HomeMy WebLinkAbout2006-091 i
RESOLUTION NO 2006-091
RESOLUTION OF THE CITY COUNCIL
OF THE CITY OF ATASCADERO, CALIFORNIA, APPROVING
TENTATIVE TRACT MAP 2004-0059, A FIVE LOT SUBDIVISION
CONSISTENT WITH A MASTER PLAN OF DEVELOPMENT
ON APN 049-022-011
(2865 Ferrocarril Road / Tharp/Beck)
WHEREAS, an application has been received from Gary Tharp and Jim Beck (2865
Ferrocarril Road, CA 93422), Owner and Applicants, to consider a project consisting of a Zone
Change from RS (Residential Suburban) to RS / PD-16 (Residential Suburban with Planned
Development Overlay #16) with the adoption of a Master Plan of Development, and a five-lot
residential Tentative Tract Map on APN 049-022-011, and,
WHEREAS, the site's General Plan Designation is SE (Suburban Estate), and,
WHEREAS, the Planning Commission has recommended that the site's Zoning District
be changed from RS (Residential Suburban) to RS/PD-16 (Residential Suburban/Planned
Development Overlay#16), and,
WHEREAS, an Initial Study and Draft Mitigated Negative Declaration 2006-0022 were
prepared for the project and made available for public review in accordance with the
requirements of the California Environmental Quality Act(CEQA), and,
WHEREAS, the laws and regulations relating to the preparation and public notice of
environmental documents, as set forth in the State and local guidelines for implementation of the
California Environmental Quality Act(CEQA) have been adhered to, and,
WHEREAS, a timely and properly noticed Public Hearing upon the subject Tentative
Tract Map application was held by the Planning Commission of the City of Atascadero at which
hearing evidence, oral and documentary, was admitted on behalf of said Master Plan of
Development; and,
WHEREAS, the City Council of the City of Atascadero, at a duly noticed Public Hearing
held on September 26, 2006, studied and considered Tentative Tract Map 2004-0059, after first
studying and considering the Proposed Mitigated Negative Declaration prepared for the project;
and,
NOW THEREFORE, the City Council of the City of Atascadero takes the
following actions
City of Atascadero
Resolution No 2006-091
Page 2 of 16
SECTION 1 Findings of Approval for Tentative Tract Map, the City Council of the
City of Atascadero finds as follows
1 The proposed subdivision, design and improvements as conditioned, is consistent with
the General Plan and applicable zoning requirements
2. The proposed subdivision, as conditioned, is consistent with the proposed Planned
Development Overlay District#16 Master Plan of Development(CUP 2005-0171)
3 The site is physically suitable for the type of development proposed.
4 The site is physically suitable for the density of development proposed.
5 The design and improvement of the proposed subdivision will not cause substantial
environmental damage or substantially and unavoidably inure fish and wildlife or their
habitat.
6 The design of the subdivision will not conflict with easements acquired by the public at
large for access through, or the use of property within, the proposed subdivision, or
substantially equivalent alternative easements are provided.
7 The proposed subdivision design and type of improvements proposed will not be
detrimental to the health, safety or welfare of the general public
SECTION 2. Approval. The City Council of the City of Atascadero, in a regular
session assembled on September 26, 2006, resolved to approve Tentative Tract Map (TTM 2004-
0059) subject to the following:
1 Exhibit A. Tentative Tract Map (Tract 2681)
2. Exhibit B Conditions of Approval / Mitigation Monitoring Program.
�wr.
City of Atascadero
Resolution No 2006-091
Page 3 of 16
1�rr✓
On motion by Council Member Clay and seconded by Council Member Pacas, the
foregoing Resolution is hereby adopted in its entirety on the following roll call vote
AYES Council Members Clay, Pacas and Mayor O'Malley
NOES None
ABSENT Council Member Luna
One Vacancy
ADOPTED- September 26, 2006
CITY ATASCADER
y.
Tom O'Malley, May
ATTEST
L /
Marcia -AAcClure Torgeison, C M.CC/, City Jerk
APPROV)D S -ru-
Patrick L. Enrtglt, City Attorney
City of Atascadero
Resolution No 2006-091
Page 4 of 16
Exhibit A:Tentative Tract Map 2004-0059
it
Ila
i a ;�� � �.+? �` 4• ,,/ Y rte:•!
Y• i � 4 n �(
�!1
y A
Open spacer n{ k *
easement with
public access
trail to Salinasi
River
S'
City of Atascadero
Resolution No 2006-091
Page 5 of 16
Exhibit B:Conditions of Approval/Mitigation Monitoring Program
Tentative Tract Map 2004-0059
Conditions of Approval/ Timing Responsibility Mitigation
Mitigation Monitoring Program /Monitoring Measure
GP Grading Pemd PS.Planning Services
BP,Building Permit BS.Building Services
2865 Ferrocarril Road SIP Subdivision FD:Fire Departinenl
Inprovernent Plans PD:Police Departrnent
Vesting Tentative Tract Map FM:Final Map CE.City Engineer
Ti7Temporary WW:Wastewater
TTM 20040059 occupancy CA city Attorney
FI:Final inspection AMWC.Water Co".
F0:Final Occupancy
Planning Services
1 The approval of this Tentative Tract Map shall become final and FM PS
effective following approval of Zone Change 2005-0107 and CUP
2005-0171
2. Approval of this Tentative Tract Map shall be valid for two years after FM PS
its effective date. At the end of the period, the approval shall expire
and become null and void unless an extension of time is granted
pursuant to a written request received prior to the expiration date.
3. The Community Development Department shall have the authority FM PS
to approve minor changes to the project that(1)result in a superior
site design or appearance, and/or(2)address a design issue that is
not substantive to the Tentative Tract Map and that the Final Map is
in substantial conformance with the Tentative Map.
4 The Tract Map shall be subject to additional fees for park or FM PS
recreation purposes(QUIMBY Act)as required by City Ordinance.
5 The granting of this entitlement shall apply to the property located at On going PS
2865 Ferrocarril Road (APN 049-022-011)regardless of owner
6 The Final Map shall be drawn in substantial conformance with the FM PS
approved tentative map and in compliance with all conditions set
forth herein, shall be submitted for review and approval in
accordance with the Subdivision Map Act and the City's Subdivision
Ordinance.
7 The subdivider shall defend indemnify and hold harmless the City FM PS
of Atascadero or its agents officers and employees against any
claim or action brought to challenge an approval by the city or any
of its entities concerning the subdivision.
8. Prior to recordation of the final map the applicant shall submit,for BP PS
review and approval:
• Fencing plan including materials and treatments
■ Trail signing plan
• Landscaping plan for all disturbed site area.
• Project shall not be gated
. 9 Affordable Housing Requirement: The applicant shall either deed FM, BP PS,CE
restrict a minimum of 1 residential unit for 30 years at a moderate
City of Atascadero
Resolution No 2006-091
Page 6 of 16
Conditions of Approval/ Timing Responsibility Mitigation
Mitigation Monitoring Program /Monitoring Measure
GP Grading Pemd PS.Planning Services
BP'Building Permit BS.Budding Services
2865 Ferrocarril Road SIP,Subdivision FD:Fire DepaVent
Inpmvernent Plans PD:Police DepaVnent
Vesting Tentative Tract Map FM:Final Map CE.City Engineer
TO:Temporary WW:Wastewater
TTM 20040059 sway Ca City Attorney
FI:Finalinspec6on AMWC:Water Cornp.
F0:Final Occupancy
income rate with recordation of the final map or shall pay an in lieu
fee equal to 5%of the construction valuation of each unit.
10 Workforce Housing: FM, BP PS, CE
Prior to recordation of final map the applicant shall enter into a legal
agreement with the City to reserve Y2 of the units for sale to residents
or workers within the City of Atascadero, including the affordable
units. The agreement shall include the following provisions.
• The units shall be offered for sale to residents or workers
within the City of Atascadero for a minimum of 60-days.
During this time period offers may only be accepted from
Atascadero residents or workers;
■ The applicant shall provide reasonable proof to the City that
at least one of the qualified buyers is a resident or worker
within the City Limits of Atascadero
• The Atascadero resident or worker restriction shall apply to
the initial sale only-
The applicant shall identify which units will be reserved;and the
City Attorney shall approve the final form of the agreement.
11 The emergency services and facility maintenance costs listed FM PS/PW
below shall be 100%funded by the project in perpetuity The
service and maintenance costs shall be funded through a
community facilities district established by the City at the
developer's cost. The funding mechanism must be in place prior
to or concurrently with acceptance of the final maps The funding
mechanism shall be approved by the City Attorney City Engineer
and Administrative Services Director prior to acceptance of any
final map The administration of the above mentioned funds shall
be by the City Developer agrees to participate in the community
facilities district and to take all steps reasonably required by the
City with regard to the establishment of the district and
assessment of the property
• All Atascadero Police Department service costs to the project.
• All Atascadero Fire Department service costs to the project.
• Off-site common City of Atascadero park facilities maintenance
service costs related to the project.
12. All tract maintenance costs listed below shall be 100%funded by the FM PS/PW
project in perpetuity The service and maintenance cost shall be
funded through a Maintenance Agreement established by the
developer subject to City approval. The Agreement must be in place
prior to or concurrently with acceptance of any final maps. The
Agreement shall be approved by the City Attorney City Engineer
and Administrative Services Director prior to acceptance of any Final
Map. The administration of the above mentioned funds, and the
City of Atascadero
Resolution No 2006-091
Page 7 of 16
Conditions of Approval/ Timing Responsibility Mitigation
Mitigation Monitoring Program /Monitoring Measure
GP Grading Perni t PS:Planning Services
BP Building Pemd BS,Building Services
2865 Ferrocarril Road SIP subdivision FD:FreDeparonem
Ir provernenl Plans PD:Police Depa Irnent
Vesting Tentative Tract Map FM:Final Map CE:City Engineer
TTM 20040059 �up�a" c�c�Attorrny
FI:Final inspection AMWC:Water Co np.
FO:Final Occupancy
coordination and performance of maintenance activities, shall be the
responsibility of the home owners.
• All streets, bridges, sidewalks, streetlights, street signs, roads
emergency access roads, emergency access gates, and sewer
mains within the project.
■ All parks,trails recreational facilities and like facilities
• All open space and native tree preservation areas
■ All drainage facilities and detention basins
• All creeks flood plains floodways wetlands and riparian
habitat areas
13. In conjunction with the recordation of the final tract map,the FM PS,CE
developer shall record an Open Space Easement and a Pedestrian
Access Easement,reviewed and approved by the Community
Development Department. These easements shall also be shown
on the face of the final tract map and shall be consistent with the
easement shown on the approved tentative tract map
14 Prior to recordation of the final map the applicant shall submit,for BP PS
review and approval:
■ Fencing plan,including materials and treatments
■ Landscaping plan for all disturbed site area.
• Project shall not be gated
14 The Developer shall construct a Class 1 trail for pedestrian and BP/GP PS/PW
equestrian access. The trail shall begin on the north side of the
Paseo Del Lago and Chico Road intersection and shall extend
northerly across the project property to the property boundary with
the Atascadero Mutual Water Company's 'River Parcel. The trail
shall meet the following requirements.
■ The trail shall be 6 feet wide along the Chico Road extension,
widening to 8-feet within the Open Space Easement crossing
the project property
• The trail shall be constructed with a decomposed granite
finished surface.
■ The Chico Road improvements and construction of the trail shall
be in conformance with all City requirements and the agreement
entered into between Mr Beck and Mr Munoz,dated August
23 2006
Building Services
fir►'
City of Atascadero
Resolution No 2006-091
Page 8 of 16
Conditions of Approval/ Timing Responsibility Mitigation
Mitigation Monitoring Program /Monitoring Measure
GP Grading Permit PS:Planting Services
BPBuilding Pemrt BS.Building Services
2865 Ferrocarril Road SIP'Subdivision FD:Fie Department
Improvement Plans PD:Police Department
Vesting Tentative Tract Map FM:Final Map CE:City Engineer
TO:Temporary WW Wastewater
TTM 20040059 Occupancy CA City Attorney
FI:Final inspection AMWC:Water Comp.
F0:Final Occupancy
15 A soils investigation prepared by a licensed Geotechnical BP FM
Engineer is to be provided for the project. The report is to be
provided at the time of building permit submittal along with the
building plans for review by the Building Division.
Recommendations contained in the report are to be incorporated
into the project plans
Fire Marshal
16 All street names shall be reviewed and approved by the FM PS, FD PD
Community Development Department,the Fire Department, and
the Police Department. Street names and addresses shall be
approved and assigned prior to recordation of the final map
17 Note on plans that fire lanes shall be delineated to restrict parking BP PS/FD
as required by the Fire Authority
Engineering Conditions.
City Engineer Project Conditions
18 Applicant shall construct the extension of Chico Road to the 401A BP CE
City Standard modified as shown on the tentative map.
19 A railing shall be provided along the top of the retaining wall on GP, BP CE, BS
Chico Road adjacent to the horse trail/pedestrian access in
conformance with the California Building Code
City Engineer Standard Conditions
20 In the event that the applicant bonds for the public improvements GP, BP CE
required as a condition of this map, the applicant shall enter into a
Subdivision Improvement Agreement with the City Council.
21 An engineer's estimate of probable cost shall be submitted for review GP, BP CE
and approval by the City Engineer to determine the amount of the
bond.
22. The Subdivision Improvement Agreement shall record concurrently FM CE
with the Final Map.
23. A six (6) foot Public Utility Easement (PUE) shall be provided GP, BP CE
contiguous to the property frontage.
24 The applicant shall acquire title interest in any off-site land that may GP,BP CE
be required to allow for the construction of the improvements. The
applicant shall bear all costs associated with the necessary
acquisitions. The applicant shall also gain concurrence from all
adjacent property owners whose ingress and egress is affected by
these improvements.
City of Atascadero
Resolution No 2006-091
Page 9 of 16
Conditions of Approval/ Timing Responsibility Mitigation
Mitigation Monitoring Program /Monitoring Measure
GP-Grading Permit PS.Planning Services
2865 Ferrocarril Road SIP,Subdivision FD:Re Department
VestingTentative Tract Ma InprFinalMtPlans PD:CkEngPoliGe epartinent
P FM:Final Map CE City Engineer
TTM 20040059 TO:Temporary WW:Wastewater
Ocapancy CA City Attorney
FI:Final inspection AMWC:Water Comp.
FO:Final Occupancy
25. Slope easements shall be obtained by the applicant as needed to GP,BP CE
accommodate cut or fill slopes.
26 Drainage easements shall be obtained by the applicant as needed to GP,BP CE
accommodate both public and private drainage facilities.
27 A preliminary subdivision guarantee shall be submitted for review in FM CE
conjunction with the processing of the tract map.
29 The final map shall be signed by the City Engineer prior to the map FM CE
being placed on the agenda for City Council acceptance.
30 Prior to recording the tract map, the applicant shall pay all FM CE
outstanding plan check/inspection fees.
31 Prior to recording the map the applicant shall bond for or complete FM CE
all improvements required by these conditions of approval.
32. Prior to recording the tract map the applicant shall bond for or set FM CE
monuments at all new property corners.A registered civil engineer or
*4w licensed land surveyor shall indicate by certificate on the parcel map
that comers have been set or shall be set by a date specific and that
they will be sufficient to enable the survey to be retraced.
33. Prior to recording the tract map the applicant shall submit a map FM CE
drawn in substantial conformance with the approved tentative map
and in compliance with all conditions set forth herein. The map shall
be submitted for review and approval by the City in accordance with
the Subdivision Map Act and the City's Subdivision Ordinance.
34 All existing and proposed utility pipeline open space or other FM CE
easements are to be shown on the final/parcel map If there are
building or other restrictions related to the easements they shall be
noted on the final/parcel map The applicant shall show all access
restrictions on the final/parcel map
35. Prior to recording the tract map the applicant shall have the map FM CE
reviewed by all applicable public and private utility companies(cable,
telephone, gas, electric, Atascadero Mutual Water Company). The
applicant shall obtain a letter from each utility company indicating
their review of the map. The letter shall identify any new easements
that may be required by the utility company A copy of the letter shall
be submitted to the City New easements shall be shown on the
parcel map.
36. Prior to the issuance of building permits the applicant shall submit GP, BP CE
plans and supporting calculations/reports including street
improvements, underground utilities, composite utilities, and
grading/drainage plans prepared by a registered civil engineer for
City of Atascadero
Resolution No 2006-091
Page 10 of 16
Conditions of Approval/ Timing Responsibility Mitigation
Mitigation Monitoring Program /Monitoring Measure
GP*Grading Pemut PS.Planning Semites
BP Building Pemrt BS.Building Services
2865 Ferrocarril Road SIP Subdivision FD:Fire Depanrrient
Improvement Plans PD:Police Departrnent
Vesting Tentative Tract Map FM:Final Map CE.City Engineer
TTM 2004-0059 TO:Temporary WW:Wastewater
Occupancy CA City Attorney
FI:Final inspection AMWC.Water Comp.
F0:Final Occupancy
review and approval by the City Engineer
37 Submit calculations to support the design of any structures or pipes. GP,BP CE
Closed conduits shall be designed to convey the 10-year flow with
gravity flow the 25-year flow with head, and provide safe
conveyance for the 100-year overflow
38. Show the method of dispersal at all pipe outlets. Include GP,BP CE
specifications for size&type.
39 Concentrated drainage from off-site areas shall be conveyed across GP, BP CE
the project site in drainage easements.Acquire drainage easements
where needed Drainage shall cross lot lines only where a drainage
easement has been provided. If drainage easement cannot be
obtained the storm water release must follow the exact historic path,
rate and velocity as prior to the subdivision.
40 Applicant shall submit erosion control plans and a Stone Water GP BP CE
Pollution Prevention Plan (SWPPP). A SWPPP is required where
greater than 1 acre is disturbed by construction of the project. The
Regional Water Quality Control Board shall approve the SWPPP
41 All public improvements shall be constructed in conformance with GP BP CE
the City of Atascadero Engineering Department Standard
Specifications and Drawings or as directed by the City Engineer
42. The on-site residential streets shall be improved consistent with the GP, BP CE
Tentative Tract Map
43 Off-site streets shall be improved consistent with the Tentative Tract GP BP CE
Map
44 Alignment of frontage improvements shall be approved by the City GP BP CE
Engineer
45 A mechanism to provide for the funding of maintenance for lighting, GP BP CE
street improvements, special paving surfaces, sewer storm drain,
common area landscape, open space, and/or hardscape shall be
provided
46 All utilities shall be undergrounded on project frontage GP BP CE
AMWC Conditions
15 Before issuance of building permits the applicant shall obtain a
'Will Serve letter from AMWC for the newly created lots within the
subdivision.
err+
City of Atascadero
Resolution No 2006-091
Page 11 of 16
Conditions of Approval/ Timing Responsibility Mitigation
Mitigation Monitoring Program /Monitoring Measure
GP*Gradrg Permit PS.Planning Services
BP Building Permit BS.Building Services
2865 Ferrocarril Road SIP'Subdivision FD:FireDeparfirent
Improvement Plans PD:Police Depaitmnt
Vesting Tentative Tract Map FM:Final Map CE:Cry Engineu
TO:Temporary WW:Wastewater
TTM 2004-0059 Occupancy CACity Attorney
FI:Final inspection AMWC:Water Comp.
FOr.Anal Occupancy
Mitigation Measures
Mitigation Measure 1.c.1 Individual units shall be painted with earth BP PS
toned colors.All materials shall be high quality and designed to blend
with the surrounding environment.
Mitigation Measure 1.c.2: An open space easement and a BP PS
pedestrian/equestrian trail shall be incorporated into the design along
the western edge of the project to maintain the rural visual character of
the project site.
Mitigation Measure 1.d.1 All lighting shall be residential in nature.A BP PS
maximum of 1 common light post may be permitted at the terminus of
the driveway for safety Any such light post and fixture shall be full cut-
off and a maximum of 12-feet in height.The light shall be placed on a
motion sensor and shall not be left on past 10pm.
Mitigation Measure 3.b.1 The project shall be conditioned to comply BP PS
with all applicable District regulations pertaining to the control of
fugitive dust(PM-10)as contained in sections 6 3 6 4 and 6.5 of the
April 2003 Air Quality Handbook.
■ Asbestos has been identified by the state Air Resources Board as
a toxic air contaminant. Serpentine and ultramafic rocks are very
common in the state and may contain naturally occurring
asbestos. Under the State Air Resources Board Air Toxics
Control Measure(ATCM)for Construction, Grading Quarrying
and Surface Mining Operations prior to any grading activities at
the site the project proponent shall ensure that a geologic
evaluation is conducted to determine if naturally occurring
asbestos is present within the area that will be disturbed If
Naturally Occurring Asbestos (NOA)is found at the site the
applicant must comply with all requirements outlined in the
Asbestos ATCM for Construction Grading Quarrying and
Surface Mining Operations. If NOA is not present, an exemption
request must be filed with the District. If NOA is found at the site
the applicant must comply with all requirements outlined in the
Asbestos ATCM. This may include development of an Asbestos
Dust Mitigation Plan and an Asbestos Health and Safety Program
for approval by the APCD Should Naturally Occurring Asbestos
be identified within the area of construction and the worked area
will be less than or equal to one acre then the dust control
measures identified below are required If the disturbed area is
greater than one acre additional requirements may include but
are not limited to 1)an Asbestos Dust Mitigation Plan which must
be approved by the District before construction begins, and 2)an
Asbestos Health and Safety Program will also be required for
some projects
• Dust Control Measures for Construction and Grading Operation
fir+ Projects One Acre or Less No person shall engage in any
construction or grading operation on property where the area to
City of Atascadero
Resolution No 2006-091
Page 12 of 16
Conditions of Approval/ Timing Responsibility Mitigation
Mitigation Monitoring Program /Monitoring Measure
GP'Grading Permit PS.Planning Services
BP'Budding Permit BS.Building Services
2865 Ferrocarril Road SIP Subdivision FD:Fire Department
Improvement Plans PD:Police Department
Vesting Tentative Tract Map Rvt:Final Map CE.City Engineer
TO:Temporary WW Wastewater
TTM 20040059 Occupancy cn City Attorney
FI:Final inspection AMWC:Water Comp.
FO:Final Occupancy
be disturbed is one(1 0)acre or less unless all of the following
dust mitigation measures are initiated at the start and maintained
throughout the duration of the construction or grading activity-
1
ctivity1 Construction vehicle speed at the work site must be limited to
fifteen (15)miles per hour or less-
2. Prior to any ground disturbance sufficient water must be
applied to the area to be disturbed to prevent visible
emissions from crossing the property line,
3 Areas to be graded or excavated must be kept adequately
wetted to prevent visible emissions from crossing the property
line
4 Storage piles must be kept adequately wetted, treated with a
chemical dust suppressant, or covered when material is not
being added to or removed from the pile,
5 Equipment must be washed down before moving from the
property onto a paved public road- and
6 Visible track-out on the paved public road must be cleaned
using wet sweeping or a HEPA filter equipped vacuum device
within twenty-four(24)hours.
Mitigation Measure 4.b.1 Prior to issuance of grading/building BP BS
permits the small riparian scrub area at the northwest corner and
freshwater marsh area at the southern tip of the property shall be
fenced with protective fencing at the limit of the area plus 5 feet.
There shall be no construction activity or storage of materials or
vehicles in these areas. All sanitation facilities shall be placed outside
these areas and outside the dripline of any native tree.
Mitigation Measure 4.b.2. The developer shall contract with a qualified BP PS
biologist to perform surveys for both the vernal pool fairy shrimp and
botanical resources prior to issuance of any site disturbance permits.
The surveys are to be completed no more than three(3)weeks prior to
the issuance of grading/building permits or other site disturbance.
Mitigation Measure 4.d.1 In accordance with the Migratory Bird GP PS
Treaty Act of 1918 the applicant shall contact the United States Fish
and Wildlife Service(USFWS)for direction. The applicant shall
provide copies of all correspondence with USFWS prior to issuance of
grading/building permits and shall incorporate all recommended
mitigation measures into the project design.
BP PS
Mitigation Measure 4.e.1 The Grading Plan shall identify tree
protection fencing around the dripline or as recommended by the
project arborist,of each existing on-site or off-site native tree.
City of Atascadero
Resolution No 2006-091
Page 13 of 16
Conditions of Approval/ Timing Responsibility Mitigation
Mitigation Monitoring Program /Monitoring Measure
GP'Grading Permit PS.Planning Services
Building Permit
2865 Ferrocarril Road SR Subdivision FD:Fire Building
Improvement Plans PD:Police Department
Vesting Tentative Tract Map FM:Final Map CE:City Engineer
TC:Temporary WW:Wastewater
TTM 20040059 Occupancy CA:City A&M
FI:Final inspection AMWC:Water Comp.
F0:Final Occupancy
At no time shall tree roots be ripped with construction
equipment. If any roots,over 2 inches are accidentally ripped
they shall be cut perpendicular to the direction of growth with a
handsaw and no tree wound paint shall be applied.
Mitigation Measure 4.e.2: Grading and excavation and grading work GP PS
shall be consistent with the City of Atascadero Tree Ordinance
Special precautions when working around native trees include.
1 All existing trees outside of the limits of work shall remain.
2. Earthwork shall not exceed the limits of the project area.
3. Low branches in danger of being torn from trees shall be pruned
prior to any heavy equipment work being done
4 Vehicles and stockpiled material and sanitation facilities shall be
stored outside the dripline of all native trees.
5 All trees within the area of work shall be fenced for protection with
4-foot chain link, snow or safety fencing placed per the approved
tree protection plan Tree protection fencing shall be in place prior
to any site excavation or grading. Fencing shall remain in place
until completion of all construction activities
6 Any roots that are encountered during excavation shall be clean
cut by hand and sealed with an approved tree seal
Mitigation Measure 4.e.3 The developer shall contract with a certified GP PS
arborist during all phases of project implementation. The certified
arborists shall be responsible for monitoring the project during all
phases of construction through project completion as follows.
1 A written agreement between the arborist and the developer
outlining an arborist monitoring schedule for each construction
phase through final inspection shall be submitted to and approved
by planning staff prior to the issuance of building/grading permits
2. Arborist shall schedule a pre-construction meeting with
engineering/planning staff grading equipment operators, project
superintendent to review the project conditions and requirements
prior to any grubbing or earth work for any portion of the project
site. All tree protection fencing and trunk protection shall be
installed for inspection during the meeting Tree protection
fencing shall be installed at the line of encroachment into the
tree s root zone area.
2. As specified by the arborist report and City staff-
• Prune all trees in active development areas to be saved for
structural strength and crown cleaning by a licensed and
City of Atascadero
Resolution No 2006-091
Page 14 of 16
Conditions of Approval I Timing Responsibility Mitigation
Mitigation Monitoring Program ]Monitoring Measure
GP Grading P97M PS.Planning Services
BP Building Permit BS:Building Services
2865 Ferrocarril Road SIP*Subdivision FD:FireDepar6nent
Inpronernent Plans PD:Police Department
Vesting Tentative Tract Map FM:Final Map CE:Gay Engineer
TQ Temporary WW:Wastewater
TTM 2004-0059 Occupancy ca city Atlomey
FI:Final inspection AMWC:Water C T.
F6 Final Occupancy
certified arborist.
• Remove all debris and spoils from the lot cleaning and tree
pruning
• In locations where paving is to occur within the tree canopy
grub only and do not grade nor compact. Install porous pavers
over a three-inch bed of 3/.inch granite covered with one-inch
pea gravel for screeding. If curbs are required use pegged
curbs to secure the porous pavers. Pegged curbs are
reinforced six to eight curbs poured at grade with a one-foot by
one-foot pothole every four to six linear feet.
■ All trenching or grading within the protected root zone area,
outside of the tree protection fence shall require hand
trenching or preserve and protect roots that are larger than 2
inches in diameter
• No grading or trenching is allowed within the fenced protected
area.
• Any roots that are 4 inches in diameter or larger are not to be
cut until inspected and approved by the on-site arborist.
• Pathways driveways and parking areas that run under tree
canopies shall be made out of porous pavers to allow oxygen
and moisture to reach root systems.
• Utilities such as water gas power cable storm drainage
telephone and sewer should be directed away from under
canopies and the critical root zone(CRZ)of the trees. If this is
not possible or feasible then they should be bored under the
tree at a minimum depth of 3 feet. Consult with the Arborist for
further direction if necessary
■ Where a building is placed within the canopy of a tree the
foundation or walls should be designed so that it bridges
across any root system.
• Any foundation or other structure that encroaches within the
dripline of trees shall be dug by hand or a small piece of
equipment.
4 Upon project completion and prior to final occupancy a final
status report shall be prepared by the project arborist
certifying that the tree protection plan was implemented the
trees designated for protection were protected during
construction, and the construction-related tree protection
measures are no longer required for tree protection
Mitigation Measure 5.b.1 The project architect shall prepare GP PS
development plans that avoid the archaeological site. In the event that
testing reveals archaeological deposits with integrity and significant
scientific values the project plan should be designed to minimize
disturbance of site soils and thereby protect the resources. If testing
shows the deposits to be shallow depleted and generally insignificant,
then plans need not be prepared to avoid impacts.
Mitigation Measure 5.b.2: Prior to issuance of grading/building GP PS
ermits,the developer shall have a Phase II archaeological
City of Atascadero
Resolution No 2006-091
Page 15 of 16
Conditions of Approval/ Timing Responsibility Mitigation
Mitigation Monitoring Program /Monitoring Measure
GR Grading Pund PS.Planning Services
BPBuilding Pemrt BS:Building Services
2865 Ferrocarril Road SIP Subdivision FD:FriaDvartmenl
Improvernent Plans PD:Police Department
Vesting Tentative Tract Map FM:Final Map CE.City Engineer
TO:Temporary WW Wastewater
TTM 20040059 Occupancy CA CityAtlomey
FI:Final inspection AMWC:Water Comp.
F0:Final Occupancy
investigation to determine the dimensions of the archaeological
deposits,their physical characteristics and material contents.
Different areas should be systematically sampled and all recovered
materials should be thoroughly processed identified and analyzed
Before Phase II sampling begins,the project archaeologist should
prepare a comprehensive research design which includes a sampling
strategy and an analytical framework.
Mitigation Measure 5.b.3. The data from the Phase II sampling shall GP PS
be evaluated and using the California Environmental Quality Act
guidelines a determination shall be made regarding classification of
the site as an 'important cultural resource."
Mitigation Measure 5.b.4 If the Phase II testing shows that significant GP PS
resources do exist then a Phase III mitigation and management plan
shall be prepared to deal with expected impacts The project
archaeologist shall aide in developing a mitigation plan with the goal of
preserving the archaeological resource.
Mitigation Measure 5.b.5 The Developer shall contact and work GP PS
closely with both the Chumash and the Salianian Tribes during any
11rr Phase II Cultural Resource Assessment to insure that any cultural
resources are preserved
Mitigation Measure 5.d.1 In the event of the accidental discovery or GP CE
recognition of any human remains,the following steps shall be taken--
There shall be no further excavation or disturbance of the site or any
nearby area reasonably suspected to overlie adjacent human remains
until the coroner of the county in which the remains are discovered has
been contacted to determine that no investigation of the cause of
death is required and to determine if the remains are of Native
American heritage. If the remains are of Native American Heritage
the coroner shall contact the Native American Heritage Commission
within 24 hours.
Mitigation Measure 6.a.c.1 Prior to issuance of grading/building GP BS
permits,the developer shall submit a geotechnical investigation that
addresses earthquake and liquefaction potential. Based on this report,
all recommendations for building and site design shall be
implemented
Mitigation Measure 8e.f.1 A Stormwater Pollution Prevention Plan BP CE
(SWPPP)/Erosion Control Plan shall be submitted and approved by
the City Engineer prior to the issuance of the building permit. The plan
shall include storm water measures for the operation and maintenance
of the project for the review and approval of the City Engineer The
Building Permit application plans shall identify Best Management
Practices (BMPs) appropriate to the uses conducted on site that
effectively prohibit the entry of pollutants into storm water runoff
City of Atascadero
Resolution No 2006-091
Page 16 of 16
Conditions of Approval/ Timing Responsibility Mitigation
Mitigation Monitoring Program /Monitoring Measure
GP Grading Permit PS.Planning Services
BP'Building Permt BS:Building Services
2865 Ferrocarril Road SIP Subdivision FD:Fire Department
Improvement Plans PD:Police Department
Vesting Tentative Tract Map FM:Final Map CE.City Engineer
TTM 20040059 �Temporary
q CA City Attorney
FI:Final inspection AMWC.Water Comp.
F0:Final Occupancy
Mitigation Measure 8.e.f.2: The developer is responsible for ensuring BP BS,PS,CE
that all contractors are aware of all storm water quality measures and
that such measures are implemented Failure to comply with the
approved construction Best Management Practices will result in the
issuance of correction notices citations,or stop work orders.
Mitigation Measure 11.d All construction activities shall comply with Ongoing BS/PS
the City of Atascadero Noise Ordinance for hours of operation
Mitigation Measure 13.a.1 The Developer shall insure that structures BP CE
and/or septic systems are not built within the Atascadero Mutual Water
Company easement, nor will development of the project interfere with
maintenance or operation of any existing water lines.
�1rrr'