subdivision will not cause substantial
environmental damage or substantially and unavoidably injure fish and wildlife or their
habitat.
7. The design of the subdivision will not conflict with easements acquired by the public at
large for access through, or the use of property within, the proposed subdivision; or
substantially equivalent alternative easements are provided.
8. The proposed subdivision design and type of improvements proposed will not be
detrimental to the health, safety or welfare of the general public.
SECTION 2. Approval. The Planning Commission of the City of Atascadero, in a
regular session assembled on July 20, 2004, resolved to approve Tentative Tract Map (TTM
2004-0052) subject to the following:
EXHIBIT A: Conditions of Approval / Mitigation Monitoring Program.
EXHIBIT B: Off-site improvements
EXHIBIT C: Traffic Calming Study
On motion by Commissioner and seconded by Commissioner
, the foregoing resolution is hereby adopted in its entirety by the following roll call
vote:
AYES:
NOES:
ABSENT:
ABSTAINED:
ADOPTED:
CITY OF ATASCADERO, CA
Bob Kelley
Planning Commission Chairperson
Attest:
Warren M. Frace
Planning Commission Secretary
EXHIBIT A: Conditions of Approval
Resolution PC 2004-0083
TTM 2004-0052
Conditions of Approval /
Timing
Responsibility
Mitigation
Mitigation Monitoring Program
/Monitoring
Measure
PM: Parcel Map
GP: Grading Prmt
PS: Planning Services
9190 San Diego Way
g y
BP: Building Pont
T0: Temporary
BS: Building Services
CE: City Engineer
Southside Villas
occupancy
F0: Final occupancy
CA: City Attorney
AMWC: Atascadero Mutual
CUP 2003-0095 (Amendment)
PI: Public Improvements
Water Company
Planning Services
Standard Planning Conditions
1. The approval of this application shall become final fourteen (14)
Ongoing
PS
days following the Planning Commission approval unless an
appeal to the decision is filed as set forth in Section 9-1.111(b)
of the Zoning Ordinance.
2. Approval of this Tentative Tract Map shall be valid for two years
FM
PS
after its effective date. At the end of the period, the approval
shall expire and become null and void unless an extension of
time is granted pursuant to a written request received prior to
the expiration date, or a final map is recorded with the County
Recorder's Office.
3. The Community Development Department shall have the
FM
PS
authority to approve minor changes to the project that (1) result
in a superior site design or appearance, and/or (2) address a
construction design issue that is not substantive to the
Tentative Tract Map.
4. A final map drawn in substantial conformance with the
FM
PS
approved tentative map, and in compliance with all conditions
set forth herein, shall be submitted for review and approval in
accordance with the Subdivision Map Act and the City's
Subdivision Ordinance.
5. The subdivider shall defend, indemnify, and hold harmless the
Ongoing
CA
City of Atascadero or its agents, officers, and employees
against any claim or action brought to challenge an approval by
the City, or any of its entities, concerning the subdivision.
6. This Tentative Map shall be for an 84 -unit multi -family
Ongoing
PS
condominium development, located on parcel 045-352-002,
003, 004, 006, 007regardless of owner.
Project Specific Conditions
7. Affordable Housing Requirement: The applicant shall set aside
FM
CE/PS
10% of the base density units at the very lowAncome rate, or
20% of the base density units at the low-income rate for a
narinrl of 10 vaarc At laact nna thraa_haHrnnm rinit zhnil ha
Conditions of Approval /
Timing
Responsibility
Mitigation
Mitigation Monitoring Program
/Monitoring
Measure
PM: Parcel Map
GP: Grading Prmt
PS: Planning Services
97 90 San Diego Way
9 y
BP: Building Prmt
TO: Temporary
BS: Building Services
CE: City Engineer
Southside Villas
occupancy
F0: Final Occupancy
CA: City Attorney
AMWC: Atascadero Mutual
CUP 2003-0095 (Amendment)
PI: Public Improvements
Water Company
deed restricted.
8. Workforce Housing
FM
PS/CE
Prior to issuance of building permits, the applicant shall enter into a
legal agreement with the City to reserve 1/2 of the units to residents or
workers within the City of Atascadero, including the affordable units.
The agreement shall include the following provisions:
■ The units shall be offered for rent to residents or workers
within the City of Atascadero for a minimum of 60 -days.
During this time period offers may only be accepted from
Atascadero residents or workers;
■ The applicant shall provide reasonable proof to the City
that at least one of the qualified renters is a resident or
worker within the City Limits of Atascadero;
■ The Atascadero resident or worker restriction shall apply to
the initial rental only;
■ The applicant shall identify which units will be reserved; and
■ The City Attorney shall approve the final form of the
agreement.
City Engineer Standard Conditions
9. Prior to the issuance of building permits the applicant shall
FM
CE
submit plans and supporting calculations/reports including
street improvements, underground utilities, composite
utilities, and grading/drainage plans prepared by a registered
civil engineer for review and approval by the City Engineer.
10. The applicant shall acquire title interest in any off-site land
FM
CE
that may be required to allow for the construction of the
improvements. The applicant shall bear all costs associated
with the necessary acquisitions. The applicant shall also gain
concurrence from all adjacent property owners whose ingress
and egress is affected by these improvements.
11. Slope easements shall be obtained by the applicant as
FM
CE
needed to accommodate cut or fill slopes.
12. Drainage easements shall be obtained by the applicant as
FM
CE
needed to accommodate both public and private drainage
facilities.
13. A preliminary subdivision guarantee shall be submitted for
FM
CE
review in conjunction with the processing of the parcel map.
14. The final map shall be signed by the City Engineer prior to
FM
CE
the map being placed on the agenda for City Council
acceptance.
Conditions of Approval /
Timing
Responsibility
Mitigation
Mitigation Monitoring Program
/Monitoring
Measure
PM: Parcel Map
GP: Grading Prmt
PS: Planning Services
97 90 San Diego Way
9 y
BP: Building Prmt
TO: Temporary
BS: Building Services
CE: City Engineer
Southside Villas
occupancy
F0: Final Occupancy
CA: City Attorney
AMWC: Atascadero Mutual
CUP 2003-0095 (Amendment)
PI: Public Improvements
Water Company
15. Prior to recording the parcel map, the applicant shall pay all
FM
CE
outstanding plan check/inspection fees.
16. Prior to recording the parcel map, the applicant shall set
FM
CE
monuments at all new property corners. A registered civil
engineer or licensed land surveyor shall indicate by certificate
on the parcel map, that corners have been set or shall be set
by a date specific and that they will be sufficient to enable the
survey to be retraced.
17. Prior to recording the parcel map, the applicant shall submit a
FM
CE
map drawn in substantial conformance with the approved
tentative map and in compliance with all conditions set forth
herein. The map shall be submitted for review and approval
by the City in accordance with the Subdivision Map Act and
the City's Subdivision Ordinance.
18. All existing and proposed utility, pipeline, open space, or
FM
CE
other eas ements are to be shown on the final/parcel map. If
there are building or other restrictions related to the
easements, they shall be noted on the final/parcel map. The
applicant shall show all access restrictions on the final/parcel
map.
19. Prior to recording the parcel map, the applicant shall have the
FM
CE
map reviewed by all applicable public and private utility
companies (cable, telephone, gas, electric, Atascadero
Mutual Water Company). The applicant shall obtain a letter
from each utility company indicating their review of the map.
The letter shall identify any new easements that may be
required by the utility company. A copy of the letter shall be
submitted to the City. New easements shall be shown on the
parcel map.
20. In the event that the applicant is allowed to bond for the
FM
CE
public improvements required as a condition of this map, the
applicant shall enter into a Subdivision Improvement
Agreement with the City Council.
21. An engineer's estimate of probable cost shall be submitted
FM
CE
for review and approval by the City Engineer to determine the
amount of the bond.
22. The Subdivision Improvement Agreement shall record
FM
CE
concurrently with the Final Map.
City Engineer
Site Specific Conditions
23. The applicant shall record CC&R's for the subdivision subject to
FM
CE
the review and approval of the City Engineer, City Attorney and
Planning Services. The CC&R's shall identify the maintenance
responsibilities of all private driveways, sewer facilities,
drainage facilities, common parking areas, site lighting,
landscape areas, fencing, and other common facilities. The
CC&R's shall also state that all exterior colors, exterior
materials, yard fencing and site landscaping shall be consistent
with the overall master plan of development.
Conditions of Approval /
Timing
Responsibility
Mitigation
Mitigation Monitoring Program
/Monitoring
Measure
PM: Parcel Map
GP: Grading Prmt
PS: Planning Services
97 90 San Diego Way
9 y
BP: Building Prmt
TO: Temporary
BS: Building Services
CE: City Engineer
Southside Villas
Occupancy
F0: Final Occupancy
CA: City Attorney
AMWC: Atascadero Mutual
CUP 2003-0095 (Amendment)
PI: Public Improvements
Water Company
Public Improvements:
24. EI Camino Real. Full frontage improvements are required
BP
PW
with this development from the southerly project boundary to
San Diego Way. These include pave out for additional travel
lanes with adequate width for bicycles, curb, gutter,
landscaping and sidewalk. The project shall install Woot
landscape strip at the street frontage with a 5 -foot sidewalk
behind it. The entire surface of EI Camino Real will be
restriped for bicycles lanes and two travel lanes in both
directions and a center turn lane. The landscaping on EI
Camino Real shall be irrigated, maintained and cared for by
this project.
The asphalt will transition back to the existing edge of
pavement at the south end of the project at a 5:1 ratio. Public
Improvement plans shall be submitted detailing the design.
Cross sections shall be submitted detailing the existing and
proposed cross fall on EI Camino Real.
25. San Diego Way. Full frontage improvements are required
BP
PW
with this development from the southerly project boundary to
EI Camino Real. These include pave out, which will allow
travel lanes in each direction with room for bicycles and no
parking. A 5 -foot sidewalk will be constructed from the
southerly project property line to EI Camino Real.
Traffic Calming features shall be installed at the two project
entrances on San Diego Way, subject to the approval of the
City Engineer.
26. Intersection of San Diego Way and EI Camino Real. The
BP
PW
intersection will be raised and realigned to be perpendicular
to EI Camino Real. The intersection will be restriped to allow
for left and right hand turn pockets onto EI Camino Real.
27. All public improvements shall be constructed in conformance
BP
PW
with the City of Atascadero Engineering Department
Standard Specifications and Drawings or as directed by the
City Engineer.
Drainage:
28. Drainage calculations are required per section 5 of
BP
PW
Atascadero Engineering Standards. The "Retention Areas"
will be sized for the detention of the 50 year developed storm
runoff, while metering out the 2 year undeveloped storm
runoff. The offsite storm water flows will be allowed to be
passed through the project undetained in drainage
easements. The offsite flows and the detained onsite flows
must be released down stream in the same location,
concentration and pattern as historic flows were released,
unless the downstream owner provide written approval of a
Conditions of Approval /
Timing
Responsibility
Mitigation
Mitigation Monitoring Program
/Monitoring
Measure
PM: Parcel Map
GP: Grading Prmt
PS: Planning Services
97 90 San Diego Way
9 y
BP: Building Prmt
TO: Temporary
BS: Building Services
CE: City Engineer
Southside Villas
occupancy
FO: Final Occupancy
CA: City Attorney
AMWC: Atascadero Mutual
CUP 2003-0095 (Amendment)
PI: Public Improvements
Water Company
deviation.
29. Drainage calculations shall be produced considering all areas
BP
PW
tributary to this property. These calculations shall be in
conformance the City of Atascadero Engineering Standards.
Submit calculations to support the design of any structures or
pipes. Closed conduits shall be designed to convey the 10 -
year flow with gravity flow; the 25 -year flow with head, and
provide safe conveyance for the 100 -year overflow.
30. A Storm Water Pollution Prevention Plan shall be produced
BP
PW
and approved by the Regional Water Quality Control Board
and the City of Atascadero. These plans shall recommend
mitigation measure during and after construction to eliminate
point and non point source pollution. The use on onsite
grading feature to pond and percolate storm water is
recommended. A filter system, mechanical or non, shall be
installed with this project. This system shall comply with the
intent of National Pollution Discharge Elimination System,
Phase II requirements.
31. Obtain approval by the City Engineer of the grading &
BP
PW
drainage plan and the storm drain design & facilities.
32. Acquire drainage easements where needed. Drainage shall
BP
PW
cross lot lines only where a drainage easement has been
provided.
33. Concentrated drainage from off-site areas shall be conveyed
BP
PW
across the project site in drainage easements.
Wastewater:
34. This project proposes a sewage lift station. This lift station will
BP
PW
meet the following criteria:
■ Sewer lift stations, force mains, gravity mains, laterals and
other sewer facilities shall be privately owned and
maintained.
■ Catalogue cuts of equipment that will be installed the lift
station shall be submitted and approved by the Director of
Public Works.
■ Lift stations shall be installed with alarm dialers
programmed to notify qualified maintenance personnel
when malfunctions occur.
• Developer shall submit a lift station emergency contingency
plan that addressed protection of public health and the
environment from sewage spills and prolonged power
outages.
■ Lift Station shall be equipped with duplex pumps.
35. Drainage piping serving fixtures which have flood level rims
BP
PW
located below the elevation of the next upstream manhole
cover of the public or private sewer serving such drainage
Conditions of Approval /
Timing
Responsibility
Mitigation
Mitigation Monitoring Program
/Monitoring
Measure
PM: Parcel Map
GP: Grading Prmt
PS: Planning Services
97 90 San Diego Way
9 y
BP: Building Prmt
TO: Temporary
BS: Building Services
CE: City Engineer
Southside Villas
occupancy
F0: Final Occupancy
CA: City Attorney
AMWC: Atascadero Mutual
CUP 2003-0095 (Amendment)
PI: Public Improvements
Water Company
piping shall be protected from backflow of sewage by
installing an approved type backwater valve Fixtures above
such elevation shall not discharge through the Imckwater
valve.
36. The sewer force main crossing EI Camino Real shall cross
BP
PW
perpendicular in the right of way.
37. All sewer main taps will be done by the City of Atascadero.
BP
PW
The developers shall pay a sewer tap fee.
38. Sewer connection permit shall be issued separately (from
BP
PW
building permit) after public sewer extension has been
completed and has received a satisfactory final Public Works
inspection. Final project inspection shall be contingent upon
completion of the public sewer extension and Public Works
final inspection.
Atascadero Mutual Water Company
39. Prior to the start of construction, , the applicant shall submit
BP
BS
plans for review and approval by AMWC for all existing and
proposed water distribution facilities that provide water
service to the proposed Development. The plans shall show
all facilities required for fire protection. The plans shall show
all cross -connection devices required to isolate the fire
protection and landscape irrigation systems from the
domestic water system.
40. Prior to the issuance of building permits, the applicant shall
BP
BS
obtain a "Will Serve" letter from the Atascadero Mutual Water
Company for the newly created Lots.
41. Prior to the start of construction, the applicant shall pay all
BP
BS
installation and connection fees required by the Atascadero
Mutual Water Company.
42. All water distribution facilities shall be constructed in
BP
BS
conformance with Atascadero Mutual Water Company
standards, policies and approved procedures. All cross -
connection devices shall be constructed in conformance with
AWWA and Department of Health Services standards.
Fire Marshal
43. Provide a letter from the Atascadero Mutual Water Company
BP
FD
stating the minimum expected water available to the site.
Amount available must meet min. requirement specified in
the California Fire Code.
44. Fire lanes shall be delineated to restrict parking as required
BP
BS
by the Fire Authority.
Conditions of Approval /
Timing
Responsibility
Mitigation
Mitigation Monitoring Program
/Monitoring
Measure
PM: Parcel Map
GP: Grading Prmt
PS: Planning Services
97 90 San Diego Way
9 y
BP: Building Prmt
TO: Temporary
BS: Building Services
CE: City Engineer
Southside Villas
Occupancy
CA: City Attorney
F0: Final Occupancy
AMWC: Atascadero Mutual
CUP 2003-0095 (Amendment)
PI: Public Improvements
Water Company
by the Fire Authority.
45. One additional fire hydrant shall be added to the emergency
BP
BS
access area off of EI Camino Real, subject to the approval of
the fire marshal.
EXHIBIT B: Off-site Public Improvements
Resolution PC 2004-0083
TTM 2004-0052
EXHIBIT C: Traffic Calming Study
Resolution PC 2004-0083
TTM 2004-0052
-11' -:6-2004 12:47 P,1 POREPTR ENGINEERING 230 clow P,U.
0=0
orou Ino lnrrr In$ GFOWA 164
t6,27 rNrrdr Avfrur
Srnu rnp. QlJerov Ilt60
Monr1rA11 SOS -688.7614
rmall Oeve QUI -1 nrr
December 29, 2003
Mr. Steven Kahn, PE, LS
Pubic woM Director
City of Atascadero
65DD Palma Averue
Atescadero, CA 93422
Subject: Traff c Calming Along San Diego Wdy — Southside Villas
Dear Mr. Kahn:
OEG Refererr-c 50203
C>roc7 Engineerine, rs oup, Inc (OEG) has prepared tie following analysts o` traffc calmng
options ns requester by the Plann'ng Commission. Two options were to De evaluated. The "irst
ooton was a traffic calminq ooton :o create a comfortable pnyslcai environment to siu v traffic
using San Diego Way. The record ooton was to consider Instaliing an Ai -Way Stop controlled
intersectior at the project drlveeNays.
Traffic Caliming
There are several traffir calming tools that can be used to sow or discourage traffic on a
particutar street. Typical tools include raised Intersectens, curb bulb outs, speed humps,
roundabouts, diverters, chokers, etc.
For this project, the street is already fairly narrow at 34 feet for parking on one side Only. The
Instalation of a roundabout would take too much right of way. Diverters and speed humps are
not appropriate for a connector road between a freeway ramp and the main City street. The
most appropriate tool would be a choker/curb bilb out.
The Intent of this tragic calming tool 's to reduce the paved roadway section over tate basic road
section to narrow the area between curbs. This gNes divers the feding of being squeered and
a.. r...+ n„r,",Jly vnalr1o% <Irwv S -1S rrnh from their orevious speed based actual studies.
Attached to this IettPr are two sketches of how the choker/curb bulb out could look from a
aerial perspective for the north and south project driveways. Once approved, landscaping and
dull engineering/drainage Imes vill be specifically addressed. The intent of the landscaplrsg is
to make it consistent with the proposed project, whsle the civil erg'rteering neetk:d will address
site and roadway drainage issues. Both of these areas are manageable and do not impact the
technical ability to slow tra`fic on Sa 1 Diego Way. Two street lignts have been added per your
request, one at each driveway.
aL-Valma
An Ail -Way Stop controlled Intersection at the project driveways was asked to be consldered to
slaw traffic on San Diego way. Our research has Tound that the Installation of an all -way stop
is not waranted, nor aooropriate, at these locations fur the following reasons.
EXHIBIT C: Traffic Calming Study
Resolution PC 2004-0083
TTM 2004-0052
rr,i I „c i -So . o.
Mr. Steven Kahn
December 19, 2003
rows
Acoording to the federal Highway Administration publications, Manual on Unlfor r TrWric
Control Devices or MUTC 1, All -way stop sign installations are appropriate where each approach
vokure Is approximately equal. The minirntxn trains vaumes required to meet the warrants Por
Installation of an all -way stop are:
1. Minimum of S00 vehides per hour average for 8 hours of the day, AA'D
2. The combkwd vehicle and pedestrian volume on the minor street s at '.east 200 urns
during the sarre 8 hour period, and tre avrYage dMay Is at feast 30 seconds per vehicle
during the peak hcxu, AND
3. If the average speed is 40 MPH or greater, ft- requirements are Mb of 1 and 2, above.
For this project, the peak hour volumes or San Dlego Way are 85 AM and 100 PM In the peak
cilrection. Tre volume on the project driveways are approximately 12 vehides per peak hour.
These vdume levels are shgnlficantly below those reoWred to meet the minfmum wa-raMS. The
vaume differential beaveer the driveway and the volume on San Diego Way is not balanced.
The posted speed Gmlt on San Diego Way is 25 MPH. Therefore, the Installation of an all -way
stop sign Is not warranted.
According to the Traffic Calr.ing Primer', Stop Signs are not traffic cal61ng tools, buA devices to
assign right-of-way at intersections. Compliance is also a concern with implementing
urnverrented stop signs. Stud -es have shown that, the violation rate at unwarranted Ston sign
Insta' at{ons for 3 -way stops (such as these being considered) is as h1gh as 93%.
Recom mend stion
At nin min, the project proposed installation of stop sgns for the traff4c a dting the project
driveways st ou'd be tnsta'led. In our opinion, the all -way stop sign concept should not be
considered as a v.ab'e alternative. It would be our recommendation, that the project as
proposed be constructed and traffic flaws evaluated after six months of occupancy. Should the
City determine that trWfic calming Is neeeed, the shocker/curb bulb outs could be inaaPed.
ShoUd you have any questions, feel free to contact us.
Sincerely,
Q jkpfE88/q
e�OQ�E'A A.0,9��
Stephen A. Orosz, PE, PTOE
Orosz Engineering Group, Inc.
oe �gi �4 si
Attachments
cc. Tim Roberts, Roberts Engineering �l��f ee , AF*% FQQ��
Tra'flc Calming Primer, Pat Noes & Associates, 1998, pages 6 aro 9 (attaMed;
EXHIBIT C: Traffic Calming Study
Resolution PC 2004-0083
TTM 2004-0052
JUL-13-2404 12:46 FM RODEPT6 ENGIHEEPING 236 614e P.AE
}
Q
O
0
W
0
EXHIBIT C: Traffic Calming Study
Resolution PC 2004-0083
TTM 2004-0052
-- •0Q +• h:VbERTS ENGINEERING 2i9 6340
}� N
o,
.OZ 4t I
I 0 r
WV
Q
c^ c ,ZI ,ZI
CL
02
/
�I c
V�
t�
Wu �
EXHIBIT C: Traffic Calming Study
Resolution PC 2004-0083
TTM 2004-0052
Tic Calming Printer
ane Widths for %vhOes
]Yuck rtrrlriainnt one often implemented or, residential streets Where truck traffic is
prohlematic. ]Bose art generally local streets experiencing cut -through tralTic m drven:u::
of truck traffic from the artenal syteen.
PuriFing control can be used as a traffic calming option by restraint the use of
ncighbothood streets as parking lots for adjacent traffic generators such as schools or
hc.sinesses. Tl" restrictions reduce the numbu of cart circulating through the neighbor-
lrtxsd in ccatch of parking.
Geometric Changes
Much of wlut is tttatght of as traffic calming includes physical changes to the rvsdwa%
to reduce navel speeds and'or discourage cut -through traffic from using neighborhood
street.
Ruud+an) narrowing is used to reduce speeds and discourage cut through trafTrc 1+ c,
also he used to improve pedestrian safo:y and provide enhancement opportunnnes.
heckdowns. chokers and curb<xtenuom are constructed a: intersections or mid-bloeL to
natio- the street. Medians can also be used to nsrrtow each sick of the succi. and one-Wic
sections spuria extensive narrowing opportunities.
Urverrer.t are physical devices that divcn tnfric from contertamp through a neighbor-
hood. Diagcmally divertert restrict through and Left turn movements and art he used to
eliminate cut through traffic or draert it out of a specific area Semi-divertrts arc lea
n- i-ictivc than full diverten and are also used to resinct movements into w through a
neighburliood.
Clnsvirs arc used to completely restrict traffic at the Mm of cbm..•. -' !A oft
like claumm restrict traffic and eliminate cut -through traffic,
Trofic circler are useJ to fedi x sr.eeds and discourage cut-thmuRh trofric. They are
pertrrally installed at interaction but can be installed mid -block, right of -way permittirg
C/warnrlr:ed fhrrrd rum• tic similar to semi•divertcrs in their ability to restnet
moiements and eliminate cut -through traffic.
Sliced humps arc probably the most commonly used geometric change vafTc calming
tout They are used to slow traffic and discourage cut through traffic on residential preens
Raised crossings are basically Gsatopped speed humps, or speed tables. kruted at. and
signed for, pedestrian crossings.
Curwd olignmentr include chicarim offsets, and curvilinear streets used to slow the
speed of traffic.
Other Tools
Londicaping is fitted not only to enhance the sodietecs of traffic arming devkrs. bat
also to increase their efrecuveness. Landscaping softens the environment and can be nae_"
bink up the driver's line of sight, reducing the comfortable spend of travel
Public education can be an important element of a comprehensive vafric alm:re
program Public education an include efforts to make the public more aware of their own
driving behavice and die impwu it has on others. Drive•, safety infornat:on and aducaua:
on existing laws an help improve driver behavior.
Strict furniture, like landscaping, can be toed to enhance sitrer:scapc scalietio, aofien
the feel of the tercet and acoentuate the presence of pedesuiuts.
Tools not Recommended for Traffic Calming
Stap signs, though one of the most currtnwoly requested devices by neighborhood
residents, are not considered traffic calming devices. Stop signs arc used to assign right of
way at intersections Although many citimos believe that stop signs help reduce speeds or
their street, studies have shown that btv md•block, spoew arc ac high or higher than those
locations without stop signs. Compliance is also a conccni imptementinK unwarranted
stop signs. Again, stadia have shown a sigtri(kase viastlon rate for unwarranted multi•rs)
tar. A �.�,wrhmeid Aatr.cYSM ir9A
EXHIBIT C: Traffic Calming Study
Resolution PC 2004-0083
TTM 2004-0052
T .07c Conning `omf,
stop signs, with as few as 1% of a vehicles wmins to a complete pop at three-way stol+s
unvarramod stop si=tu delay all motonsu. whether they are traveling the speed limn
or exccoding it This delay perulires all driven rat1w than tarllctir.g violators. Addition-
ally. they an create noise and emissions impacts to the adjacent residem.
Alduugh cornmortly requested. it is often hclpfbl to explore alternative optima with
neighborhood residents, as stop vtgm generally do rot provide the relief they are looking fox
as well u other traffic abnirtt dev ccs do
Child,en m NY "Km are a'v commonly tequested by nrizers concerned with vaftr
safety in their neighborhoWk These signs have not been found to be effective and other
oFuons fa addressing residents' concerns should be pursued
Sposd diju• though M%t commonly recognized as a trafYk calming too!, arc somvnimcs
requemed by citizens who "-t%.c Cie effects of drayage cross pans on ttafllc w-od. The
mrtallation of dips for speed control is generally not effective for most general purpose
vehicles Arid nas been found to ha%r significant negative tm?acts on ernertteccy response
vehicles
Speed AY,npr have a similar effect A% spud dips. These shom round tum;rs in the rout
can be negotisted a high speeds by many, general purpose %chicles, but result in significant
problems for emergency ns, onsc vehicles. They ht%e been found to have a number of safay
and liability limiunon►,
RosrrduDnup arc generaiiy nes conssdentid to be tra"rsc erlming devices. Modem
roundahouts aro installed in intersections in lieu of signats and accommodate high volumes
of traffic. Modon, row+dalcuu art utsetided to increase the capacity of Intersections rather
than calm tnfric
Application of Tools
Each toot has appropriate applications and uses, Each Addresses the various objective
Of traffic calming more or less etfoctively than other. Although the applicator of each
devlce vanes by conditions, the following is a general list of traffic calming devices by
o%MOeti ve.
Reduce Spared
Traffic Circles
• Neckdowns
• Medians
• Chokers
• Enforcement
• Phyto Rader
• Spited Trail@.
• Landscaping
• Speed Humps
Realigned Intersection
niverters
Raised Crosswalks
Raised Intersections
• [kviatton►
Mitigate Cut -Through Traffic
' Urrer:cn
• Closures
• Signed Tum Resincuons
• Physical Turn Restrictions
One-way Sections
Partial Closures
QatawgNentry ways
ITEM NUMBER: 5
DATE: 7/20/04
Atascadero Planning Commission
Staff Report - Community Development Department
Tentative Parcel Map 2004-0058 (AT 03-0101)
2135 San Fernando Rd.
(Phillips)
SUBJECT:
Proposed subdivision of one existing parcel totaling approximately 6.05 acres into two
parcels of 2.93 and 3.06 acres, gross. A single-family residence is currently under
construction on the site.
RECOMMENDATION:
Staff Recommends:
Planning Commission adopt Resolution No. PC 2004-0079, certifying Proposed Mitigated
Negative Declaration 2004-0020 and approving Tentative Parcel Map 2004-0058, based
on findings and subject to conditions of approval and mitigation monitoring.
SITUATION AND FACTS:
1. Applicant/Owners: Daniel and Susan Phillips, 8800 EI Camino Real,
Atascadero, CA 93422 Phone: (805) 461-1664
2. Representative: Wilson Land Surveys, 7600 Morro Road,
Atascadero, California 93422, Phone: (805) 466-
2445
3. Project Address: 2135 San Fernando Rd., Atascadero, CA 93422
APN 049-281-012
4. General Plan Designation: Rural Estates (RE)
5. Zoning District
6. Site Area:
7. Existing Use:
8. Environmental Status
DISCUSSION:
Project Definition
ITEM NUMBER: 5
DATE: 7/20/04
Residential Suburban (RS)
6.05 Acres gross
Single family residence under construction
Proposed Mitigated Negative Declaration 2004-
0020
The proposed project consists of proposed parcel map to subdivide one 6.05 -acre parcel
into two parcels of 2.93 and 3.06 acres gross. The site is currently being developed with a
single-family residence which is located on proposed parcel one. The site is moderately to
steeply sloped with an average slope of 20.9%. A majority of the site contains dense native
tree canopy cover.
Background
pct Parcel: 2135 San Fernando
Rd
Zoning: Residential Suburban
The project site is within the Rural Estates General Plan land use designation and is zoned
Residential Suburban, with a minimum lot size of 2.5 to 10 acres depending on site
characteristics and based on performance standards. Surrounding properties are zoned
Residential Suburban.
Subdivision Design:
ITEM NUMBER: 5
DATE: 7/20/04
The subdivision will divide one existing lot into two parcels. Proposed Parcel 2 is
designed with a 20 -foot wide flag in accordance with Subdivision Ordinance requirements.
Although a flag is required and will be provided, shared access for both Parcel one and
two is proposed by way of an access easement. The subdivision, as proposed, meets
Zoning Ordinance standards related to minimum parcel size. The minimum lot size for both
parcels is 2.926 -acres gross as shown in the following calculation tables:
Minimum Lot Size Criteria For the Residential Suburban Zone
Address
2135 San Fernando Rd
Lot Size Factors
APN
049-281-012
Lot Size
6.05ac
Contact
Phillips
0-8,000=.20, 8-10,000=.25
10-12,000 =.30, 12- 14,000 =
.40, 14-16,000 =.50,16-18,000
Distance from Center
=.60, 18-20,000=.75, >
of Community
20,000 =.90
13,500
0.4
<20 min/inch=.50
20-39 min/inch=.75
Septic Suitability
40-59 min/inch= 1.00
(perk rate)
> 60 min/inch= 1.50
0.75
0-10%=.5, 11-20%=.75,
21-25%= 1.0, 26-30%=1.25,
Average Slope
31- 35%=1.75, 36-40%=2.00
20.40%
0.75
City accepted road =.40
Paved road less than 15% =.40
Paved road more than 15% =.50
All weather less than 15% _ .75
All weather more than 15% _
1.00 Unimproved less than
15% = 1.25 Unimproved more
Access Condition
than 15% = 1.5
0.4
lot sizes within 1,500'
Average Lot Size
Within 1500 Feet
(acres)
3.13
0.63
Minimum Lot
Size=
2.926
Site improvements currently under construction will be confined to proposed Parcel 1.
Percolation tests indicate that the proposed parcel 2 is suitable for an engineered onsite
septic system. Atascadero Mutual Water Company will provide water to the potential new
residence at the time of development. Future utilities to the new lot will be required to be
placed underground and located within the driveway area to reduce any potential impacts
to native vegetation (Condition 11).
Future Improvements, Parcel 2:
ITEM NUMBER: 5
DATE: 7/20/04
The applicant is proposing a building envelope located at the south-east corner of parcel 2.
The proposed area for future construction includes a potential removal of 100 trees totaling
1,471 inches dbh. The proposed driveway location spurs off of the driveway serving parcel
1 and has the potential to impact 10 trees totaling 153 inches dbh exclusive of any potential
impacts due to grading. The project includes the approval of possible tree removals within
the designated building envelope and driveway location. As conditioned, tree removals
within the building envelope and specified driveway location which are associated with
future construction on Parcel 2 will not required Planning Commission review and approval
(Condition 10). Staff has conditioned that future driveway development incorporate
retaining walls into the design to minimize grading impacts to adjacent native trees
(Condition 13).
Approximation of
{,., ►. building envelope
Ji 1—A a —A&A lnratinn
Ii
•
♦
♦
Approximate
location of
residence under
construction
Public Improvements:
The project has been conditioned to apply an asphalt overlay on the San Fernando Road
frontage to the centerline plus 10 feet, prior to recordation of the final map.
General Plan Consistency
ITEM NUMBER:
DATE: 7/20/04
The subdivision is consistent with the General Plan Rural Estate land use designation and
Residential Suburban zoning regulations with minimum lot sizes of 2.93 and 3.06 acres
gross, based on performance standards.
ITEM NUMBER: 5
DATE: 7/20/04
Findings
1. The proposed subdivision, as conditioned, is consistent with the General Plan and
applicable zoning requirements.
2. The design and improvement, as conditioned, of the proposed subdivision is
consistent with the General Plan and applicable zoning requirements.
3. The site is physically suitable for the density of development proposed.
4. The design and improvement of the proposed subdivision will not cause substantial
environmental damage or substantially and unavoidably injure fish and wildlife or
their habitat.
5. The subdivision is consistent with the character of the immediate neighborhood.
6. The design of the subdivision will not conflict with easements acquired by the public
at large for access through, or the use of property within, the proposed subdivision;
or substantially equivalent alternative easements are provided.
7. The proposed subdivision design and type of improvements proposed will not
cause serious public health problems.
8. The proposed subdivision will be accomplished without detriment to the adjacent
properties.
9. The installation of a standard street, either alone or in conjunction with neighboring
properties is not feasible.
Proposed Environmental Determination
Staff has prepared a Draft Mitigated Negative Declaration, circulated to public agencies
and interested members of the public on June 7, 2004. The environmental analysis
identified concerns regarding potential impacts to aesthetics, air quality, biological
resources, geology & soils, and noise. Mitigation measures pertaining to these resources
are included. A finding is proposed that this project would not have a significant effect on
the environment based upon the implementation of the identified mitigation measures.
Staff is recommending the Commission recommend that the City Council certify Proposed
Mitigated Negative Declaration 2004-0020.
Conclusion
The subdivision, as conditioned, is consistent with the 2002 General Plan and Zoning
Ordinance. The parcel configurations are consistent with the Subdivision Ordinance
requirements and the size and shape of the proposed lots are consistent with the character
of the immediate neighborhood. Staff recommends the Planning Commission approve
Tentative Parcel Map 2004-0058 as conditioned.
ITEM NUMBER: 5
DATE: 7/20/04
ALTERNATIVES:
1. The Commission may approve the subdivision subject to additional or revised project
conditions.
2. The Commission may deny the subdivision if it is found to be inconsistent with the
General Plan or any of the other required findings. The Commission's motion to deny
must include a finding basis for denial.
3. The Commission may continue the hearing and refer the item back to staff for
additional information or analysis. Direction should be given to staff and the applicant
on required information.
PREPARED BY: Kelly Gleason, Associate Planner
ATTACHMENTS:
Attachment 1 -- Location Map
Attachment 2 -- Proposed Mitigated Negative Declaration 2004-0020 and
Initial Study
Attachment 3 -- Draft Resolution PC 2004-0079
ITEM NUMBER: 5
DATE: 7/20/04
ATTACHMENT 1: Location Map (General Plan / Zoning)
TPM 2004-0058
2135 San Fernando Rd.
i •tiY1
Subject Parcel: 2135 San Fernando Rd
Zoning: Residential Suburban d
Plan Rural Pcfaf c
ITEM NUMBER:
DATE: 7/20/04
ATTACHMENT 2: Proposed Mitigated Negative Declaration and Initial Study
TPM 2004-0058
2135 San Fernando Rd.
This page intentionally left blank.
ITEM NUMBER: 5
DATE: 7/20/04
ATTACHMENT 3: Draft Resolution No. PC 2004-0079
TPM 2004-0058
2135 San Fernando Rd.
DRAFT RESOLUTION NO. PC 2004-0079
A RESOLUTION OF THE PLANNING COMMISSION
OF THE CITY OF ATASCADERO CERTIFYING PROPOSED
MITIGATED NEGATIVE DECLARATION 2004-0020 AND
APPROVING A TENTATIVE PARCEL MAP 2004-0058
TO DIVIDE ONE RESIDENTIAL LOT INTO TWO
RESIDENTIAL LOTS ON APN 049-281-012
(Phillips)
WHEREAS, an application has been received from Dan and Susan Phillips (8800 El Camino
Real, Atascadero, CA 93422) Applicant and Property Owner to consider a project consisting of a two
lot residential Tentative Parcel Map; and,
WHEREAS, the proposed project has a General Plan Designation of Rural Estates (RE) and is
in conformance with the Land Use Element of the General Plan and all other applicable General Plan
policies; and,
WHEREAS, the site is located in the Residential Suburban (RS), with a minimum lot size of 2.5
to 10 acres based on specific performance standards, which allows for the proposed use and density
when certain findings are made; and,
WHEREAS, the laws and regulations relating to the preparation and public notice of
environmental documents, as set forth in the State and local guidelines for implementation of the
California Environmental Quality Act (CEQA) have been adhered to; and,
WHEREAS, an Initial Study and Draft Mitigated Negative Declaration 2004-0020 were
prepared for the project and made available for public review in accordance with the requirements of
the California Environmental Quality Act (CEQA); and,
V4WREAS, the Planning Commission of the City of Atascadero, at a duly noticed Public
Hearing held on July 20, 2004, studied and considered Tentative Parcel Map 2004-0058, after first
studying and considering the Proposed Mitigated Negative Declaration prepared for the project; and,
ITEM NUMBER:
DATE: 7/20/04
NOW, THEREFORE, the Planning Commission takes the following actions:
SECTION 1. Certification of Negative Declaration. The Planning Commission of the City
of Atascadero, hereby certifies Mitigated Negative Declaration 2004-0020 based on the following
findings:
1. The Negative Declaration has been completed in compliance with requirements of the
California Environmental Quality Act; and,
2. The project does not have the potential to degrade the environment; and
3. The project will not achieve short-term to the disadvantage of long-term environmental
goals; and,
4. The project does not have impacts which are individually limited, but cumulatively
considerable; and,
5. The project will not cause substantial adverse effects on human beings either directly or
indirectly.
SECTION 2. Approval of Tree Removal Permit, the Planning Commission of the City of
Atascadero finds as follows:
The tree is obstructing proposed improvements that cannot be reasonably designed to avoid
the need for tree removal, as certified by a report from the Site Planner and determined by the
Community Development Department based on the following factors:
1. Early consultation with the City;
2. Consideration of practical design alternatives;
3. Provision of cost comparisons (from applicant) for practical design
alternatives;
4. If saving tree eliminates all reasonable uses of the property; or
5. If saving the tree requires the removal of more desirable trees.
SECTION 3. Findings of Approval for Tentative Parcel Map, the Planning Commission of
the City of Atascadero finds as follows:
1. The proposed subdivision, as conditioned, is consistent with the General Plan and
applicable zoning requirements.
2. The design and improvement, as conditioned, of the proposed subdivision is consistent
with the General Plan and applicable zoning requirements.
3. The site is physically suitable for the density of development proposed.
4. The design and improvement of the proposed subdivision will not cause substantial
environmental damage or substantially and unavoidably injure fish and wildlife or their
habitat.
5. The subdivision is consistent with the character of the immediate neighborhood.
ITEM NUMBER: 5
DATE: 7/20/04
6. The design of the subdivision will not conflict with easements acquired by the public at
large for access through, or the use of property within, the proposed subdivision; or
substantially equivalent alternative easements are provided.
7. The proposed subdivision design and type of improvements proposed will not cause
serious public health problems.
8. The proposed subdivision will be accomplished without detriment to the adjacent
properties.
9. The installation of a standard street, either alone or in conjunction with neighboring
properties is not feasible.
SECTION 4. Approval. The Planning Commission does hereby approve Tentative Parcel
Map 2004-0058 (AT 03-0101) to subdivide one parcel totaling 6.05 acres into two parcels of 2.93
and 3.06 acres, subject to the following Conditions and Exhibits:
EXHIBIT A:
Proposed Mitigated Negative Declaration 2004-0020
EXHIBIT B:
Conditions of Approval
EXHIBIT C:
Tentative Parcel Map 2004-0058 (AT 03-0101)
EXHIBIT D:
Potential Tree Removal List
On motion by Commissioner and seconded by Commissioner
the foregoing resolution is hereby adopted in its entirety by the following roll call
vote:
AYES:
NOES:
ABSENT:
ABSTAINED:
ADOPTED:
CITY OF ATASCADERO, CA
Bob Kelley
Planning Commission Chairperson
ATTEST:
ITEM NUMBER:
DATE: 7/20/04
Warren Frace
Planning Commission Secretary
ITEM NUMBER:
DATE: 7/20/04
EXHIBIT A: Proposed Mitigated Negative Declaration
Draft Resolution PC 2004-0079
TPM 2004-0058
This page intentionally left blank
ITEM NUMBER:
DATE: 7/20/04
EXHIBIT B: Conditions of Approval
Draft Resolution PC 2004-0079
TPM 2004-0058
Conditions of Approval / Mitigation Monitoring Program
Timing
Responsibility
Mitigation
/Monitoring
Measure
TPM 2004-0058 (AT 03-0101)
PM: Parcel Map
GP: Grading Prmt
PS: Planning Services
BP: Building Pnmt
BS: Building Services
2135 San Fernando Rd
TO: Temporary
FD: Fire Department
Occupancy
PD: Police Department
F0: Final Occupancy
CE: City Engineer
PI: Public Improvements
WW: Wastewater
CA: City Attorney
AMWC: Atascadero
Mutual Water Company
Planning Services - Standard Planning Conditions
7
1. The approval of this application shall become final, subject to
PM
PS
the completion of the conditions of approval, fourteen (14)
days following the Planning Commission approval unless
prior to that time, an appeal to the decision is filed as set forth
in Section 9-1.111(b) of the Zoning Ordinance.
2. Approval of this Tentative Parcel Map shall be valid for two
PM
PS
years after its effective date. At the end of the period, the
approval shall expire and become null and void unless an
extension of time is granted pursuant to a written request
received prior to the expiration date.
3. The Community Development Department shall have the
PM
PS
authority to approve minor changes to the project that (1) result
in a superior site design or appearance, and/or (2) address a
construction design issue that is not substantive to the
Tentative Parcel Map.
4. A parcel map drawn in substantial conformance with the
PM
PS
approved tentative map, and in compliance with all conditions
set forth herein, shall be submitted for review and approval in
accordance with the Subdivision Map Act and the City's
Subdivision Ordinance.
5. The subdivider shall defend, indemnify, and hold harmless the
Ongoing
CA
City of Atascadero or its agents, officers, and employees
against any claim or action brought to challenge an approval
by the City, or any of its entities, concerning the subdivision.
6. The parcel map shall be subject to additional fees for park or
PM
PS
recreation purposes (QUIMBY Act) as required by City
Ordinance.
Project Specific Conditions
7. The final map shall clearly identify the building envelope. No
PM
PS
construction of structures of septic facilities may be located
ITEM NUMBER:
DATE: 7/20/04
Conditions of Approval / Mitigation Monitoring Program
Timing
Responsibility
Mitigation
/Monitoring
Measure
TPM 2004-0058 (AT 03-0101)
PM: Parcel Map
GP: Grading Prmt
PS: Planning Services
BP: Building Prmt
BS: Building Services
2135 San Fernando Rd
TO: Temporary
FD: Fire Department
Occupancy
PD: Police Department
F0: Final Occupancy
CE: City Engineer
PI: Public Improvements
WW: Wastewater
CA: City Attorney
AMWC: Atascadero
Mutual Water Company
outside of the approved building envelope. All provisions shall
be reviewed by the Community Development Director and the
City Attorney for approval, prior to recordation.
8. The final map shall clearly identify the driveway location
BP
PS
consistent with EXHIBIT C. Any proposed changes to the
driveway that result in impacts to additional native trees shall
be reviewed in conformance with the Atascadero Native Tree
Ordinance, subject to staff approval.
9. All future construction on Parcel 2 shall adhere to the hillside
BP
PS/BS
grading policies as follows:
A Cut and fill pads shall be allowed provided the following
requirements can be met:
■ Natural slopes are under 30%.
■ Native tree impacts are minimal.
■ The cut pad is reasonable related to the size of the
house footprint.
■ Newly graded flat yard areas are minimized.
■ Landscape and irrigation plans prepared by a
licensed professional are provided for all resulting cut
and fill slopes. Landscape plans should incorporate
native drought tolerant trees, shrubs and g round
covers (refer to City plant list).
■ Erosion control plans must be provided.
B. The following guidelines apply to grading in proximity to
native trees:
■ Stem wall house construction should be considered
to save native trees.
■ Retaining walls should be incorporated into cut and
fill slopes to avoid/minimize impacts to native trees.
■ Tree preservation mitigations measures must be
developed by an arborist for all impacted trees.
10. Future construction shall adhere to the requirements of the
BP
PS
Atascadero Native Tree Ordinance in regards to protection
measures and removal mitigation. This project includes a
request for tree removal based on the proposed building
envelope with a maximum of 1625 inches dbh. Planning
Commission review and approval for removal within the
building envelope shall not be required.
ITEM NUMBER:
DATE: 7/20/04
Conditions of Approval / Mitigation Monitoring Program
Timing
Responsibility
Mitigation
/Monitoring
Measure
TPM 2004-0058 (AT 03-0101)
PM: Parcel Map
GP: Grading Prmt
PS: Planning Services
BP: Building Prmt
BS: Building Services
2135 San Fernando Rd
TO: Temporary
FD: Fire Department
Occupancy
PD: Police Department
F0: Final Occupancy
CE: City Engineer
PI: Public Improvements
WW: Wastewater
CA: City Attorney
AMWC: Atascadero
Mutual Water Company
11. All utilities shall be placed underground in the area of the
BP
PS
driveway in order to reduce trenching and potential impacts to
native vegetation.
12. In accordance with the City's Subdivision Ordinance, the flag
PM
PS/CE
portion of Lot 2 shall be a minimum 20 feet in width.
13. The driveway shall incorporate retaining walls to
BP
PS
avoid/minimize impacts to adjacent native trees.
14. A reflectorized house number master sign shall be located at
PM
PS/CE
the intersection of the street and accessway and individual
reflectorized address signs shall be placed on the right-hand
side of the driveway to each individual lot.
Fire Marshal Standard Conditions
15. Residential fire sprinkler system required.
BP
FD
16. A dry standpipe installed to city standard is required.
BP
FD
City Engineer Project Conditions
17. San Fernando Road shall be overlaid to the centerline plus 10
FM
PW
feet along the entire property frontage.
18. Improvements shall not obstruct existing drainage patterns.
FM
PW
City Engineer Standard Conditions
19. All public improvements shall be constructed in conformance
BP
PW
with the City of Atascadero Engineering Department Standard
Specifications and Drawings and/or as directed by the City
Engineer.
20. In the event that the applicant is allowed to bond for the public
FM
PW
improvements required as a condition of this map, the
applicant shall enter into a Subdivision Improvement
Agreement with the City Council.
21. An engineer's estimate of probable cost shall be submitted for
FM
PW
review and approval by the City Engineer to determine the
amount of the bond.
ITEM NUMBER:
DATE: 7/20/04
Conditions of Approval / Mitigation Monitoring Program
Timing
Responsibility
Mitigation
/Monitoring
Measure
TPM 2004-0058 (AT 03-0101)
PM: Parcel Map
GP: Grading Prmt
PS: Planning Services
BP: Building Prmt
BS: Building Services
2135 San Fernando Rd
TO: Temporary
FD: Fire Department
Occupancy
PD: Police Department
F0: Final Occupancy
CE: City Engineer
PI: Public Improvements
WW: Wastewater
CA: City Attorney
AMWC: Atascadero
Mutual Water Company
22. The Subdivision Improvement Agreement shall record
FM
PW
concurrently with the Final Map.
23. An encroachment permit shall be obtained prior to the
BP
PW
issuance of building permit.
24. The applicant shall be responsible for the relocation and/or
BP
PW
alteration of existing utilities.
25. The applicant shall install all new utilities (water, gas, electric,
BP
PW
cable TV and telephone) underground. Utilities shall be
extended to the property line frontage of each lot or its public
utility easement.
26. The applicant shall monument all property corners for
FM
PW
construction control and shall promptly replace them if
disturbed.
27. The applicant shall acquire title interest in any off-site land that
FM
PW
may be required to allow for the construction of the
improvements. The applicant shall bear all costs associated
with the necessary acquisitions. The applicant shall also gain
concurrence from all adjacent property owners whose ingress
and egress is affected by these improvements.
28. Slope easements shall be provided as needed to
FM
PW
accommodate cut of fill slopes.
29. Drainage easements shall be provided as needed to
FM
PW
accommodate both public and private drainage facilities.
30. A preliminary subdivision guarantee shall be submitted for
FM
PW
review in conjunction with the processing of the parcel map.
31. All existing and proposed utility, pipeline, open space, or other
FM
PW
easements are to be shown on the parcel map. If there are
building or other restrictions related to the easements, they
shall be noted on the parcel map. The applicant shall show
all access restrictions on the parcel map.
32. The final map shall be signed by the City Engineer prior to the
FM
PW
map being placed on the agenda for City Council acceptance.
ITEM NUMBER:
DATE: 7/20/04
Conditions of Approval / Mitigation Monitoring Program
Timing
Responsibility
Mitigation
/Monitoring
Measure
TPM 2004-0058 (AT 03-0101)
PM: Parcel Map
GP: Grading Prmt
PS: Planning Services
BP: Building Prmt
BS: Building Services
2135 San Fernando Rd
TO: Temporary
FD: Fire Department
Occupancy
PD: Police Department
F0: Final Occupancy
CE: City Engineer
PI: Public Improvements
WW: Wastewater
CA: City Attorney
AMWC: Atascadero
Mutual Water Company
33. Prior to recording the parcel map, the applicant shall submit a
FM
PW
map drawn in substantial conformance with the approved
tentative map and in compliance with all conditions set forth
herein. The map shall be submitted for review and approval by
the City in accordance with the Subdivision Map Act and the
City's Subdivision Ordinance.
34. Prior to recording the parcel map, the applicant shall set
FM
PW
monuments at all new property corners. A registered civil
engineer or licensed land surveyor shall indicate by certificate
on the parcel map, that corners have been set or shall be set
by a date specific and that they will be sufficient to enable the
survey to be retraced.
35. Prior to recording the parcel map, the applicant shall pay all
FM
PW
outstanding plan check/inspection fees.
36. Prior to recording the map, the applicant shall complete all
FM
PW
improvements required by these conditions of approval.
37. Prior to recording the parcel map, the applicant shall have the
FM
PW
map reviewed by all applicable public and private utility
companies (cable, telephone, gas, electric, Atascadero Mutual
Water Company). The applicant shall obtain a letter from each
utility company indicating their review of the map. The letter
shall identify any new easements that may be required by the
utility company. A copy of the letter shall be submitted to the
City. New easements shall be shown on the parcel map.
38. Upon recording the final map, the applicant shall provide the
FM
PW
City with a black line clear Mylar (0.4 mil) copy and a blue line
print of the recorded map.
39. Prior to the final inspection of any public improvements, the
FM
PW
applicant shall submit a written statement from a registered
civil engineer that all work has been completed and is in full
compliance with the approved plans.
40. Prior to the final inspection, the applicant shall submit a written
FM
PW
certification from a registered civil engineer or land surveyor
that all survey monuments have been set as shown on the
final map.
Atascadero Mutual Water Company:
ITEM NUMBER:
DATE: 7/20/04
Conditions of Approval / Mitigation Monitoring Program
Timing
Responsibility
Mitigation
/Monitoring
Measure
TPM 2004-0058 (AT 03-0101)
PM: Parcel Map
GP: Grading Prmt
PS: Planning Services
BP: Building Prmt
BS: Building Services
2135 San Fernando Rd
TO: Temporary
FD: Fire Department
Occupancy
PD: Police Department
F0: Final Occupancy
CE: City Engineer
PI: Public Improvements
WW: Wastewater
CA: City Attorney
AMWC: Atascadero
Mutual Water Company
Prior to recordation of the Final Map, the applicant shall submit plans
PM
AMWC
showing the water distribution facilities required to serve the project for
review and approval by the Atascadero Mutual Water Company. All new
water distribution facilities shall be constructed in conformance with
Atascadero Mutual Water Company standards.
Prior to the recordation of the Final Map, the applicant shall obtain a
PM
AMWC
"Will Serve" letter from the Atascadero Mutual Water Company.
Prior to the issuance of building permits, the applicant shall pay all
BP/GP
AMWC
installation and connection fees required by the Atascadero Mutual
Water Company.
All water distribution facilities shall be constructed in conformance with
PM
AMWC
Atascadero Mutual Water Company standards, policies and approved
procedures. All cross -connection devices shall be constructed in
conformance with AWWA and Department of Health Services
standards.
Each newly created parcel will require separate water meters.
PM
AMWC
Mitigation Measures
Mitigation Measure 1.c.1: A landscape plan prepared by a qualified
BP
PS/BS
1.c.1
professional shall be submitted with future building permits should the
home site design include any cut and fill slopes. All cut and fill slopes
will be revegetated with native grasses, shrubs, and trees consistent
with the surrounding vegetation.
Mitigation Measure 1.c.2: Any retaining walls shall be constructed of
BP
PS/BS
1.c.2
dark color split face block or better and shall be designed to blend in
with the existing terrain.
Mitigation Measure 3.b.1 : The project shall be conditioned to comply
BP
PS/BS
3.b.1
with all applicable District regulations pertaining to the control of fugitive
dust (PM -10) as contained in section 6.4 of the Air Quality Handbook. All
site grading and demolition plans notes shall list the following
regulations:
Section 6.3: Construction Equipment
■ Maintain all construction equipment in proper tune according
to manufacturer's specifications.
■ Fuel all off-road and portable diesel powered equipment,
including but not limited to bulldozers, graders, cranes,
ITEM NUMBER:
DATE: 7/20/04
Conditions of Approval / Mitigation Monitoring Program
TPM 2004-0058 (AT 03-0101)
2135 San Fernando Rd
Timing
PM: Parcel Map
GP: Grading Prmt
BP: Building Prmt
TO: Temporary
Occupancy
F0: Final Occupancy
PI: Public Improvements
Responsibility
/Monitoring
PS: Planning Services
BS: Building Services
FD: Fire Department
PD: Police Department
CE: City Engineer
WW: Wastewater
CA: City Attorney
AMWC: Atascadero
Mutual Water Company
Mitigation
Measure
loaders, scrapers, backhoes, generator sets, compressors,
auxiliary power units, with ARB certified motor vehicle diesel
fuel (Non -taxed version suitable for use off-road).
• Maximize to the extent feasible, the use of diesel construction
equipment meeting the ARB's 1996 or newer certification
standard for off-road heavy-duty diesel engines.
■ Install diesel oxidation catalysts (DOC), catalyzed diesels
particulate filters (CDPF) or other District approved emission
reduction retrofit services (Required for projects grading more
than 4.0 acres of continuously worked area).
Section 6.4: Activity Management Techniques
■ Develop a comprehensive construction activity management
plan designed to minimize the amount of large construction
equipment operating during any given time period.
■ Schedule of construction truck trips during non -peak hours to
reduce peak hour emissions.
■ Limit the length of the construction workday period, if
necessary.
■ Phase construction activities, if appropriate.
Section 6.5: Fugitive PM10
All of the following measures shall be included on grading, demolition
and building plan notes:
A Reduce the amount of the disturbed area where possible.
B. Use of water trucks or sprinkler systems in sufficient quantities to
prevent airborne dust from leaving the site. Increased watering
frequency would be required whenever wind speeds exceed 15
mph. Reclaimed (non -potable) water should be used whenever
possible.
C. All dirt stockpile areas should be sprayed daily as needed.
D. Permanent dust control measures identified in the approved
project re -vegetation and landscape plans should be implemented
as soon as possible following completion of any soil disturbing
activities.
E. Exposed ground areas that are planned to be reworked at dates
greater than one month after initial grading should be sown with a
fast -germinating native grass seed and watered until vegetation is
established.
F. All disturbed soil areas not subject to re -vegetation should be
stabilized using approved chemical soil binder, jute netting, or
other methods approved in advance by the APCD.
G. All roadways, driveways, sidewalks, etc, to be paved should be
complete as soon as possible. In addition, building pads should
be laid as soon as possible after grading unless seeding or soil
ITEM NUMBER:
DATE: 7/20/04
Conditions of Approval / Mitigation Monitoring Program
Timing
Responsibility
Mitigation
/Monitoring
Measure
TPM 2004-0058 (AT 03-0101)
PM: Parcel Map
GP: Grading Prmt
PS: Planning Services
BP: Building Prmt
BS: Building Services
2135 San Fernando Rd
TO: Temporary
FD: Fire Department
Occupancy
PD: Police Department
F0: Final Occupancy
CE: City Engineer
PI: Public Improvements
WW: Wastewater
CA: City Attorney
AMWC: Atascadero
Mutual Water Company
binders are used.
H. Vehicle speed for all construction vehicles shall not exceed 15
mph on any unpaved surface at the construction site.
I. All trucks hauling dirt, sand, soil, or other loose materials are to be
covered or should maintain at least two feet of freeboard
(minimum vertical distance between top of load and top of trailer)
in accordance with CVC Section 23114.
J. Install wheel washers where vehicles enter and exit unpaved
roads onto streets, or was off trucks and equipment leaving the
site.
K. Sweep streets at the end of each day if visible soil material is
carried onto adjacent paved roads. Water sweepers with
reclaimed water should be used where feasible.
L. The contractor or builder shall designate a person or persons to
monitor the dust control program and to order increased watering,
as necessary, to prevent transport of dust off site. The name and
telephone number of such persons shall be provided to the APCD
prior to land use clearance for map recordation and land use
clearance for finish grading of any structure.
Mitigation Measure 4.e.1 : The building permit site plan shall identify all
BP
BS/PS
4.e.1
protection and enhancement measures recommended by a Certified
Arborist in a Tree Protection Plan. Tree protection fencing shall be
installed at the driplines of all native trees potentially effected by
construction activities. Should construction activities encroach into the
dripline of any native tree, monitoring by the project arborist shall be
required.
Mitigation Measure 4.e.2: Grading and excavation shall be consistent
BP
BS/PS
4.e.2
with the City of Atascadero Tree Ordinance. Special precautions when
working around native trees include:
1. All existing trees outside of the limits of work shall remain.
2. Earthwork shall not exceed the limits of the project area.
3. Low branches in danger of being torn from trees shall be
pruned prior to any heavy equipment work being done.
4. Vehicles and stockpiled material shall be stored outside the
drip line of all trees.
5. All trees within the area of work shall be fenced for protection
with 4 -foot chain link, snow or safety fencing placed per the
approved tree protection plan. Tree protection fencing shall be
in place prior to any site excavation or grading. Fencing shall
remain in place until completion of all construction activities.
6. Any roots that are encountered during excavation shall be
clean cut by hand and sealed with an approved tree seal.
ITEM NUMBER:
DATE: 7/20/04
Conditions of Approval / Mitigation Monitoring Program
TPM 2004-0058 (AT 03-0101)
2135 San Fernando Rd
Timing
PM: Parcel Map
GP: Grading Prmt
BP: Building Prmt
TO: Temporary
Occupancy
F0: Final Occupancy
PI: Public Improvements
Responsibility
/Monitoring
PS: Planning Services
BS: Building Services
FD: Fire Department
PD: Police Department
CE: City Engineer
WW: Wastewater
CA: City Attorney
AMWC: Atascadero
Mutual Water Company
Mitigation
Measure
Mitigation Measure 4.e.3: The developer shall contract with a certified
BP
BS/PS
4.e.3
arborist during all phases of project implementation. The certified
arborists shall be responsible for monitoring the project during all
phases of construction through project completion, as follows:
(a) A written agreement between the arborist and the developer
outlining an arborist monitoring schedule for each construction
phase through final inspection shall be submitted to and approved
by planning staff prior to the issuance of building/grading permits.
(b) Arborist shall schedule a pre -construction meeting with
engineering /planning staff, grading equipment operators, project
superintendent to review the project conditions and requirements
prior to any grubbing or earth work for any portion of the project site.
All tree protection fencing and trunk protection shall be installed for
inspection during the meeting.
(c) As specified by the City staff:
■ Fencing: Must be a minimum of 4' high chain link, snow or
safety fence staked at the drip -line or line of encroachment for
each group of trees. The fence must be up before any
construction or earth moving begins. The arborist(s) shall
inspect the fence placement once it is erected.
■ Soil Aeration Methods: Soils under the drip -lines that have
been compacted by heavy equipment and/or construction
activities must be returned to their original state before all work
is completed. Methods include water jetting, adding organic
matter, and boring small holes with an auger (18" deep, 2-3'
apart with a 2-4" auger) and the application of moderate
amounts of nitrogen fertilizer. The arborist(s) shall advise.
■ Chip Mulch: All areas within the drip line of the trees that
cannot be fenced shall receive a 4-6" layer of chip mulch to
retain moisture, soil structure and reduce the effects of soil
compaction.
■ Trenching Within the Drip Line: All trenching under the drip
lines of native trees shall be hand dug, augured or bored. All
major roots shall be avoided whenever possible. All exposed
roots larger than 1" in diameter shall be clean cut with a sharp
pruning tool and not left ragged. Trenching will occur during
septic line construction and water line construction.
■ Grading Within the Drip Line: Grading should not encroach
within the drip line. If grading is necessary, construction of
retaining walls or tree wells or other protection measures may
be necessary to insure the survivability of the trees. Chip
mulch 4-6" in depth may also be required in these areas.
Grading should not disturb the normal drainage pattern
ITEM NUMBER:
DATE: 7/20/04
Conditions of Approval / Mitigation Monitoring Program
TPM 2004-0058 (AT 03-0101)
2135 San Fernando Rd
Timing
PM: Parcel Map
GP: Grading Prmt
BP: Building Prmt
TO: Temporary
Occupancy
F0: Final Occupancy
PI: Public Improvements
Responsibility
/Monitoring
PS: Planning Services
BS: Building Services
FD: Fire Department
PD: Police Department
CE: City Engineer
WW: Wastewater
CA: City Attorney
AMWC: Atascadero
Mutual Water Company
Mitigation
Measure
around the trees. Fills should not create a ponding condition
and excavations should not leave the tree on a rapidly draining
mound.
■ Exposed Roots: Any exposed roots shall be recovered the
same day they were exposed.
■ Paving within the Drip Line: Pervious surfacing is preferred
within the drip line of any oak tree.
■ Equipment Operation: Vehicles and all heavy equipment shall
not be driven under the trees, as this will contribute to soil
compaction.
■ Existing Surfaces: The existing ground surface within the drip -
line of all oak trees shall not be cut, filled, compacted, or
pared.
■ Construction Materials and Waste: No liquid or solid
construction waste shall be dumped on the ground within the
drip -line of any oak tree.
■ Arborist Monitoring: An arborist shall be present for road and
house grading, septic line/water trenching, and pre -
construction fence placement. The monitoring does not
necessarily have to be continuous but observational at times
during the above activities.
■ Pre -Construction Meeting: An on-site pre -construction
meeting with the Arborist(s), Owner, Planning Staff, and the
earthy moving team shall be required for this project. Prior to
final occupancy, a letter from the arborist(s) shall be required
verifying the health/condition of all impacted trees and
providing any recommendations for any additional mitigation.
The letter shall verify that the arborist(s) were on site for all
grading and/or trenching activity that encroached into the drip
line of the native trees, and that all work done in these areas
was completed to the standards set forth above.
(d) Upon project completion and prior to final occupancy a final status
report shall be prepared by the project arborist certifying that the
tree protection plan was implemented, the trees designated for
protection were protected during construction, and the
construction -related tree protection measures are no longer
required for tree protection.
Mitigation Measure 4.e.4: All future development shall be located within
GP/BP
BS/PS
4.e.4
the approved building envelope as shown on the approved Tentative
Map. A separate sheet shall be recorded with the final map delineating
the extent of the buildable area. Any development proposed outside of
the approved building envelope will require a Precise Plan application
be submitted prior to the issuance of any building permit.
ITEM NUMBER:
DATE: 7/20/04
Conditions of Approval / Mitigation Monitoring Program
Timing
Responsibility
Mitigation
/Monitoring
Measure
TPM 2004-0058 (AT 03-0101)
PM: Parcel Map
GP: Grading Prmt
PS: Planning Services
BP: Building Prmt
BS: Building Services
2135 San Fernando Rd
TO: Temporary
FD: Fire Department
Occupancy
PD: Police Department
F0: Final Occupancy
CE: City Engineer
PI: Public Improvements
WW: Wastewater
CA: City Attorney
AMWC: Atascadero
Mutual Water Company
Mitigation Measure 4.e.5: All native tree removals associated with
GP/BP
BS/PS
4.e.5
construction on proposed parcel 2 shall be mitigated for in accordance
with the Atascadero native Tree Ordinance. Future construction
proposals shall include design measures which minimize disturbance
of the existing topography and avoid impacts to native trees.
Mitigation Measure 6.b.1 : All disturbed areas shall be hydroseeded
GP/BP
BS/PS
6.b.1
with a native seed mix. Erosion control measures shall include an
erosion control blanket for all 2:1 fill slopes. Affected areas that
previously contained native shrubs and vegetation shall be replanted
with similar plant species per an approved landscape plan. Duration of
the project: The contractor will be responsible for the clean-up of any
mud or debris that is tracked out on to San Fernando Road and/or the
private access drive by construction vehicles.
Mitigation Measure 6.c.d.1 : A soils report shall be required to be
GP/BP
BS/PS
6.c.d.1
submitted with a future building permit. The building plans will be
required to follow the recommendations of the soils report to assure
safety for residents and buildings. The property contains no unusual
geological formations.
Mitigation Measure 6.e.1 : Percolation tests shall be required with the
GP/BP
BS/PS
6.e.1
submittal of any building permits for construction of a residence on
Parcel 2. The proposed waste disposal system shall be reviewed and
approved by the City engineer prior to the issuance of any building
permit.
Mitigation Measure 7.g.h.1 : Consistent with Fire Department standards,
GP/BP
BS/PS
7.g.h.1
any access way to a future residence on proposed Parcel 2 shall be no
greater than 20% in slope at any point along the driveway.
Mitigation Measure 11.d.1: All construction activities shall comply with
GP/BP
BS/PS/FD
11.d.1
the City of Atascadero Noise Ordinance for hours of operation.
Mitigation Measure 15.d.1: Parcel 1 and 2 shall share access off of San
GP/BP
BS/PS/FD
15.d.1
Fernando Rd. All appropriate easements shall be recorded on the final
map.
ITEM NUMBER: 5
DATE: 7/20/04
EXHIBIT C: Tentative Parcel Map (AT 03-0101)
Draft Resolution PC 2004-0079
TPM 2004-0058
ITEM NUMBER:
DATE: 7/20/04
EXHIBIT D: Potential Tree Removal List
Draft Resolution PC 2004-0079
TPM 2004-0058
Wilson Land Surveys
7.1,00 Wm) Roal. Awwidrru. CA Y:4'.2
Ptwxnc: (805) 466-2445 • Fax: (805) 466.0812 • Emad jamesma�ilsonl�nisurnys..rom
PARCEL IAP AT 03-(1101 BUILDING ENVELOPE TREE LIST
POINT v
DIA 'INCHES
DESC
PRONGS
S453
12
WO
3
5454
33
LO
4
5455
20
LO
2
5456
28
LO
3
5457
20
LO
2
5908
8
LO
5909
10
LO
5910
34
LO
7
5912
14
LO
3
5913
24
LO
i
$914
7
LO
5915
5
I.O
5916
12
LO
5917
18
LO
5944
15
LO
5945
15
'NO
5947
24
WO
3
5949
6
LO
5950
8
LO
5951
12
LO
2
5952
8
LO
5953
8
LO
5954
24
LO
DEAD
5955
16
LO
3
5956
18
LO
4
5958
18
LO
2
5998
28
LO
7
6003
14
LO
6005
12
LO
6006
18
LO
6007
10
LO
6008
12
LO
6012
4
LO
6013
9
LO
6014
28
LO
6016
10
LO
6011
7
LO
6020
24
LO
2
6021
7
LO
6023
20
LO
6024
10
LO
2
6025
12
LO
6026
10
LO
L
6027
15
LO
ITEM NUMBER:
DATE: 7/20/04
EXHIBIT D: Potential Tree Removal List
Draft Resolution PC 2004-0079
TPM 2004-0058
6028
7
LO
6029
24
LO
6032
28
LO
6
6033
20
LO
6034
24
LO
6035
10
LO
6036
12
LO
6037
16
LO
2
6039
26
LO
6040
13
LO
2
6041
12
LO
6044
39
LO
6046
13
LO
6047
12
LO
6048
9
LO
6049
5
LO
6050
12
LO
2
6051
14
LO
6088
38
L O
5
6089
13
LO
6090
7
LO
6091
6
LO
6093
8
LO
6094
8
LO
6095
24
LO
4
6096
13
LO
2
609/
16
LO
3
6098
12
LO
2
6099
8
LO
6100
13
LO
3
6101
16
LO
3
6102
24
LO
5
6103
9
LO
6104
8
LO
6105
7
LO
6106
6
LO
6101
7
LO
6108
14
LO
3
6109
13
1.0
2
6110
6
LO
6111
9
LO
6112
24
LO
2
6113
8
LO
6114
17
LO
2
6115
22
LO
2
6116
12
LO
2
6123
10
LO
6124
15
LO
6125
17
LO
6127
14
LO
2
6128
9
LO
6129
5
LO
ITEM NUMBER:
DATE: 7/20/04
EXHIBIT D: Potential Tree Removal List
Draft Resolution PC 2004-0079
TPM 2004-0058
6130
22
LO
6131
12
L0
6132
8
LO
6133
24
LO 2
Wilson Land Surveys
7600 Morro Rood. Ataucadcro. CA 93422
Phone: (805) 4W.445 • tax: (805) 4M-0912 • Email: )ame,.nvu;w11xm1anl%urveys.com
I'ARCEI_ MAP AT 03-0101 DRIVEWAY TREE LIST
POINT #
DIA INCHES
DESC
PRONGS
5337
15
LO
5937
12
WO
5943
7
LO
6058
12
LO
6148
6
WO
6177
19
LO
2
6178
16
LO
3
6181
24
LO
2
6182
24
LO
8
6184
18
LO
4
ITEM NUMBER:
DATE: 7/20/04
ITEM NUMBER: 6
f DATE: 7/20/04
1 �L i-A'DlA
Atascadero Planning Commission
Staff Report — Community Development Department
Tentative Tract Map 2004-0049 (Tract 2649) and Variance 2004-0003
6655 Tecorida Avenue
(Graves/Wilson Land Surveys)
RECOMMENDATION:
The Planning Commission adopt Resolution PC 2004-0080 approving Tentative Tract
Map 2004-0049 (Tract 2649), a request to establish four airspace units on one common
lot, based on findings and subject to conditions and approving Variance 2004-0003,
allowing for a reduction in the interior setbacks between Units 2 and 3 from 10 feet to 8
feet, based on findings.
SITUATION AND FACTS:
1. Applicant/Owners: David Graves, 4155 Carrizo Road, Atascadero, CA
93422
2. Project Address: 6655 Tecorida Avenue, Atascadero, CA 93422
APN 030-292-005
3. General Plan Designation: Medium Density Multi -family Residential
4. Zoning District: Residential Multi -family, 10 (Maximum 10 du/ac)
5. Site Area: .67 acre (approximately 29,478 square feet)
6. Existing Use: Under development for four individual apartment units
(Building permits 2002-1354-1357)
7. Environmental Status: Class 3 Categorical Exemption
ITEM NUMBER: 6
DATE: 7/20/04
DISCUSSION:
Background: The property fronts on Tecorida Avenue and is located east of San
Andres Avenue.
The site is located in an area of both multi and single-family residences, with
commercial uses located across Tecorida Avenue to the west. The General Plan and
Zoning designations are Multi -family Residential with a 10 unit per acre maximum.
There are several native trees and an intermittent creek on the property. Slopes are
slight to moderate, with a fairly flat area near Tecorida Avenue and rising at
approximately 20% to the east for about 30 feet. This rise, along with the creek area, is
as a natural divider between the guest parking lot and the living units.
Currently, there are 4 residential units under construction and nearing completion. The
units were permitted through the building permit process as a multi -family project of less
than 12 units.
City sewer will serve the property, and water is available from the Atascadero Mutual
Water Company.
ITEM NUMBER: 6
DATE: 7/20/04
Condominium Design: The proposed map will create four airspace units on one legal
lot of record. Each unit will have a one -car garage and a small, private yard of
approximately 300 square feet. There are four guest parking spaces located near the
project entrance along Tecorida Avenue, on the east side of the creek. A bridge is
under construction for access across the creek to the residential units.
Visitor Parking Area
I Tecorida Avenue
:3
Elm
r '
I � I Ad1EJ1� . •
Curb, Gutter. Sidewalk
i 1 ,
1.
#4111
1
I
\ \
7-11
OW40
Waterway area
Drainage Basin
The drainage system is composed of a series of pipes that will collect water from the
higher elevations and direct the flow into a basin located in the southwest corner of the
site. Staff is recommending a condition of approval for landscaping of the drainage
basin (Condition 14).
The subdivision is consistent with the General Plan Medium Density Residential Land
Use Designation and with approval of the Variance, the project will conform to the
Residential Multi -family Zoning regulations.
Public Improvements: The project has been conditioned to improve Tecorida Avenue
and construct concrete curb, gutter and sidewalk along the east side of the Tecorida
Avenue frontage, meandering around the native sycamores and connecting to the
existing sidewalk to the south (Conditions 39 and 40). In addition, the project has been
Bridge'
t , l l
'
I
1
r
'
1
\ \
7-11
OW40
Waterway area
Drainage Basin
The drainage system is composed of a series of pipes that will collect water from the
higher elevations and direct the flow into a basin located in the southwest corner of the
site. Staff is recommending a condition of approval for landscaping of the drainage
basin (Condition 14).
The subdivision is consistent with the General Plan Medium Density Residential Land
Use Designation and with approval of the Variance, the project will conform to the
Residential Multi -family Zoning regulations.
Public Improvements: The project has been conditioned to improve Tecorida Avenue
and construct concrete curb, gutter and sidewalk along the east side of the Tecorida
Avenue frontage, meandering around the native sycamores and connecting to the
existing sidewalk to the south (Conditions 39 and 40). In addition, the project has been
ITEM NUMBER: 6
DATE: 7/20/04
conditioned to provide a public access easement for all portions of the required sidewalk
that fall outside the public right-of-way (Condition 41).
Variance Request: The applicant is requesting a variance of the required 10 -foot
interior setback for residential units. The project plans, as originally approved for
construction, showed a 10 -foot setback. However, during the construction of the
retaining wall for the preservation of a 16 -inch White Oak, it was necessary to adjust the
front portion of Unit 2, resulting in an 8 -foot setback.
Environmental Review: The project as proposed qualifies for a Class 3 Categorical
exemption which exempts from CEQA review the conversion and/or construction of
multi -family projects of 4 units or less, which do not otherwise create a negative impact.
Variance Analysis:
//Iwo
03
Area maintaining required 10 -foot setback
c ilmn �
l
1
Modified Setback Area = 8 feet
�
1 �
\
61Y1�5 1 De
� l
�
i
1
low
I �
Y
am
o i 11 Z-3
1
1
1
iIX--M-Wakm mann
Retaining wall and tree
�M�
root L t AAV
�
^a►tro / `"
1 1
—
— �.. .Y
31191
r r
� I ,
Environmental Review: The project as proposed qualifies for a Class 3 Categorical
exemption which exempts from CEQA review the conversion and/or construction of
multi -family projects of 4 units or less, which do not otherwise create a negative impact.
Variance Analysis:
ITEM NUMBER: 6
DATE: 7/20/04
The Planning Commission must make the following findings:
1. The variance authorized does not constitute a grant of special privileges,
inconsistent with the limitations upon other properties in the vicinity and
zoning district in which such property is situated.
Staff Comment: The project would remain consistent with General Plan and
Zoning requirements for density, use, a nd public improvements.
2. There are special circumstances applicable to the property, including size,
shape, topography, location, or surroundings, and because of these
circumstances, the application of this title would deprive the property of
privileges enjoyed by other property in the vicinity and in the same zoning
district.
Staff Comment: The variance is being requested to allow for the preservation
of a native tree, provide a site design that minimizes impacts to the creek and
accommodates the existing topography.
3. The variance does not authorize a use that is not otherwise allowed in the
zoning district.
Staff Comment: The variance would not allow a use inconsistent with the
zoning ordinance.
4. The granting of the variance does not, under the circumstances and
conditions applied in the particular case, adversely affect the health or safety
of persons, is not materially detrimental to the public welfare, nor injurious to
nearby property or improvements.
Staff Comment: The reduced interior setback would continue to be consistent
with the intent of the zoning ordinance for setbacks and would meet the
requirements of the building and fire codes.
Approval of the variance would not establish a use that was not otherwise allowed, nor
would the approval adversely affect the health or safety of the surrounding community.
The 8 -foot setback appears to meet the intent of the Zoning Ordinance to provide for
natural light, ventilation and privacy and continues to meet building and fire code
requirements.
Conclusion: The proposed condominium map and variance, as conditioned, are
consistent with the 2002 General Plan and Zoning Ordinance and the airspace
configurations are consistent with the requirements of the Subdivision Ordinance. Staff
recommends the Planning Commission approve the Tentative Tract Map and Variance
as conditioned.
ITEM NUMBER: 6
DATE: 7/20/04
ALTERNATIVES:
1. The Commission may approve the project, subject to additional or revised project
conditions. The Commission's motion to approve needs to include any new or
revised project conditions.
2. The Commission may deny the project if it is found to be inconsistent with the
General Plan or any of the other required findings. The Commission's motion to
deny must include a finding basis for denial.
3. The Commission may continue the hearing and refer the item back to staff for
additional information or analysis. Direction should be given to staff and the
applicant on required information.
PREPARED BY: Kerry Margason, Associate Planner
ATTACHMENTS:
Attachment 1 -- Location Map (General Plan & Zoning)
Attachment 2 -- Draft Resolution PC 2004-0080
ITEM NUMBER: 6
DATE: 7/20/04
ATTACHMENT 1: Zoning Map
TTM 2004-0049 AND VARIANCE 2004-0003
6655 Tecorida Avenue
General Plan = MFR— 10
Zoning = RMF - 10
ITEM NUMBER: 6
DATE: 7/20/04
ATTACHMENT 2: Draft Resolution PC 2004-0080
TTM 2004-0049 AND VARIANCE 2004-0003
6655 Tecorida Avenue
DRAFT RESOLUTION NO. PC 2004-0080
A RESOLUTION OF THE PLANNING COMMISSION OF THE
CITY OF ATASCADERO APPROVING
TENTATIVE TRACT MAP 2004-0049 (Tract 2649), ESTABLISHING
FOUR AIRSPACE UNITS ON ONE COMMON LOT
AND VARIANCE 2004-0003, MODIFYING INTERIOR SETBACK REQUIREMENTS
AT 6655 Tecorida Avenue
(Graves)
WHEREAS, applications were received from David Graves, 4155 Carrizo Road,
Atascadero, California 93422 (Owner/Applicant), for a Tentative Tract Map to establish four
airspace units on one common lot and a Variance to modify required interior setbacks between
units 2 and 3; and,
WHEREAS, the proposed project has a General Plan Designation of Medium Density
residential (MDR) and is in conformance with the Land Use Element of the General Plan and all
other applicable General Plan policies; and,
WHEREAS, the site is located in the Residential Multr family — 10 du/ac (RMF -10)
Zoning District, which allows for the proposed use and density when certain findings are made;
and,
WHEREAS, a Categorical Exemption (Class 3(b)) was prepared for the project in
accordance with the requirements of the California Environmental Quality Act (CEQA); and,
WHEREAS, the Planning Commission held a duly noticed public hearing to consider the
proposed Tentative Tract Map application on June 20, 2004 at 7:00 p.m. and considered
testimony and reports from staff, the applicants, and the public.
NOW, THEREFORE, the Planning Commission takes the following actions:
SECTION 1. Findings for approval of condominium map The Planning Commission
finds as follows:
1. The proposed map, as conditioned, is consistent with the General Plan and
applicable zoning requirements.
2. The design and improvement of the proposed map, as conditioned, is consistent
with the General Plan and applicable zoning requirements.
3. The site is physically suitable for the density of development proposed.
ITEM NUMBER: 6
DATE: 7/20/04
4. The design and improvement of the proposed map will not cause substantial
environmental damage or substantially and unavoidably injure fish and wildlife or
their habitat.
5. The map is consistent with the character of the immediate neighborhood.
6. The design of the condominium map will not conflict with easements acquired by
the public at large for access through, or the use of property within, the proposed
subdivision; or substantially equivalent alternative easements are provided.
7. The proposed condominium map design and type of improvements proposed will
not came serious public health problems.
8. The proposed conversion will not displace a significant number of low-income or
moderate -income households or senior citizens at a time when no equivalent
housing is readily available in the City.
SECTION 2. Findings for approval of variance. The Planning Commission finds as
follows:
I. The variance authorized does not constitute a grant of special privileges,
inconsistent with the limitations upon other properties in the vicinity and zoning
district in which such property is situated.
2. There are special circumstances applicable to the property, including size, shape,
topography, location, or surroundings, and because of these circumstances, the
application of this title would deprive the property of privileges enjoyed by other
property in the vicinity and in the same zoning district.
3. The variance does not authorize a use that is not otherwise allowed in the zoning
district.
4. The granting of the variance does not, under the circumstances and conditions
applied in the particular case, adversely affect the health or safety of persons, is
not materially detrimental to the public welfare, nor injurious to nearby property
or improvements.
SECTION 3. Approval. The Planning Commission does hereby approve Tentative
Tract Map 2004-0049 to establish four airspace units on one common lot, and Variance 2004-
0003, modifying interior setbacks for Units 2 and 3, subject to the following Conditions and
Exhibits:
EXHIBIT A:
CEQA Exemption
EXHIBIT B:
Conditions of Approval
EXHIBIT C:
Teritative Tract Map 2004-0049
EXHIBIT D:
Variance Site Plan
ITEM NUMBER: 6
DATE: 7/20/04
On motion by Commissioner and seconded by Commissioner
, the foregoing resolution is hereby adopted in its entirety by the following
roll call vote:
AYES: ( )
NOES: ( )
ABSENT: ( )
ADOPTED:
ABSTAINED:
CITY OF ATASCADERO, CA
Bob Kelley
Planning Commission Chairperson
ATTEST:
Warren Frace
Planning Commission Secretary
ITEM NUMBER: 6
DATE: 7/20/04
EXHIBIT A: Proposed Categorical Exemption
TTM 2004-0049 AND VARIANCE 2004-0003
Finding of Exemption
TO: ® File Date Received for Filing
❑ Office of Planning and Research
1400 Tenth Street
Sacramento, CA 95814
FROM: City of Atascadero
Community Development Department
6905 EI Camino Real, Suite 6
Atascadero, CA 93422
SUBJECT: Filing of Notice of Determination in Compliance with Section 21152 of the Public Resources Code
Project Title: Tentative Tract Map 2004-0049 and Variance 2004-0003: David Graves
Project Location (Include County)
6655 Tecorida Avenue
Atascadero, CA 93422 (San Luis Obispo County)
Project Description
The project will create 4 airspace units allowing individual sale and ownership of four detached units within a multi-
family project with modified interior setbacks between units 2 and 3.
Name of Public Agency Approving Project: City of Atascadero
Name of Person or Agency Carrying Out Project: David Graves, 4155 Carrizo Road, Atascadero, CA 93422
Exempt Status:
❑ Ministerial (Sec. 21080 (b)(1); 15268)
❑ Declared Emergency (Sec. 21080(b)(3); 15269(a))
❑ Emergency Project (Sec.21080 (b)(4); 15269(b)(c))
® Categorical Exemption (Sec. 15303, construction or conversion of small structures)
Reasons why project is exempt:
Class 3(b) of the California Environmental Quality Act (CEQA) (Section 15303) exempts the conversion and/or
construction of small structures including multi -family projects of less than 4 units and which do not otherwise create
a negative impact.
Date: July 20, 2004
Kerry Margason
Associate Planner
CONTACT PERSON: WARREN FRACE, COMMUNITYDEVELOPMENT DIRECTOR, CITY OF ATASCADERO
805.461.5000
ITEM NUMBER: 6
DATE: 7/20/04
EXHIBIT B: Conditions of Approval /Mitigation Monitoring
TTM 2004-0049 AND VARIANCE 2004-0003
Conditions of Approval
Timing
Responsibility
Mitigation
TTM 2004.0049 AND VARIANCE 2004-0003
/Monitoring
Measure
PS: Planning Services
Address: 6655 Tecorida Avenue
BL: Business License
GP: Grading Permit
BS: Building vices
FD: Fire Department
BP: Building Permit
PD: Police Department
FI: Final Inspection
CE: City Engineer
TO: Temporary
WW: Wastewater
Occupancy
CA: City Attorney
F0: Final Occupancy
Standard Planning Conditions
1. The approval of this application shall become final, subject to
PM
PS
the completion of the conditions of approval, fourteen (14)
days following the Planning Commission approval unless
prior to the time, an appeal to the decision is filed as set forth
in Section 9-1.111(b) of the Zoning Ordinance.
2. Approval of this Tentative Tract Map shall be valid for two
PM
PS
years after its effective date. At the end of the period, the
approval shall expire and become null and void unless an
extension of time is granted pursuant to a written request
received prior to the expiration date.
3. The Community Development Department shall have the
PM
PS
authority to approve minor changes to the project that (1)
result in a superior site design or appearance, and/or (2)
address a construction design issue that is not substantive to
the Tentative Tract Map.
4. A final map drawn in substantial conformance with the
PM
PS
approved tentative map, and in compliance with all conditions
set forth herein, shall be submitted for review and approval in
accordance with the Subdivision Map Act and the City's
Subdivision Ordinance.
5. The subdivider shall defend, indemnify, and hold harmless
Ongoing
CA
the City of Atascadero or its agents, officers, and employees
against any claim or action brought to challenge an approval
by the city, or any of its entities, concerning the subdivision.
6. The final map shall be subject to additional fees for park or
PM
PS
recreation purposes (QUIMBY Act) as required by City
Ordinance.
Project Planning Conditions
7. Prior to final map, the applicant shall submit CC&R's for
FM
PS/Pw
review and approval by the Community Development
Department. The CC&R's shall record with the Final Map
and shall include the following:
a. Exclusive use easements for the private yard areas.
ITEM NUMBER: 6
DATE: 7/20/04
Conditions of Approval
Timing
Responsibility
Mitigation
TTM 20040049 AND VARIANCE 20040003
/Monitoring
Measure
PS: Planning Services
Address: 6655 Tecorida Avenue
BL: Business License
GP: Grading Permit
BS: Building Services
FD: Fire Department
BP: Building Permit
PD: Police Department
FI: Final Inspection
CE: City Engineer
TO: Temporary
WW: Wastewater
Occupancy
CA: City Attorney
F0: Final Occupancy
b. Provisions for maintenance of all common areas
including access, parking, street trees, any fencing
and landscaping.
C. A detailed list of each individual homeowner's
responsibilities for maintenance of the individual
units.
d. A provision for review and approval by the City
Community Development Department for any
changes to the CC&R's that relate to the above
requirements prior to the changes being recorded or
taking effect.
8. This map shall be for the approval of airspace units only. The
FM
PS
final map shall show one common lot and four airspace units.
9. Should the units be constructed and rented prior to the
FM
PS
recordation of the final map, all requirements set forth in
Government Code Section 66427.1 shall be met.
10. All construction and development shall be consistent with the
FM
PS/BS
approved plans, approved by the Community Development
Department.
11. The maximum percent of coverage for the lot, excluding
FO
PS
decks less than 30 inches from the ground, shall be 50%.
12. Each unit will be provided 100 square feet of enclosed
FO
PS/BS
storage space, exclusive of closets.
13. Each unit shall have individual trash storage space, screened
FO
PS/BS
from view by landscaping or enclosed within the garage area.
14. All drainage basins shall be landscaped. A landscape plan
FO
PS
shall be submitted to the Community Development
Department for review and approval, prior to recordation of
the final map and prior to installation of any landscaping.
City Engineer Standard Conditions
15. All public improvements shall be constructed in conformance
FM/FO
PW
with the City of Atascadero Engineering Department Standard
Specifications and Drawings and/or as directed by the City
Engineer.
ITEM NUMBER: 6
DATE: 7/20/04
Conditions of Approval
TTM 20040049 AND VARIANCE 2004-0003
Address: 6655 Tecorida Avenue
Timing
BL: Business License
GP: Grading Permit
BP: Building Permit
FI: Final Inspection
TO: Temporary
Occupancy
F0: Final Occupancy
Responsibility
/Monitoring
PS: Planning Services
BS: Building Services
FD: Fire Department
PD: Police Department
CE: City Engineer
WW: Wastewater
CA: City Attorney
Mitigation
Measure
16. In the event that the applicant is allowed to bond for the public
improvements required as a condition of this map, the
applicant shall enter into a Subdivision Improvement
Agreement with the City Council.
17. An engineer's estimate of probable cost shall be submitted for
review and approval by the City Engineer to determine the
amount of the bond.
18. The Subdivision Improvement Agreement shall record
concurrently with the Final Map.
19. An encroachment permit shall be obtained prior to the
issuance of building permit.
20. The applicant shall enter into a Plan Check/Inspection
agreement with the City.
21. A six (6) foot Public Utility Easement (PUE) shall be provided
contiguous to the Tecorida Ave property frontage.
22. The applicant shall be responsible for the relocation and/or
alteration of existing utilities.
23. The applicant shall install all new utilities (water, gas, electric,
cable TV and telephone) underground. Utilities shall be
extended to the property line frontage of each lot or its public
utility easement.
24. The applicant shall monument all property corners for
construction control and shall promptly replace them if
disturbed.
25. The applicant shall acquire title interest in any off-site land
that may be required to allow for the construction of the
improvements. The applicant shall bear all costs associated
with the necessary acquisitions. The applicant shall also gain
concurrence from all adjacent property owners whose ingress
and egress is affected by these improvements.
26. Slope easements shall be provided as needed to
accommodate cut of fill slopes.
27. Drainage easements shall be provided as needed to
accommodate both public and private drainage facilites.
28. A preliminary subdivision guarantee shall be submitted for
review in conjunction with the processing of the Tract map.
ITEM NUMBER: 6
DATE: 7/20/04
Conditions of Approval
TTM 20040049 AND VARIANCE 20040003
Address: 6655 Tecorida Avenue
Timing
BL: Business License
GP: Grading Permit
BP: Building Permit
FI: Final Inspection
TO: Temporary
Occupancy
F0: Final Occupancy
Responsibility
/Monitoring
PS: Planning Services
BS: Building Services
FD: Fire Department
PD: Police Department
CE: City Engineer
WW: Wastewater
CA: City Attorney
Mitigation
Measure
29. All existing and proposed utility, pipeline, open space, or other
easements are to be shown on the final map. If there are
building or other restrictions related to the easements, they
shall be noted on the final map. The applicant shall show all
access restrictions on the final map.
30. The final map shall be signed by the City Engineer prior to the
map being placed on the agenda for City Council acceptance.
31. Prior to recording the Tract map, the applicant shall submit a
map drawn in substantial conformance with the approved
tentative map and in compliance with all conditions set forth
herein. The final map shall be submitted for review and
approval by the City in accordance with the Subdivision Map
Act and the City's Subdivision Ordinance.
32. Prior to recording the Tract map, the applicant shall set
monuments at all new property corners. A registered civil
engineer or licensed land surveyor shall indicate by certificate
on the Tract map, that corners have been set or shall be set
by a date specific and that they will be sufficient to enable the
survey to be retraced.
33. Prior to recording the Tract map, the applicant shall pay all
outstanding plan check/inspection fees.
34. Prior to recording the map, the applicant shall complete all
improvements required by these conditions of approval.
35. Prior to recording the Tract map, the applicant shall have the
map reviewed by all applicable public and private utility
companies (cable, telephone, gas, electric, Atascadero
Mutual Water Company). The applicant shall obtain a letter
from each utility company indicating their review of the map.
The letter shall identify any new easements that may be
required by the utility company. A copy of the letter shall be
submitted to the City. New easements shall be shown on the
Tract map.
36. Upon recording the final map, the applicant shall provide the
City with a black line clear Mylar (0.4 mil) copy and a blue line
print of the recorded map.
37. Prior to the final inspection of any public improvements, the
applicant shall submit a written statement from a registered
civil engineer that all work has been completed and is in full
compliance with the approved plans.
ITEM NUMBER: 6
DATE: 7/20/04
Conditions of Approval
Timing
Responsibility
Mitigation
TTM 20040049 AND VARIANCE 2004-0003
/Monitoring
Measure
PS: Planning Services
Address: 6655 Tecorida Avenue
BL: Business License
GP: Grading Permit
BS: Building Services
FD: Fire Department
BP: Building Permit
PD: Police Department
FI: Final Inspection
CE: City Engineer
TO: Temporary
WW: Wastewater
Occupancy
CA: City Attorney
F0: Final Occupancy
38. Prior to the final inspection, the applicant shall submit a
written certification from a registered civil engineer or land
surveyor that all survey monuments have been set as shown
on the final map.
City Engineer Project Conditions
39. This project is required to pave Tecorida Ave, with concrete
FM
PW
Curb, Gutter, and Sidewalk on the east side, from the end of
the existing paving on the south side of the project to the
north property line, to provide for orderly development and
traffic circulation.
40. Frontage improvements required are concrete curb, gutter
FM
PW
and sidewalk on the east side of Tecorida Ave, meandering
around the native Sycamore trees as shown on Exhibit C
attached hereto, and concrete drive approach at the driveway
to allow the drainage to be conveyed down Tecorida.
41. Prior to recordation of the final map, the applicant shall
provide a public access easement along all portions of the
sidewalk that fall outside the public right-of-way.
42. A bridge will be placed within the driveway, across the creek
FM
PW
area for access to the residential units.
Atascadero Mutual Water Company Project Conditions
43. Before recordation of the final map, the applicant shall
FM
AMWC
submit plans to AMWC for the water distribution facilities
needed to serve the project. AMWC shall review and
approve the plans before construction begins on the water
system improvements. All new water distribution facilities
shall be constructed in conformance with AMWC Standards
and Details and the California Waterworks Standards
(Code of Regulations Title 22, Division 4, Chapter 16). All
cross -connection devices shall conform to AWWA and
California Department of Health Services standards.
44. Before the start of construction on the water system
improvements, the applicant shall pay all installation and
connection fees required by AMWC. Subject to the
approval of AMWC, the applicant may enter into a
"deferred connection" agreement.
45. Before issuance of building permits, the applicant shall
obtain a "Will Serve" letter from AMWC for the newly
created lots within the subdivision.
ITEM NUMBER: 6
DATE: 7/20/04
Conditions of Approval
Timing
Responsibility
Mitigation
TTM 20040049 AND VARIANCE 2004-0003
/Monitoring
Measure
PS: Planning Services
Address: 6655 Tecorida Avenue
BL: Business License
GP: Grading Permit
BS: Building Services
FD: Fire Department
BP: Building Permit
PD: Police Department
FI: Final Inspection
CE: City Engineer
TO: Temporary
WW: Wastewater
Occupancy
CA: City Attorney
F0: Final Occupancy
46. The applicant shall obtain a separate landscape -irrigation
meter from AMWC for the common areas within the project.
Landscaping for common areas shall be drought -tolerant.
The landscaping for common areas shall conform to the
mitigation measures noted in Table II -7, Hydrology and
Water Quality, of the General Plan 2025. The applicant
shall keep the use of turf grass in common area
landscaping and in other areas to a minimum.
47. Before construction of the water system improvements,
AMWC shall review and approve the landscape plans for
the common areas within the project.
48. The applicant is responsible for designing and constructing
water system improvements that will provide water at
pressures and flows adequate for the domestic and fire
protection needs of the project.
EXHIBIT C: Tentative Tract Map
TTM 2004-0049 AND VARIANCE 2004-0003
'r T -r--
1112
Q11 V
y
�.ew•••.n...q R
I `�1111�
t�^111i1
s
3��
+�►.
i 14
i
`
ITEM NUMBER: 6
DATE: 7/20/04
ITEM NUMBER: 6
DATE: 7/20/04
EXHIBIT D: VARIANCE SITE PLAN
TTM 2004-0049 AND VARIANCE 2004-0003
ITEM NUMBER: 7
DATE: 07/20/04
Atascadero Planning Commission
Staff Report - Community Development Department
Tree Removal Permit
TRP 2004-0053
(3858 Orillas Way: Quigley)
SUBJECT:
Request to remove three (3) Live Oak trees, one of which is over 24 -inches in diameter,
in conjunction with the development of a 2,380 square -foot single family home with an
attached 800 square foot garage located at 3858 Orillas Way.
RECOMMENDATION:
Staff recommends:
The Planning Commission adopt Resolution PC 2004-0084 to approve the request to
remove three native oak trees subject to the guidelines and mitigation required by the
Atascadero Native Tree Ordinance.
Situation and Facts:
1. Applicant: Robert Quigley, 7805 Santa Ynez Avenue,
Atascadero, CA 93422
2. Representative: Robert Quigley, 7805 Santa Ynez Avenue,
Atascadero, CA 93422
3. Certified Arborist: Steven G. Alvarez, 1615 Lupine Lane, Templeton,
CA 93465
4. Project Address: 3858 Orillas Way
Atascadero, CA 93422
APN 049-033-046
07-20-04 TRP 2004-0053 Orillas Way.PC-SR
ITEM NUMBER: 7
DATE: 07/20/04
-3
The project site contains seven (7) Live Oak trees that, according to the arborist, vary
from poor to fair condition on an approximately 0.2 acre lot. The applicant plans to build
a 2,380 square foot single-family residence with an attached 800 square foot garage
and remove three (3) Live Oak trees ranging from 48" dbh, 17" dbh, and 12" dbh. Three
Live Oak trees will be impacted by onsite grading and construction and will require tree
protective fencing. Tree #4 will be impacted 50% and will be subject to a mitigation
deposit (Exhibit A, Condition 3).
The City of Atascadero's Tree Ordinance requires that mitigation for native tree
removals be implemented as a condition of approval. Staff is recommending that the
applicant replant trees or pay into the tree replacement fund to mitigate removal of the
trees. The proposed mitigation is shown in the following table.
FINDINGS:
Pursuant to the Tree Ordinance (Ordinance No. 214), "decisions on native tree removals
of 24 -inch dbh-size or larger shall be made by the Planning Commission." In
considering any tree removal request, at least one of the below stated following findings
must be made. Staff has identified finding #5 as appropriate for the application request.
1) The tree is dead, diseased or injured beyond reclamation, as certified by a
tree condition report from an Arborist;
2) The tree is crowded by other healthier native trees, thinning (removal) would
promote healthier growth in the trees to remain, as certified by a tree
condition report from an Arborist;
3) The tree is interfering with existing utilities and/or structures, as certified by a
report from the Site Planner;
4) The tree is inhibiting sunlight needed for existing and/or proposed active or
passive solar heating or cooling, as certified by a report from the Site
Planner;
07-20-04 TRP 2004-0053 Orillas Way.PC-SR
NONDECIDUOUS NATIVE TREE REMOVAL
INCHES
TYPE
CONDITION
LOCATION
1.
48"
LIVE OAK
POOR/FAIR
3858 ORILLAS
2. 17"
LIVE OAK
POOR
3. 12"
LIVE OAK
POOR
TOTAL
= 77"
PLANT FOUR (4) FIFTEEN GALLON AND ONE (1) FIVE GALLON
LIVE OAK TREES OR PAY $641.67 INTO TREE MITIGATION FUND
FINDINGS:
Pursuant to the Tree Ordinance (Ordinance No. 214), "decisions on native tree removals
of 24 -inch dbh-size or larger shall be made by the Planning Commission." In
considering any tree removal request, at least one of the below stated following findings
must be made. Staff has identified finding #5 as appropriate for the application request.
1) The tree is dead, diseased or injured beyond reclamation, as certified by a
tree condition report from an Arborist;
2) The tree is crowded by other healthier native trees, thinning (removal) would
promote healthier growth in the trees to remain, as certified by a tree
condition report from an Arborist;
3) The tree is interfering with existing utilities and/or structures, as certified by a
report from the Site Planner;
4) The tree is inhibiting sunlight needed for existing and/or proposed active or
passive solar heating or cooling, as certified by a report from the Site
Planner;
07-20-04 TRP 2004-0053 Orillas Way.PC-SR
ITEM NUMBER: 7
DATE: 07/20/04
5) The tree is obstructing proposed improvements that cannot be reasonably
designed to avoid the need for tree removal, as certified by a report from the
Site Planner and determined by the Community Development Department
based on the following factors:
• Early consultation with the City;
• Consideration of practical design alternatives;
• Provision of cost comparisons (from applicant) for practical design
alternatives;
• If saving tree eliminates all reasonable uses of the property; or
• If saving the tree requires the removal of more desirable trees.
.� 101eal &IX'J,
The applicant has submitted a tree protection plan with arborist notation. The trees have
been determined to be obstructing proposed improvements and in poor to fair health.
PREPARED BY: Lisa Wilkinson, Assistant Planner
ATTACHMENTS:
Attachment 1: Aerial Photo
Attachment 2: Draft Resolution PC 2004-0084
Exhibit A: Conditions of Approval
Exhibit B: Arborist Letter
Exhibit C: Tree Protection Plan
07-20-04 TRP 2004-0053 Orillas Way.PC-SR
ITEM NUMBER: 7
DATE: 07/20/04
Attachment 1: Aerial
Project Site
vi
07-20-04 TRP 2004-0053 Orillas Way.PC-SR
ITEM NUMBER: 7
DATE: 07/20/04
Attachment 2: Draft Resolution PC 2004-0084
Tree Removal - TRP 2004-0053
DRAFT RESOLUTION PC 2004-0084
A RESOLUTION OF THE PLANNING COMMISSION
OF ATASCADERO APPROVING A TREE REMOVAL PERMIT
TO ALLOW THE REMOVAL OF THREE NATIVE OAK TREES
LOCATED AT 3858 ORILLAS WAY.
(TRP 2004-0053/Quigley)
WHEREAS, an application for a Tree Removal Permit has been received from, Robert
Quigley, 7805 Santa Ynez Ave., CA 93422, to allow the removal of three native oak trees located
at 3858 Orillas Way; and,
WHEREAS, the proposed project is located within the Single Family Residential land use
designation of the City of Atascadero's General Plan Land Use Diagram; and,
WHEREAS, the proposed project is located in the Residential Single Family X (RESF-X)
zoning district; and,
WHEREAS; the Planning Commission reviewed the proposed Tree Removal application on
July 20, 2004, at 7:00 p.m. at the Lake Pavilion located at 9315 Pismo Avenue and considered
testimony and reports from staff, the applicants, and the public; and,
NOW, THEREFORE, the Planning Commission takes the following actions:
SECTION 1. Findings for Approval of Tree Removal Permit. The Planning
Commission finds as follows:
The tree is obstructing proposed improvements that cannot be reasonably designed to avoid
the need for tree removal, as certified by a report from the Site Planner and determined by
the Community Development Department based on the following factors:
• Early consultation with the City;
• Consideration of practical design alternatives;
• Provision of cost comparisons (from applicant) for practical design alternatives;
• If saving tree eliminates all reasonable uses of the property; or
• If saving the tree requires the removal of more desirable trees; and,
07-20-04 TRP 2004-0053 Orillas Way.PC-SR
ITEM NUMBER: 7
DATE: 07/20/04
SECTION 2. Approval. The Planning Commission hereby approves Tree Removal Permit
2004-0053 subject to the following Conditions and Exhibits:
Exhibit A: Conditions of Approval
Exhibit B: Arborist Letter
Exhibit C: Tree Protection Plan
On motion by Commissioner , and seconded by Commissioner the foregoing
resolution is hereby adopted in its entirety by the following roll call vote:
AYES: ( )
NOES: ( )
ABSENT: ( )
ABSTAIN: ( )
CITY OF ATASCADERO, CA
Bob Kelley
Planning Commission Chairperson
Attest:
Warren M. Frace
Planning Commission Secretary
07-20-04 TRP 2004-0053 Orillas Way.PC-SR
ITEM NUMBER:
DATE: 07/20/04
Exhibit A: Conditions of Approval
Tree Removal - TRP 2004-0053
Conditions of Approval
Timing
Responsibility
Mitigation
TRP 2004-0053
/Monitoring
Measure
PR: Prior to Removal
BL: Business License
PS: Planning Services
BP: Building Permit
BS: Building Services
TO: Temporary Occupancy
FD: Fire Department
F0: Final Occupancy
PD: Police Department
CE: City Engineer
WW: Wastewater
CA: City Attorney
Planning Services
1. The applicant shall pay $641.67 into the tree fund as
PR
PS
mitigation for the tree removal or plant four (4) 15
gallon and one five (5) gallon native Live Oak trees,
or equivalent.
2. Replacement trees shall be monitored for a 1 -year
FO
PS
period and maintained as specified by a certified
arborist to insure the trees become established.
3. A mitigation deposit shall be collected for Tree #4 in
BP or GP and
PS/Arborist
the amount of $283.33. The deposit will be refunded
FO
to the applicant if the tree is in equivalent health prior
to final occupancy, and verified by a letter from the
project arborist.
Evergreen Native Trees (inches) Totals
dbh notes
1 48 -inches
2 17 -inches
3 12 -inches
Total 77 -inches 77 -inches
Mitigation Requirement
Tree replacements: 13 five gal trees
or equivalent
Tree Fund Payment: $ 641.67 $ 641.67
07-20-04 TRP 2004-0053 Orillas Way.PC-SR
ITEM NUMBER: 7
DATE: 07/20/04
Exhibit 13: Arborist Letter
Tree Removal - TRP 20040053
Steven G. Alvaro Arborisl
1615 Lupine Lazne
Templeton, CA. 93465
(805) 431-2591
June 17, 2004
Mr. Robert (Quigley
7805 Santa YnC7 Road
Atascadero. CA 93422
Re: Addendum tier drainage impact to remaining oak trees for lot 8 tract 2317.
The native soil on this development has a high percent of sand allowing excess water to
leach Through the soil profile quickly I)0 to this soil condition the resulting drainage:
impect to the remaining. txik Inks for this lot development can be evaluated as having
little to no impact,
Please let me know if l can be of any future assistance to you for this project.
Steven G. Alvarez
Cer if icd Arborist �i WC -051 1
RECEIVED
JUL 1 &64
COMMUNITY DEVEI.OP4tENT
07-20-04 TRP 2004-0053 Orillas Way.PC-SR
Exhibit C: Tree Protection Plan
Tree Removal - TRP 2004-0053
Ri(ii LL. Kl1 •YL
X
s:..
ITEM NUMBER: 7
DATE: 07/20/04
R7C
07-20-04 TRP 2004-0053 Orillas Way.PC-SR