Loading...
HomeMy WebLinkAbout5._Scoping_DocumentsFIRESTATION#1–VE/FINALCONSTRUCTIONSCOPINGDOCUMENT AtascaderoFireHeadquartersFacilityislocatedat6005LewisAvenue,intheCityofAtascadero,CAand isthecurrentsiteofAtascaderoFireStation1thatwillbedemolished. TheprojectwillconsistofthenewFireStation1facilityasindicatedontheattachedarchitecturaldrawings byLDAPartners(LDA),Plumbing&HVACdrawings&scopesviaFourC’s/BonesoPlumbing& Mechanical,andtheelectricalscopeanddrawingsviaThomaElectric.Thesevaryfromtheoriginal bridgingdocumentsanddocumenttheValueEngineeringchangesdiscussedandincorporatedtoobtainthe currentcontractamountfortheproject.Includedistheupdatedsiteimprovementscopeandtheedits directingrevisingitemsandaddingthemtotheOwnerprovidedFF&Epackage. Theproposedauxiliarybuildingwasremovedfromthescope.Thiswasaresultoftheapparatusbayssizing andquantitiesatbothFireStations.Also,thefitnessroomisincludedinthemainbuilding. On-siteimprovementswillincludemodificationstotheexistingutilityinfrastructure,parkinglotsand driveways,acoveredtrashenclosure,newfencingandgatestoprovidesiteaccessandsecurity.Allas indicatedontheattacheddrawingsfromLDA. Off-siteimprovementsincludepublicparking,sidewalks,andlandscaping. ThenorthwestcornerofthesitesharesahistoricmonumentwiththeadjacentDistrictSchoolproperty. Shallbeprotectedandwillremainunchangedunlessbudgetallows. Thefirestationisdesignedasatwo-storybuildingandwillbedesignedtomeettherequirementsofthe EssentialServicesAct.TherearenoCOPSrequirementsforthisproject.TheexistingFireStationwillbe demolished.Thenewbuildingwillincludefireadministrativeoffices,firefighterworkspaces,livingand livingquarters,decontaminationarea,turnoutspace,alobby,public&privaterestrooms,meetingspaces, trainingclassroom,emergencyoperationcenter,athree-baydrivethroughapparatusbayforstackedparking (for5vehicles),afitnessroomandassociatedsupportspaces. Thefiredepartmentintendstosalvageandre-usespecificprojectcomponentsasnotedbelow: • ExistingMetalEnclosure:TheCitydesirestosalvageandre-usetheexistingmetalenclosureatthe temporaryfacilities(temporaryfacilitiesarenotapartofthiscontract/project). • ExistingMetalCarport:TheCitydesirestosalvageandre-usetheexistingmetalcarport.DBEto coordinatewiththeCityteamonwherethisitemistobedelivered. • ExistingAirFillStation:TheexistingBauercompressorandairfillingstationtobesalvagedand re-installedinthenewfirestation.BauerCompressor6000PSI,4Bottlefillstation,Model–P5 Securus,60HZ,38AMP,16CFM,15HP,Manufactured7/03 • TheexistingemergencygeneratoristobesalvagedandprovidedtotheCity. • Contractortosalvageexistingflagpolemonumentplaqueforre-useandcoordinationnewlocation, Allsalvageditemsnotscheduledtobere-usedwillbedeliveredtoalocallocationbyF&Hascoordinated. SCOPEITEMSBYSPECIFICATION F&HConstruction’s(F&H)ScopingDocumentsprovidedF&H,LDAPartners(LDA),BonesoPlumbing andMechanical(Boneso),ThomaElectric(Thoma),andassociatedconsultantsbyshallgoverntheproject Scoping Documents scope.ThefollowingscopesidentifiedintheRFP’sDetailedSpaceUseRequirementssectionhavebeen modifiedandtheoriginalRFPscopeisnotapplicabletothesescopes.Scopeforthefollowingitemsis asdefinedinthecontractor'sprovideddocuments:Security,FloorLevelLocation,Isolation,Floor Finish,WallFinish,CeilingFinish,CeilingHeight,Sound/AcousticTreatment,Casework,Casework Type,Countertops,SpecialRequirements,andMechanicalandElectricalRequirements. DEMOLITION •Thisprojectwillconsistofthedemolitionoftheexistingfirestation,outbuildings,andallon-site andoff-siteimprovementsasneededfortheproject. BUILDINGCONCRETE •Standard Concrete foundations and slabs will be designed by the structural engineer & in accordancewiththesoilsreport, •ForclarificationonsealedconcreteareasisreferredtoontheLDAscopedrawings, BRICKMASONRY •StandardColor,SplitFaceCMUmasonrywillbeusedatthetrashenclosure, •Exteriorwallsthinbrick,asindicatedontheLDAScopingDrawingsshallbethinbricksimilaror equaltoa“MountainRose,ModularThinBrick(1/2)”asmanufacturedbyH.C.Muddox, STRUCTURALFRAMING •Dependingonfinalstructuraldesigntheprojectwillbeeitherlightgaugemetalframingorwood framingoramixturethereof, INTERIORARCHITECTURALWOODWORKINGANDCASEWORK •CabinetstobeincludedareasindicatedandshownontheLDAscopedrawingsnotedasfollows: o Reception/lobbydeskshallbeanFF&Eitemandnotincludedinthiscontract, o Standardplasticlaminatecabinets(Lowers&Uppers)-reducedduringvalueengineering, o Restroomsolidsurfacecountertops, o Pass-throughstainless-steelcountertopatlobby, o Kitchencabinetswillincludeplasticlaminatedcabinetswithsolidsurfacecountertops, o Laundrycabinetstobeplasticlaminatewithsolidsurfacecountertops, o Decontaminationareacabinettobestainlesssteel, o Bunkroomcabinets,wardrobelockers,desks,bunksandbunkfurnitureshallbeanFF&E itemandnotincludedinthecontract, o Thebalanceofthestorageshelving,shopcabinetsandmisc.cabinetsshallbeanFF&E itemandnotincludedinthecontract, WATERPROOFING,INSULATION,FIRESTOPING&SEALANTS •Waterproofingwillbeappliediforasnecessaryatthebuildingretainingwallifdesignrequires, •Newbuildingtoincludeinsulationasrequiredtomeettitle24, •Newbuildingtoincludeinsulationinallinteriorwallstoreducenoise, •Firestoppingwillbeincludedifandasnecessarytomeetthefireratingrequirements, •Caulkingandsealantswillbeincludedasnecessaryforawatertightbuilding, ROOFING •FlatroofingareastobePVCroofingmembranewitha30-yearwarranty, •Roofingflashing&sheetmetaltobestandardandmeettheroofingmanufacturersstandards, DOORS,FRAMES,WINDOWS&HARDWARE •Doors,frames&hardwareareasnotedontheLDAscopedrawings. •Thedoorsandframeswillbeeitherhollowmetal,knock-downorwoodtomeetanyCityStandards, •TheapparatusbaydoorsshallbepertheoriginalRFPrequirements, •MirrorsattheexerciseroomwillbeanFF&Eitemandnotpartofthiscontract, •Thewindowswillbestandardstyle,non-ballisticrated.Anyballisticsratingdoesnotapplyvia valueengineering, •Theglassstorefrontdoorstobestandarddoors, •Transactionwindowtobeastandardwindowwithacommunicationport&passthroughslot, •Skylights&tubularskylightsweredeletedduringthevalueengineeringprocess, FINISHES •Gypsumboardwallsandceilingstobefinishedtoalevel4finish,primedandpaintedatexposed, •Theapparatusbayshallbeopentotheroofstructureabove, •Cementboardwillbeusedonallrestroomwalls, •ExteriorwallsandsoffitstobeportlandcementplasterasindicatedontheLDAscopedrawings, •TilingatinteriorasindicatedontheLDAscopingdrawingsandtobe4x4Dal-tileatfloors&at kitchenbacksplashand2x2Dal-tileatwallsorequivalentandcoordinatedduringdesign, •Resilientflooring&rubberbaseisindicatedonLDAscopingdrawings, •Resinousflooring&baseisindicatedonLDAscopingdrawings, •FRPwallstobeasindicatedonLDAscopingdrawings, •AcousticceilingtilestobeasindicatedontheLDAscopingdrawings, MISCELLANEOUSITEMS •SignageatinteriorandexteriortobeasrequiredforADA&coderequiredsignageforpermitting, •ExterioraluminumletteringtobeasindicatedonLDAscopingdrawings, •ToiletaccessoriestobeanFF&Eitemandnotincludedinthiscontractexceptfortheshowerseat asthisisarequiredADAitemforpermitting, •Fireextinguishers&cabinetswillbeasrequiredforpermitandcode, •Metallockersinclude25standard,24turnoutandbenchesasshownontheLDAscopingdrawings, •NewflagpoleswillbeinstalledasindicatedontheLDAscopingdrawings, •AllkitchenandlaundryapplianceswillbefurnishedbytheCity&installedbyContractor, •WindowshadeswillbeanFF&Eitemandnotpartofthiscontract, FIREPROTECTION,PLUMBING&HVAC •FiresprinklerandfirelinesasdesignedbyS&MFireProtectiontomeetcode, •PlumbingsystemtobeasindicatedontheBoneso’sScopingDocuments, •HVACsystemtobeasindicatedontheBoneso’sScopingDocuments, ELECTRICAL •ElectricalsystemstobeasindicatedontheThoma’sScopingDocuments, SITEDEVELOPMENT •ThedevelopmentofsiteisasindicatedontheLDAscopingdocuments, •HandrailatrampwillbeinstalledasrequiredbyADAaccessibilityrequirements, •Fencing,facingthestreetfront,shallbeornamentalmetalfencingandgates, •Fencingatpropertylinebeyondthefrontfencingtobe6’chainlinkwithfabricorvinylslats, •Landscapingtobelimitedtothedisturbedsitearearequiredforthedevelopment, •StripingtobelimitedtothedevelopmentofthesiteasnotedintheLDAscopedrawings, •Fourbikeracksareincludedtomeetcode, •SiteUtilitiesincludedomesticwaterline,fireline,connectionnearbuildingforexistingsewer line,stormdrain,andgasline(metertobuilding)isincludedasnecessaryfromeitherexistingor fromutilityconnectionatcitystreetconnection, •AllpermitsandutilityconnectionfeesaretobepaidbytheCity, GENERALCONDITIONSANDMISCELLANEOUSPROJECTITEMS •F&H’sreducedgeneralconditionsandsupervisiondonotincludeprovisionsforafull-time schedulertomeetschedulecostloading,resourceloading,andcostcorrelationrequirements(per SpecificationSection013200),afull-timeonsiteQA/QCmanager(perSpecificationSection01 4523),afull-timesafetymanager(perSpecificationSection015600),orafull-time commissioningcoordinator(perSpecificationSection019100).F&HConstructionaffirmsthat thegeneralconditionsandsupervisionprovidedaresufficienttomeettheproject’srequirements. Tosupportschedulingobligations,theContractorwillprovideathird-partyschedulerresponsible forprovidingweeklyP6scheduleupdatesandmonthlynarrativesincompliancewiththe progressschedulespecificationsexcludingcostloadingandresourceloading.TheContractor shallimplementaQA/QCplan,whichwillbemanagedbytheonsitesuperintendentwith oversightfromtheoffsitegeneralsuperintendent.Additionally,afull-timeprojectengineershall bedesignatedtocoordinatecommissioningactivitieswiththeOwner’sCommissioningAgent, •PermitsandutilityconnectionfeesaretobepaidbytheCity, •F&HincludesSWPPPplans,oversiteandimplementation, •Revised&NegotiatedLanguageforEscalation: o ContractorandOwnerrecognizethatOwnerhasalimitedbudgetof$31,072,318andthat there is the potential for material cost escalation should various events occur, both anticipatedandunanticipated,thatareoutsidethereasonablecontrolofbothparties.As necessitatedbysuchevents,OwnerandContractoragreetoworkingoodfaithtoidentify mutuallyacceptablechangestothescopingdocumentsincludinguseofalternativebut functionally-equivalentmaterials,manufacturers,equipmentorprocurementstrategies. o TheContractorshallprovidebudgetassessmentsatthecompletionofSchematicDesign andDesignDevelopmentphasestotheCity.Theseshallincludeanevaluationofpotential costescalationsanddesignsavings.TheContractorshallconductbudgetreviewswiththe Cityateachphase,andasotherwisedeemedreasonablyappropriatebyOwner,toidentify and mitigate cost escalation risks associated with materials, equipment and other procurement. o Contractoragreestotakecommerciallyreasonablemeasurestomitigateoravoidcost escalations, including preordering materials or systems, prioritizing long lead times, identifying alternative butfunctionally-equivalentmaterials,equipment,manufacturers and/orsystems,andtootherwisecooperatewithOwnertocometoamutuallyagreeable resolutionthatallowsthecompletionoftheprojectwithintheOwner’sbudget.Owner agrees to consider alternative but functionally-equivalent materials, equipment, manufacturersand/orsystems,toexpediteprocessingofsubmittalsforlongleadtime items,toreimburseContractorforpreorderedmaterialsorsystemsorderedearlywith Owner’sconsent,andtootherwisecooperatewiththeContractortocometoamutually agreeableresolutionthatallowsthecompletionoftheprojectwithintheOwner’sbudget. LEWIS AVETRAFFIC WAYLEWIS AVETRAFFIC WAY12345 67891011121314151617181920SCALE: 1/16" = 1'-0"TRANS.GEN.TRASH11 1213 14NOTE:NO WORK TO EXISTING FOUNTAIN0'8'16'32'64'SCALE: 1/16" = 1'-0"0'8'16'32'64'0'8'16'32'64'SCALE: 1/16" = 1'-0"ATASCADERO PUBLIC SAFETY FACILITY - FIRE STATION 1SITE PLAN3/6/2025TOS REVIEW:Please change gate torolling and eliminatingswing gatesTOS REVIEW:Please rotate the trash enclosure. City Planning to review if screenwall is needed to hide theemergency generator. Please confirm if there is a back-uppropane fuel tank for the generatorif required to meet the essentialservices actTOS REVIEW:Please change gate to rolling andeliminating swing gatesTOS REVIEW:City FD has requested that a"KEEP CLEAR" zone belabeled and striped CIRC.CIRC.TOTAL BUILDING AREA: 13,491 S.F.0'4'8'16'32'SCALE: 1/8" = 1'-0"CHARGEWATCHB.C. &CAPT.OFFICEFIRECHIEFMEDICALSTOR.QUIETR.R.DEP.CHIEFOPSCHIEFELEV.FIREMARSHALFIREINSP.ADMIN.LOBBYEXEC.BREAKOUTROOMSERVERE.O.C.STOR.ELEC.WORKBREAKPATIOAPP.BAYMECH.HOSES.C.B.A.SHOPEXERC.DECON.ELEV.EQUIP.WOMENMENTRAININGCHARGEIDFSTOR.R.R.JAN.STOR.TURNOUT1TURNOUT2PATIOSTORAGETOTAL BUILDING AREA: 2,968 S.F.0'4'8'16'32'SCALE: 1/8" = 1'-0"BEDROOM1BEDROOM2BEDROOM3BEDROOM4BEDROOM6BEDROOM5R.R. 1R.R. 2 R.R. 3 ELEV.LAUND.JAN./STOR.DAYROOMOUTDOORPATIOATASCADERO PUBLIC SAFETY FACILITY - FIRE STATION 1FLOOR PLANS3/6/2025ALL FF&E ARE FURNISHED AND INSTALLED BY OWNERTOS COMMENT: Please showlocation of mop sinkTOS REVIEW:Do not need doors. Framedopening to FD's preferenceTOS REVIEW:Hose is an alcove. Do not needdoors or wall at hallway.Framed opening to FD'spreferenceshowextractorverify 20' min for clear height in app baysTOS COMMENT: Contractor to confirm front app bay door type. Opening speed and low maintenance are the twoprioritiesTOS COMMENT:HERE IS THE LINK TO THE HORMANN ROLLUP SPEED DOORS AS AN ALTERNATIVE TOTHE BIFOLD:https://www.hormann.us/high-performance/rigid-doors/speed-guardian-5000-lp-42/TOS COMMENT: Please consider adding door,so personnel so not have tore-enter hot zone after deconTOS COMMENT: Only 24 lockersare shown. Program requires 26.Contractor to confirm& COMPTOS COMMENT: Architect to confirm that NFPArequirements for turnout room can be metwith without doors separating the turnoutspaceTOS COMMENT: Needs space for rolling tool chestand full height haz-mat cabinetTOS REVIEW: Please confirm that access to allpanels on the (e) bauer compressorcan be achieved with placementTOS COMMENT: Missing freestanding two compartment clean upsink with drainboards and hazmat bins in DECONTOS COMMENT: There is nocoffee station space shownTOS COMMENT:Mezzanine storage has been moved to theground floor. Space will need to beconditioned for storing PPE.Please provide a space for yard equipmentstorage.TOS COMMENT: seats fewer people than programcalls for (10)TOS COMMENT: Please confirmthat (5) Full height lockers forcommand staff are includedTOS COMMENT: Provide 2 doorsinto this space. Regular users willbe the Admin folksTOS COMMENT: Please consider moving these doorsapart, so that casework and displays canbe in the middle. This seems like theonly space that will be able to fit anythingTOS COMMENT: Pleaseconsider and provide access tothe hallway and pathway to thelaundry for decon of clothingfrom this space.TOS COMMENT: double occupancy bunk roomrequires space for 6 wardrobe lockers. Pleaseconfirm.TOS COMMENT: Architect to reviewlocation of these stairs for exitingand connection to the app bay forturnout time efficienciesTOS COMMENT: These could becombined into one spaceTOS COMMENT: Please showpublic counter and windowTOS COMMENT: Please show location for turnout washer with sumpdrain.TOS COMMENT: Pleaseconsider roll up door hereTOS COMMENT: Please show location of thehygiene lockers and benches shownTOS COMMENT: Architect to review location of these stairs forexiting and connection to the app bay for turnout time efficienciesTOS COMMENT: FF&E items should be shown all the same. There is casework that is still shown in contractgraphically and does not align with narrative or thethe City's FF&E Lists. Please update so we can confirm and finalize theCity's FF&E listsTOS COMMENT: Please consider moving these doors toprovide more wall space and access streetfor maintenance in the electrical roomTOS COMMENT: Eliminate dooror use for turnout washer accessto rear for maintenanceTOS COMMENT: Missing location for ice machine. Prefer aclean location. Not in the app bays.TOS COMMENT: Please show freestandingstainless steel clean-up sink withdrainboards and plumbingfixtures per program. OPEN TO ABOVEOPEN TO ABOVE0'4'8'16'32'OPEN TO CLG.ABOVEOPEN TO CLG.ABOVESCALE: 1/8" = 1'-0"9'-0"9'-0"9'-0"9'-0"9'-0"9'-0"9'-0"9'-0"9'-0"9'-0"9'-0"9'-0"9'-0"9'-0"9'-0"9'-0"9'-0"9'-0"9'-0"9'-0"9'-0"9'-0"9'-0"9'-0"9'-0"9'-0"9'-0"CLG. HT. VARIES9'-0"9'-0"9'-0"9'-0"9'-0"9'-0"9'-0"MECH.HOSE TURNOUT1TURNOUT2S.C.B.A.SHOPEXERC.APP.BAYWATCHB.C. &CAPT.OFFICEFIRECHIEFQUIETR.R. IDFELEV.ELEV.EQUIP.STOR.JAN.DECON.MEDICALSTOR.R.R.DEP.CHIEFOPSCHIEFFIREMARSHALADMIN.FIREINSP.LOBBYEXEC.BREAKOUTROOMSERVERSTOR.E.O.C.STOR.ELEC.BREAKWORKTRAININGMENWOMEN9'-0"9'-0"9'-0"9'-0"9'-0"OPEN TO ABOVE0'4'8'16'32'SCALE: 1/8" = 1'-0"9'-0"9'-0"9'-0"9'-0"9'-0"9'-0"9'-0"9'-0"9'-0"9'-0"9'-0"BEDROOM1BEDROOM2BEDROOM3BEDROOM4BEDROOM6BEDROOM5R.R. 1R.R. 2 R.R. 39'-0"LAUND.JAN./STOR.DAYROOMELEV.OUTDOORPATIO13'-0"OPEN TO ABOVENO CEILING24" x 48" TEGULAR ACOUSTICAL CEILING PANEL5/8" TYPE "X" GYPSUM BOARD, LEVEL 4, PRIME & PAINTLEGENDATASCADERO PUBLIC SAFETY FACILITY - FIRE STATION 1REFLECTED CEILING PLANS3/6/2025TOS REVIEW: City IT prefers acoustical ceilings in the IDF and IT spacesTOS REVIEW: City prefers gyp board ceilingTOS COMMENT: Two types of acoustical ceiling tile sizes. Cityprefers only one size be used.TOS REVIEW: City prefers gyp board ceiling TURNOUT1B.C. &CAPT.OFFICEDEP.CHIEFR.R.APP.BAYTRAININGQUIETWATCHS.C.B.A.FIREMARSHALMEDICALSTOR.CIRC.SCALE: 1/8" = 1'-0"TURNOUT2MECH.HOSESHOPEXERC.FIRECHIEFOPSCHIEFFIREINSP.ADMIN.LOBBYWOMENMENEXEC.BREAKOUTROOMSERVERSTOR.E.O.C.STOR.ELEC.BREAKWORKDECON.R.R. IDF ELEV.ELEV.EQUIP.STOR.JAN.STORAGE0'4'8'16'32'SCALE: 1/8" = 1'-0"BEDROOM1BEDROOM2BEDROOM3BEDROOM4BEDROOM6BEDROOM5LAUND.JAN./STOR.DAYROOMR.R. 1R.R. 2 R.R. 3 ELEV.0'4'8'16'32'OUTDOORPATIOFINISH LEGENDSEALED CONCRETERESILIENT FLOORINGCARPET TILERUBBER FLOORINGCERAMIC FLOOR TILESTATIC DISSIPATIVE TILEEPOXYATASCADERO PUBLIC SAFETY FACILITY - FIRE STATION 1FLOOR FINISHES PLANS3/6/2025TOS REVIEW: Sealed concreteTOS REVIEW: There should be one flooring material throughout the new building. FDpreference is polished concrete for easy maintenance. Second Floor - please use LVT in all spaces except at restroomsEliminate carpet in Lobby. Use carpet only in the training room,breakout room, and executive conference room.Use polished concrete on the ground floor. The ceramic tile area maybe reduced to the shower area in each firefighter restroomTOS REVIEW: Polished concrete, typTOS REVIEW: EpoxyTOS REVIEW: Provide decking material above theroofing membrane to protect the roofingTOS REVIEW: Rubber treads and risers at stairs,typ. CIRC.0'4'8'16'32'SCALE: 1/8" = 1'-0"CHARGEWATCHB.C. &CAPT.OFFICEFIRECHIEFMEDICALSTOR.QUIET R.R.DEP.CHIEFOPSCHIEFELEV.FIREMARSHALFIREINSP.ADMIN.LOBBYEXEC.BREAKOUTROOMSERVERE.O.C.STOR.ELEC.WORKBREAKPATIOAPP.BAYMECH.HOSES.C.B.A.SHOPEXERC.DECON.ELEV.EQUIP.WOMENMENTRAININGCHARGEIDFSTOR.R.R.JAN.STOR.TURNOUT1TURNOUT2STORAGE0'4'8'16'32'SCALE: 1/8" = 1'-0"BEDROOM1BEDROOM2BEDROOM3BEDROOM4BEDROOM6BEDROOM5R.R. 1R.R. 2 R.R. 3 ELEV.LAUND.JAN./STOR.DAYROOMOUTDOORPATIOATASCADERO PUBLIC SAFETY FACILITY - FIRE STATION 1WALL FINISHES3/6/2025TOS REVIEW: Exposed rated plywood as wall finishTOS REVIEW: FRP on walls in both these spacesTOS REVIEW: Please remove. Covered in FF&E as Cityprovided, contractor installed.TOS REVIEW: Please define height of the ceramic tile wallsTOS REVIEW: Locations do not seem to be defined on the floor plans. Please provideTOS REVIEW: Provide backsplashTOS REVIEW: Confirm height of the ceramic tile on wallsTOS REVIEW: Confirm height of the ceramic tile on wallsTOS REVIEW: FRP on walls in both these spaces LEWIS AVETRAFFIC WAYSCALE: 1/16" = 1'-0"1/4" / 12"1/4" / 12"1/4" / 12"3/4" / 12"NOTE:NO WORK TO EXISTING FOUNTAIN0'8'16'32'64'SCALE: 1/16" = 1'-0"ATASCADERO PUBLIC SAFETY FACILITY - FIRE STATION 1ROOF PLAN3/6/2025TOS REVIEW: Roof covering is required at trashenclosureTOS REVIEW: Please define roof covering materialTOS REVIEW: Recommend removing small roofareas. These are difficult tomaintainTOS REVIEW: What is the slope of these roofplanes, typ? CIRC.SCALE: 1/8" = 1'-0"CHARGEWATCHB.C. &CAPT.OFFICEFIRECHIEFMEDICALSTOR.QUIET R.R.DEP.CHIEFOPSCHIEFELEV.FIREMARSHALFIREINSP.ADMIN.LOBBYEXEC.SERVERE.O.C.STOR.ELEC.WORKBREAKPATIOAPP.BAYMECH.HOSES.C.B.A.SHOPEXERC.DECON.ELEV.EQUIP.WOMENMENTRAININGCHARGEIDFSTOR.R.R.JAN.STOR.TURNOUT1TURNOUT2STORAGEBREAKOUTROOM0'4'8'16'32'BEDROOM1BEDROOM2BEDROOM3BEDROOM4BEDROOM6BEDROOM5R.R. 1R.R. 2 R.R. 3 ELEV.LAUND.JAN./STOR.DAYROOMOUTDOORPATIO0'4'8'16'32'ATASCADERO PUBLIC SAFETY FACILITY - FIRE STATION 1PRIVACY WALL TYPES3/6/2025TOS REVIEW: Level 3TOS REVIEW: Level 2 at all restroom wallsTOS REVIEW: Level 3 at all restroom andIDF wallsTOS REVIEW: Level 3TOS REVIEW: Level 3TOS REVIEW:Provide STC ratings for all wall types ATASCADERO PUBLIC SAFETY FACILITY - FIRE STATION 1EXTERIOR ELEVATIONSFIRE STATION 13/6/20251/8" = 1'-0"A6.0061/8" = 1'-0"A6.0051/8" = 1'-0"A6.0011/8" = 1'-0"A6.002A6.003A6.004TOS REVIEW: Please provide typical materials callouts on theexterior elevations to align with the narratives FIRESTATION#2–VE/FINALCONSTRUCTIONSCOPINGDOCUMENT FireStation2islocatedat9801WestFrontRoad,intheCityofAtascadero,CA.Thesitecurrentlyserves asFireStation2fortheAtascaderoFireDepartment.Theprojectwillconsistofarenovationoftheexisting ApparatusBayanddemolishing&reconstructionoftheFireStation2facilityasindicatedontheattached architecturaldrawingsbyLDA,Plumbing&HVACdrawings&scopesviaFourC’s/BonesoPlumbing& Mechanical,andtheelectricalscopeanddrawingsviaThomaElectric.Thesevaryfromtheoriginal bridgingdocumentsanddocumenttheValueEngineeringchangesdiscussedandincorporatedtoobtainthe currentcontractamountfortheproject.Includedisthereducedsiteimprovementscopeandtheedits directingmoveditemstotheOwnerprovidedFF&Epackage. Theexistingfirestationisasingle-story(splitlevel)buildingandwillbeupdatedtomeettherequirements oftheEssentialServicesAct.TherearenoCOPSrequirementsforthisproject.Theexistingone-storyFire Stationwillincluderenovatingtheexistingapparatusdoubledrivethroughbay,andnewlyconstructed firefighterworkspaces,livingandlivingquartersandsupportspaces.Thebuildingwillinclude decontaminationareaandturnoutspacesaswellasthefirefighterlivingandsleepingspaces. Theoverallsiteareais0.93acresandincludesexistingstaffparking,undergroundutilities,andanexisting trashenclosure(toremain).Newon-siteimprovementswillincludenewhardscapingtocreateanaccessible pathfromthepublicparkingareatothemainentry. SCOPEITEMSBYSPECIFICATION F&HConstruction’s(F&H)ScopingDocumentsprovidedF&H,LDAPartners(LDA),BonesoPlumbing andMechanical(Boneso),ThomaElectric(Thoma),andassociatedconsultantsbyshallgovernthe projectscope.ThefollowingscopesidentifiedintheRFP’sDetailedSpaceUseRequirementssection havebeenmodifiedandtheoriginalRFPscopeisnotapplicabletothesescopes.Scopeforthefollowing itemsisasdefinedinthecontractor'sprovideddocuments:Security,FloorLevelLocation,Isolation, FloorFinish,WallFinish,CeilingFinish,CeilingHeight,Sound/AcousticTreatment,Casework, CaseworkType,Countertops,SpecialRequirements,andMechanicalandElectricalRequirements. DEMOLITION •Demolitionofthefirefighterworkspaces,livingquarters.Theexistingapparatusbaytoremain, •Selectivedemolitionat(e)apparatusbaystoallowforupdatedstructural,mechanical&electrical, BUILDINGCONCRETE •Standard Concrete foundations and slabs will be designed by the structural engineer & in accordancewiththesoilsreport, •Forclarificationonsealedconcrete&concretetoremainasis,refertotheLDAscopedrawings, BRICKMASONRY •AllbrickandCMUwereremovedfromtheprojectaspartofthevalueengineering, STRUCTURALFRAMING •Dependingonfinalstructuraldesigntheprojectwillbeeithermetalorwoodframingoramixture thereof, INTERIORARCHITECTURALWOODWORKINGANDCASEWORK •CabinetstobeincludedareasindicatedandshownontheLDAscopedrawingsnotedasfollows: o Reception/lobbydeskshallbeanFF&Eitemandnotincludedinthiscontract, o Standardplasticlaminatecabinets(Lowers&Uppers)-reducedduringvalueengineering, o Restroomsolidsurfacecountertops, o Pass-throughstainless-steelcountertopatlobby, o Kitchencabinetswillincludeplasticlaminatedcabinetswithsolidsurfacecountertops, o Laundrycabinetstobeplasticlaminatewithsolidsurfacecountertops, o Decontaminationareacabinettobestainlesssteel, o Bunkroomcabinets,wardrobelockers,desks,bunksandbunkfurnitureshallbeanFF&E itemandnotincludedinthecontract, o Thebalanceofthestorageshelving,shopcabinetsandmisc.cabinetsshallbeanFF&E itemandnotincludedinthecontract, WATERPROOFING,INSULATION,FIRESTOPING&SEALANTS •Waterproofingwillbeappliediforasnecessaryatthebuildingretainingwallifdesignrequires, •Newbuildingadditiontoincludeinsulationasrequiredtomeettitle24, •Newbuildingadditiontoincludeinsulationinallinteriorwallstoreducenoise, •Firestoppingwillbeincludedifandasnecessarytomeetthefireratingrequirements, •Caulkingandsealantswillbeincludedasnecessaryforawatertightbuilding, ROOFING •Newbuildingadditionatslopedareastobecompositionshingles, •NewbuildingadditionatflatareastobePVCroofingmembranewitha30-yearwarranty, •Existing apparatus bayroofing to beremoved and replaced with PVC roofing.Allexisting substrateandframingtoremainasis, •Roofingflashing&sheetmetaltobestandardandmeetrequirementsoftheroofingmanufacturer, DOORS,FRAMES,WINDOWS&HARDWARE •Doors,frames&hardwareareasnotedontheLDAscopedrawings, •Thedoorsandframeswillbeeitherhollowmetal,knock-downorwoodtomeetanyCityStandards, •Attheapparatusbay,threeoftheexistingdoorswillbegreasedandcleaned,theSoutheastdoor willberemovedandreplacedwithasimilardoortomatchascloseaspossibletheotherthreedoors toremain, •MirrorsattheexerciseroomwillbeanFF&Eitemandnotincludedinthecontract, •Thewindowswillbeastandardnail-on-finstyle, •Theglassstorefrontdoorstobestandarddoors, •Transactionwindowtobeastandardwindowwithacommunicationport&passthroughslot, •Thewindowswillbestandardstyle,non-ballisticrated, FINISHES •Gypsumboardwallsandceilingstobefinishedtoalevel4finish,primedandpaintedatexposed, •Cementboardatallrestroomwalls, •Exteriorwallsandsoffitstobecementsidingorpanels, •TilingatinteriorasindicatedontheLDAscopingdrawingsandtobe4x4Dal-tileatfloors&at kitchenbacksplashand2x2Dal-tileatwallsorequivalentandcoordinatedduringdesign, •Resilientflooring&rubberbaseisindicatedonLDAscopingdrawings, •Resinousflooring&baseisindicatedonLDAscopingdrawings, •FRPwallstobeasindicatedonLDAscopingdrawings, •AcousticceilingtilestobeasindicatedontheLDAscopingdrawings, MISCELLANEOUSITEMS •SignageatinteriorandexteriortobeasrequiredforADA&coderequiredsignageforpermitting, •ExterioraluminumletteringtobeasindicatedonLDAscopingdrawings, •Existingmonumentsignstoremain, •ToiletaccessoriestobeanFF&Eitemandnotincludedinthiscontractexceptfortheshowerseat asthisisarequiredADAitemforpermitting, •Fireextinguishers&cabinetswillbeasrequiredforpermit, •Metallockersinclude7standard,12turnoutand2benches, •Theoldflagpolewillberemoved,andanewflagpolewillbeinstalled, •AllkitchenandlaundryapplianceswillbefurnishedbytheCity&installedbyContractor, •WindowshadeswillbeanFF&Eitemandnotpartofthiscontract, FIREPROTECTION,PLUMBING&HVAC •FiresprinklerandfirelinesasdesignedbyS&MFireProtectiontomeetcode, •PlumbingsystemtobeasindicatedontheBoneso’sScopingDocuments, •HVACsystemtobeasindicatedontheBoneso’sScopingDocuments, ELECTRICAL •ElectricalsystemstobeasindicatedontheThoma’sScopingDocuments, SITEDEVELOPMENT •Thedevelopmentofsiteislimitedtoanewbuildingpad,2handicapparkingspacesandramp fromthehandicapparkingtothemainentrance, •Steelhandrailatrampfromhandicapparkingtomainentrance, •Fencingtobefutureandnotapartofthecontract, •Landscapingtobelimitedtothedisturbedsitearearequiredforthedevelopmentofthesiteas notedabove, •Stripingtobelimitedtothedevelopmentofthesiteasnotedabove, •Onebikerackisincludedtomeetcode, •SiteUtilitiesincludedomesticwaterline,fireline,connectionnearbuildingforexistingsewer line,stormdrain,andgasline(metertobuilding)isincludedasnecessaryfromeitherexistingor fromutilityconnectionatWestFrontRoad, •AllpermitsandutilityconnectionfeesaretobepaidbytheCity, GENERALCONDITIONSANDMISCELLANEOUSPROJECTITEMS •F&H’sreducedgeneralconditionsandsupervisiondonotincludeprovisionsforafull-time schedulertomeetschedulecostloading,resourceloading,andcostcorrelationrequirements(per SpecificationSection013200),afull-timeonsiteQA/QCmanager(perSpecificationSection01 4523),afull-timesafetymanager(perSpecificationSection015600),orafull-time commissioningcoordinator(perSpecificationSection019100).F&HConstructionaffirmsthat thegeneralconditionsandsupervisionprovidedaresufficienttomeettheproject’srequirements. Tosupportschedulingobligations,theContractorwillprovideathird-partyschedulerresponsible forprovidingweeklyP6scheduleupdatesandmonthlynarrativesincompliancewiththe progressschedulespecificationsexcludingcostloadingandresourceloading.TheContractor shallimplementaQA/QCplan,whichwillbemanagedbytheonsitesuperintendentwith oversightfromtheoffsitegeneralsuperintendent.Additionally,afull-timeprojectengineershall bedesignatedtocoordinatecommissioningactivitieswiththeOwner’sCommissioningAgent, •PermitsandutilityconnectionfeesaretobepaidbytheCity, •F&HincludesSWPPPplans,oversiteandimplementation, •Revised&NegotiatedLanguageforEscalation: o ContractorandOwnerrecognizethatOwnerhasalimitedbudgetof$31,072,318andthat there is the potential for material cost escalation should various events occur, both anticipatedandunanticipated,thatareoutsidethereasonablecontrolofbothparties.As necessitatedbysuchevents,OwnerandContractoragreetoworkingoodfaithtoidentify mutuallyacceptablechangestothescopingdocumentsincludinguseofalternativebut functionally-equivalentmaterials,manufacturers,equipmentorprocurementstrategies. o TheContractorshallprovidebudgetassessmentsatthecompletionofSchematicDesign andDesignDevelopmentphasestotheCity.Theseshallincludeanevaluationofpotential costescalationsanddesignsavings.TheContractorshallconductbudgetreviewswiththe Cityateachphase,andasotherwisedeemedreasonablyappropriatebyOwner,toidentify and mitigate cost escalation risks associated with materials, equipment and other procurement. o Contractoragreestotakecommerciallyreasonablemeasurestomitigateoravoidcost escalations, including preordering materials or systems, prioritizing long lead times, identifying alternative butfunctionally-equivalentmaterials,equipment,manufacturers and/orsystems,andtootherwisecooperatewithOwnertocometoamutuallyagreeable resolutionthatallowsthecompletionoftheprojectwithintheOwner’sbudget.Owner agrees to consider alternative but functionally-equivalent materials, equipment, manufacturersand/orsystems,toexpediteprocessingofsubmittalsforlongleadtime items,toreimburseContractorforpreorderedmaterialsorsystemsorderedearlywith Owner’sconsent,andtootherwisecooperatewiththeContractortocometoamutually agreeableresolutionthatallowsthecompletionoftheprojectwithintheOwner’sbudget. DN2A6.00FRONT SETBACK10'-0"SIDE SETBACK10'-0"-8"-5' 0"0"REAR SETBACK10'- 0".-8"-3' 0"SIDE SETBACK10'-0".DNDNDNDN4'-0"14'-0"18'-0"ATASCADERO PUBLIC SAFETY FACILITY - FIRE STATION 2SITE PLAN2/27/251/8" = 1'-0"110'4'8'16'32'SCALE 1/8" = 1'-0"TOS REVIEW: ShowEmergencyGenerator and PropaneTank along with enclosure orscreen walls?TOSREVIEW: Patio? FDWH2A6.001A6.012A6.011A6.00WELLNESSCENTERWATCHLOBBYRRSTORAGEBUNKBUNKBUNKBUNKMEDSTORAGERRRRSHOWERSHOWERITLAUNDRYTIERIIDECONEXISTINGAPPARATUSBAYDAYROOMDECONRRHALLTURNOUTSHOPJANEXISTING ROOMS TO BE RENOVATEDNEW CONSTRUCTION AND EXPANSION AREARENOVATION AREANEW ENTRY, OFFICE, SUPPORT SPACES, LIVING & SLEEPING QUARTERS3250 SFINDICATES ABOVEATASCADERO PUBLIC SAFETY FACILITY - FIRE STATION 2FLOOR PLAN2/27/253/16" = 1'-0"121EXISTING AREA = 2670 SF APPROX. NEW (ADDITION) AREA = 3250 SF APPROX.0'4'8'16'32'SCALE 1/8" = 1'-0"TOS REVIEW: This note conflict with the written narrative and the FF&E lists.Need to work with the City & F&H to align scope of work withFF&E listTOS REVIEW: City wants double doors to the exterior for exercise equipmentTOS REVIEW: City wants double doors to the exterior patioTOS COMMENT: City FD requested swapping the medicalstorage to have direct access to App BaysTOS COMMENT: Please consider swapping thelaundry to be closer to deconTOS COMMENT: Please confirm location ofexterior switchgear andlocation of mechanicalunitsMed Storage to open directly into App Bays FDWH2A6.001A6.012A6.011A6.00WELLNESSCENTERWATCHLOBBYRRSTORAGEBUNKBUNKBUNKBUNKMEDSTORAGERRRRSHOWERSHOWERITLAUNDRYTIERIIDECONEXISTINGAPPARATUSBAYDAYROOMDECONRRHALLTURNOUTSHOPJANNEW ENTRY, OFFICE, SUPPORT SPACES, LIVING & SLEEPING QUARTERS3250 SFATASCADERO PUBLIC SAFETY FACILITY - FIRE STATION 2FLOOR PLAN -CASEWORK2/27/253/16" = 1'-0"1310'4'8'16'32'SCALE 1/8" = 1'-0"TOS REVIEW: Per narrative, these should be covered by FF&E.Please confirm FDWH2A6.001A6.012A6.011A6.00DWWELLNESSCENTERWATCHLOBBYRRSTORAGEBUNKBUNKBUNKBUNKMEDSTORAGERRRRSHOWERSHOWERITLAUNDRYTIERIIDECONEXISTINGAPPARATUSBAYDAYROOMDECONRRHALLTURNOUTSHOPJANFLOOR FINISHRUBBER FLOORINGLVTCARPET TILEEPOXYCERAMIC FLOOR TILESEALED CONCRETEATASCADERO PUBLIC SAFETY FACILITY - FIRE STATION 2FLOOR FINISHES PLAN2/27/253/16" = 1'-0"610'4'8'16'32'SCALE 1/8" = 1'-0"TOS REVIEW: There should be one flooring material throughout the new building. FDpreference is polished concrete for easy maintenance. If LVT is less expensive, then it should be used in lieu of polished concreteEliminate carpet.If polished concrete is used, the ceramic tile area may be reduced to theshower area in each firefighter restroomTOS REVIEW: Epoxy in both these spacesTOS REVIEW: Provide static dissapative floor 2A6.001A6.012A6.011A6.00WELLNESSCENTERWATCHLOBBYRRSTORAGEBUNKBUNKBUNKBUNKMEDSTORAGERRRRSHOWERSHOWERITLAUNDRYTIERIIDECONEXISTINGAPPARATUSBAYDAYROOMDECONRRHALLTURNOUTSHOPJAN9'-0"9'-0"10'-0"9'-0"9'-0"9'-0"9'-0"9'-0"9'-0"9'-0"9'-0"8'-0"8'-0"8'-0"9'-0"9'-0"9'-0"10'-0"10'-0"10'-0"10'-0"7'-0"9'-6"10'-0"CEMENT BOARD SOFFIT24" x 48" TEGULAR ACOUSTICAL CEILING PANEL5/8" TYPE "X" GYPSUM BOARD, , PRIME & PAINTLEGENDNO CEILINGATASCADERO PUBLIC SAFETY FACILITY - FIRE STATION 2RCP2/27/253/16" = 1'-0"510'4'8'16'32'SCALE 1/8" = 1'-0" 2A6.001A6.012A6.011A6.004" / 12"4" / 12"4" / 12"4" / 12"16'-6"3/4" / 12"SPOT ELEVATIONSINGLE PLY ROOF MEMBRANELEGENDCOMPOSITION SHINGLESSINGLE-PLY CRICKET ROOFATASCADERO PUBLIC SAFETY FACILITY - FIRE STATION 2ROOF PLAN2/27/253/16" = 1'-0"910'4'8'16'32'SCALE 1/8" = 1'-0"TOS REVIEW:Please show roof drains and slopes FDWH2A6.001A6.012A6.011A6.00WELLNESSCENTERWATCHLOBBYRRSTORAGEBUNKBUNKBUNKBUNKMEDSTORAGERRRRSHOWERSHOWERITLAUNDRYTIERIIDECONEXISTINGAPPARATUSBAYDAYROOMDECONRRHALLTURNOUTSHOPJANNEW ENTRY, OFFICE, SUPPORT SPACES, LIVING & SLEEPING QUARTERS3250 SFATASCADERO PUBLIC SAFETY FACILITY - FIRE STATION 2FLOOR PLAN - WALLFINISHES2/27/253/16" = 1'-0"1410'4'8'16'32'SCALE 1/8" = 1'-0"MEDSTORAGETOS REVIEW: Please remove. Covered in FF&E as Cityprovided, contractor installed.TOS REVIEW: FRP in both these spaces on the wallsTOS REVIEW: Exposed rated plywood as wall finishTOS REVIEW: Please define height of the ceramic tile wallsTOS REVIEW:Why are corner guards not shown on FS 2Legend and Floor Plan?TOS REVIEW: FRP on walls in this space 2A6.001A6.012A6.011A6.00WELLNESSCENTERWATCHLOBBYRRSTORAGEBUNKBUNKBUNKBUNKMEDSTORAGERRRRSHOWERSHOWERITLAUNDRYTIERIIDECONEXISTINGAPPARATUSBAYDAYROOMDECONRRHALLTURNOUTSHOPJAN9'-0"9'-0"10'-0"9'-0"9'-0"9'-0"9'-0"9'-0"9'-0"9'-0"9'-0"8'-0"8'-0"8'-0"9'-0"9'-0"9'-0"10'-0"10'-0"10'-0"10'-0"7'-0"10'-0"9'-6"7'-0"CEMENT BOARD SOFFIT24" x 48" TEGULAR ACOUSTICAL CEILING PANEL5/8" TYPE "X" GYPSUM BOARD, TEXTURE, PRIME & PAINTLEGENDNO CEILINGWALL LEGENDEXISTING WALL TO REMAIN LEVEL 2 -MEDIUM PRIVACY (FULL HT.)LEVEL 3 -HIGH PRIVACY (FULL HT.)NEW CONSTRUCTION WALL LEVEL 1 -LOW PRIVACY ATASCADERO PUBLIC SAFETY FACILITY - FIRE STATION 2RCP - PRIVACY2/27/253/16" = 1'-0"1510'4'8'16'32'SCALE 1/8" = 1'-0"TOS REVIEW: Confirm if existing ceiling is toremain?TOS REVIEW:Provide STC ratings for all wall typesTOS REVIEW: Level 3TOS REVIEW: Level 3 at all restroom walls EXISTING PLASTERSTUCCOEXISTING OVERHEAD DOORSEXISTING PLASTERSTUCCOCOMPOSITE SHINGLE ROOFEXISTING PLASTEREXISTING OVERHEAD DOORSCITY OF ATASCADEROATASCADERO PUBLIC SAFETY FACILITY - FIRE STATION 2ELEVATIONS2/10/20241/8" = 1'-0"541/8" = 1'-0"531/8" = 1'-0"511/8" = 1'-0"520'4'8'16'32'SCALE 1/8" = 1'-0"TOS REVIEW: Which overhead door is the new one per narrativeTOS REVIEW: Confirm new paint over existing plasterTOS REVIEW: Confirm if there is an integral color coat for the plaster system for the baseand field colors. Or if the color is applied by paint. POLICEDEPARTMENT–VE/FINALCONSTRUCTIONSCOPINGDOCUMENT AtascaderoPoliceStationislocatedat5505ElCaminoReal,Atascadero,CA.Thesiteiscurrentlyinuse astheAtascaderoPoliceDepartment.Theprojectwillconsistofanewdispatchbuilding,arenovationto theexistinglockerroomstomakeanewexpandedmen’slockerroomandrestroomarea,andarenovation oftheexistingholdingcellareatoaccommodateanewwomen’slockerroomandrestroomarea.The remainderoftheexistingbuildingwillincluderoofingrepairsasindicatedandprovidedbytheWick’s roofingreportandtheinteriorfinishesthatarelimitedtoandincluding:repairsofminorexistingjoint& acousticalsealants,gypsumboardpatch&repairs,removingandreplacingofexistingacousticaltile ceilings,replacementofexistingcarpet&vinyltileflooring,repaintingofexistingwallsandceilings,and replacementofelectricalcoverplatesasrequired. Thesitespans1.31acresandcurrentlyfeaturesexistingparking,undergroundandoverheadutilities,an auxiliarystoragebuilding,and2coveredparkingareas.Plannedsiteimprovementsarebeinglimitedto onlythoserequiredforthenewDispatchBuilding.Inaddition,nositeretainingwallrepairsareincluded norhaveanynewfencingbeenaddedexcepttosecurethenewDispatchBuilding. Therenovatedpolicestationisexpectedtoremainasisandhasonlychangestothefinishesbeingcompleted withnostructuralmodificationsthatwillbemade. SCOPEITEMSBYSPECIFICATION F&HConstruction’s(F&H)ScopingDocumentsprovidedF&H,LDAPartners(LDA),BonesoPlumbing and Mechanical (Boneso), Thoma Electric (Thoma), and associated consultants by shall govern the projectscope.ThefollowingscopesidentifiedintheRFP’sDetailedSpaceUseRequirementssection havebeenmodifiedandtheoriginalRFPscopeisnotapplicabletothesescopes.Scopeforthefollowing itemsisasdefinedinthecontractor'sprovideddocuments:Security,FloorLevelLocation,Isolation, Floor Finish, Wall Finish, Ceiling Finish, Ceiling Height, Sound/Acoustic Treatment, Casework, CaseworkType,Countertops,SpecialRequirements,andMechanicalandElectricalRequirements. DEMOLITION •Demolitionofsitemasonrywall,demolitionofsiteitemstoallowfortheconstructionofthe DispatchBuilding, •Selectivedemolitionat(e)lockerroomareaasindicatedontheLDAscopedrawings, •Selectivedemolitionat(e)holdingcellareaasindicatedontheLDAscopedrawings, BUILDINGCONCRETE •Standard Concrete foundations and slabs will be designed by the structural engineer & in accordancewiththesoilsreportforthenewDispatchBuilding, BRICKMASONRY •Nomasonryiscontemplatedforthissite. STRUCTURALFRAMING •Dependingonfinalstructuraldesigntheprojectwillbeeitherlightgaugemetalframingorwood framingoramixturethereof, INTERIORARCHITECTURALWOODWORKINGANDCASEWORK •CabinetstobeincludedareasindicatedandshownontheLDAscopedrawingsnotedasfollows: o Kitchen/Breakroomcabinetsincludeplasticlaminatedcabinetswithsolidsurfacetops, o Thebalanceofthestorageshelving,shopcabinetsandmisc.cabinetsshallbeFF&Eand notincludedinthecontract, WATERPROOFING,INSULATION,FIRESTOPING&SEALANTS •Waterproofingwillbeappliediforasnecessaryatthebuildingretainingwallifdesignrequires, •NewDispatchBuildingtoincludeinsulationasrequiredtomeettitle24, •NewDispatchBuildingtoincludeinsulationinallinteriorwallstoreducenoise, •Firestoppingwillbeincludedifandasnecessarytomeetthefireratingrequirements, •Caulkingandsealantswillbeincludedasnecessaryforawatertightbuilding, ROOFING •NewDispatchBuildingflatrooftobePVCroofingmembranewitha30-yearwarranty, •RoofrepairsatexistingPDBuildingtoberepairedperWick’sRoofingreportprovided, •Roofingflashing&sheetmetaltobeperRFPandwillmeettheroofmanufacturer’sstandards, DOORS,FRAMES,WINDOWS&HARDWARE •Doors,frames&hardwareareasnotedontheLDAscopedrawings, •Thedoorsandframeswillbeeitherhollowmetal,knock-downorwoodtomeetanyCityStandards, •Theglassstorefrontdoorstobestandarddoors(non-ballisticrating), •Thewindowswillbestandardstyle(non-ballisticrated), FINISHES •Gypsumboardwallsandceilingstobefinishedtoalevel4finish,primedandpaintedatexposed, •Cementboardatallrestroomwalls, •Exteriorwallsportlandcementplaster, •TilingatinteriorasindicatedontheLDAscopingdrawingsandtobe4x4Dal-tileatfloors&at kitchenbacksplashand2x2Dal-tileatwallsorequivalentandcoordinatedduringdesign, •Resilientflooring&rubberbaseisindicatedonLDAscopingdrawings, •AcousticceilingtilestobeasindicatedontheLDAscopingdrawings, MISCELLANEOUSITEMS •SignageatinteriorandexteriortobeasrequiredforADA&coderequiredsignageforpermitting, •ToiletaccessoriestobeanFF&Eitemandnotincludedinthiscontractexceptfortheshowerseat asthisisarequiredADAitemforpermitting, •Fireextinguishers&cabinetswillbeasrequiredforpermit, •Metallockersinclude41atmen’slockerroomand14atwomen’slockerroomand2benches, •AllkitchenapplianceswillbefurnishedbytheCity&installedbyContractor, •WindowshadeswillbeanFF&Eitemandnotpartofthiscontract, FIREPROTECTION,PLUMBING&HVAC •FiresprinklerandfirelinesasdesignedbyS&MFireProtectiontomeetcode, •PlumbingsystemtobeasindicatedontheBoneso’sScopingDocuments, •HVACsystemtobeasindicatedontheBoneso’sScopingDocuments, ELECTRICAL •ElectricalsystemstobeasindicatedontheThoma’sScopingDocuments, SITEDEVELOPMENT •ThedevelopmentofthesiteislimitedtowhatisnecessaryforthenewDispatchBuildingand buildingpad, •FencingtobelimitedtotheareabetweentheexistingPDandthenewDispatchBuilding, •LandscapingtobelimitedtothedisturbedsiteareafortheDispatchBuilding •SiteUtilitiesincluderoutingdomesticwaterline,fireline,sewerline,andgaslinenecessaryfrom thenewDispatchBuilding, •EncroachmentpermitfeetobepaidfororatnocostfromtheCity, GENERALCONDITIONSANDMISCELLANEOUSPROJECTITEMS •F&H’sreducedgeneralconditionsandsupervisiondonotincludeprovisionsforafull-time schedulertomeetschedulecostloading,resourceloading,andcostcorrelationrequirements(per SpecificationSection013200),afull-timeonsiteQA/QCmanager(perSpecificationSection01 4523),afull-timesafetymanager(perSpecificationSection015600),orafull-time commissioningcoordinator(perSpecificationSection019100).F&HConstructionaffirmsthat thegeneralconditionsandsupervisionprovidedaresufficienttomeettheproject’srequirements. Tosupportschedulingobligations,theContractorwillprovideathird-partyschedulerresponsible forprovidingweeklyP6scheduleupdatesandmonthlynarrativesincompliancewiththe progressschedulespecificationsexcludingcostloadingandresourceloading.TheContractor shallimplementaQA/QCplan,whichwillbemanagedbytheonsitesuperintendentwith oversightfromtheoffsitegeneralsuperintendent.Additionally,afull-timeprojectengineershall bedesignatedtocoordinatecommissioningactivitieswiththeOwner’sCommissioningAgent, •AllpermitsandutilityconnectionfeesaretobepaidbytheCity, •F&HincludesSWPPPplans,oversiteandimplementation, •Revised&NegotiatedLanguageforEscalation: o ContractorandOwnerrecognizethatOwnerhasalimitedbudgetof$31,072,318andthat there is the potential for material cost escalation should various events occur, both anticipatedandunanticipated,thatareoutsidethereasonablecontrolofbothparties.As necessitatedbysuchevents,OwnerandContractoragreetoworkingoodfaithtoidentify mutuallyacceptablechangestothescopingdocumentsincludinguseofalternativebut functionally-equivalentmaterials,manufacturers,equipmentorprocurementstrategies. o TheContractorshallprovidebudgetassessmentsatthecompletionofSchematicDesign andDesignDevelopmentphasestotheCity.Theseshallincludeanevaluationofpotential costescalationsanddesignsavings.TheContractorshallconductbudgetreviewswiththe Cityateachphase,andasotherwisedeemedreasonablyappropriatebyOwner,toidentify and mitigate cost escalation risks associated with materials, equipment and other procurement. o Contractoragreestotakecommerciallyreasonablemeasurestomitigateoravoidcost escalations, including preordering materials or systems, prioritizing long lead times, identifying alternative butfunctionally-equivalentmaterials,equipment,manufacturers and/orsystems,andtootherwisecooperatewithOwnertocometoamutuallyagreeable resolutionthatallowsthecompletionoftheprojectwithintheOwner’sbudget.Owner agrees to consider alternative but functionally-equivalent materials, equipment, manufacturersand/orsystems,toexpediteprocessingofsubmittalsforlongleadtime items,toreimburseContractorforpreorderedmaterialsorsystemsorderedearlywith Owner’sconsent,andtootherwisecooperatewiththeContractortocometoamutually agreeableresolutionthatallowsthecompletionoftheprojectwithintheOwner’sbudget. EL CAMINO REALROSARIO AVE.NEW DISPATCHEXISTING POLICE DEPARTMENT(E) STRUCTUREPATIO(E) LANDSCAPE/ TURFLEGEND(E) CONCRETE WALK/ FLAT WORK(E) AC PAVING(N) CONCRETE WALK/ FLAT WORK(E) FENCING/RAILING(E) TREEATASCADERO PUBLIC SAFETY FACILITY - DISPATCHSITE PLAN2/28/20251/16" = 1'-0"P1.001032'48'64'16'Graphic Scale: 1 inch = 16 feetTOS REVIEW: Confirm that new security fencing willconnect with existing secured parkingand pedestrian gates.TOS REVIEW: Confirm accessible path of travel fromparking to dispatch building, additionalsite work may be needed toaccommodate a ramp.TOS REVIEW: Confirm retaining wall is provided orneeded?TOS REVIEW: Overex of foundation system mayrequire the replacement of existing siteimprovementsVanir - also provide security fence in this area to maintain secure area 2P6.011P6.014P6.013P6.01BREAKROOMDISPATCHOFFICEITT/SHALLWAYOFFICEITT/SDISPATCHBREAKROOM9'-0"7'-0"9'-0"10'-0"9'-0"9'-0"9'-0"9'-0"7'-0"PRE-ENGINEERED METAL AWNING24" x 48" TEGULAR ACOUSTICAL CEILING PANEL5/8" TYPE "X" GYPSUM BOARD, PRIME & PAINTRCP LEGENDEIFS CORNICE CAPPLAN LEGENDDOORDOOR & SIDELITEWINDOWSMETAL AWNING ABOVEDISPATCH WALLSITE WALLATASCADERO PUBLIC SAFETY FACILITY - DISPATCHFLOOR PLAN & RCP2/28/20251/4" = 1'-0"P1.0111/4" = 1'-0"P1.01208'12'16'4'Graphic Scale: 1 inch = 4 feetTOS REVIEW: This note conflict with the written narrative andthe FF&E lists. Clarify if dispatch consoles are tobe included in scope or City Provided.TOS REVIEW: City IT prefers acoustical ceilings inthe IT spaceSite Plan shows this entire area covered. This will be needed so traffic between buildings can be covered 3/8" / 12"3/8" / 12"BREAKROOMDISPATCHOFFICEITT/SHALLWAYFINISH LEGENDLVT FLOORINGCERAMIC TILESTATIC DISSIPATIVE FLOORINGPRE-ENGINEERED METAL AWNINGSINGLE PLY ROOF MEMBRANEROOF LEGENDROOF DRAIN1/4" = 1'-0"P1.021ATASCADERO PUBLIC SAFETY FACILITY - DISPATCHROOF PLAN & FINISHPLAN2/28/20251/4" = 1'-0"P1.02208'12'16'4'Graphic Scale: 1 inch = 4 feet BREAKROOMDISPATCHOFFICEITT/SHALLWAYBREAKROOMDISPATCHOFFICEITT/SHALLWAYWALL LEGEND(N) WALL LEVEL 1 LOW PRIVACY(N) WALL LEVEL 2 MEDIUM PRIVACY (FULL HEIGHT)(N) WALL LEVEL 3 HIGH PRIVACY (FULL HEIGHT)WALL FINISH LEGENDCERAMIC TILESTILED BACKSPLASHWALL CORNER GUARDSUNMARKED WALLS TO BE LEVEL 4 DRYWALL; PAINTEDATASCADERO PUBLIC SAFETY FACILITY - DISPATCHWALL TYPES AND WALLFINISHES2/28/20251/4" = 1'-0"P1.0311/4" = 1'-0"P1.03208'12'16'4'Graphic Scale: 1 inch = 4 feetTOS REVIEW: Please define height of the ceramictile wallsTOS REVIEW: FRP on walls in ITTOS REVIEW: PD would like to add or relocatewindow and awning to this location.TOS REVIEW: Level 3 T.O SLAB0"T.O. WAINSCOT4' - 0"T.O. DISP. PARAPET18' - 0"T.O SLAB0"T.O. WAINSCOT4' - 0"T.O. DISP. PARAPET18' - 0"T.O SLAB0"T.O. WAINSCOT4' - 0"T.O. DISP. PARAPET18' - 0"T.O SLAB0"T.O. WAINSCOT4' - 0"T.O. DISP. PARAPET18' - 0"ATASCADERO PUBLIC SAFETY FACILITY - DISPATCHBUILDING ELEVATIONS2/28/20251/4" = 1'-0"P6.0111/4" = 1'-0"P6.0121/4" = 1'-0"P6.0131/4" = 1'-0"P6.014COLOR 1 STUCCOCOLOR 2 STUCCOEIFS CORNICE CAPEIFS BANDPRE-ENGINEERED METAL AWNING08'12'16'4'Graphic Scale: 1 inch = 4 feetTOS REVIEW: Confirm if there is an integral color coat for theplaster system for the base and field colors. Or ifthe color is applied by paint.TOS REVIEW: PD would like to add or relocatewindow and awning to this location. GENERAL FINISH NOTEPD RENOVATION -NEW ACOUSTICAL CEILING TILES, PAINT, FLOORING TO MATCH EXISTING BUILDING FINISHES.111112113105153151150148149147145144143165142141157156155154109101102159162163161160126139138MEN'S LOCKER RM.T/S.SHWR.41T/SSHWR.136134135131131129128132133146152WOMEN'S LOCKER ROOM10711014SAMPLESNEW DISPATCHFINISH LEGENDCERAMIC TILEEPOXY/ RUBBER FLOORINGATASCADERO PUBLIC SAFETY FACILITYPD RENOVATION FLOORFINISH PLAN3/3/2025016'24'32'8'Graphic Scale: 1 inch = 8 feet1/8" = 1'-0"P2.011TOS REVIEW:Confirm fixture countis enough to meetcodeandsupport41 lockers.TOS REVIEW: Confirm fixture countis enough to meetcodeandsupport 14 lockers.TOS REVIEW: PD would like to keep the existingdoor and wall to create vestibule forvisual and sound privacyTOS REVIEW: PD would like to add door and wall tocreate vestibule for visual and soundprivacyTOS REVIEW: PD would like to add door and wall tocreate vestibule for visual and soundprivacyTOS REVIEW: PD would like remove all existinginterior walls to create a larger room GENERAL FINISH NOTEPD RENOVATION -NEW ACOUSTICAL CEILING TILES, PAINT, FLOORING TO MATCH EXISTING BUILDING FINISHES.OPEN TO STRUCTUREVARIESWOMEN'S LOCKER ROOMT/S105T/SNEW DISPATCHEXISTING CEILING TO REMAIN;PATCH, REPAIR AND PAINT5/8" TYPE "X" GYPSUM BOARD, TEXTURE, PRIME & PAINTLEGEND1/8" = 1'-0"P2.021ATASCADERO PUBLIC SAFETY FACILITYPD RENOVATION RCP3/3/2025016'24'32'8'Graphic Scale: 1 inch = 8 feetIs the ceiling in this area also to remain: patch, repair and paint? GENERAL FINISH NOTEPD RENOVATION -NEW ACOUSTICAL CEILING TILES, PAINT, FLOORING TO MATCH EXISTING BUILDING FINISHES.111112113105153151150148149147145144143165142141157156155154109101102159162163161160126139138MEN'S LOCKER RM.T/S.SHWR.41T/SSHWR.136134135131131129128132133146152WOMEN'S LOCKER ROOM10711014SAMPLESNEW DISPATCHWALL FINISH LEGENDCERAMIC TILESATASCADERO PUBLIC SAFETY FACILITYPD RENOVATION WALLFINISH PLAN3/3/2025016'24'32'8'Graphic Scale: 1 inch = 8 feet1/8" = 1'-0"P2.031TOS REVIEW: Please define height of the ceramictile walls PATIOFUTURETRAININGAREAMECHSHOPTURNOUT2TURNOUT1S.C.B.A.APPBAY1MEDICALSTOR.EXERC.BREAKWORKSERVERELECT.E.O.C.STOR.STOR.TRAININGBREAKOUTEXEC.LOBBYMENWOMENFIREINSP.R.R.STOR.QUIETWATCHELEVADMINFIREMARSHALOPSCHIEFDEPCHIEFFIRECHIEFB.C.&CAPTAINOFFICEDECONIDFDS-1IDU251SQ.FT.1.5-TONDUCTLESSHIGHWALLSPLITDS-2IDU87SQ.FT.1.5-TONDUCTLESSHIGHWALLSPLITFC-1.1.4100SQ.FT.0.5-TONVRFCASSETTEUH-1,2,3,44607SQ.FT.(4)125,000BTUHGASUNITHEATERSEF-SHOP92SQ.FT.375CFMEAROOFTOPFANEF-TURNOUT2155SQ.FT.500CFMEAROOFTOPFANEF-TURNOUT1155SQ.FT.500CFMEAROOFTOPFANEF-SCBA171SQ.FT.2400CFMEAROOFTOPFANEF-DECON234SQ.FT.550CFMEAROOFTOPFANEF-ELEVEQUIP62SQ.FT.125CFMEAROOFTOPFAN93SQ.FT.200CFMEAEXHAUSTW/ERV-1348SQ.FT.550CFMEAEXHAUSTW/ERV-1FC-1.2.1THRU1.2.4217SQ.FT.(4)2-TONVRFDUCTLESSHIGHWALLSEF-APPBAY1(2)2250CFMIN-LINEFANSTOROOFEXHAUSTHOODSVARIABLESPEED,BASEDONCOSENSORMAKEUPAIRBYWALLLOUVERS(3)NEWNEDERMANVEHICLEEXHAUSTRAILS,AUTO-CRABRETURNANDHOSEDROPPERVEHICLE,AND(1)VEHICLEEXHAUSTFANONROOFEF-BREAK164SQ.FT.100CFMEAROOFTOPFANPHP-1.11390SQ.FT.5-TONPACKAGEDHEATPUMPECONOMIZERMODULATINGPOWEREXHAUSTSTRUCTURALLYCALC'DISOLATIONCURBFC-1.1.1229SQ.FT.1-TONVRFCASSETTEVENTILATIONBYERV-1FC-1.1.2286SQ.FT.1-TONVRFCASSETTEVENTILATIONBYERV-1PHP-1.2997SQ.FT.5-TONPACKAGEDHEATPUMPECONOMIZERMODULATINGPOWEREXHAUSTSTRUCTURALLYCALC'DISOLATIONCURBPHP-1.31100SQ.FT.4-TONPACKAGEDHEATPUMPECONOMIZERMODULATINGPOWEREXHAUSTSTRUCTURALLYCALC'DISOLATIONCURBFC-1.1.3161SQ.FT.0.75-TONVRFCASSETTEVENTILATIONBYERV-1FC-1.1.5145SQ.FT.0.75-TONVRFCASSETTEVENTILATIONBYERV-1FC-1.1.6145SQ.FT.0.75-TONVRFCASSETTEVENTILATIONBYERV-1FC-1.1.8235SQ.FT.1.25-TONVRFCASSETTEVENTILATIONBYERV-1FC-1.1.7194SQ.FT.1-TONVRFCASSETTEVENTILATIONBYERV-1ONROOF:-PACKAGEDHEATPUMPSPHP-1.1,1.2,1.3,2.1-9.5-TONVRFHEATRECOVERYCONDENSERHRC-1-2-TONCONDENSINGUNITHPC-2-8-TONCONDENSINGUNITCU-2-1.5-TONOUTDOORCONDENSERSDS-1,2ODUs-950CFMERV-1ENERGYRECOVERYVENTILATOR-ALLROOFTOPEXHAUSTFANS-VEXFAN-INLINE-FANEXHAUSTHOODSNOTSHOWN:-(2)BRANCHSELECTORBOXESFORVRFSYSTEMELEVEQUIPFC/HPC-2535SQ.FT.2-TONDUCTEDSPLITSYSTEMHOSEEF-HOSE94SQ.FT.200CFMEAROOFTOPFANR.R.60SQ.FT.100CFMEAEXHAUSTW/ERV-1UH-5,6(2)35,000BTUHGASUNITHEATERSC:\Users\bstarrett\appdata\local\temp\AcPublish_21152\AtascaderoPSFFS1HeadquartersPlan.dwgbstarrettJan10,2025-5:16pmFIRESTATION1-SCHEMATICPLANATASCADEROPUBLICSAFETYFACILITY1/6/2025NEWBUILDINGFIRSTFLOORPLANNEWBUILDINGFIRSTFLOORPLANSCALE:1/8"=1'-0"CONTROLS:NOCENTRALCONTROLLER.THERMOSTATANDTIMERCONTROLLED.5-HPAIRCOMPRESSOR PATIOELEV.R.R.BEDROOM5BEDROOM4BEDROOM3BEDROOM2BEDROOM1KITCHEN/DAYROOMJAN./STOR.FC-2.1.1127SQ.FT.0.5-TONVRFCASSETTEVENTILATIONBYERV-1FC-2.1.4121SQ.FT.0.5-TONVRFCASSETTEVENTILATIONBYERV-1FC-2.1.5124SQ.FT.0.5-TONVRFCASSETTEVENTILATIONBYERV-1PHP-2.12130SQ.FT.5-TONPACKAGEDHEATPUMPECONOMIZERMODULATINGPOWEREXHAUSTSTRUCTURALLYCALC'DISOLATIONCURBRANGEHOOD,SEEARCH.TERMINATEEXHAUSTPERMANUFACTURER'SREQUIREMENTSFC-2.1.3121SQ.FT.0.5-TONVRFCASSETTEVENTILATIONBYERV-1FC-2.1.2121SQ.FT.0.5-TONVRFCASSETTEVENTILATIONBYERV-1SERVEDBYERV-1950CFMOA&EAROOFTOPUNITWH-1GAS-FIREDWATERHEATERAOSMITHBTH-150,100GALMEZZANINELAUND.R.R.R.R.FC-2.1.6213SQ.FT.0.5-TONVRFCASSETTEVENTILATIONBYERV-1BEDROOM6C:\Users\bstarrett\appdata\local\temp\AcPublish_21152\AtascaderoPSFFS1HeadquartersPlan.dwgbstarrettJan10,2025-5:16pmFIRESTATION1-SCHEMATICPLANATASCADEROPUBLICSAFETYFACILITYNEWBUILDINGSECONDFLOORPLANSCALE:1/8"=1'-0"1/6/2025NEWBUILDINGSECONDFLOORPLAN 111112113105153151150148149147145144143165142141157156155154109101102159162163161160126139138MEN'S LOCKER RM.T/S.SHWR.41T/SSHWR.136134135131131129128132133146152WOMEN'S LOCKER ROOM10711014SAMPLESNEW DISPATCHWALL LEGEND(N) WALL(E) WALLWALL TO BE DEMOLISHEDATASCADERO PUBLIC SAFETY FACILITYPD RENOVATION FIRSTFLOOR PLAN3/3/2025016'24'32'8'Graphic Scale: 1 inch = 8 feet1/8" = 1'-0"P2.0011-TONPACKAGEDHEATPUMPECONOMIZERMODULATINGPOWEREXHAUSTSTRUCTURALLYCALC'DISOLATIONCURB1-EFDISPATCHLOCKER98SQ.FT.190CFMEAROOFTOPFANEF-COMMANDLOCKERS130SQ.FT.225CFMEACEILINGEXHAUSTFANEF-MENLOCKERS858SQ.FT.2300CFMEAROOFTOPEA606.44 sfEF-WOMENLOCKERS607SQ.FT.1150CFMEAROOFTOPFAN Boneso Plumbing & Mechanical. 2758 Concrete Ct. Paso Robles CA 93446 (805) 227-4450 • (805) 227-4502 Fax The following Scopes is for HVAC and Plumbing (inclusions, clarifications, exclusions as shown below): INCLUSIONS: General Scope • Commissioning assist • Submittals, operation and maintenance manuals and as-built drawings • Boneso is the design-build subcontractor for Plumbing and HVAC, including the engineering for both • Insulation for HVAC and Plumbing and a minimum requirements per Title 24 • Firestopping for HVAC and Plumbing, other firestopping is by other trades under F&H • Seismic/anchorage for HVAC and Plumbing is by Boneso. Other trades are under F&H HVAC Base Bid includes Fire Station 1 • Per revised floor plans dated 1/6/2025 • (3) 5 ton Lennox Packaged Heat Pump units with flat roof curbs and electric heat strips for defrost mode • (1) 4 ton Lennox Packaged Heat Pump units with flat roof curbs • (4) Unit Heaters 125,000 BTU/Hr unit for apparatus bay heating • (2) Unit Heaters 35,000 BTU/Hr unit for Turnout areas • (8) Hitachi VRF cassette fan coils and (1) roof mounted Heat Pump condensing units o (3) 1-ton units o (1) 1.25-ton unit o (3) 0.75-ton units o (1) 0.5-ton unit • (4) Hitachi 2-ton VRF wall mount fan coils and (1) roof mounted Heat Pump condensing units for server room • (2) Hitachi BC controllers • (1) 2-ton Hitachi split system, fan coil and condensing units for exercise room • (1) 1.5-ton Hitachi split system, fan coil and condensing unit for electrical room • (1) 1-ton Hitachi split system, fan coil and condensing unit for the storage room • (1) S&P Ventilation Energy Recovery Unit 950 CFM • (2) 2250 CFM Acme Inline Exhaust Fans for App Bay • (1) 200 CFM Acme Rooftop Exhaust Fan for Hose Room • (2) 500 CFM Acme Rooftop Exhaust Fans for Turnout Rooms • (1) 2400 CFM Acme Rooftop Exhaust Fan for SCBA Room • (1) 375 CFM Acme Rooftop Exhaust Fan for Shop • (1) 125 CFM Acme Rooftop Exhaust Fan for Elevator Equipment Room • (1) 550 CFM Acme Rooftop Exhaust Fan for Decon Room • (1) 100 CFM Acme Rooftop Exhaust Fan for Breakroom • (1) Nerderman vehicle exhaust system with 5 drops • Makeup Air Wall Louvers in App Bay • Wall louver for SCBA room Boneso Plumbing & Mechanical. 2758 Concrete Ct. Paso Robles CA 93446 (805) 227-4450 • (805) 227-4502 Fax • Low voltage wiring to thermostats. No central controller • Air Distribution • 3rd Party Test and Air Balance HVAC Base Bid includes Fire Station 2 • Per revised floor plans dated 2/28/2025 • (1) 7.5 ton Lennox Packaged Heat Pump unit with flat roof curbs with electric heat strips for defrost mode • (1) 2 ton Lennox Packaged Heat Pump unit with flat roof curbs for exercise room with electric heat strips for defrost mode • (2) Unit Heaters 125,000 BTU/Hr for the Apparatus Bay • (4) 0.5 Ton Hitachi Mini Split ducted fan coils and (1) roof mounted Heat Pump condensing units • (1) 1.5 Ton Hitachi split systems, fan coils and condensing units • (1) S&P Ventilation Energy Recovery Unit 550 CFM • (1) 325 CFM Acme Exhaust Fan, Roof Mounted • (1) 325 CFM Acme Exhaust Fan, Roof Mounted for Decon Room • (1) 200 CFM Acme Exhaust Fan, Roof Mounted for Electrical Room • (1) 375 CFM Acme Exhaust Fan, Roof Mounted for Turnout Room • (1) 100 CFM Acme Exhaust Fan, Roof Mounted for Storage Room • (1) 100 CFM Acme Exhaust Fan, Roof Mounted for Janitors Room • (1) 3000 CFM Acme Inline Exhaust Fans • Louvers for App Bay Make-Up Air • (1) Nerderman vehicle exhaust system with 2 drops • Low voltage wiring to thermostats. No central controller • Air Distribution • 3rd Party Test and Air Balance HVAC Base Bid includes Police Department with Dispatch Office • Per revised renovation plan & Dispatch plan dated 2/28/2025 & 3/3/2025 respectively • Dispatch Office: o (1) 4 ton Lennox Packaged Heat Pump units with flat roof curbs for new server room with electric heat strips for defrost mode o (1) 1.5 Ton Hitachi Split Systems, Fan coil and condensing unit for IT room o (1) 300 CFM Acme Exhaust Fan for the Dispatch Restroom o (1) 300 CFM Acme Exhaust Fan for Break Room o Low voltage wiring to thermostats. No central controller o 3rd Party Test and Air Balance • Men’s & Women’s Locker Room / Restrooms: o (1) 2300 CFM Acme exhaust fan for the Men’s Locker Room / Restrooms o (1) 700 CFM Acme exhaust fan for the Women’s Locker Room / Restrooms o (1) 225 CFM Acme exhaust fan for the Command Locker Room / Restrooms o Low voltage wiring to thermostats. No central controller o 3rd Party Test and air balance only for construction areas (locker rooms and dispatch office) Boneso Plumbing & Mechanical. 2758 Concrete Ct. Paso Robles CA 93446 (805) 227-4450 • (805) 227-4502 Fax Plumbing General Scope inclusions: • Per revised floor plans dated 1/6/2025 • Drain waste & vent piping (AG – PVC DWV, UG – PVC DWV) • Domestic water piping (Type L ProPress) • Compressed air piping (Sch 40 Blk Threaded) • Natural gas piping to unit heaters in Apparatus Bays (Sch 40 Blk Threaded, 2 ½” & Larger Welded) • Condensate drain piping (Type L ProPress) • Trap primer piping (Type K Soft) • Plumbing within 5’ of each building for all systems. Beyond 5’ by site contracor • Plumbing fixtures • Excavation/backfill for plumbing scope • Insulation for domestic hot water and condensate only • Firestopping for plumbing scope • Seismic/anchorage for plumbing scope • Chlorination for domestic water system Plumbing Base Bid includes Fire Station 1 • Per revised floor plans dated 1/6/2025 • (4) Wall Mounted Water Closets • (5) Floor Mounted Water Closets • (9) Lavatories • (5) Showers • (2) Drinking Fountain with bottle filler. No cooler. • (2) Janitors Mop Sinks • (1) Quite Room Sink • (1) Break Room Sink • (1) 2-compartment Kitchen Sink • (1) Island Sink • (1) Laundry Sink • (3) Floor Drains • (1) Floor Sink • (4) Hose Bibbs • (1) 100-Gallon Gas Water Heater 150,000 BTU/Hr • (1) Circulation Pump • (1) Thermostatic Mixing Valve • (1) 5 Horse Power Air Compressor • (3) Compressed Air Drops in App bay with hose reels • (1) Compressed Air Drop for shop with hose reel • (1) Ice Maker Box • (1) Laundry Supply Box • (1) Gas Outlet Box for Dryer • Waste, vent and trap primer hookups for trench drains. Trench drains will be provided and installed by the concrete subcontractor or F&H. Waste to run to exterior Sand oil interceptor to be connected and installed by site contractor. Boneso Plumbing & Mechanical. 2758 Concrete Ct. Paso Robles CA 93446 (805) 227-4450 • (805) 227-4502 Fax Plumbing Base Bid includes Fire Station 2 • Per revised floor plans dated 2/28/2025 • (4) Water Closets • (4) Lavatories • (3) Showers • (1) High Low Drinking Fountain with bottle filler. No cooler. • (1) Janitors Mop Sink • (1) Break Room Sink • (1) 2-compartment Sink for Decon Room • (1) Laundry Sink • (4) Floor Drains • (1) 100-Gallon Gas Water Heater 150,000 BTU/HR • (1) Thermostatic Mixing Valve • (1) Ice Maker Box • (1) Laundry Supply Box • (1) Gas Outlet Box for Dryer • Gas hookups to stove in day room • (1) 5 Hp Air Compressor for App Bay Plumbing Base Bid includes Police Department with Dispatch Office • Per revised renovation plan & Dispatch plan dated 2/28/2025 & 3/3/2025 respectively • Dispatch Office: o (1) Water Closet o (1) Shower o (1) Lavatory o (1) Floor Drain o (1) Floor Sink for Condensate o (1) Break Room Sink o (1) Electric Water Heater 20 gallon o (1) Circulation Pump o (1) Thermostatic Mixing Valve o Piping Systems Required Include: ▪ Underground & above ground waste and vent ▪ Trap primer piping for floor sink ▪ Insulated domestic hot water ▪ Domestic Cold Water ▪ Condensate from IT fan coil • Men’s Locker/Restroom Area: o Upgrade fixtures. Assume replacing carriers. o (3) Water Closets o (1) Urinal o (2) Lavatories o (2) Showers • Women’s Locker/Restroom Area: o (2) Water Closets o (2) Lavatory o (1) Shower o (1) Floor Drain o Piping Systems Required Include: Boneso Plumbing & Mechanical. 2758 Concrete Ct. Paso Robles CA 93446 (805) 227-4450 • (805) 227-4502 Fax ▪ Underground & above ground waste and vent ▪ Insulated domestic hot water ▪ Domestic cold water ▪ Trap primer piping Clarifications: • Supplemental steel for duct, and pipe trapeze hangers are by structural steel contractor, for horizontal and wall applications. • All refrigeration piping to the BC controllers will be ACR, all piping from BC controllers to fan coils will be pre-insulated soft copper. • No low voltage conduit The Alternate to replace the existing eight (8) gas fired make up air units on PD was not accepted and the existing units and ducting will remain as is. We cannot guarantee these units and the original warranty is no longer valid. If it is determined in the future to do this work then we can review and a current ROM would be an add of $390,000.00. Exclusions: HVAC • Escalation costs Exclusions: Plumbing • Permits and fees of any kind • Controls programming • Testing or inspections • IAQ plan • Backing, Blocking, or Block-outs will be by F&H / framing subcontractor • Removal of excavation spoils from sites will be complete by F&H or earthwork subcontractor • Sand oil interceptor to be by others • Site utilities to be by other subcontractors • New SCBA Equipment (existing equipment to be salvages, stored and replaced) • Backflow preventers for new services to be by site utility subcontractors ATASCADEROPUBLICSAFETY-FIRESTATION101/20/2025SanLuisObispo,CA93406P.O.Box1167-3562EmpleoSt.THOMAELECTRIC,INC.Phone:(805)543-3850cad@thomaelec.comFax:(805)543-3829ThesedrawingsandspecificationswerepreparedbyThomaElectricspecificallyforthisdesign/buildprojectandshallnotbeusedforbiddingpurposesand/orconstructionbyothers.AlldesignsandinformationshownonthedrawingsareinstrumentsofserviceandarethepropertyofThomaElectric,Inc.Visualcontactwiththeseplansandspecificationsshallconstituteprimafacieevidenceoftheacceptanceoftheserestrictions.FIRESTATION1ELECTRICALGENERALNOTES1. REFERTOARCHITECTURALCODESHEETFORFIXTURETYPEROCCUPANCYSPACES.2. ARC-FAULTCIRCUIT-INTERRUPTERPROTECTIONSHALLBEPROVIDEDASREQUIREDIN210.12(A),(B),AND(C).THEARC-FAULTCIRCUITINTERRUPTERSHALLBEINSTALLEDINAREADILYACCESSIBLELOCATION.ALL120VOLT,SINGLEPHASE15AND20AMPEREBRANCHCIRCUITSSUPPLYINGOUTLETSINSTALLEDINDWELLINGUNITKITCHENS,FAMILYROOMS,DININGROOMS,LIVINGROOMS,PARLORS,LIBRARIES,DENS,BEDROOMS,SUNROOMS,RECREATIONROOMS,CLOSET,HALLWAYS,LAUNDRYAREASORSIMILARROOMSORAREASSHALLBEPROTECTEDBYALISTEDARC-FAULTCIRCUITINTERRUPTER,COMBINATIONTYPE,INSTALLEDTOPROVIDEPROTECTIONOFTHEBRANCHCIRCUIT(CEC210-12(A).3. ALLELECTRICALOUTLETSINSTALLEDINBATHROOMS,GARAGES,BASEMENTS,CRAWLSPACES,OUTDOORS,KITCHENCOUNTERS,ANDATWETBARSINKSSHALLHAVEGROUND-FAULTCIRCUIT-INTERRUPTERPROTECTIONINCOMPLIANCEWITHNECArt.210-8,CONSISTINGOF125VOLT,SINGLE-PHASE,15-AND20-AMPERERECEPTACLES.4. ALLRECEPTACLEAPPLIANCEEQUIPMENTSHOWNONPLANSMUSTBECOORDINATEDWITHARCHITECTELEVATIONANDMANUFACTURER'SREQUIREMENTSPRIORTOROUGH-IN.5. EACHMULTI-WIREBRANCHSHALLBEPROVIDEDWITHAMEANSTHATWILLSIMULTANEOUSLYDISCONNECTALLUNGROUNDEDCONDUCTORSATTHEPOINTWHEREBRANCHCIRCUITORIGINATES(ARTICLECEC210.4)6. ALLBATHROOMRECEPTACLEOUTLETSSHALLBESUPPLIEDBYAMINIMUMOFONE20-AMPEREBRANCHCIRCUIT,SUCHCIRCUITSSHALLHAVENOOTHEROUTLETS.THISDEDICATEDCIRCUITMAYSERVICEMORETHANONEBATHROOM.NECART.210-52(d).RECEPTACLESSHALLBEADJACENTTOANDWITHIN36"OFTHEOUTSIDEEDGEOFEACHBASIN.7. ALL125V,15AMPSAND20AMPRECEPTACLEINDWELLINGUNITSSHALLBETAMPER-RESISTANTPERCEC406.12.8. RECESSEDLUMINAIRESINSTALLEDINAREASTORECEIVEINSULATIONSHALLBE"IC"LUMINARIESANDARECERTIFIEDANDLABELEDASAIRTIGHTTOTHESTANDARDSPRESCRIBEDBYTHERESIDENTIALENERGYCODE.9. RECESSEDLIGHTFIXTURESINSTALLEDINAFIRERATEDASSEMBLYSHALLBEINSTALLEDPERTHEAPPROVEDLISTINGORPROTECTEDBYANAPPROVEDMETHOD.10. BATHROOMRECEPTACLESMUSTBEONA20AMP,CIRCUIT(ORCIRCUITS)WITHNOOTHEROUTLETS.11. CEILING-SUSPENDED(PADDLE)FANS(IFSHOWN)SHALLBESUPPORTEDINDEPENDENTLYOFANOUTLETBOXORBYLISTEDOUTLETBOXOROUTLETBOXSYSTEMSIDENTIFIEDFORTHEUSEANDINSTALLEDINACCORDANCEWITHCEC314-27(D),CEC422-18.PROVIDEBOXFORFUTUREPADDLEFANINBEDROOMSIFNOTSHOWNONPLANS.12. ALLLUMINAIRESANDLAMPHOLDERSSHALLBELISTEDCEC410-6.13. HIGHEFFICACYLUMINAIRESOTHERTHANOUTDOORHIDLIGHTINGCONTAINONLYHIGHEFFICACYLAMPSASOUTLINEDINTABLE150-COFTHERESIDENTIALENERGYCODEANDNOTCONTAINAMEDIUMSCREWBASESOCKET.14. LIGHTSINBATHROOMS,GARAGES,LAUNDRYROOMS,ANDUTILITYROOMSMUSTBEHIGHEFFICACY,CONTROLLEDBYADIMMERORCONTROLLEDBYAMANUAL-ONOCCUPANTSENSOR.15. PROVIDEA120VRECEPTACLEANDLIGHTNEARTHEFAUWITHALIGHTSWITCHLOCATEDINTHEATTICACCESS.16. PUSHBOTTOMATFRONTDOORSHALLBE+/-12"FROMDOORJAMB.VERIFYLOCATIONWITHDOORTRIM.17. EACHMULTIWIREBRANCHCIRCUITSHALLBEPROVIDEDWITHAMEANSTHATWILLSIMULTANEOUSLYDISCONNECTALLUNGROUNDEDCONDUCTORATTHEPOINTWHERETHEBRANCHCIRCUITORIGINATES.CEC2104(B)18. STEELELECTRICALBOXESLESSTHANOREQUALTO16SQUAREINCHESCANPENETRATEMEMBRANESOFWALLSWITHUPTOA2HOURRATINGPROVIDEDTHEYARESEPARATEDFROMSUCHPENETRATIONSONTHEOPPOSITESIDEOFTHEWALLBYEITHER24INCHES,ADISTANCEEQUALTOTHEDEPTHOFTHEWALLIFFILLEDWITHCELLULOSELOOSEFILL/ROCKWOOL/MINERALWOOL,SOLIDFIREBLOCKING,ORLISTEDPUTTYPADS(CBC714.3.2)19. PENETRATIONSOFFIRE-RESISTIVEWALLS,FLOOR-CEILINGSSHALLBEPROTECTEDASREQUIREDINCBCSECTIONS714.3&714.4.20. INBATHROOMS,GARAGES,LAUNDRYROOMS,ANDUTILITYROOMSATLEASTONELUMINAIREINEACHOFTHESESPACESSHALLBECONTROLLEDBYAVACANCYSENSOR.(CEC150.0)1. CODECOMPLIANCE:ALLWORKSHALLCONFORMTOANDBEPERFORMEDINACCORDANCEWITHCODES,STANDARDS,ANDORDINANCESASSETFORTHBYTHEAUTHORITIESHAVINGJURISDICTIONANDTHEIRLATESTADOPTEDEDITIONS(INEFFECTATTIMEOFBUILDINGPERMITAPPLICATION)OFTHEFOLLOWINGPUBLICATIONS:A. CALIFORNIACODEOFREGULATIONSTITLE24;INCLUDES2022CALIFORNIAELECTRICALCODE,2022CALIFORNIAFIRECODE,2022CALIFORNIABUILDINGCODE,ETC.WITHLOCALAMENDMENTSASAPPLICABLE.B. AMERICANSWITHDISABILITIESACT(ADA).2. SAFETY:THEELECTRICALCONTRACTORISRESPONSIBLETOMAINTAINALLEQUIPMENTINASAFEANDRESPONSIBLEMANNER.KEEPDEADFRONTEQUIPMENTINPLACEWHILEEQUIPMENTISENERGIZED.CONDUCTALLCONSTRUCTIONOPERATIONSINASAFEMANNERFOREMPLOYEESASWELLASOTHERWORKPERSONSORANYONEVISITINGTHEJOBSITE.PROVIDEBARRIERS,FLAGS,TAPE,ETC.ASREQUIREDFORSAFETY.THECONTRACTORSHALLHOLDALLPARTIESHARMLESSOFNEGLIGENTSAFETYPRACTICES,WHICHMAYCAUSEINJURYTOOTHERSONORNEARTHEJOBSITE.3. FIRERATEDASSEMBLIESSHALLMAINTAINRATINGSASSPECIFIEDINTHECALIFORNIABUILDINGCODECHAPTER7.CONTRACTORSHALLPROVIDEANDINSTALLPHYSICALENCLOSUREAROUNDFIXTURES,PANELS,ETC.ASREQUIRED.ALLASSEMBLIESTOBEPENETRATEDSHALLBEINSTALLEDWITHAPPLICABLETHROUGH-PENETRATIONFIRESTOPSYSTEMASDETERMINEDBYULCLASSIFICATION.BEFORECONSTRUCTION,VERIFYANDCOMPLYWITHREQUIREMENTSOFLOCALAUTHORITYHAVINGJURISDICTION.4. MOUNTINGHEIGHTSSHALLBEASFOLLOWSUNLESSOTHERWISENOTED:+15"AFF:RECEPTACLES,TELEPHONE,TV&DATAOUTLETS.(MEASUREDBOTTOMOFOUTLETBOX)+46"AFF:OUTLETABOVECOUNTER(MEASUREDTOPOFOUTLETBOX)+48"AFF:LIGHTSWITCHES.(MEASUREDTOPOFOUTLETBOX)+48"AFF:FIREALARMMANUALPULLSTATIONS,T-STATS.(MEASUREDTOPOFOUTLETBOX)THELOWEROF+80"AFFTOBOTTOMOFLENS,OR6"BELOWCEILING:FIREALARMVISUALS.ELECTRICALSWITCHES:CONTROLSANDSWITCHESINTENDEDTOBEUSEDBYTHEOCCUPANTOFTHEROOMORAREATOCONTROLLIGHTANDRECEPTACLEOUTLETS,APPLIANCESORCOOLING,HEATINGANDVENTILATINGEQUIPMENT,SHALLBELOCATEDNOMORETHAN48INCHESMEASUREDFROMTHETOPOFTHEOUTLETBOXNORLESSTHAN15INCHESMEASUREDFROMTHEBOTTOMOFTHEOUTLETBOXTOTHELEVELOFTHEFINISHFLOORORWORKINGPLATFORM.[CBC11B-308.1.1]ELECTRICALRECEPTACLEOUTLETS:ELECTRICALRECEPTACLEOUTLETSONBRANCHCIRCUITSOF30AMPERESORLESSANDCOMMUNICATIONSYSTEMRECEPTACLESSHALLBELOCATEDNOMORETHAN48INCHESMEASUREDFROMTHETOPOFTHERECEPTACLEOUTLETBOXORRECEPTACLEHOUSINGNORLESSTHAN15INCHESMEASUREDFROMTHEBOTTOMOFTHERECEPTACLEOUTLETBOXORRECEPTACLEHOUSINGTOTHELEVELOFTHEFINISHFLOORORWORKINGPLATFORM[CBC11B-308.1.2]CONTROLSANDOPERATINGMECHANISMSSHALLCOMPLYWITHTHEREQUIREMENTSOFSECTION11B-309.BEFOREROUGH-IN,VERIFYALLMOUNTINGHEIGHTSANDEXACTLOCATIONSFORALLEQUIPMENTELECTRICALCONNECTIONS,STUB-UPS,RECEPTACLES,OUTLETS,ETC.WITHARCHITECTOROWNER.PLACEDEVICESLOCATEDABOVECOUNTERS,SHELVING,ETC.ANDINBATHROOMSSOASNOTTOCONFLICTWITHEDGESOFWAINSCOTING,COUNTERSPLASH,SHELVING,ETC.ARCHITECTURALSHEETSSHALLGOVERN.5. EQUIPMENTANCHORAGENOTEALLMECHANICALANDELECTRICALEQUIPMENTSHALLBEANCHOREDORBRACEDTOMEETTHEHORIZONTALANDVERTICALFORCESPRESCRIBEDINTHE2016CBC,SECTION1614A.1.13ANDASCE7-05SECTIONS13.3,13.4&13.6.THEATTACHMENTOFTHEFOLLOWINGITEMSSHALLBEDESIGNEDTORESISTTHEFORCESPRESCRIBEDABOVE,BUTNEEDNOTBEDETAILEDONTHEPLANS:A. EQUIPMENTWEIGHINGLESSTHAN400POUNDSSUPPORTEDDIRECTLYONTHEFLOORORROOF.B. FURNITUREREQUIREDTOBEATTACHEDINACCORDANCEWITHPART2,TITLE24,C.C.R..C. TEMPORARYORMOVABLEEQUIPMENT.D. EQUIPMENTWEIGHINGLESSTHAN20POUNDSSUPPORTEDBYVIBRATIONISOLATORS.E. EQUIPMENTWEIGHINGLESSTHAN20POUNDSSUSPENDEDFROMAROOFORFLOORORHUNGFROMAWALL.FORTHOSEELEMENTSTHATDONOTREQUIREDETAILSONTHEAPPROVEDDRAWINGS,THEINSTALLATIONSHALLBESUBJECTTOTHEAPPROVALOFTHEMECHANICAL/ELECTRICALENGINEER.PIPING,DUCTWORK,ANDELECTRICALDISTRIBUTIONSYSTEMBRACINGNOTEPIPING,DUCTWORK,ANDELECTRICALDISTRIBUTIONSYSTEMSSHALLBEBRACEDTORESISTTHEFORCESPRESCRIBEDINASCE7-05SECTION13.3ASDEFINEDINASCE7-05SECTION13.6.8,13.6.7,AND13.6.5.5,ITEM6,RESPECTIVELY.A. FUSING:ALLFUSIBLESAFETYDISCONNECTSWITCHESSHALLBEPROVIDEDWITHDUAL-ELEMENTTIMEDELAYTYPEFUSESSIZEDANDRATEDPEREQUIPMENTMANUFACTURERS'RECOMMENDATIONS.VERIFYWITHEQUIPMENTNAMEPLATEBEFOREINSTALLATION.B. INSTALLSEPARATENEUTRALSFOREACH120VBRANCHCIRCUIT.C. MOTOROVERLOADPROTECTION:WHEREREQUIREDBYNECARTICLE430PARTCANDNOTSHOWNONPLANORPROVIDEDINTEGRALWITHEQUIPMENT,PROVIDEANDINSTALLTHERMALOVERLOADPROTECTIONFORALLMOTORS.D. SPARECONDUITFORRECESSEDPANELS:PROVIDE(1)3/4"SPARECONDUITSTUBUPTOACCESSIBLEABOVECEILINGSPACEAND/ORACCESSIBLESPACEBELOWFOREVERY(3)SPAREBREAKERSPACESASINDICATEDONPANELSCHEDULES.E. DEVICELOCATIONSSHOWNARESCHEMATICANDAPPROXIMATE.EXACTLOCATIONSSHALLBEFIELDVERIFIEDDURINGROUGH-INWITHARCHITECTURALELEVATIONS,CASEWORKSHOPDRAWINGS,FURNITURE,ETC.ANDSHALLBECOORDINATEDWITHOTHERTRADESTOAVOIDCONFLICTWITHOTHEREQUIPMENT.F. ELECTRICALANDCOMMUNICATIONSOUTLETSSHOWNINTHESAMELOCATION,SHALLBEMOUNTEDONOPPOSITESIDESOFTHESAMESTUD.COORDINATEBETWEENELECTRICALANDCOMMUNICATIONSPLANS.G. ALLNEWOUTLETSMUSTBETAMPERPROOF.H. ALL15AND20AMPERERECEPTACLESFORBOTHDAMPANDWETLOCATIONSREQUIREDTOBELISTEDWEATHER-RESISTANT(WR)TYPEPERCEC406.9.I. ALLGFCIPROTECTIONMUSTBEREADILYACCESSIBLE.J. GFCIPROTECTRECEPTACLESINWETLOCATIONMUSTBEFURNISHEDWITHANEXTRADUTYHOODCOVERPERCEC406.9(B)A. NIGHTLIGHT"NL"DESIGNATEDLUMINAIRESININTERIORLOCATIONSSHALLHAVEONEBALLASTCONTINUOUSLYENERGIZED.LUMINAIRESINEXTERIORLOCATIONSSHALLBEAUTOMATICALLYCONTROLLEDTOBEONFROMDUSKTODAWN.B. LIGHTINGFIXTURELOCATIONSSHOWNARESCHEMATIC.REFERTOARCHITECTURALPLANS(REFLECTEDCEILING,ELEVATIONS,ETC.)FOREXACTLOCATIONSANDMOUNTINGHEIGHTSPRIORTOROUGH-IN.C. REFERTOARCHITECT'SREFLECTEDCEILINGPLAN(S)FORCEILINGHEIGHTS,TYPES,FINISHES,ETC.INEACHAREA.VERIFYFLANGETYPES,TRIMKITS,STEMLENGTHS,ETC.FORALLFIXTURESPRIORTOSUBMITTALS.D. CONFIRMLOCATIONOFALLDOORSSWINGSWITHARCHITECTURALPLANSPRIORTOROUGH-INOFSWITCHES.E. PROVIDEUNSWITCHEDHOTLEGOFROOMLIGHTINGBRANCHCIRCUITTOEACHBATTERYPOWEREDEMERGENCYLIGHTANDEXITSIGNFORCONTINUOUSCHARGING.LIGHTINGFLOORPLANNOTESRATEDWALLS/ASSEMBLIESNOTESPOWERFLOORPLANNOTES1. INFIRE-RESISTANCERATEDWALLS,DETAILTHROUGHPENETRATIONSANDMEMBRANEPENETRATIONPERCBC714.4ASNOTEDBELOW:A. STEEL,FERROUSORCOPPERPIPESMAYPENETRATEFIRE-RESISTANCERATEDWALLS,PROVIDEDTHEOPENINGISPROTECTEDASFOLLOWS:(CBC714.4.1)i. TEMPENETRATINGCONCRETEORMASONRYWALLSISAMAXIMUM6INCHESNOMINALDIAMETERANDTHEAREAOFTHEOPENINGTHROUGHTHEWALLDOESNOTEXCEED144SQUAREINCHES,CONCRETE,GROUTORMORTARISPERMITTEDWHEREITISINSTALLEDTHEFULLTHICKNESSOFTHEWALLORTHETHICKNESSREQUIREDTOMAINTAINTHEFIRE-RESISTANCERATING;ORii. WHENTHEANNULARSPACEISPROTECTEDWITHMATERIALTHATMEETSASTME119ORUL263.B. PENETRATIONSSHALLBEFIRE-STOPPEDBYASYSTEMINSTALLEDASTESTEDINACCORDANCEWITHASTME814ORUL1479,ANDSHALLHAVEANFRATINGOFNOTLESSTHANTHEREQUIREDFIRE-RESISTANCERATINGOFTHEWALLPENETRATED.(CBC714.4.1.2)C. MEMBRANEPENETRATIONSOFMAXIMUM2-HOURFIRE-RESISTANCERATEDWALLSBYSTEELELECTRICALBOXESAREPERMITTED,PROVIDEDTHATEACHDOESNOTEXCEED16SQUAREINCHESINAREAANDTHETOTALAREAOFSUCHOPENINGDOESNOTEXCEED100SQUAREINCHESFORANY100SQUAREFEETOFWALLAREA,ANDTHESPACEBETWEENTHEWALLMEMBRANEANDTHEBOXDOESNOTEXCEED1/8INCH.ADDITIONALLY,OUTLETBOXESONOPPOSITESIDESOFTHEWALLSHALLBESEPARATEDBYAHORIZONTALDISTANCEOFNOTLESSTHAN24INCHES(CBC714.4.2EXCEPTION1).D. MEMBRANEPENETRATIONSBYLISTEDELECTRICALBOXESOFANYMATERIALAREPERMITTED,PROVIDEDSUCHBOXESHAVEBEENTESTEDFORUSEINFIRE-RESISTANCERATEDASSEMBLIES,ANDTHESPACEBETWEENTHEWALLMEMBRANEANDTHEBOXDOESNOTEXCEED1/8INCHUNLESSLISTEDOTHERWISE.ADDITIONALLY,OUTLETBOXESONOPPOSEDSIDESOFTHEWALLSHALLBESEPARATEDBYAHORIZONTALDISTANCEOFNOTLESSTHAN24INCHES.(CBC714.4.2EXCEPTION2)E. AFIRESPRINKLERSHALLBEPERMITTEDTOBEUNPROTECTEDPROVIDEDSUCHSPACEISCOVEREDBYAMETALESCUTCHEONPLATE.(CBC714.4.2EXCEPTION5)F. WHEREWALLSAREPENETRATEDBYOTHERMATERIALSOROPENINGSLARGERTHANTHOSEMENTIONEDABOVE,THEYMUSTBEQUALIFIEDBYTESTINACCORDANCEWITHCBC714.4.2EXCEPTION2.2. INFIRE-RESISTANCEHORIZONTALASSEMBLIES,DETAILTHROUGHPENETRATIONSANDMEMBRANEPENETRATIONPERCBC714.5ASNOTEDBELOW:A. STEEL,FERROUSORCOPPERCONDUITSMAYPENETRATEFIRE-RESISTANCERATEDFLOORASSEMBLYWHENTHEANNULARSPACEISPROTECTEDWITHMATERIALTHATMEETSASTME119ORUL263(CBC714.5.1EXCEPTION1)B. PENETRATINGITEMS,ASNOTEDABOVE,WITHAMAXIMUM6INCHESNOMINALDIAMETERSHALLNOTBELIMITEDTOTHEPENETRATIONOFASINGLEFIRE-RESISTANCERATEDFLOORASSEMBLY,PROVIDEDTHATTHEAREAOFTHEOPENINGSDOESNOTEXCEED144SQUAREINCHESINANY100SQUAREFEETOFFLOORAREA.(CBC714.4.1.1EXCEPTION1)C. PENETRATIONSSHALLBEFIRE-STOPPEDBYASYSTEMINSTALLEDASTESTEDINACCORDANCEWITHASTME814ORUL1479.THESYSTEMSHALLHAVEANFRATINGANDTRATINGOFNOTLESSTHAN1-HOURBUTNOTLESSTHANTHEREQUIREDFIRE-RESISTANCERATINGOFTHEFLOORPENETRATED(CBC714.5.1)D. MEMBRANEPENETRATIONSBYLISTEDELECTRICALOUTLETBOXESAREPERMITTEDPROVIDEDSUCHBOXESHAVEBEENTESTEDFORUSEINFIRE-RESISTANCERATEDASSEMBLIES,ANDTHESPACEBETWEENTHECEILINGMEMBRANEANDTHEBOXDOESNOTEXCEED1/8INCHESUNLESSLISTEDOTHERWISE.(CBC714.5.2EXCEPTION4)E. AFIRESPRINKLERSHALLBEPERMITTEDTOBEUNPROTECTEDPROVIDEDSUCHSPACEISCOVEREDBYAMETALESCUTCHEONPLATE.(CBC714.5.2EXCEPTION5)3. JOINTSINSTALLEDINORBETWEENFIRE-RESISTANCERATEDWALL,FLOORORFLOOR/CEILINGASSEMBLIESANDROOFSORROOF/CEILINGASSEMBLIESSHALLBEPROTECTEDANAPPROVEDFIRE-RESISTANTJOINTSYSTEMWITHAFIRE-RESISTANCERATINGNOTLESSTHANTHATOFTHEASSEMBLYINWHICHITISINSTALLED.PROVIDEDETAILS(CBC7145.1)4. FIREDOORSANDFIRE-PROTECTIONRATEDGLAZINGSHALLBEARLABELSASREQUIREDBYCBC716.2.9AND716.3.5.5. FIREDAMPERSSHALLBETHEMINIMUMFIREPROTECTIONRATINGSPECIFIEDINCBCTABLE717.3.2.1FORTHETYPEOFPENETRATION(CBC717.3.2.1)REFERTOSPECIFICATIONS260519FORADDITIONALINFORMATION.1. WIRECONNECTORSSHALLBEMINIMUM75DEGREECENTIGRADERATEDANDPROPERLYSIZEDFORTHENUMBEROFCONDUCTORSBEINGCONNECTED,TERMINATED,SPLICED,ETC.ALLABOVEGRADECONNECTORSSHALLBESOLDERLESSLUGORPLASTICWIRENUTTYPE,SCREWON,PRESSURECABLETYPE(WIREUTORSPRINGNUTTYPE)600VOLT,105DEGREEC,WITHSKIRTTOCOVERALLPORTIONSOFSTRIPPEDWIRES.CONNECTORSHALLBEU.L.RATEDFORNUMBERANDSIZEOFCONDUCTORSBEINGJOINEDTOGETHERASSPLICED.2. WIRESANDCABLESFORLINEVOLTAGESYSTEMANDCONTROLS.WIREANDCABLESHALLBECOPPER,600VOLTRATEDTHROUGHOUT.CONDUCTORS14AWGOT10AWG,SOLIDORSTRANDED.CONDUCTORS8AWGANDLARGER,STRANDED3. ALLCONDUCTORSSHALLBECOPPERUNLESSOTHERWISENOTED.MINIMUMSIZEFORINDIVIDUALCONDUCTORSSHALLBE#12AWGUNLESSOTHERWISENOTEDONPANELSCHEDULEORPLANS.SIZE#8AWGANDLARGERSHALLBESTRANDEDCONDUCTOR.INDIVIDUALCONDUCTORSSHALLBEINSULATEDWITHTYPE,XHHW,THW,THHN/THWN600VOLTINSULATIONUNLESSOTHERWISENOTED.4. PROPERINSULATIONTYPESHALLBEUSEDFORTHEPROPERENVIRONMENTALAPPLICATION(I.E.WATERPROOF,WETLOCATION,PLENUMTEMPERATURERATED).ALLCONDUCTORS,WIRINGCABLEWHEREINSTALLEDBELOWFLOOR,SLABORUNDERGROUNDSHALLBECONSIDEREDWETLOCATIONS,ANDSHALLBERATEDACCORDINGLY.NONWATERPROOFCABLINGISNOTALLOWEDINANYBELOWGRADEORWETAPPLICATION.CONDUITSYSTEMSUSEDONTHISPROJECTSHALLBEASFOLLOWS1. PVCSCHEDULE40-underground/belowslabwithGRSelbowsandriserstapewrapped).2. ELECTRICALMETALLICCONDUIT(EMT)-abovegrade/slabinbuildingconstructionandwhereexposedabove8'-0"aff.3. GALVANIZEDRIGIDSTEEL(GRS)-whereexposedbelow8'-0"aff.and/orwheresubjecttophysicaldamage.4. FLEXIBLESTEELCONDUIT-aboveceilingsand/orconcealedinbuildingconstruction(sealtightflexrequiredinexteriorlocations).5. MCCABLEISALLOWED6. ENTISALLOWEDFORLOWVOLTAGESYSTEMSREFERTOSECTION260533&260500OFSPECIFICATIONSFORADDITIONALINFORMATION.CONDUITSSHALLBEMINIMUM3/4"UNLESSOTHERWISENOTEDORCODEREQUIRESLARGERSIZE,1"FORALLHOMERUNCONDUITSANDWHEREROUTEDBELOWSLABORUNDERGROUND.CONDUITSIZES,WHERENOTNOTEDONTHEDRAWINGS,SHALLBESIZEDFORMAXIMUM40%FILLPERCEC310-6.A. PROVIDESEALTITEPOWER&CONTROLCONNECTIONSTOALLACUNITS.B. ALLEQUIPMENTSHOWNABOVEROOFISNEMA3R.C. VERIFYEXACTEQUIPMENTLOCATIONSANDPOINTSOFCONNECTIONWITHMECHANICALCONTRACTORPRIORTOROUGH-IN.D. CONDUITSHOWNISROUTEDINCEILINGSPACEBELOWROOFDECK.E. NOROOFMOUNTCONDUITISALLOWEDUNLESSOTHERWISENOTED.F. FUSEDISCONNECTSWITCHESPEREQUIPMENTNAMEPLATERATING.G. ALLROOFPENETRATIONSSHALLBEMADEWITHROOFJACKS.SEALINGOFALLROOFPENETRATIONSSHALLBEBYTHEROOFINGCONTRACTOR.H. GFCIPROTECTSERVICERECEPTACLESWITHEXTRADUTYCOVERSMUSTBEINSTALLEDWITHIN25FEETOFEQUIPMENT,PERCEC210.63ANDCMC301.4CONDUCTORSANDCABLESROOFPLANNOTESTYPICALDWELLINGUNITNOTESFIREALARMSYSTEM1. PROVIDEALLWORKANDMATERIALREQUIREDFORACOMPLETEANDOPERATINGFIREALARMSYSTEM.WORKSHALLINCLUDE(BUTNOTBELIMITEDTO):A. SHOPDRAWINGSB. SUBMITTALFORAPPROVALC. COMPLETEINSTALLATIONANDTESTINGD. SYSTEMTRAININGFOROWNER'SREPRESENTATIVEE. WARRANTY2. SUBMITASEPARATESETOFDETAILEDFIREALARMPLANS,SPECIFICATIONSANDENGINEERINGCALCULATIONSINCLUDINGBUTNOTNECESSARILYLIMITEDTO:A. CSFMLISTING#'SANDMANUFACTURERMODEL#'SFOREVERYSYSTEMCOMPONENT WHICHISTOBEINTERCONNECTEDASAPARTOFTHISPROJECT.B. SINGLELINE,RISERANDPOINTTOPOINTWIRINGDIAGRAMSINCLUDINGBATTERYAND VOLTAGEDROPCALCULATIONSFORTHEENTIRESYSTEM.C. INDICATIONOFCONDUCTORTYPE(S),POWER-LIMITEDORNON-POWER-LIMITEDSYSTEM.D. SCALEDELEVATIONOFREMOTEGRAPHICANNUNCIATORPANELATENTRY(IFREQUIRED).E. LISTOFPROPOSEDZONESFORALLINITIATINGDEVICES.F. MATRIXOFSYSTEMOPERATION.G. INFORMATIONASREQUIREDTODEMONSTRATECOMPLIANCEWITHAPPLICABLECODE(S)ANDGAINAPPROVALOFAUTHORITY(IES)HAVINGJURISDICTION.FIREALARMSYSTEMINSTALLATIONSHALLNOTBEGINUNTILSEPARATEPERMITHASBEENOBTAINEDANDALLOFTHEABOVEHASBEENACCEPTEDANDSIGNEDBYTHEAUTHORITY(IES)HAVINGJURISDICTIONANDTHEARCHITECT.AFTERCONSTRUCTION,PROVIDEACCURATEFIELDRECORDDRAWINGSTOOWNER.3. ASAMINIMUM,UNLESSOTHERWISENOTED,FIREALARMCONTROLPANELSHALLBEPROVIDEDWITHBATTERYBACKUP,4ZONESAND1SIGNALCIRCUITWITHPROVISIONSFORFUTUREEXPANSION.PROVIDEWITHDIALER(DACT)ANDCONNECTTOCOMMUNICATIONSSYSTEMWITH(2)DEDICATEDVOICELINESASREQUIREDTOSENDSEPARATEANDDISTINCTSIGNALS(ASREQUIREDBYTHEFIREDEPARTMENT)TOANAPPROVEDCENTRALSTATION.FIRESPRINKLERRISERWATERFLOWAND/ORVALVETAMPERSWITCHESSHALLBEPROVIDEDANDINSTALLEDBYTHESPRINKLERSYSTEMCONTRACTOR,ANDWIREDBACKTOTHEFACPBYTHEFIREALARMCONTRACTOR.COORDINATEFORPROPERVOLTAGE.ALLFIREALARMCOMPONENTSSHALLBECALIFORNIASTATEFIREMARSHALLISTED.4. DUCTSMOKEDETECTORSSHALLBEPROVIDEDBYELECTRICALCONTRACTORANDINSTALLEDBYMECHANICALCONTRACTOR.DETECTORPOWERANDSUPERVISORYWIRINGANDCONNECTIONSSHALLBEMADEBYELECTRICALCONTRACTOR.MECHANICALUNITCONTROL(SHUTDOWNUPONDETECTORALARM)WIRINGANDCONNECTIONSSHALLBEMADEBYMECHANICALCONTRACTOR.FIREALARMSYSTEMGENERATORPOWERSYSTEMA. ITSHALLBETHECONTRACTOR'SRESPONSIBILITYTOCONTACTANDCOORDINATEWITHTHESERVINGUTILITYTOENSUREALLSERVINGUTILITYREQUIREMENTSAREMET.B. ALLSWITCHES,CIRCUITBREAKERSANDOTHEREQUIPMENT,ASSPECIFIED,SHALLHAVETERMINATIONPROVISIONSLISTEDANDIDENTIFIEDFORUSEWITH75DEG.CONDUCTORS,ANDALLFEEDERCONDUCTORS,ANDCONDUITS,ARESIZEBASEDONUSEOF75DEG.CCOPPERWIRESTYPESHWN/THHN.C. ALLEQUIPMENTSHALLHAVEANAPPROVEDTESTINGLABORATORYLABELATTACHED[UL,CSA,ETC.](CEC110-2).D. THEELECTRICALCONTRACTORISRESPONSIBLEFORSUPPLYINGSWITCHGEARSIZEDTOFITINTHEAVAILABLESPACE.REFERTOARCHITECTURALPLANSFORDIMENSIONALINFORMATIONNOTSHOWNONTHEELECTRICALPLANS.CONTRACTORSHALLSUBMITA1/4"SCALEDRAWINGOFALLSWITCHGEAR,ANDTERMINATIONCABINETSONFLOORPLANWITHSUBMITTAL.E. ALLBOXESANDENCLOSURES(INCLUDINGTRANSFERSWITCHES,GENERATORS,ANDPOWERPANELS)FOREMERGENCYCIRCUITSSHALLBEPERMANENTLYMARKEDSOTHEYWILLBEREADILYIDENTIFIEDASACOMPONENTOFANEMERGENCYCIRCUITORSYSTEM,PERNEC700-9(A).F. EMERGENCYLIGHTINGSYSTEM(GENERATORANDAUTOMATICTRANSFER)ANDEXITLIGHTSSHALLBECHECKEDANDAPPROVEDBYTHEFIREDEPARTMENTBEFORETHEAPPROVALOFTHEFINALPLANS.G. INACCORDANCEWITHCEC110.16.PROVIDEARCFLASHPROTECTIONWARNINGLABELSONEACHSWITCHBOARD,PANELBOARD,ANDTRANSFORMER.LABELSSHALLBEPERANSIZ535.4GUIDELINES.(SEEDETAIL)H. ALLPANELSAREBOLT-ONBREAKERS.LOADCENTERSARENOTPERMITTED.I. PERCALIFORNIATITLE24SECTION130.5,WIRINGPROVISIONSHAVEBEENMADEFORDISAGGREGATIONOFTHEELECTRICALCIRCUITS,THEOPTIONALMETERINGHASNOTBEENPROVIDEDFORTHISPROJECT.J. REFERTOPANELSCHEDULESFORINDIVIDUALBRANCHCIRCUITVOLTAGEDROPANDSINGLELINEDIAGRAMFORFEEDERVOLTAGEDROPCALCULATIONS.K. BRANCHCIRCUIT/FEEDERDISTANCEISSHOWNFORREFERENCEONLYASTHEBASISOFVOLTAGEDROPCALCULATIONS.CONDUCTORDISTANCEASINDICATEDSHALLNOTBEUSEDFORBIDDING/CONSTRUCTIONPURPOSES.SHOULDTHEFEEDERDISTANCEEXCEEDTHELENGTHNOTEDPERINSTALLATIONCONDITIONS,NOTIFYTHEENGINEEROFRECORD.TYPICAL.L. TRANSFORMERMUSTBEGROUNDEDTOTHESAMEGROUNDINGELECTRODESYSTEMOFTHEBUILDINGPERCEC250.30(A)(4)ANDBONDEDPERCEC250.104(D).M. PRIMARYDISCONNECTNOTLOCATEDWITHINSIGHTOFTRANSFORMERMUSTHAVELOCKINGMEANSOATREMOTEDISCONNECTANDALABELATTRANSFORMERDENOTINGDISCONNECTLOCATIONPERCEC450.14N. METALWATERPIPINGSYSTEMQUALIFYINGASAGROUNDINGELECTRODEPERCEC250.52(A)(1)MUSTBEBONDEDWITHIN5FEETOFENTERINGTHEBUILDINGPERCEC250.68(C)(1).O. ALLSWITCHBOARD,SWITCHGEAR,PANELBOARDS,ANDMOTORCONTROLCENTERSSHALLBELOCATEDINDEDICATEDSPACESANDPROTECTEDFROMDAMAGEPERCEC110.26E(1)AND/OR(2).P. SERVICECONDUCTORSARETOBEOUTSIDETHEBUILDINGPERCEC230.6.Q. ACCESSANDWORKINGSPACEMUSTBEPROVIDEDABOUTELECTRICALEQUIPMENTREQUIRINGOPERATIONANDMAINTENANCEPERCEC110.26R. PROVIDEREQUIREDIDENTIFICATIONOFPOWERSOURCESBEIDENTIFIEDONTHETRANSFORMER(S)WITHPERMANENTPLAQUEINDICATIONLOCATIONOFALLOTHERSOURCESPER230.2(E),700.7,701.7AND702.7A. APERMANENTPLAQUESHALLBEPLACEDATTHENORMALSERVICEEQUIPMENTDENOTINGTHETYPE&LOCATIONOFTHEON-SITEEMERGENCYSTANDBYPOWERGENERATOR(CEC700-7A,701-7A,702-7A)THEPLAQUESHALLIDENTIFYTHECONNECTIONOFTHEGROUNDINGELECTRODECONDUCTORWHENTHATCONNECTIONISATALOCATIONREMOTEFROMTHEGENERATOR.(CEC700-7B,701-7B,702-7B).SIGNTOREAD"WARNINGSHOCKHAZARDEXISTSIFGROUNDINGELECTRODECONDUCTORORBONDINGJUMPERCONNECTIONINTHISEQUIPMENTISREMOVEDWHILEALTERNATESOURCE(S)ISENERGIZED.B. THEFOLLOWINGEQUIPMENTSHALLBEULLISTEDASINDICATED:- STATIONARYGENERATORS600VORLESSINNON-HAZARDOUSLOCATIONS-(UL2200)- NONEMERGENCYUNINTERRUPTIBLEPOWERSYSTEMS(UPS)-(UL1778)- EMERGENCYRATEDUNINTERRUPTIBLEPOWERSYSTEMS(UPS)-(UL924)- EMERGENCYLIGHTINGANDPOWEREQUIPMENT(UL924)- TRANSFERSWITCHEQUIPMENT(UL1008)- EMERGENCYRATEDLOWLEVELPATHMARKINGANDLIGHTINGSYSTEMS-(UL1994)D. CONFIRMWIRINGREQUIREMENTSWITHGENERATORANDATSPROVIDER.E. PRELIMINARYATSSETTINGARASFOLLOWS.STARTTIMEDELAY:3SECONDSRETRANSFERTIMEDELAY:5MINUTESSTOPTIMEDELAY:THEFINALATSSETTINGSSHALLBEDETERMINEDBYTESTINGCOMPANY.ATSSERVESENTIREFIRESTATIONFACILITY.SINGLELINEDIAGRAMGENERALNOTESEMERGENCYPOWERSYSTEM1. APERMANENTPLAQUESHALLBEPLACEDATTHENORMALSERVICEEQUIPMENTDENOTINGTHETYPE&LOCATIONOFTHEON-SITEEMERGENCYSTANDBYPOWERGENERATORTHEPLAQUESHALLIDENTIFYTHECONNECTIONOFTHEGROUNDINGELECTRODECONDUCTORWHENTHATCONNECTIONISATALOCATIONREMOTEFROMTHEGENERATOR.(NEC700-7,701-7,702-7).2. FORALLSTANDBYGENERATORSYSTEMS,ASIGNSHALLBEPLACEDATTHESERVICEENTRANCEEQUIPMENTINDICATINGTYPEANDLOCATIONOFON-SITEEMERGENCYPOWERSOURCES,PERCEC701-7(A)/702-7(A).3. WHERETHEGROUNDEDCIRCUITCONDUCTORCONNECTEDTOTHEEMERGENCYSOURCEISCONNECTEDTOAGROUNDINGELECTRODECONDUCTORATALOCATIONREMOTEFROMTHEEMERGENCYSOURCE,THERESHALLBEASIGNATTHEGROUNDINGLOCATIONTHATSHALLIDENTIFYALLEMERGENCYANDNORMALSOURCESCONNECTEDATTHATLOCATION,PERCEC701-7(B)/702-7(B).4. LIGHTINGINVERTERWIRINGFROMANEMERGENCYSOURCEOREMERGENCYSOURCEDISTRIBUTIONOVERCURRENTPROTECTIONTOEMERGENCYLOADSSHALLBEKEPTENTIRELYINDEPENDENTOFALLOTHERWIRINGANDEQUIPMENTANDSHALLBEIDENTIFIEDBYPERMANENTMARKING,EXCEPTASNOTEDIN(1)THROUGH(5),PERCEC700.GENERALNOTESCONDUITSYSTEMSNOTESA. ALL15AND20AMPERERECEPTACLESFORBOTHDAMPANDWETLOCATIONSREQUIREDTOBELISTEDWEATHER-RESISTANT(WR)TYPEPERCEC406.9(A)AND(B)B. CEC406.9(A)RECEPTACLESINDAMPLOCATIONS:RECEPTACLESINSTALLEDOUTDOORSINALOCATIONPROTECTEDFROMTHEWEATHERORINOTHERDAMPLOCATIONSSHALLBEANENCLOSUREFORTHERECEPTACLETHATISWEATHERPROOFWHENTHERECEPTACLEISCOVERED(ATTACHMENTPLUGCAPNOTINSERTEDANDRECEPTACLECOVERSCLOSE)C. CEC406.9(B)RECEPTACLESOF15AND20AMP,125AND250VOLTSINSTALLEDINAWETLOCATIONSHALLHAVEANENCLOSURETHATISWEATHERPROOFWHETHERORNOTTHEATTACHMENTPLUGCAPISINSERTED.ANOUTLETBOXHOODINSTALLEDFORTHISPURPOSESHALLBELISTEDANDSHALLBEIDENTIFIEDAS'EXTRA-DUTY"OTHERLISTEDPRODUCTS,ENCLOSURES,ORASSEMBLIESPROVIDINGWEATHERPROOFPROTECTIONTHATDONOTUTILIZEANOUTLETBOXHOODNEEDTOBEMARKED"EXTRADUTY"EXCEPTION:15AND20AMP,125THROUGH250VOLTRECEPTACLESINSTALLEDINAWETLOCATIONANDSUBJECTTOROUTINEHIGH-PRESSURESPRAYWASHINGSHALLBEPERMITTEDTOHAVEANENCLOSURETHATISWEATHERPROOFWHENTHEATTACHMENTPLUGISREMOVED.RECEPTACLESATDAMPANDWETLOCATIONSHEETINDEXSHEETNO.FIRESTATIONSHEETDESCRIPTIONEF1-001 ELECTRICALGENERALNOTESEF1-002 ELECTRICALLEGENDANDABBREVIATIONSEF1-003 SINGLELINEDIAGRAMEF1S-101 ELECTRICALSITEPLANEF1-101LIGHTINGFLOORPLANEF1-102POWERFLOORPLANEF1-103COMMUNICATIONSFLOORPLANEF1-104FIRESTATIONALERTINGFLOORPLANEF1-105FIREALARMFLOORPLANEF1-201 ENLARGEDELECTRICALPLANSEF1-001CEC 160.5 ATASCADEROPUBLICSAFETY-FIRESTATION101/20/2025SanLuisObispo,CA93406P.O.Box1167-3562EmpleoSt.THOMAELECTRIC,INC.Phone:(805)543-3850cad@thomaelec.comFax:(805)543-3829ThesedrawingsandspecificationswerepreparedbyThomaElectricspecificallyforthisdesign/buildprojectandshallnotbeusedforbiddingpurposesand/orconstructionbyothers.AlldesignsandinformationshownonthedrawingsareinstrumentsofserviceandarethepropertyofThomaElectric,Inc.Visualcontactwiththeseplansandspecificationsshallconstituteprimafacieevidenceoftheacceptanceoftheserestrictions.FIRESTATION1ELECTRICALLEGENDANDABBREVIATIONSPOWERLEGENDNOTE:INTERPRETINCONTEXTMISCELLANEOUSCONDUIT/WIRELIGHTFIXTURESCONVENTIONSLEGEND3103NUMBEREDSHEETNOTES:REFERSTONOTESONSAMESHEETASREFERENCEDETAILREFERENCE:Z=DETAILDESIGNATIONX=SHEETNUMBERREFERENCEZXFEEDERSCHEDULEDESIGNATION(EXAMPLE:3103=310AMPERE,600V,3CURRENTCARRYINGCONDUCTORS,PREFIXES:'M'INDICATESMEDIUMVOLTAGE,'CO14'INDICATESCONDUITONLY,QUANTITY(1)ANDSIZE(4"))XMECHANICALSYSTEMSTAG(REFERTOMECHANICALSHEETS)Y=UNITTYPEX=UNITNUMBERYXCOMBINATIONSTARTERMAGNETICCONTACTORDAMPERMOTORHUMIDISTATSURFACEMOUNTCABINETFLUSHMOUNTCABINETSURFACEMOUNTPANELFLUSHMOUNTPANELPUSHBUTTONHMDMCIRCUITBREAKERFUSIBLESWITCHGROUNDTHERMOSTATSURFACEALETTERADJACENTINDICATES(ARROWINDICATESDIRECTION)FIXTURETYPERECESSEDWALLMOUNTEXITLIGHT-CEILINGEXITLIGHT-WALLWALL-PACKCLOCKPHASEØTMOTORUPLIGHT-FLUSHINGRADEPOLELIGHT-DECORATIVEPENDANTLINEARUNDERCABINETLIGHTTANDEM-WIREDLAMPSBOLLARDSTRIPUONDIRECTIONALFLOODEMERGENCYFIXTUREPOLELIGHTTRACKLIGHTCEILINGSURFACEMOUNTWALLSURFACEMOUNTRECESSEDDOWNLIGHTRECESSEDWALLWASHRECESSEDPENDANTMOUNT(E)POWERHOMERUNINDICATESLINECONTINUESWIRELINE-CONTINUESCONDUITSTUB(W/MARKER)VERTICALCONDUITRUNFLEXIBLECONNECTIONSURFACEMOUNTRACEWAYCORDW/PLUGLOWVOLTAGELVCONDUITSEALNEWPOWERHOMERUN(3HOTS&NEUTSHOWN)ISOLATEDGROUNDEXISTINGTOREMAINNEWEUNDERGROUNDWALLMOUNTEDCLOCKCLOCK/SPEAKERCOMBINATIONSSAFETYDISCONNECTENDOFLINERESISTORCHIMEDUCTSMOKEDETECTORVISUAL-VISUALDEVICEMANUALPULLSTATIONHORN-AUDIBLEDEVICEAUDIBLE/VISUALSMOKEDETECTORHEATDETECTORBELLTAMPERSWITCHTPFLOWSWITCHAVVFHFIREALARMCONTROLPANELREMOTEPOWERSUPPLYRPSSPEAKER/VISUALSVFIREALARMSFDSMOKEFIREDAMPERSDCOSDDSDHBCSMOKEDETECTORWITHCOWALLSURFACEMOUNTLINEARTYPELEDCOVE&UNDERCABINETLIGHTPERFIXTURESCHEDULEJJUNCTIONBOXSDVSMOKEDETECTORWITHVISUALA AMPEREAB AMPBREAKERABAND ABANDONEDABV ABOVEAC ALTERNATINGCURRENTAC-# AIRCONDITIONERADJ ADJACENTAF AMPFUSE,AMPFRAMEAFF ABOVEFINISHFLOORAFG BOVEFINISHGRADEAIC AMPERESINTERRUPTINGCAPACITYAl ALUMINUMAS AMPSWITCHRATINGATS AUTOMATICTIMESWITCHATS AUTOMATICTRANSFERSWITCHAV AUDIBLE/AUDIOVISUALAWG AMERICANWIREGAGEBFG BELOWFINISHGRADEBIL BASICIMPULSELEVELBLDG BUILDINGC CONDUIT-C- CATVCONDUITCAB'T CABINETCATV CABLETELEVISIONCB CIRCUITBREAKER,CODEBLUECBC CA.BUILDINGCODECEC CA.ELECTRICALCODECA.ENERGYCOMMISSIONCF COMPACTFLUORESCENTCFC CALIFORNIAFIRECODECLG CEILINGCL CENTERLINECKT CIRCUITCNT'R CONTRACTORC.O. CONDUITONLY(W/PULLROPE)COND CONDUIT,CONDUCTORCR CRITICALBRANCHCSFM CALIFORNIASFMCT CURRENTTRANSFORMERCu COPPERCU-# CONDENSINGUNITD DEPTHDC DIRECTCURRENTDF DRINKINGFOUNTAINDIA DIAMETERDISC DISCONNECTDIST DISTRIBUTIONDPST DOUBLEPOLESINGLETHROWDW DISHWASHEREM EMERGENCY(E) EXISTINGEA EACHEB ELECTRONICBALLASTEC ELECTRICALCONTRACTOREC-# EVAPORATIVECOOLEREF-# EXHAUSTFANEL EVENINGLIGHTELEC ELECTRICALEM EMERGBATTERYBACKUPEMERGENCYBALLASTEMERG EMERGENCYEOL ENDOFLINEEQUIP'T EQUIPMENTES ENERGYSAVING(EXN) (E)IN(N)LOCATION(EXR) (E)TOBE(R)EXT EXTERIORF FLUORESCENT(F) FUTUREF-# FURNACEFA FIREALARMFACP FIREALARMCONTROLPANELFAT FIREALARMTERMINALFAU FORCEDAIRUNITFBO FURNISHEDBYOTHERSFC-# FANCOILFLA FULLLOADAMPSFLR FLOORFLUOR FLUORESCENTFS FUSIBLESWITCHFVNR FULLVOLTAGENON-REVERSINGG GROUNDINGCONDUCTORGC GENERALCONTRACTORGD GARBAGEDISPOSALGFCI GROUNDFAULTCIRCUITINTERRUPTERGFI GROUNDFAULTCIRCUITINTERRUPTERGND GROUNDGRS GALVANIZEDRIGIDSTEELGWS GANGWITHSWITCHH HEIGHT,HIGHHACR HEATING,AC&REFRIGHID HIGHINTENSITYDISCHARGEHO HIGHOUTPUTHOA HAND-OFF-AUTOhp HORSEPOWERHPF HIGHPOWERFACTORHPS HIGHPRESSURESODIUMIC INTERCOMID IDENTIFICATIONIDF INTERMEDIATEDISTRIBUTIONFRAMEIF INSIDEFROSTIG ISOLATEDGROUNDJ-BOX JUNCTIONBOXk QUANTITY1000kVA KILOVOLTAMPSkW KILOWATTLC LIGHTINGCONTACTORLPS LOWPRESSURESODIUMLRA LOCKEDROTORAMPSLS LIFESAFETYBRANCHLT LIGHTLTG LIGHTINGLV LOWVOLTAGEMC MECHANICALCONTRACTORMCA MINIMUMCKTAMPSMCB MAINCIRCUITBREAKERMCTB MAINCATVTERMINALBOARDMCTC MAINCATVTERMINALCABINETMDF MAINDISTRIBUTIONFRAMEMECH MECHANICALMFR MANUFACTURERMFS MAINFUSIBLESWITCHMH METALHALIDEMLO MAINLUGSONLYMOCP MAXIMUMOCPMPOE MINIMUMPOINTOFENTRYMSB MAINSWITCHBOARDMT MOUNTMTHT MOUNTINGHEIGHTMTS MANUALTRANSFERSWITCHMTTB MAINTELEPHONETERMINALBOARDMTTC MAINTELEPHONETERMINALCABINETMW MICROWAVEN NEUTRAL(GROUNDEDCONDUCTOR)(N) NEWN3R NEMA3RNC NORMALLYCLOSEDNEC NATIONALELECTRICALCODENEMA NAT'LELECMANUFACTURER'SASSOCNIC NOTINCONTRACTNL NIGHTLIGHTNO NORMALLYOPENNPF NORMALPOWERFACTORNTS NOTTOSCALEOC ONCENTEROCP OVERCURRENTPROTECTIONOD OUTSIDEDIAMETEROH OVERHEADOSA OFFICEoftheSTATEARCHITECTOSHPD OFFICEofSTATEWIDEHEALTHPLANNING&DEVELOPMENTOVLD OVERLOADP POLEPA PUBLICADDRESSPB PULLBOXPC PULLCHAINPC PHOTOCELLPC PLUMBINGCONTRACTORph PHASEPNL PANELPOC POINTOFCONNECTION-PP- POWERPRIMARY-PS- POWERSECONDARYPV PHOTOVOLTAIC(R) RELOCATE(D)RECEPTRECEPTACLEREF REFRIGERATORREQ'D REQUIREDRLA RATEDLOADAMPSRM ROOMRMC RIGIDMETALCONDUITRMV REMOVERPLC REPLACERS RAPIDSTARTSC SIGNALCABINETSCC SHORTCKTCURRENTSFM STATEFIREMARSHALSHT SHEETSL SLIMLINE,SWITCHLEGSPEC SPECIFICATIONSPST SINGLEPOLESINGLETHROWSQ SQUARESTR'G STORAGESURF SURFACESVC SERVICESW SWITCHT TRANSFORMER,TERMINAL-T- TELEPHONECONDUIT(TBR) TOBEREMOVEDTC TIMECLOCKTEL TELEPHONETELCO TELEPHONECOMPANYTS TIMESWITCHTSO TIMESWITCHOVERRIDETSP TWISTEDSHIELDEDPAIRTTB TELEPHONETERMINALBOARDTTC TELEPHONETERMINALCABINETTX TRANSFORMERTYP TYPICALTYPSIMTYPICALSIMILARUC UNDERCABINET,UNDERCOUNTERUG UNDERGROUNDUGPS UNDERGROUNDPULLSECTIONUL UNDERWRITERSLABORATORIESUON UNLESSOTHERWISENOTEDUSA UGSVCALERT800-642-2444V VOLTVA VOLTAMPERESVAC VOLTALTERNATINGCURRENTVHO VERYHIGHOUTPUTVOLT VOLTAGEVR VANDAL-RESISTANTW WIDTH,WATT,WIREWH-# WATERHEATERWP WEATHERPROOF(NEMA3R)XFMR TRANSFORMER+48 INDICATESMOUNTINGHEIGHTAFFABBREVIATIONS3-WAYSWITCHSINGLEPOLESINGLETHROW(SPST)SWITCHLIGHTINGPOWERBRANCHCIRCUITLINEVOLTAGECEILINGMOUNTEDOCCUPANCYSENSOR,EXTENDEDRANGE360DEGREES,DUALTECHNOLOGY4-WAYSWITCHNETWORKEDLOWVOLTAGE,DUALTECHNOLOGY,CEILINGMOUNT360°OCCUPANCYSENSOR."C"DENOTESCORNERMOUNT.NETWORKED1-POLEWALLSWITCHWITHDUALTECHNOLOGYOCCUPANCYSENSORANDDIMMINGCONTROLLOWVOLTAGECABLINGPERNETWORKEDSYSTEMREQUIREMENTSNETWORKED0-10VDIMMINGRELAYPACKFORLIGHTFIXTURES.COORDINATEDIMMINGTYPEWITHLIGHTFIXTURE.NETWORKEDRELAYPACKFORCONTROLLEDRECEPTACLESPERT24REQUIREMENTS.LOWVOLTAGECEILINGMOUNTEDOCCUPANCYSENSOR,360DEGREES,DUALTECHNOLOGYNETWORKED2CHANNELSWITCHWITHDIMMINGCONTROLNETWORKEDLOWVOLTAGE,DUALTECHNOLOGY,CEILINGMOUNT360°OCCUPANCYSENSORWITHDAYLIGHTHARVESTING.PROGRAMSENSORTOPROVIDESEPARATECONTROLFORPRIMARYANDSECONDARYDAYLITZONES(ASAPPLICABLE).GENERALLIGHTINGPOWERINASSOCIATEDDAYLITZONESHALLBEREDUCEBYAMINIMUMOF65%.NETWORKED4CHANNELSWITCHWITHDIMMINGCONTROL0-10VORPHASEDIMMINGWALLSWITCH(BASEDONFIXTUREREQUIREMENTS)CEILINGFAN/LIGHTCONTROLWALLSWITCHOCCUPANCYSENSOR,2-BUTTON,DUALTECHNOLOGYWALLSWITCHOCCUPANCYSENSOR,2-BUTTON,PASSIVEINFRAREDNETWORKEDSINGLECHANNELSWITCHWITHDIMMINGCONTROLNETWORKEDAUTOMATICDIMMINGCONTROLPHOTOCELL.SINGLEZONECONTROL.PROGRAMTOPROVIDEDIMMINGCONTROLFORDAYLITZONE.GENERALLIGHTINGPOWERINASSOCIATEDDAYLITZONESHALLBEREDUCEDBYAMINIMUMOF65%.0-10VWALLDIMMINGOCCUPANCYWALLSWITCHNETWORKED0-10VDIMMINGUL924COMPLIANTEMERGENCYRELAYPACKFOREGRESSLIGHTFIXTURES.NETWORKEDPHASEDIMMINGRELAYPACKFORLIGHTFIXTURES.COORDINATEDIMMINGTYPEWITHLIGHTFIXTURE.LINEVOLTAGEPOWERSUPPLYVACANCYSENSORWALLSWITCHNETWORKEDHIGHBAY360DEGREESENSOR.PIROCCUPANCYDETECTION.15MINUTEMAXINTERVALTIMERWALLSWITCHOCCUPANCYSENSOR,SINGLEBUTTON,DUALTECHNOLOGYDOUBLEPOLESINGLETHROW(DPST)SWITCHTIMERSWITCHOSLVPSOSTSF/LnDn2Dn4DnOSDW/PILOTLIGHTP432VAD,OSDKEYOPERATEDKW/THERMOOVERLOADTDUALLEVELSWITCHINGLIGHTINGCONTROLSLVNETWORKENABLEDFIXTUREWIRELESSBATTERYPOWEREDWALLDIMMER,1-GANG,4-POLE0-10VDIMMINGD,WSWIRELESSBATTERYPOWEREDWALLDIMMER,1-GANG1-POLE0-10VDIMMINGD,WSa,b,c20ADUPLEXRECEPTACLE20A(GFCI)GROUNDFAULTCURRENTINTERRUPTERDEVICE20AMOUNTABOVECOUNTERPERADA.MOUNTAT+48"MEASUREDTOTOPOFBOX.NEMA3RCOVER(BELL#1503ORENGINEERAPROVEDEQUAL)FLOORMOUNTEDOUTLETGROUNDBAR20ACEILINGMOUNTEDOUTLETGANGWITHSWITCHDISCONNECTFUSEORNONFUSED20DOUBLEDUPLEXRECEPTACLE20A"CONTROLLED"DUPLEXRECEPTACLEPER2022CAENERGYCODEREQUIREMENTS130-5"CIRCUITCONTROLSFOR120VRECEPTACLES"(LEVITON5362-S2X,HEAVYDUTYSPECGRADE;LEVITON16352-WPX)TELEVISIONRECEPT.VERIFYMOUNTINGHEIGHTPRIORTOROUGH-INCOMBINATIONPOWER/DATAFLOORBOX.PROVIDE4-GANGFLOORBOX(POKE-THRU)(WIREMOLDRFB4SERIES),FOR(1)DUPLEXRECEPTACLEAND(1)CONTROLLEDDUPLEXRECEPTACLE,(1)COMMUNICATIONOUTLET,ANDSPARESPACE.CONTRACTORTOPROVIDEALLACCESSORIESFORAWORKINGSYSTEM.DUPLEXRECEPTACLE.REMOVEBREAK-OFFTAB.TOPOUTLETISCONTROLLEDANDBOTTOMOUTLETISUN-CONTROLLED.CONTROLLEDOUTLETSHALLHAVEAPERMANENTMARKINGTODIFFERENTIATETHEMFROMUNCONTROLLEDOUTLETPER2022CAENERGYCODEREQUIREMENTS.(LEVITON5362S1X,HEAVYDUTYSPECGRADE,LEVITON16352-1PX-DECORA)20ASINGLERECEPTACLE20ADUPLEX-HALFSWITCHEDFLOORMOUNT208V,1ØRECEPTACLE20ASWITCHEDRECEPTACLEDROPCORDRECEPTACLE208V1ØRECEPTACLE20AMPDUPLEXOUTLETWITHTYPEAANDTYPECUSBCHARGERNOTE: PROVIDEALLOUTLETSWITHINRESIDENTIALSPACESWITHTAMPERPROOFDEVICESRECEPTACLEWITHINDICATORLIGHT20A(1)CONTROLLEDDUPLEXRECEPTACLEAND(1)DUPLEXRECEPTACLEWHILE-INUSENEMA3RCOVER(TAYMAC#MX4280SORENGINEERAPROVEDEQUALUNLESSOTHERWISENOTED)ARCFAULTCIRCUITINTERRUPTERPROTECTEDRECEPTACLETAMPERPROOFRECEPTACLENEFnOSPCnOSCnPCnOSHnRPPHnRPnRP(ER)nRPT24LIGHTINGFIXTURESCHEDULESITE/EXTERIORLIGHTINGFIXTURESCHEDULETYPE MANUFACTURER CATALOGNO. VOLTAGEMAXVALAMPING MOUNTINGDESCRIPTIONS2MVOLTLED4000K+80CRIPOLEMOUNTED(+16'OAH)POLEMOUNTEDLUMINAIRE.PROVIDEWITHTYPE3MEDIUMDISTRIBUTIONANDHOUSESIDESHIELD.S3MVOLTLED4000K+80CRIPOLEMOUNTED(+16'OAH)POLEMOUNTEDLUMINAIRE.PROVIDEWITHTYPE2MEDIUMDISTRIBUTIONANDHOUSESIDESHIELD.S5MVOLTLED4000KIN-GROUND PROVIDEADJUSTABLEFLODDLIGHTTOLIGHTUPFLAGPOLE.S9MVOLTLED4000K+80CRICONCRETE 42"LEDBOLLARDW1MVOLTLED4000KWALL(+8'OAH)EXTERIORWALLLIGHT8-1/2"WX4-3/8"HX4"DEEPDOWNDISTRIBUTIONONLYBLACKFINISH,0-10VDIMMINGW3MVOLTLED4000KWALL(+12'OAH)EXTERIORWALLLIGHT12"WX4-3/8"HX4"DEEPBLACKFINISH,0-10VDIMMINGINTERIORLIGHTINGFIXTURESCHEDULETYPE MANUFACTURER CATALOGNO. VOLTAGEMAXVALAMPING MOUNTINGDESCRIPTIONF1AMVOLTLED3500KRECESSED 2'X4'TROFFER0-10VDIMMINGTO1%PROVIDEWITH4,000LUMENSPACKAGE.F1DMVOLTLED3500KRECESSED2'X2'TROFFER0-10VDIMMINGTO1%PROVIDEWITH4,000LUMENSPACKAGE.F2MVOLTLED3500KSURFACE4'LINEARSURFACEMOUNTED,0-10VDIMMINGTO1%F3MVOLTLED3500KWALLLINEARINDIRECT/DIRECT,LENGTHASREQUIREDPERPLANS.(RESTROOM)F5MVOLTLED3500KUNDERCABINETLINEARLEDUNDERCABINET,REFERTOFLOORPLANFORLENGTHINFEETANDPOWERSUPPLYSIZE.(0-10VDIMMINGTO1%),F6MVOLTLED3500KWALLTASKLEDLIGHTINGCHROMEFINISH.PROVIDEON/OFFSWITCHABOVEHEADOFBEDAT+36"AFF.F7AMVOLTLED3500KRECESSED 4"RECESSEDCANWITHDEEPREFLECTOR,FLANGED0-10VDIMMINGTO1%F8MVOLTLED3500KAIRCRAFTCABLE8FTLINEAR,0-10VDIMMING.PROVIDEAIRCRAFTCABLEANDADJUSTTOMOUNTFIXTUREAT+8AFF.F9MVOLTLED3500KPENDANTLEDHIGHBAYFIXTURE,0-10VDIMMINGWITHINTEGRALOCCUPANCYSENSOR.F11MVOLTLED3500KSURFACE 8'LINEARSURFACEMOUNTED,0-10VDIMMINGTO1%X1MVOLTLEDUNIVERSAL(TOP/END/BACKMOUNT)SINGLEFACEUNIVERSALMOUNTLEDEXITSIGNWITHFIELDSELECTABLECHEVRONS.X2MVOLTLEDUNIVERSAL(TOP/END/BACKMOUNT)DOUBLEFACEUNIVERSALMOUNTLEDEXITSIGNWITHFIELDSELECTABLECHEVRONS.X3MVOLTLEDUNIVERSAL(TOP/END/BACKMOUNT)SINGLEFACEUNIVERSALMOUNTLEDEXITSIGNWITHFIELDSELECTABLECHEVRONS.WETLOCATIONRATED.EXITSIGNFIXTURESCHEDULETYPE MANUFACTURER CATALOGNO. VOLTAGEMAXVALAMPING MOUNTINGDESCRIPTIONEF1-002F13MVOLTLED3500KWALLLEDWALLMOUNTEDDECORATIVESCONCE.0-10VDIMMINGTO1%. ATASCADEROPUBLICSAFETY-FIRESTATION101/20/2025SanLuisObispo,CA93406P.O.Box1167-3562EmpleoSt.THOMAELECTRIC,INC.Phone:(805)543-3850cad@thomaelec.comFax:(805)543-3829ThesedrawingsandspecificationswerepreparedbyThomaElectricspecificallyforthisdesign/buildprojectandshallnotbeusedforbiddingpurposesand/orconstructionbyothers.AlldesignsandinformationshownonthedrawingsareinstrumentsofserviceandarethepropertyofThomaElectric,Inc.Visualcontactwiththeseplansandspecificationsshallconstituteprimafacieevidenceoftheacceptanceoftheserestrictions.FIRESTATION1ELECTRICALSINGLELINEDIAGRAMREFERENCENOTES1. NEW(1)4"PRIMARYCONDUIT(PVCSCHEDULE40)PERPACIFICGAS&ELECTRIC(PG&E)REQUIREMENTS.2. NEW(2)5"SECONDARYCONDUITS(PVCSCHEDULE40)PERPG&EREQUIREMENTS.3. TRANSFORMERPAD(106"X90")PERPG&EREQUIREMENTS.4. THREE-SECTIONMAINSWITCHBOARD"MSB"(800ACOPPERBUS,277/480V,3Ø,4W,NEMA1).5. FLOORMOUNTEDAUTOMATICTRANSFERSWITCH"ATS",THREEPOLESOLIDNEUTRALWITHBY-PASSISOLATIONSWITCH(600A,277/480V,3Ø,4W,NEMA1).6. FREESTANDINGDISTRIBUTIONBOARD(600A,277/480V,3Ø,4W,NEMA1,COPPERBUS).7. SURGEPROTECTIONDEVICE"SPD".PROVIDEINTEGRALWITH"MSB"ANDWITHINTERNALDISCONNECTFORPANELBOARDS.PROVIDEKV/PHASEASSHOWN.8. BUSSEDSPACE.9. NOTUSED.10. NOTUSED.11. BRANCHCIRCUITPANELBOARD.SPACESASNOTED.PROVIDECOPPERBUSSING.12. EMERGENCYNATURALGASGENERATOR.350KW,277/480V,3Ø,4W,NEMA3RENCLOSURE.13. PROVIDEBRANCHCIRCUIT(S)FORBLOCKHEATER,BATTERYCHARGER,ETC.VERIFYREQUIREMENTSWITHGENERATORSUPPLIER/MANUFACTURER.14. BONDTOGENERATORGROUNDBUS,METALLICBASEFRAME,HOUSING,ANDCONVAULT(NOTE:GENERATORISNOTDESIGNEDASASEPARATELYDERIVEDSYSTEM).15. REMOTEEMERGENCYSHUT-OFFFORGENERATOR.PROVIDEDBYGENERATORMANUFACTURER,ECTOPROVIDEROUGH-INBOXAND3/4"CONDUITTOGENERATOR.COORDINATEWITHMANUFACTURERFORTERMINATIONPOINTWITHINTHEGENERATORANDWIREREQUIREMENTS.PROVIDEENGRAVEDPLACARD(REDONWHITE)"GENERATOREMERGENCYSHUT-OFF".16. 3/4"C(CONTROLWIRING)PERMANUFACTURER'SREQUIREMENTS.17. 3/4"C(START/STOPCONTROLWIRING)PERMANUFACTURER'SREQUIREMENTS.18. REMOTEGENERATORANNUNCIATORPANEL.PROVIDEALARMSTATUSASREQUIREDBYNFPA110TABLE5.6.5.2FORTHELEVELOFEPSBEINGINSTALLED.19. WALLMOUNTEDPORTABLEGENERATORCONNECTIONPANEL("GCP").TRIPLESWITCH3-WAYMANUALTRANSFERSWITCHTOALLOWFORCONNECTIONSTOPORTABLEGENERATORANDLOADBANKPERCEC700.3(F).ALLFIELDWIRINGTERMINATIONSHALLBETORQUEASREQUIREDPERTHEINSTRUCTIONSONTHEPOWERDISTRIBUTIONBLOCK,CIRCUITBREAKERANDGROUNDLUG.PRIORTOENERGIZING,THECONTRACTORSHALLPERFORMFIELDTESTINGPERMANUFACTURE'SRECOMMENDATION.PROVIDESPECIALSEISMICCERTIFICATIONEXCLUSIVELYONTHEBASISOFAPPROVEDSHAKETABLETESTING,ANDALSOCERTIFIEDBYIBC.MANUALTRANSFERSWITCHMANUFACTURERSHALLPROVIDEACOMPLETEFACTORYASSEMBLED,WIREDANDTESTEDMANUALTRANSFERSWITCH.20. ACDISCONNECTSWITCHMOUNTNEXTTO"MSB".21. PVPANEL.22. PROVIDEBATTERYENERGYSTORAGESYSTEM(BESS)READYPER2022RESIDENTIALCOMPLIANCEMANUAL7.8"BATTERYREADYOVERVIEW".23. PROVIDECONDUITSTUBSBETWEENFUTUREPANELPVANDFUTUREINVERTERLOCATIONS.24. FUTUREINVERTERFORSOLARREADY.25. PROVIDECONDUITSTUBSBETWEENFUTUREINVERTERLOCATIONSANDSOLARZONESONROOF.26. LIVINGSPACESAREOCCUPANCYTYPER-2.PROVIDESOLARPHOTOVOLTAICSYSTEMPERCENCCHAPTER8,150.1(C)14.PROVIDEINVERTERANDROOFMOUNTEDSOLARPANELS.BOD:MICROINVERTER(2)APSYSTEMALTENERGYPOWERSOLARMICROINVERTERTECHNOLOGY#QT2-480(1800VA)AND(6)550WSOLARPANELS(BOD:JINKOSOLAR72HL4-BDV550W).'MSB'M14PRIMARY32J12#3/017G15#3/0"GCP"19(N)600A,277/480,3Ø,4W,42kAIC,NEMA3R.65KAIC51618PULLBOX600A100%6204PVC4013"GEN"SECONDARYM600A3P65KAIC8"ATS"RATED600A/3P"FHDP"SPD7240KA/PHASE6204600A3P60A3PMLOPANELSPD7160kA/PHASE11200460A3P654600ACOPPERBUS,277/480V,3Ø,4WPANELFLDPTRANSFORMERTPFNEMA1150KVA480VTO120/208V,3Ø,4W11225A3P23035104PANELFL1111154HVAC1154PANELFL311200A3P65KAICGANN500A3P146204PVC406204PVC401617SOLARDESIGN2125SOLARZONE(S)23TYPICALPROPOSEDSOLARREADYDESIGNFORNONRESIDENTIALPORTIONOFTHEFIRESTATION.PVINSTALLATIONREQUIRESSEPARATEAPPROVALSANDPERMITS.2026PANELPV(F)INVERTER24(F)BESS22PANEL"FACP"FIREALARMCONTROLBRANCHPANELS.TRANSFORMERS,ANDSWITCHBOARDS,DISTRIBUTIONINCLUDINGELECTRICALSWITCHGEAR:APPLICABLETOTHEPROJECT:STAND-BYGENERATORLEGALLYREQUIREDNONSTRUCTURALCOMPONENTEQUIPMENTTYPEORAPPLICABLEELECTRICALYESYESYESYESSPECIALSEISMICCERTIFICATION(SSC)SUBMITTALTABLESEISMICQUALIFICATION:SUPPLIERSHALLPROVIDEMANUFACTURERSCERTIFICATIONTHATTHEEQUIPMENTLISTEDABOVEFORUSEONTHISPROJECTHASBEENREVIEWEDANDCERTIFIEDBYTHEMANUFACTURERTOMEETTHECURRENTCRITERIAFORSPECIALSEISMICCERTIFICATIONINCOMPLIANCEWITHCBC1705.12.3.INCLUDESEISMICCOMPANIONANCHORAGEREQUIREMENTSFROMTHETESTINGANDASAPPROVEDBYTHEMANUFACTURER.ITSHALLBETHERESPONSIBILITYOFTHECONTRACTORTOFURNISHDOCUMENTATIONFROMTHEMANUFACTURERVERIFYINGCOMPLIANCEDURINGSUBMITTALPROCESS.YESRACK(S)COMMUNICATIONYESCONVAULTFUELTANKABOVEGRADEAUTOMATICTRANSFERSWITCHWITHBY-PASSPANELFL4111154PANELFH2100A3PSPD7160kA/PHASE11FLIT1MLOPANELFLIT2PANELFL21111541154PANELFH1100A3P8KWEMLTGINVERTER611111154115442SPACE30SPACE42SPACE42SPACE42SPACE42SPACE30SPACE42SPACE60A3P654HVAC60A3P654HVACTRANSFORMERTPC#XNEMA175KVA480VTO120/208V,3Ø,4W125A3P1153250AMCB6204(4)#350KCMILTHWN&(1)#1GND.EACHCOPPERFEEDERSCHEDULEFEEDERNO.RACEWAYQUANTITY/SIZECONDUCTORS(2)3"C5104(4)#250KCMILTHWN&(1)#1GND.EACH(2)3"C2303(4)#4/0THWN&(1)#4GND.(1)3"C2004(4)#3/0THWN&(1)#6GND.(1)2"C1154(4)#2THWN&(1)#6GND.(1)1-1/2"CMLOMLO1153(3)#2THWN&(1)#6GND.(1)1-1/2"C653(3)#6THWN&(1)#10GND.(1)1"CMLOMLOMLOMLO800ACOPPERBUS,277/480V,3PH,4-WIREAVAILABLEFAULTCURRENT(42,000AEST.)D=10LFAIC=35,979ASPD7160kA/PHASESPD7160kA/PHASEEF1-003MissingPanelSchedulesandLoadCalculationsCECNEC 690.13ACDisconnectmust beinstalled onexterior LEWISAVETRAFFICWAYTRANS.GEN.TRASHNOTE:NOWORKTOEXISTINGFOUNTAINRRR"ATS"S2S3W1W1"MSB"PROPOSEDPOINTOFINTERCEPTIONOFEXISTINGPG&EPRIMARYLINE.(E)TELEPHONE(AT&T)VAULT(E)CATV(CHARTER)PULLBOX(E)TELEPHONE(AT&T)VAULTANDPEDESTALTOREMAIN(E)ASTOUNDPULLBOXJ243"FLDP"3"FL4""FLDP"45688569J"FLDP"11"EPO""FLDP"1(E)SUBSURFACETRANSFORMERT-1966PROPOSEDPOINTOFINTERCONNECTION.1212"FL4"13"FLDP"14"FLDP"15"FLDP"S2"GCP"S2S3S9S9S9S9ATASCADEROPUBLICSAFETY-FIRESTATION101/20/2025SanLuisObispo,CA93406P.O.Box1167-3562EmpleoSt.THOMAELECTRIC,INC.Phone:(805)543-3850cad@thomaelec.comFax:(805)543-3829ThesedrawingsandspecificationswerepreparedbyThomaElectricspecificallyforthisdesign/buildprojectandshallnotbeusedforbiddingpurposesand/orconstructionbyothers.AlldesignsandinformationshownonthedrawingsareinstrumentsofserviceandarethepropertyofThomaElectric,Inc.Visualcontactwiththeseplansandspecificationsshallconstituteprimafacieevidenceoftheacceptanceoftheserestrictions.FIRESTATION1ELECTRICALSITEPLANNORTHSCALE:ELECTRICALSITEPLAN1/16"=1'-0"REFERENCENOTES1. NEWGASEOUSGENERATORPERSINGLELINEDIAGRAM.2. NEW(1)1"C(PVC)TOPANEL"FLDP"FORGENERATORBATTERY/HEATERCIRCUITS.3. PROVIDETWODEDICATEDCIRCUITSFORMOTORIZEDGATEANDHOMERUNTOPANELASINDICATED.4. STUB(2)3/4"C(PVC)BETWEENGATEMOTORSFORBRANCHCIRCUITINGANDLOWVOLTAGEWIRING.5. 17"X30"COMMUNICATIONSPULLBOXFLUSHINGRADE.PROVIDE(2)1"CONDUITSHOMERUNTOSERVERROOMFORACCESSCONTROLS.6. (1)1"C.TOGATEMOTORFORLOWVOLTAGEWIRING.7. NOTUSED.8. (1)3/4"C.TOKEYPADFORACCESSCONTROLLOWVOLTAGEWIRING.9. 11"X17"LIGHTINGPULLBOXFLUSHINGRADE.PROVIDE(1)1"C.WITHDEDICATEDCIRCUITHOMERUNTOPANEL"FLDP"FORMONUMENTSIGNLIGHTING.10. NOTUSED.11. PROVIDEDEDICATEDCIRCUITFORIRRIGATIONCONTROLLER(EXACTLOCATIONTOBEDETERMINEDBYLANDSCAPE).12. NEW"MEET-ME"VAULTFORLOWVOLTAGEUTILITIES.13. PROVIDE(2)208V,20AMINIMUMBRANCHCIRCUITSANDPOSTMOUNTEDRECEPTACLESPERCALIFORNIAGREENBUILDINGCODESECTION4.106.4.14. PROVIDE(1)208V,20AMINIMUMBRANCHCIRCUITANDPOSTMOUNTEDRECEPTACLEPERCALIFORNIAGREENBUILDINGCODESECTION4.106.4.15. PROVIDE(1)ELECTRICVEHICLECHARGINGSTATION,30A,7.2KWOUTPUT,WITH18'CHARGINGCABLEMINIMUM.PG&EPRIMARYMAINLINE(1)4"C(PVCSCHEDULE40)PG&ESECONDARYSERVICECONDUIT(S)(PVCSCHEDULE40)(SEEHANDOUTPACKAGE)PG&ETRANSFORMERPAD(106"X90)BARRIERPOSTSREQUIREMENTSPERPG&EREQUIREMENTS,PAD-MOUNTEQIPMENTHAVINGTHEFOLLOWINGSETBACKSDONOTREQUIRETHECUSTOMERTOPROVIDEANYOTHERPHYSICALPROTECTION:COMMERCIAL,APARTMENT,CONDOMINIUM,ANDOTHERHIGHDENSITYAREAS:9FEETFROMTHEEDGEOFTHETHOROUGHFAREPAVEMENTDUETOHIGHVEHICULARTRAFFICANDFREQUENTTRUCK-BACKING.ELECTRICALSITELEGENDPG&EPRIMARYMAINLINE(1)6"C(PVCSCHEDULE40)EXISTINGUNDERGROUNDLINESPG&EPADMOUNTJUNCTION(PAD-J)(36"X72")(1)4"C(PVCSCHEDULE40)TELEPHONESERVICECONDUITTO"MEET-ME"BOX(AT&T)(1)2"C(PVCSCHEDULE40)CATVSERVICECONDUITTO"MEET-ME"BOX(CHARTER)(4)4"C(PVCSCHEDULE40)LOWVOLTAGECONDUITSFROM"MEET-ME"BOXTOMPOE.(1)2"C(PVCSCHEDULE40)FIBERSERVICECONDUITTO"MEET-ME"BOX(ASTOUND)EF1S-101TELECOMCONDUITS MUSTBE AT OPPOSITEENDS OF VAULTTELECOMCONDUITS MUSTBE AT OPPOSITEENDS OF VAULTTOS COMMENT:PLEASE REFER TO TOS COMMENTS PROVIDED ON 2. Scoping Document - FS1 Drawings - TOS REVIEW AND1. Scoping Document - FS1 Narrative - TOS REVIEWFOR FIRE STATION 1 F9CKTF9CKTF9CKTF9CKTF9CKTF9CKTF9CKTF9CKTF9CKTF9CKTF9CKTF9CKTF9CKTF9CKTF9CKTF9CKTF9CKTF9CKTF9CKTF9CKTF9CKTF9CKTF9CKTF9CKTn4Dn4Dn4DW3W3W1W1W3W3W1W1W1W1W1W1F11SO F11SOF11F11F11F11nOSnOSnDF8F8nDnDnD OSn2Dn2DOSF11F11F11F1DF1DF1DF1DF1DF1DF1DF1DF1DF1DF1DF1Dn4DnRPnOSnRPT24nDF1DF1DF1DF1DF1DF1DnRPnRPnRPnRPnRPnRPnDnRPT24nRPnOSF1DF1DF1DF1DnOSnRPT24nRPF1DF1DF1DF1DF1DF1DnDnOSnRPT24nRPnDF1DF1DF1DF1DnOSnRPT24nRPnDF1DF1DF1DF1DF7AnOSnRPnDOSOSF11F3-8F1AnDnRPnOSF11F11F11OSF2OSF2F7AF3-8OSF2OSF3-6F3-6nOSX1nDnRPnOSnOSnOSnOSnRPnOSX1F3-6F3-6nRPX1F1AF1AF1AF1DF1AF1AF1AF1AF1DF1AF1AnDnDX1nOSnRPT24nRPnDF1DF1DF1DF1DnOSnRPT24nRPnDF1AF1AF7AF7AW1W1F3-8nOSnRPT24nRPnDVAVAF3-8X1F1AF1AF1AnDnDnOSnOSnRPT24nRPF1AF1AF1AF1AF11W1W1F11W1W1nOSnRPnRPT24n2DF1DF1DF1DF1DF1DF1DnOSnRPF1DF1DF1DF1Dn2DnRPT24nRPnDF2F2F2F2F2F2OSOSF1AF1A F7AF7AF7AF7AnOSnOSnRPnRPX1X1X1F7AF7AF7AF7AX1F1DF1DF1DF1DF1DF1DF1DF1DF1DnOSnOSF1DF1DF1DF1DF1DF1DF1DF1DF1DF7AF7AF7AF7AF7AF7An4Dn4Dn4DMENWOMENELEV.EQUIPR.R.QUIETWATCHJAN.MEDICALSTORAGEB.C.CA&CAPITAINOFFICEFIRECHIEFDEPT.CHIEFOPSCHIEFFIREMARSHALFIREINSP.LOBBYEXEC.BREAKOUTSTOR.E.O.C.STOR.ELECTRICALSERVERWORKBREAKAPP.BAYTURNOUT1TURNOUT2S.C.B.A.HOSEMECH.ELEV.IDFEXERCISECHARGESHOPDECONSTOR.R.R.PATIOSTORAGETRAININGADMINF8F8F8W1W3W3W1STOR.PATIOR.R.PATIOBEDROOM5BEDROOM6DAYROOMF3-6nDn2DnRPnRPnRPnRPnRPnOSVAX2X1X1nOSF1AF1AF1AF1AF1AF1AF1AF1AF6F1DF1DF1DF1DnRPF6BEDROOM3BEDROOM2BEDROOM4F1DF1DF1Dn2DVAR.R.F3-6F3-6R.R.F7AF7AF7ALAUNDRYF1AW1F1DF3-6F3-6X1X1X1X2X1F3-6F3-6F1AF1AF1AOSnOSnOSnOSn2Dn2Dn2Dn2DnOSnOSnRPnRPnRPnRPnRPnRPnRPVAn4Dn4DnRPF5-2F5-2F5-2F6F6F6F6F6F13BEDROOM1F13F13F13F13F1DF1DF1DF1DF1DF1DF1DF1DF1DF1DF1DF1DF1DF1DF1DF1DF1DF1DF1DATASCADEROPUBLICSAFETY-FIRESTATION101/20/2025SanLuisObispo,CA93406P.O.Box1167-3562EmpleoSt.THOMAELECTRIC,INC.Phone:(805)543-3850cad@thomaelec.comFax:(805)543-3829ThesedrawingsandspecificationswerepreparedbyThomaElectricspecificallyforthisdesign/buildprojectandshallnotbeusedforbiddingpurposesand/orconstructionbyothers.AlldesignsandinformationshownonthedrawingsareinstrumentsofserviceandarethepropertyofThomaElectric,Inc.Visualcontactwiththeseplansandspecificationsshallconstituteprimafacieevidenceoftheacceptanceoftheserestrictions.FIRESTATION1LIGHTINGFLOORPLANS1FIRSTFLOORLIGHTINGPLANSCALE:1/8"=1'-0"2SECONDFLOORLIGHTINGPLANSCALE:1/8"=1'-0"EF1-101TOS COMMENT:PLEASE REFER TO TOS COMMENTS PROVIDED ON 2. Scoping Document - FS1 Drawings - TOS REVIEW AND1. Scoping Document - FS1 Narrative - TOS REVIEWFOR FIRE STATION 1 "FL2""FL4""FLIT1""FLIT2"-EF1-201-EF1-201"FH2"M,GM,GTVTVTVTVMTVMMMMMMMMMMMMMTVMMDEDICATEDCIRCUIT@FOLDINGDOORDEDICATEDCIRCUIT@OVERHEADCOILINGDOORCSCSMCSMCSRECESSEDMASTERDOOROPERATOR(TYPOF4)CDCDW,GW,GWIU,GWIU,GWIU,G30A@DRYER@WASHERWIREMOLD@EACHSHELFWITHOUTLETEVERY12"FORRADIOANDEQUIPMENTCHARGINGWIREMOLD@COUNTERWITHOUTLETEVERY12"FORMEDICALEQUIPMENTCHARGINGM,GM,GU30AWIU,GWIU,GWIU,GWIU,GWIU,GMENWOMENELEV.EQUIPR.R.QUIETWATCHJAN.MEDICALSTORAGEB.C.CA&CAPITAINOFFICEFIRECHIEFDEPT.CHIEFOPPSCHIEFFIREMARSHALFIREINSP.LOBBYEXEC.BREAKOUTSTOR.E.O.C.STOR.ELECTRICALSERVERWORKBREAKAPP.BAYTURNOUT1TURNOUT2S.C.B.A.HOSEMECH.TVELEV.IDF@COPIERMMMM,G,UM,G,UM,G,UM,G,UUUM,GM,GM,GGG"FL1"UUDEDICATEDCIRCUIT@FOLDINGDOORCSWIU,GCDDEDICATEDCIRCUIT@OVERHEADCOILINGDOORCSWIU,GCDW,GW,GMGW,GW,GGGMMMMMEXERCISE@ROWMACHINEUUW,GCHARGEUCLG@PROJECTORMTV30A30A30A@DISHWASHER WIREMOLD@EACHSHELFWITHOUTLETEVERY12"FORRADIO&EQUIPMENTCHARGING@TREADMILL@BIKE@BIKESHOP480V@COMP.480V@SCBA1245"SBB"3"PBB"4"SBB"DECONSTOR.R.R.CDCDDEDICATEDCIRCUIT@FOLDINGDOORCSWIU,GDEDICATEDCIRCUIT@OVERHEADCOILINGDOORCSWIU,GW,GW,GTVPATIOSTORAGETRAININGADMINLAUNDRYBEDROOM1BEDROOM2BEDROOM3BEDROOM4BEDROOM5BEDROOM6R.R.R.R.R.R.ELEV.DAYROOMJAN./STOR.PATIO-EF1-201M,G,A,TM,G,A,TM,G,A,TU,A,TA,TA,TA,TU,A,TA,TA,TA,TU,A,TA,TA,TA,TU,A,TA,TA,TA,TU,A,TA,TA,TA,TU,A,TA,TA,TA,TM,GGGGWIU,G,A,T"FL3"30AA,TA,TA,TATASCADEROPUBLICSAFETY-FIRESTATION101/20/2025SanLuisObispo,CA93406P.O.Box1167-3562EmpleoSt.THOMAELECTRIC,INC.Phone:(805)543-3850cad@thomaelec.comFax:(805)543-3829ThesedrawingsandspecificationswerepreparedbyThomaElectricspecificallyforthisdesign/buildprojectandshallnotbeusedforbiddingpurposesand/orconstructionbyothers.AlldesignsandinformationshownonthedrawingsareinstrumentsofserviceandarethepropertyofThomaElectric,Inc.Visualcontactwiththeseplansandspecificationsshallconstituteprimafacieevidenceoftheacceptanceoftheserestrictions.FIRESTATION1POWERFLOORPLANSREFERENCENOTES1. 3/4"FIRERATEDA/CPLYWOOD.2. PROVIDESHUNTTRIPMAINCIRCUITBREAKERFORPANEL.3. PRIMARYBONDINGBUSBAR(PBB).4. SECONDARYBONDINGBUSBAR(SBB).PROVIDE1"C(EMT)WITH(1)#4/0GROUNDWIREBETWEENPBBANDSBBPERTIA-607E.BENDSOFBONDINGCONDUCTORSTERMINATINGATPBBORSBBSHALLHAVEAMINIMUMINSIDEBENDRADIUSOF8INCHES.5. ATEOCAREASPROVIDERECEPTACLESSIMILARTO708.10A(2).1FIRSTFLOORPOWERPLANSCALE:1/8"=1'-0"2SECONDFLOORPOWERPLANSCALE:1/8"=1'-0"EF1-102Provide swreceptacle forgarbagedisposalDedicated cktrequired forsmall applianceareas oncountertop.Refrigeratorreceptacleshould be ondedicated ckt.Dedicated ckt in laundryroomProvide dimensions here or on plan viewNeed to specifyrequirements: Red,non-locking, withindicator light, OR"COPS Compliant"TOS COMMENT:PLEASE REFER TO TOS COMMENTS PROVIDED ON 2. Scoping Document - FS1 Drawings - TOS REVIEW AND1. Scoping Document - FS1 Narrative - TOS REVIEWFOR FIRE STATION 1 FRONTFRONTFRONTFRONTFRONTFRONTWAP4w4444242TVTVAPAP42222244w44APAPTVTVTVTVJJ4@PROJECTORTVTV4412911MENWOMENELEV.EQUIPR.R.QUIETWATCHDECONMEDICALSTORAGEB.C.CA&CAPITAINOFFICEFIRECHIEFDEPT.CHIEFOPPSCHIEFFIREMARSHALADMINLOBBYEXEC.BREAKOUTSTOR.E.O.C.STOR.ELECTRICALSERVERWORKBREAKAPP.BAYTURNOUT1TURNOUT2S.C.B.A.HOSEMECH.TRAININGSTOR.ELEV.IDFEXERCISECHARGEWATCH2424W4448888888822w244TVTVTV2TV44SHOPJAN.R.R.CHARGEFIREINSP.CAMPATIOSTORAGECAMCAMCAMCAM APAPAPCAMCAMRACKSTOBEPROVIDEDBYOTHERS,INSTALLEDBYCONTRACTOR.FRONT3(TYPICAL)2TVLAUNDRYBEDROOM1BEDROOM2BEDROOM3BEDROOM4BEDROOM5BEDROOM6R.R.R.R.R.R.ELEV.DAYROOMJAN./STOR.PATIOAP2222222APWWAPATASCADEROPUBLICSAFETY-FIRESTATION101/20/2025SanLuisObispo,CA93406P.O.Box1167-3562EmpleoSt.THOMAELECTRIC,INC.Phone:(805)543-3850cad@thomaelec.comFax:(805)543-3829ThesedrawingsandspecificationswerepreparedbyThomaElectricspecificallyforthisdesign/buildprojectandshallnotbeusedforbiddingpurposesand/orconstructionbyothers.AlldesignsandinformationshownonthedrawingsareinstrumentsofserviceandarethepropertyofThomaElectric,Inc.Visualcontactwiththeseplansandspecificationsshallconstituteprimafacieevidenceoftheacceptanceoftheserestrictions.FIRESTATION1COMMUNICATIONSFLOORPLANS1FIRSTFLOORCOMMUNICATIONSPLANSCALE:1/8"=1'-0"2SECONDFLOORCOMMUNICATIONSPLANSCALE:1/8"=1'-0"REFERENCENOTES1. PROVIDEFLEXIBLEWHIPCONNECTIONTOPODIUM.COORDINATEEXACTLOCATIONPRIORTOROUGH-IN.2. PROVIDE(4)CAT6ACABLESTOAVCABINET.COORDINATEEXACTLOCATIONPRIORTOROUGH-IN.3. (2)CAT6ACABLESATTELEVISIONHEIGHT.TELEVISIONANDBRACKETTOBEOWNERFURNISHED,OWNERINSTALLED.COORDINATEROUGH-INWITHTELEVISIONMOUNTING.EF1-103NOTE: WIRELESSACCESSPOINTS,CAMERAS,ANDINTERCOMSYSTEMSAREBASEDONASTANDALONEUBIQUITIPRODUCT.EQUIPMENTANDINSTALLATIONBYTHOMAELECTRIC,STARTUPANDCOMMISSIONINGOFSYSTEMSBYCITYOFATASCADERO.AreallCAT6linestobeterminatedinI/Troom?Providecontractorwithdirectionondatalines.Canthecontractorusebulkwireandterminate,orarefactory-terminatedendsrequired?Aredatalinesrequiredforthelightingcontrolsystem?Ifso,whowillinstall?SEE ARCHITECTURAL DRAWINGS FOR MOUNTING HEIGHTCOORDINATELOCATION WITHMECHANICALCOORDINATELOCATION WITHMECHANICALTOS COMMENT:PLEASE REFER TO TOS COMMENTS PROVIDED ON 2. Scoping Document - FS1 Drawings - TOS REVIEW AND1. Scoping Document - FS1 Narrative - TOS REVIEWFOR FIRE STATION 1TOS COMMENT: ADD DISTRESS ALERTAT RECEPTION DESK FSAS1SSSSSSSSSSSSSSSSSSSSSSSSSSSSSSVSVSVSSSSVVVVVVVSSVVVVVVVVVVVVSWPWPWPWPTTTTTTJJMENWOMENELEV.EQUIPR.R.QUIETWATCHDECONMEDICALSTORAGEB.C.CA&CAPITAINOFFICEFIRECHIEFDEPT.CHIEFOPPSCHIEFFIREMARSHALADMINLOBBYEXEC.BREAKOUTSTOR.E.O.C.STOR.ELECTRICALSERVERWORKBREAKAPP.BAYTURNOUT2TURNOUT1S.C.B.A.HOSEMECH.TRAININGSTOR.ELEV.IDFEXERCISECHARGESSSSHOPSVVSJSJVJJJSSJTTSWPFIREINSP.R.R.PATIOSTORAGE4JLAUNDRYBEDROOM1BEDROOM2BEDROOM3BEDROOM4BEDROOM5BEDROOM6R.R.R.R.R.R.ELEV.DAYROOMJAN./STOR.PATIOSVSVSVSVSVSSGSOVSVSVSVSVSSJSSSJV6SWPBR5SERVERROOMBELOWATASCADEROPUBLICSAFETY-FIRESTATION101/20/2025SanLuisObispo,CA93406P.O.Box1167-3562EmpleoSt.THOMAELECTRIC,INC.Phone:(805)543-3850cad@thomaelec.comFax:(805)543-3829ThesedrawingsandspecificationswerepreparedbyThomaElectricspecificallyforthisdesign/buildprojectandshallnotbeusedforbiddingpurposesand/orconstructionbyothers.AlldesignsandinformationshownonthedrawingsareinstrumentsofserviceandarethepropertyofThomaElectric,Inc.Visualcontactwiththeseplansandspecificationsshallconstituteprimafacieevidenceoftheacceptanceoftheserestrictions.FIRESTATION1FSASFLOORPLANS1FIRSTFLOORFIRESTATIONALERTINGSYSTEMPLANSCALE:1/8"=1'-0"2SECONDFLOORFIRESTATIONALERTINGSYSTEMPLANSCALE:1/8"=1'-0"T-BARCEILINGMOUNTED8"SPEAKERWITHVOLUMECONTROL(QUAMC10XBUWSVCANDSSB-2)MOUNTING: FLUSHINT-BARCEILING.ROUGH-IN: SPECIALULRATEDTOPHATSYLEBACKCANANDTILESUPPORTBRIDGE.PROVIDE3/4"EMT.(PULLSTRING)ABOVEACCESSIBLECEILINGSPACEASINDICATEDONPLANS.COMMENTS: INSTALLEDPRIMARILYINT-BARGRIDCEILING.EXTERIORHORNSPEAKER(SPECOTECHNOLOGYWEATHERPROOFALUMINUMPASPEAKER)MOUNTING: +8FTAFF.VERIFYLOCATIONANDMOUNTING.FLUSHINWALL.ROUGH-IN: 4X4BOXSTANDARDDEPTH.(APPLETON4S-3/4)PROVIDE3/4"EMT.(PULLSTRING)ABOVEACCESSIBLECEILINGSPACEASINDICATEDONPLANS.COMMENTHORNSPEAKERBASEMOUNTSDIRECTLYON4X4BOX.- ALLINFRASTRUCTURE,CONDUIT,ELECTRICALBOXESANDENCLOSURES.- FURNISHANDINSTALLDEVICESANDPRE-WIRESPEAKERWIRES.LABELEACHCABLESANDPROVIDE10FTSLACKFORTERMINATIONBYCOUNTY.- THOMATOCUTCEILINGANDPAINTINGBYOTHERS- COUNTYTOTERMINATEATHEADINDEVICEATSERVERROOM.- INSTALLSPEAKERWIRES:BELDENCABLE6304FE#18-6,SHIELDEDSTRANDEDBARECOPPERCONDUCTORS.- PROVIDESEPARATESPEAKERHOMERUNFOREACHDORMANDEXTERIORHORN.APPARATUSBAYWALLLOUDSPEAKER(QUAMSYSTEM3/VC)MOUNTING: +8FTAFF.VERIFYLOCATIONANDSURFACEMOUNTINWALL.ROUGH-IN: 4X4BOXSTANDARDDEPTH.(APPLETON4S-3/4)PROVIDE3/4"EMT.(PULLSTRING)ABOVEACCESSIBLECEILINGSPACEASINDICATEDONPLANS.COMMENT: DIMENSION11-3/8"(H)X11-5/8"(W)X5-5/16"(D)FSASLEGENDSGYPBOARDMOUNTED8"SPEAKERWITHVOLUMECONTROL(QUAMX10XBUWSVCANDERD-8)MOUNTING: FLUSHINCEILINGORWALLDENOTEDWITH"W"(+84"AFF)ROUGH-IN: SPECIALULRATEDTOPHATSTYLEBACKCANWITHSUPPORTPROVIDE3/4"EMT.(PULLSTRING)ABOVEACCESSIBLECEILINGSPACEASINDICATEDONPLANS.COMMENT: USEDIN(GYPBOARD)CEILINGS/WALL.SWPFSASFIRESTATIONALERTINGSYSTEMKIT:MOUNTING: THECOMPONENTSAREHOUSEDINACUSTOMWOODENBOXTHATISBUILTANDINSTALLEDBYCOUNTYFACILITIESROUGH-IN: PROVIDE120VDEDICATEDOUTLETCOMMENTS: COORDINATEEXACTLOCATIONINOFFICE109PRIORTOROUGH-IN.SSHFIRESTATIONALERTINGSYSTEMNOTES-ECWORKSCOPE1. (E)LOCATIONOFCOUNTYHEAD-INALERTINGSYSTEM.OUTLETATTHISWALLWITHADEDICATEDCIRCUIT.2. INSTALLVOLUMECONTROL(QUAM#QC10W)FORSPEAKERS.VERIFYEXACTLOCATIONWITHCOUNTYPRIORTOROUGH-IN.3. ELECTRICALCONTACTENCLOSURE.4. INTERCEPT(E)GASRANGEOUTLETANDEXTENDTOCONTACTENCLOSURE.5. (E)BASERADIO.6. PROVIDETIMECLOCKFOREXTERIORSPEAKER.RADIOTURNOUTTIMER(BOD:MICROFRAMED6340-4-DIGITCOUNTOWNTIMERDISPLAY)MOUNTING: VERIFYLOCATIONANDMOUNTING.FLUSHINWALL.ROUGH-IN: 4X4BOXSTANDARDDEPTH.PROVIDE3/4"EMT.(PULLSTRING)ABOVEACCESSIBLECEILINGSPACEASINDICATEDONPLANS.COMMENT:TURNOUTTIMEDISPLAYATEACHDRIVETHROUGHAPPARATUSBAY.DISPLAYTOBEWALLMOUNTEDATAPPARATUSBAYDOORSATTHEDRIVER'SSIGHTLINEHEIGHTANDONTHEPASSENGERSIDEOFEACHBAY.TTS6"ORBITPENDANTSPEAKER100W,70V(BOGENOPS1BOREQUAL)MOUNTING: FLUSHINCEILINGROUGH-IN: PRIVIDESEISMICCORDANDPROVIDE3/4"EMT.(PULLSTRING)ASINDICATEDONPLANS.COMMENT: PENDANTMOUNTSPEAKEREMERGENCYAPPLIANCE1SHUT-OFFDIAGRAMC60A,4POLE(N)50AELECTRICRANGEOUTLET(IFANY)ELECTRICALCONTACTENCLOSURE.3/4"C(EMT)WITH24VWIRING(SINGLEPAIR)TOALERTINGHEADEND.COORDINATEWITHOWNERVENDOR(STUBCONDUITTOACCESSIBLECEILINGSPACE)GASSHUTOFF(GSO)CONTROLPANELPERPLUMBINGPLANSN1/2"C,EMT,(24VAC)24VACNOTE:24VACWIRINGBYPLUMBINGCONRACTORANDLOWVOLTAGEWIRINGBETWEENCONTROLPANELFSASBYFSASCONTRACTOR.GASRANGEANDHOODREFERENCENOTESEF1-104Shouldn't relays beN.O. so they are in"interrupt" positionunless coil isactivated??TOS COMMENT:PLEASE REFER TO TOS COMMENTS PROVIDED ON 2. Scoping Document - FS1 Drawings - TOS REVIEW AND1. Scoping Document - FS1 Narrative - TOS REVIEWFOR FIRE STATION 1TOS COMMENT: ADD TURNOUT TIMERSTOS COMMENT: ADD TURNOUT TIMERS INRESPONSE PATH FROMSECOND FLOOR AV75cdV15cdAV30cdSDAV75cdAV75cdV15cdV15cdAV30cdV15cdV15cdANNPAV15cdV15cdAV15cdHWPHWPHWPHWPAV15cdAV15cdC/DACTP1SDAV75cdAV75cdAV30cdAV30cd2MMMMMM5DMTF3DDCVMM4SDPPPMENWOMENELEV.EQUIPR.R.QUIETWATCHDECONMEDICALSTORAGEB.C.CA&CAPITAINOFFICEFIRECHIEFDEPT.CHIEFOPPSCHIEFFIREMARSHALFIREINSP.LOBBYEXEC.BREAKOUTSTOR.E.O.C.STOR.ELECTRICALSERVERWORKBREAKAPP.BAYTURNOUT2TURNOUT1S.C.B.A.HOSEMECH.TRAININGSTOR.ELEV.IDFEXERCISECHARGESHOPAV75cdV15cdV15cdAV75cdAV75cdADMINR.R.PATIOSTORAGEAV75cdLAUNDRYBEDROOM1BEDROOM2BEDROOM3BEDROOM4BEDROOM5BEDROOM6R.R.R.R.R.R.ELEV.DAYROOMJAN./STOR.PATIOAV15cdAV15cdV15cdAV75cdSDCOSDSDCOSSDSSDAV15cdWPSDCOSDCOV15cdV15cdSSDSSDSSDSSDAV15cdAV15cdATASCADEROPUBLICSAFETY-FIRESTATION101/20/2025SanLuisObispo,CA93406P.O.Box1167-3562EmpleoSt.THOMAELECTRIC,INC.Phone:(805)543-3850cad@thomaelec.comFax:(805)543-3829ThesedrawingsandspecificationswerepreparedbyThomaElectricspecificallyforthisdesign/buildprojectandshallnotbeusedforbiddingpurposesand/orconstructionbyothers.AlldesignsandinformationshownonthedrawingsareinstrumentsofserviceandarethepropertyofThomaElectric,Inc.Visualcontactwiththeseplansandspecificationsshallconstituteprimafacieevidenceoftheacceptanceoftheserestrictions.FIRESTATION1FIREALARMFLOORPLANS1FIRSTFLOORFIREALARMPLANSCALE:1/8"=1'-0"2SECONDFLOORFIREALARMPLANSCALE:1/8"=1'-0"REFERENCENOTESANN(30cd)(15cd)FA-DEVICELEGENDAVVHWPFTPSDWEATHER-PROOFHORNCANDELARATINGCANDELARATINGVISUALSW/AUDIBLE/VISUALW/SPRINKLERFLOWSWITCHSPRINKLERTAMPERSWITCHMANUALPULLSTATIONSMOKEDETECTORREMOTEANNUNCIATORFIREALARMCONTROLPANELRMRELAYMODULEC/DACTCELLULARDIALER(30cd)(15cd)AVVCANDELARATINGCANDELARATINGVISUALS-CEILINGW/AUDIBLE/VISUAL-CEILINGW/CCDETECTORCHECKVALVEFIRESPRINKLERDOUBLEDDCVMMMONITORMODULESDDUCTMOUNTEDSMOKEDETECTORD**SEEFIREALARMRISERDIAGRAMFORCOMPETEFIREALARMLEGEND10-MTENINPUTMONITORMODULEDMDUALMONITORMODULE1. FIREALARMCONTROLPANEL"FACP-PS",CELLULARDIALERANDFIREALARMDOCUMENTATIONCABINET.LABELCABINET,"SYSTEMRECORDDOCUMENTS.2. FIREALARMREMOTEANNUNCIATOR.3. PROVIDEFIREALARMDUALMONITORMODULEATFIRESPRINKLERRISERTAMPERANDFLOWSWITCH.FIELDVERIFYLOCATIONANDCOORDINATECONNECTIONSWITHFIRESPRINKLERVENDOR.4. PROVIDEFIREALARMMONITORMODULEAND3/4"UNDERGROUNDCONDUITWITHFIREALARMCONDUCTORSATTOFIRESPRINKLERDOUBLEDETECTORCHECKVALVE(DDCV).FIELDVERIFYLOCATIONANDCOORDINATECONNECTIONSWITHFIRESPRINKLERVENDOR.5. PROVIDEFIREALARMMONITORMODULESATEMERGENCYGENERATOR.PROVIDE3/4"UNDERGROUNDCONDUITWITHFIREALARMCONDUCTORSFROMFIREALARMCONTROLPANELTOGENERATOR.FIELDVERIFYLOCATIONANDCOORDINATECONNECTIONSWITHGENERATORVENDOR.EF1-105Add end quoteTOS COMMENT:PLEASE REFER TO TOS COMMENTS PROVIDED ON 2. Scoping Document - FS1 Drawings - TOS REVIEW AND1. Scoping Document - FS1 Narrative - TOS REVIEWFOR FIRE STATION 1 G,A,TG,A,TG@DISHWASHER@GDU,A,TU,A,TA,TA,TA,T,TVA,TA,TA,TM,G,A,TM,G,A,TM,G,A,TM,G,A,T@RANGE@HOODJ1"CONDUITTOPANEL"FL3"FORFUTUREELECTRICRANGEM,G,A,TM,G,A,TA,T,TVU,A,TU,A,TA,T@GD"ATS"150"FLDP""FH1""FHDP"75"GCP""MSB"FORSOLAREQUIPMENT"LINV"(F)(F)@WORKSTATION30A30A30A30A30A30A30A30A30A30A30A30A30A30A30A30A"FLIT1"ATASCADEROPUBLICSAFETY-FIRESTATION101/20/2025SanLuisObispo,CA93406P.O.Box1167-3562EmpleoSt.THOMAELECTRIC,INC.Phone:(805)543-3850cad@thomaelec.comFax:(805)543-3829ThesedrawingsandspecificationswerepreparedbyThomaElectricspecificallyforthisdesign/buildprojectandshallnotbeusedforbiddingpurposesand/orconstructionbyothers.AlldesignsandinformationshownonthedrawingsareinstrumentsofserviceandarethepropertyofThomaElectric,Inc.Visualcontactwiththeseplansandspecificationsshallconstituteprimafacieevidenceoftheacceptanceoftheserestrictions.FIRESTATION1ENLARGEDFLOORPLANS1ENLARGEDPLANATELECTRICALSCALE:1/4"=1'-0"2ENLARGEDPLANATKITCHENSCALE:1/4"=1'-0"3ENLARGEDPLANATSERVERROOMSCALE:1/4"=1'-0"EF1-201Dedicated cktrequired forcountertop smallappliancesDedicated ckt required forrefrigerators/freezers; If using AFCI,add it to the breaker so thereceptacle can be reset withoutmoving the appliance.ADD TELECOMENLARGED PLANTOS COMMENT:PLEASE REFER TO TOS COMMENTS PROVIDED ON 2. Scoping Document - FS1 Drawings - TOS REVIEW AND1. Scoping Document - FS1 Narrative - TOS REVIEWFOR FIRE STATION 1 ATASCADEROPUBLICSAFETY-FIRESTATION201/20/2025SanLuisObispo,CA93406P.O.Box1167-3562EmpleoSt.THOMAELECTRIC,INC.Phone:(805)543-3850cad@thomaelec.comFax:(805)543-3829ThesedrawingsandspecificationswerepreparedbyThomaElectricspecificallyforthisdesign/buildprojectandshallnotbeusedforbiddingpurposesand/orconstructionbyothers.AlldesignsandinformationshownonthedrawingsareinstrumentsofserviceandarethepropertyofThomaElectric,Inc.Visualcontactwiththeseplansandspecificationsshallconstituteprimafacieevidenceoftheacceptanceoftheserestrictions.FIRESTATION2ELECTRICALGENERALNOTES1. REFERTOARCHITECTURALCODESHEETFORFIXTURETYPEROCCUPANCYSPACES.2. ARC-FAULTCIRCUIT-INTERRUPTERPROTECTIONSHALLBEPROVIDEDASREQUIREDIN210.12(A),(B),AND(C).THEARC-FAULTCIRCUITINTERRUPTERSHALLBEINSTALLEDINAREADILYACCESSIBLELOCATION.ALL120VOLT,SINGLEPHASE15AND20AMPEREBRANCHCIRCUITSSUPPLYINGOUTLETSINSTALLEDINDWELLINGUNITKITCHENS,FAMILYROOMS,DININGROOMS,LIVINGROOMS,PARLORS,LIBRARIES,DENS,BEDROOMS,SUNROOMS,RECREATIONROOMS,CLOSET,HALLWAYS,LAUNDRYAREASORSIMILARROOMSORAREASSHALLBEPROTECTEDBYALISTEDARC-FAULTCIRCUITINTERRUPTER,COMBINATIONTYPE,INSTALLEDTOPROVIDEPROTECTIONOFTHEBRANCHCIRCUIT(CEC210-12(A).3. ALLELECTRICALOUTLETSINSTALLEDINBATHROOMS,GARAGES,BASEMENTS,CRAWLSPACES,OUTDOORS,KITCHENCOUNTERS,ANDATWETBARSINKSSHALLHAVEGROUND-FAULTCIRCUIT-INTERRUPTERPROTECTIONINCOMPLIANCEWITHNECArt.210-8,CONSISTINGOF125VOLT,SINGLE-PHASE,15-AND20-AMPERERECEPTACLES.4. ALLRECEPTACLEAPPLIANCEEQUIPMENTSHOWNONPLANSMUSTBECOORDINATEDWITHARCHITECTELEVATIONANDMANUFACTURER'SREQUIREMENTSPRIORTOROUGH-IN.5. EACHMULTI-WIREBRANCHSHALLBEPROVIDEDWITHAMEANSTHATWILLSIMULTANEOUSLYDISCONNECTALLUNGROUNDEDCONDUCTORSATTHEPOINTWHEREBRANCHCIRCUITORIGINATES(ARTICLECEC210.4)6. ALLBATHROOMRECEPTACLEOUTLETSSHALLBESUPPLIEDBYAMINIMUMOFONE20-AMPEREBRANCHCIRCUIT,SUCHCIRCUITSSHALLHAVENOOTHEROUTLETS.THISDEDICATEDCIRCUITMAYSERVICEMORETHANONEBATHROOM.NECART.210-52(d).RECEPTACLESSHALLBEADJACENTTOANDWITHIN36"OFTHEOUTSIDEEDGEOFEACHBASIN.7. ALL125V,15AMPSAND20AMPRECEPTACLEINDWELLINGUNITSSHALLBETAMPER-RESISTANTPERCEC406.12.8. RECESSEDLUMINAIRESINSTALLEDINAREASTORECEIVEINSULATIONSHALLBE"IC"LUMINARIESANDARECERTIFIEDANDLABELEDASAIRTIGHTTOTHESTANDARDSPRESCRIBEDBYTHERESIDENTIALENERGYCODE.9. RECESSEDLIGHTFIXTURESINSTALLEDINAFIRERATEDASSEMBLYSHALLBEINSTALLEDPERTHEAPPROVEDLISTINGORPROTECTEDBYANAPPROVEDMETHOD.10. BATHROOMRECEPTACLESMUSTBEONA20AMP,CIRCUIT(ORCIRCUITS)WITHNOOTHEROUTLETS.11. CEILING-SUSPENDED(PADDLE)FANS(IFSHOWN)SHALLBESUPPORTEDINDEPENDENTLYOFANOUTLETBOXORBYLISTEDOUTLETBOXOROUTLETBOXSYSTEMSIDENTIFIEDFORTHEUSEANDINSTALLEDINACCORDANCEWITHCEC314-27(D),CEC422-18.PROVIDEBOXFORFUTUREPADDLEFANINBEDROOMSIFNOTSHOWNONPLANS.12. ALLLUMINAIRESANDLAMPHOLDERSSHALLBELISTEDCEC410-6.13. HIGHEFFICACYLUMINAIRESOTHERTHANOUTDOORHIDLIGHTINGCONTAINONLYHIGHEFFICACYLAMPSASOUTLINEDINTABLE150-COFTHERESIDENTIALENERGYCODEANDNOTCONTAINAMEDIUMSCREWBASESOCKET.14. LIGHTSINBATHROOMS,GARAGES,LAUNDRYROOMS,ANDUTILITYROOMSMUSTBEHIGHEFFICACY,CONTROLLEDBYADIMMERORCONTROLLEDBYAMANUAL-ONOCCUPANTSENSOR.15. PROVIDEA120VRECEPTACLEANDLIGHTNEARTHEFAUWITHALIGHTSWITCHLOCATEDINTHEATTICACCESS.16. PUSHBOTTOMATFRONTDOORSHALLBE+/-12"FROMDOORJAMB.VERIFYLOCATIONWITHDOORTRIM.17. EACHMULTIWIREBRANCHCIRCUITSHALLBEPROVIDEDWITHAMEANSTHATWILLSIMULTANEOUSLYDISCONNECTALLUNGROUNDEDCONDUCTORATTHEPOINTWHERETHEBRANCHCIRCUITORIGINATES.CEC2104(B)18. STEELELECTRICALBOXESLESSTHANOREQUALTO16SQUAREINCHESCANPENETRATEMEMBRANESOFWALLSWITHUPTOA2HOURRATINGPROVIDEDTHEYARESEPARATEDFROMSUCHPENETRATIONSONTHEOPPOSITESIDEOFTHEWALLBYEITHER24INCHES,ADISTANCEEQUALTOTHEDEPTHOFTHEWALLIFFILLEDWITHCELLULOSELOOSEFILL/ROCKWOOL/MINERALWOOL,SOLIDFIREBLOCKING,ORLISTEDPUTTYPADS(CBC714.3.2)19. PENETRATIONSOFFIRE-RESISTIVEWALLS,FLOOR-CEILINGSSHALLBEPROTECTEDASREQUIREDINCBCSECTIONS714.3&714.4.20. INBATHROOMS,GARAGES,LAUNDRYROOMS,ANDUTILITYROOMSATLEASTONELUMINAIREINEACHOFTHESESPACESSHALLBECONTROLLEDBYAVACANCYSENSOR.(CEC150.0)1. CODECOMPLIANCE:ALLWORKSHALLCONFORMTOANDBEPERFORMEDINACCORDANCEWITHCODES,STANDARDS,ANDORDINANCESASSETFORTHBYTHEAUTHORITIESHAVINGJURISDICTIONANDTHEIRLATESTADOPTEDEDITIONS(INEFFECTATTIMEOFBUILDINGPERMITAPPLICATION)OFTHEFOLLOWINGPUBLICATIONS:A. CALIFORNIACODEOFREGULATIONSTITLE24;INCLUDES2022CALIFORNIAELECTRICALCODE,2022CALIFORNIAFIRECODE,2022CALIFORNIABUILDINGCODE,ETC.WITHLOCALAMENDMENTSASAPPLICABLE.B. AMERICANSWITHDISABILITIESACT(ADA).2. SAFETY:THEELECTRICALCONTRACTORISRESPONSIBLETOMAINTAINALLEQUIPMENTINASAFEANDRESPONSIBLEMANNER.KEEPDEADFRONTEQUIPMENTINPLACEWHILEEQUIPMENTISENERGIZED.CONDUCTALLCONSTRUCTIONOPERATIONSINASAFEMANNERFOREMPLOYEESASWELLASOTHERWORKPERSONSORANYONEVISITINGTHEJOBSITE.PROVIDEBARRIERS,FLAGS,TAPE,ETC.ASREQUIREDFORSAFETY.THECONTRACTORSHALLHOLDALLPARTIESHARMLESSOFNEGLIGENTSAFETYPRACTICES,WHICHMAYCAUSEINJURYTOOTHERSONORNEARTHEJOBSITE.3. FIRERATEDASSEMBLIESSHALLMAINTAINRATINGSASSPECIFIEDINTHECALIFORNIABUILDINGCODECHAPTER7.CONTRACTORSHALLPROVIDEANDINSTALLPHYSICALENCLOSUREAROUNDFIXTURES,PANELS,ETC.ASREQUIRED.ALLASSEMBLIESTOBEPENETRATEDSHALLBEINSTALLEDWITHAPPLICABLETHROUGH-PENETRATIONFIRESTOPSYSTEMASDETERMINEDBYULCLASSIFICATION.BEFORECONSTRUCTION,VERIFYANDCOMPLYWITHREQUIREMENTSOFLOCALAUTHORITYHAVINGJURISDICTION.4. MOUNTINGHEIGHTSSHALLBEASFOLLOWSUNLESSOTHERWISENOTED:+15"AFF:RECEPTACLES,TELEPHONE,TV&DATAOUTLETS.(MEASUREDBOTTOMOFOUTLETBOX)+46"AFF:OUTLETABOVECOUNTER(MEASUREDTOPOFOUTLETBOX)+48"AFF:LIGHTSWITCHES.(MEASUREDTOPOFOUTLETBOX)+48"AFF:FIREALARMMANUALPULLSTATIONS,T-STATS.(MEASUREDTOPOFOUTLETBOX)THELOWEROF+80"AFFTOBOTTOMOFLENS,OR6"BELOWCEILING:FIREALARMVISUALS.ELECTRICALSWITCHES:CONTROLSANDSWITCHESINTENDEDTOBEUSEDBYTHEOCCUPANTOFTHEROOMORAREATOCONTROLLIGHTANDRECEPTACLEOUTLETS,APPLIANCESORCOOLING,HEATINGANDVENTILATINGEQUIPMENT,SHALLBELOCATEDNOMORETHAN48INCHESMEASUREDFROMTHETOPOFTHEOUTLETBOXNORLESSTHAN15INCHESMEASUREDFROMTHEBOTTOMOFTHEOUTLETBOXTOTHELEVELOFTHEFINISHFLOORORWORKINGPLATFORM.[CBC11B-308.1.1]ELECTRICALRECEPTACLEOUTLETS:ELECTRICALRECEPTACLEOUTLETSONBRANCHCIRCUITSOF30AMPERESORLESSANDCOMMUNICATIONSYSTEMRECEPTACLESSHALLBELOCATEDNOMORETHAN48INCHESMEASUREDFROMTHETOPOFTHERECEPTACLEOUTLETBOXORRECEPTACLEHOUSINGNORLESSTHAN15INCHESMEASUREDFROMTHEBOTTOMOFTHERECEPTACLEOUTLETBOXORRECEPTACLEHOUSINGTOTHELEVELOFTHEFINISHFLOORORWORKINGPLATFORM[CBC11B-308.1.2]CONTROLSANDOPERATINGMECHANISMSSHALLCOMPLYWITHTHEREQUIREMENTSOFSECTION11B-309.BEFOREROUGH-IN,VERIFYALLMOUNTINGHEIGHTSANDEXACTLOCATIONSFORALLEQUIPMENTELECTRICALCONNECTIONS,STUB-UPS,RECEPTACLES,OUTLETS,ETC.WITHARCHITECTOROWNER.PLACEDEVICESLOCATEDABOVECOUNTERS,SHELVING,ETC.ANDINBATHROOMSSOASNOTTOCONFLICTWITHEDGESOFWAINSCOTING,COUNTERSPLASH,SHELVING,ETC.ARCHITECTURALSHEETSSHALLGOVERN.5. EQUIPMENTANCHORAGENOTEALLMECHANICALANDELECTRICALEQUIPMENTSHALLBEANCHOREDORBRACEDTOMEETTHEHORIZONTALANDVERTICALFORCESPRESCRIBEDINTHE2016CBC,SECTION1614A.1.13ANDASCE7-05SECTIONS13.3,13.4&13.6.THEATTACHMENTOFTHEFOLLOWINGITEMSSHALLBEDESIGNEDTORESISTTHEFORCESPRESCRIBEDABOVE,BUTNEEDNOTBEDETAILEDONTHEPLANS:A. EQUIPMENTWEIGHINGLESSTHAN400POUNDSSUPPORTEDDIRECTLYONTHEFLOORORROOF.B. FURNITUREREQUIREDTOBEATTACHEDINACCORDANCEWITHPART2,TITLE24,C.C.R..C. TEMPORARYORMOVABLEEQUIPMENT.D. EQUIPMENTWEIGHINGLESSTHAN20POUNDSSUPPORTEDBYVIBRATIONISOLATORS.E. EQUIPMENTWEIGHINGLESSTHAN20POUNDSSUSPENDEDFROMAROOFORFLOORORHUNGFROMAWALL.FORTHOSEELEMENTSTHATDONOTREQUIREDETAILSONTHEAPPROVEDDRAWINGS,THEINSTALLATIONSHALLBESUBJECTTOTHEAPPROVALOFTHEMECHANICAL/ELECTRICALENGINEER.PIPING,DUCTWORK,ANDELECTRICALDISTRIBUTIONSYSTEMBRACINGNOTEPIPING,DUCTWORK,ANDELECTRICALDISTRIBUTIONSYSTEMSSHALLBEBRACEDTORESISTTHEFORCESPRESCRIBEDINASCE7-05SECTION13.3ASDEFINEDINASCE7-05SECTION13.6.8,13.6.7,AND13.6.5.5,ITEM6,RESPECTIVELY.A. FUSING:ALLFUSIBLESAFETYDISCONNECTSWITCHESSHALLBEPROVIDEDWITHDUAL-ELEMENTTIMEDELAYTYPEFUSESSIZEDANDRATEDPEREQUIPMENTMANUFACTURERS'RECOMMENDATIONS.VERIFYWITHEQUIPMENTNAMEPLATEBEFOREINSTALLATION.B. INSTALLSEPARATENEUTRALSFOREACH120VBRANCHCIRCUIT.C. MOTOROVERLOADPROTECTION:WHEREREQUIREDBYNECARTICLE430PARTCANDNOTSHOWNONPLANORPROVIDEDINTEGRALWITHEQUIPMENT,PROVIDEANDINSTALLTHERMALOVERLOADPROTECTIONFORALLMOTORS.D. SPARECONDUITFORRECESSEDPANELS:PROVIDE(1)3/4"SPARECONDUITSTUBUPTOACCESSIBLEABOVECEILINGSPACEAND/ORACCESSIBLESPACEBELOWFOREVERY(3)SPAREBREAKERSPACESASINDICATEDONPANELSCHEDULES.E. DEVICELOCATIONSSHOWNARESCHEMATICANDAPPROXIMATE.EXACTLOCATIONSSHALLBEFIELDVERIFIEDDURINGROUGH-INWITHARCHITECTURALELEVATIONS,CASEWORKSHOPDRAWINGS,FURNITURE,ETC.ANDSHALLBECOORDINATEDWITHOTHERTRADESTOAVOIDCONFLICTWITHOTHEREQUIPMENT.F. ELECTRICALANDCOMMUNICATIONSOUTLETSSHOWNINTHESAMELOCATION,SHALLBEMOUNTEDONOPPOSITESIDESOFTHESAMESTUD.COORDINATEBETWEENELECTRICALANDCOMMUNICATIONSPLANS.G. ALLNEWOUTLETSMUSTBETAMPERPROOF.H. ALL15AND20AMPERERECEPTACLESFORBOTHDAMPANDWETLOCATIONSREQUIREDTOBELISTEDWEATHER-RESISTANT(WR)TYPEPERCEC406.9.I. ALLGFCIPROTECTIONMUSTBEREADILYACCESSIBLE.J. GFCIPROTECTRECEPTACLESINWETLOCATIONMUSTBEFURNISHEDWITHANEXTRADUTYHOODCOVERPERCEC406.9(B)A. NIGHTLIGHT"NL"DESIGNATEDLUMINAIRESININTERIORLOCATIONSSHALLHAVEONEBALLASTCONTINUOUSLYENERGIZED.LUMINAIRESINEXTERIORLOCATIONSSHALLBEAUTOMATICALLYCONTROLLEDTOBEONFROMDUSKTODAWN.B. LIGHTINGFIXTURELOCATIONSSHOWNARESCHEMATIC.REFERTOARCHITECTURALPLANS(REFLECTEDCEILING,ELEVATIONS,ETC.)FOREXACTLOCATIONSANDMOUNTINGHEIGHTSPRIORTOROUGH-IN.C. REFERTOARCHITECT'SREFLECTEDCEILINGPLAN(S)FORCEILINGHEIGHTS,TYPES,FINISHES,ETC.INEACHAREA.VERIFYFLANGETYPES,TRIMKITS,STEMLENGTHS,ETC.FORALLFIXTURESPRIORTOSUBMITTALS.D. CONFIRMLOCATIONOFALLDOORSSWINGSWITHARCHITECTURALPLANSPRIORTOROUGH-INOFSWITCHES.E. PROVIDEUNSWITCHEDHOTLEGOFROOMLIGHTINGBRANCHCIRCUITTOEACHBATTERYPOWEREDEMERGENCYLIGHTANDEXITSIGNFORCONTINUOUSCHARGING.LIGHTINGFLOORPLANNOTESRATEDWALLS/ASSEMBLIESNOTESPOWERFLOORPLANNOTES1. INFIRE-RESISTANCERATEDWALLS,DETAILTHROUGHPENETRATIONSANDMEMBRANEPENETRATIONPERCBC714.4ASNOTEDBELOW:A. STEEL,FERROUSORCOPPERPIPESMAYPENETRATEFIRE-RESISTANCERATEDWALLS,PROVIDEDTHEOPENINGISPROTECTEDASFOLLOWS:(CBC714.4.1)i. TEMPENETRATINGCONCRETEORMASONRYWALLSISAMAXIMUM6INCHESNOMINAL DIAMETERANDTHEAREAOFTHEOPENINGTHROUGHTHEWALLDOESNOTEXCEED144 SQUAREINCHES,CONCRETE,GROUTORMORTARISPERMITTEDWHEREITISINSTALLED THEFULLTHICKNESSOFTHEWALLORTHETHICKNESSREQUIREDTOMAINTAINTHEFIRE-RESISTANCERATING;ORii. WHENTHEANNULARSPACEISPROTECTEDWITHMATERIALTHATMEETSASTME119OR UL263.B. PENETRATIONSSHALLBEFIRE-STOPPEDBYASYSTEMINSTALLEDASTESTEDINACCORDANCEWITHASTME814ORUL1479,ANDSHALLHAVEANFRATINGOFNOTLESSTHANTHEREQUIREDFIRE-RESISTANCERATINGOFTHEWALLPENETRATED.(CBC714.4.1.2)C. MEMBRANEPENETRATIONSOFMAXIMUM2-HOURFIRE-RESISTANCERATEDWALLSBYSTEELELECTRICALBOXESAREPERMITTED,PROVIDEDTHATEACHDOESNOTEXCEED16SQUAREINCHESINAREAANDTHETOTALAREAOFSUCHOPENINGDOESNOTEXCEED100SQUAREINCHESFORANY100SQUAREFEETOFWALLAREA,ANDTHESPACEBETWEENTHEWALLMEMBRANEANDTHEBOXDOESNOTEXCEED1/8INCH.ADDITIONALLY,OUTLETBOXESONOPPOSITESIDESOFTHEWALLSHALLBESEPARATEDBYAHORIZONTALDISTANCEOFNOTLESSTHAN24INCHES(CBC714.4.2EXCEPTION1).D. MEMBRANEPENETRATIONSBYLISTEDELECTRICALBOXESOFANYMATERIALAREPERMITTED,PROVIDEDSUCHBOXESHAVEBEENTESTEDFORUSEINFIRE-RESISTANCERATEDASSEMBLIES,ANDTHESPACEBETWEENTHEWALLMEMBRANEANDTHEBOXDOESNOTEXCEED1/8INCHUNLESSLISTEDOTHERWISE.ADDITIONALLY,OUTLETBOXESONOPPOSEDSIDESOFTHEWALLSHALLBESEPARATEDBYAHORIZONTALDISTANCEOFNOTLESSTHAN24INCHES.(CBC714.4.2EXCEPTION2)E. AFIRESPRINKLERSHALLBEPERMITTEDTOBEUNPROTECTEDPROVIDEDSUCHSPACEISCOVEREDBYAMETALESCUTCHEONPLATE.(CBC714.4.2EXCEPTION5)F. WHEREWALLSAREPENETRATEDBYOTHERMATERIALSOROPENINGSLARGERTHANTHOSEMENTIONEDABOVE,THEYMUSTBEQUALIFIEDBYTESTINACCORDANCEWITHCBC714.4.2EXCEPTION2.2. INFIRE-RESISTANCEHORIZONTALASSEMBLIES,DETAILTHROUGHPENETRATIONSANDMEMBRANEPENETRATIONPERCBC714.5ASNOTEDBELOW:A. STEEL,FERROUSORCOPPERCONDUITSMAYPENETRATEFIRE-RESISTANCERATEDFLOORASSEMBLYWHENTHEANNULARSPACEISPROTECTEDWITHMATERIALTHATMEETSASTME119ORUL263(CBC714.5.1EXCEPTION1)B. PENETRATINGITEMS,ASNOTEDABOVE,WITHAMAXIMUM6INCHESNOMINALDIAMETERSHALLNOTBELIMITEDTOTHEPENETRATIONOFASINGLEFIRE-RESISTANCERATEDFLOORASSEMBLY,PROVIDEDTHATTHEAREAOFTHEOPENINGSDOESNOTEXCEED144SQUAREINCHESINANY100SQUAREFEETOFFLOORAREA.(CBC714.4.1.1EXCEPTION1)C. PENETRATIONSSHALLBEFIRE-STOPPEDBYASYSTEMINSTALLEDASTESTEDINACCORDANCEWITHASTME814ORUL1479.THESYSTEMSHALLHAVEANFRATINGANDTRATINGOFNOTLESSTHAN1-HOURBUTNOTLESSTHANTHEREQUIREDFIRE-RESISTANCERATINGOFTHEFLOORPENETRATED(CBC714.5.1)D. MEMBRANEPENETRATIONSBYLISTEDELECTRICALOUTLETBOXESAREPERMITTEDPROVIDEDSUCHBOXESHAVEBEENTESTEDFORUSEINFIRE-RESISTANCERATEDASSEMBLIES,ANDTHESPACEBETWEENTHECEILINGMEMBRANEANDTHEBOXDOESNOTEXCEED1/8INCHESUNLESSLISTEDOTHERWISE.(CBC714.5.2EXCEPTION4)E. AFIRESPRINKLERSHALLBEPERMITTEDTOBEUNPROTECTEDPROVIDEDSUCHSPACEISCOVEREDBYAMETALESCUTCHEONPLATE.(CBC714.5.2EXCEPTION5)3. JOINTSINSTALLEDINORBETWEENFIRE-RESISTANCERATEDWALL,FLOORORFLOOR/CEILINGASSEMBLIESANDROOFSORROOF/CEILINGASSEMBLIESSHALLBEPROTECTEDANAPPROVEDFIRE-RESISTANTJOINTSYSTEMWITHAFIRE-RESISTANCERATINGNOTLESSTHANTHATOFTHEASSEMBLYINWHICHITISINSTALLED.PROVIDEDETAILS(CBC7145.1)4. FIREDOORSANDFIRE-PROTECTIONRATEDGLAZINGSHALLBEARLABELSASREQUIREDBYCBC716.2.9AND716.3.5.5. FIREDAMPERSSHALLBETHEMINIMUMFIREPROTECTIONRATINGSPECIFIEDINCBCTABLE717.3.2.1FORTHETYPEOFPENETRATION(CBC717.3.2.1)REFERTOSPECIFICATIONS260519FORADDITIONALINFORMATION.1. WIRECONNECTORSSHALLBEMINIMUM75DEGREECENTIGRADERATEDANDPROPERLYSIZEDFORTHENUMBEROFCONDUCTORSBEINGCONNECTED,TERMINATED,SPLICED,ETC.ALLABOVEGRADECONNECTORSSHALLBESOLDERLESSLUGORPLASTICWIRENUTTYPE,SCREWON,PRESSURECABLETYPE(WIREUTORSPRINGNUTTYPE)600VOLT,105DEGREEC,WITHSKIRTTOCOVERALLPORTIONSOFSTRIPPEDWIRES.CONNECTORSHALLBEU.L.RATEDFORNUMBERANDSIZEOFCONDUCTORSBEINGJOINEDTOGETHERASSPLICED.2. WIRESANDCABLESFORLINEVOLTAGESYSTEMANDCONTROLS.WIREANDCABLESHALLBECOPPER,600VOLTRATEDTHROUGHOUT.CONDUCTORS14AWGOT10AWG,SOLIDORSTRANDED.CONDUCTORS8AWGANDLARGER,STRANDED3. ALLCONDUCTORSSHALLBECOPPERUNLESSOTHERWISENOTED.MINIMUMSIZEFORINDIVIDUALCONDUCTORSSHALLBE#12AWGUNLESSOTHERWISENOTEDONPANELSCHEDULEORPLANS.SIZE#8AWGANDLARGERSHALLBESTRANDEDCONDUCTOR.INDIVIDUALCONDUCTORSSHALLBEINSULATEDWITHTYPE,XHHW,THW,THHN/THWN600VOLTINSULATIONUNLESSOTHERWISENOTED.4. PROPERINSULATIONTYPESHALLBEUSEDFORTHEPROPERENVIRONMENTALAPPLICATION(I.E.WATERPROOF,WETLOCATION,PLENUMTEMPERATURERATED).ALLCONDUCTORS,WIRINGCABLEWHEREINSTALLEDBELOWFLOOR,SLABORUNDERGROUNDSHALLBECONSIDEREDWETLOCATIONS,ANDSHALLBERATEDACCORDINGLY.NONWATERPROOFCABLINGISNOTALLOWEDINANYBELOWGRADEORWETAPPLICATION.CONDUITSYSTEMSUSEDONTHISPROJECTSHALLBEASFOLLOWS1. PVCSCHEDULE40-underground/belowslabwithGRSelbowsandriserstapewrapped).2. ELECTRICALMETALLICCONDUIT(EMT)-abovegrade/slabinbuildingconstructionandwhereexposedabove8'-0"aff.3. GALVANIZEDRIGIDSTEEL(GRS)-whereexposedbelow8'-0"aff.and/orwheresubjecttophysicaldamage.4. FLEXIBLESTEELCONDUIT-aboveceilingsand/orconcealedinbuildingconstruction(sealtightflexrequiredinexteriorlocations).5. MCCABLEISALLOWED6. ENTISALLOWEDFORLOWVOLTAGESYSTEMSREFERTOSECTION260533&260500OFSPECIFICATIONSFORADDITIONALINFORMATION.CONDUITSSHALLBEMINIMUM3/4"UNLESSOTHERWISENOTEDORCODEREQUIRESLARGERSIZE,1"FORALLHOMERUNCONDUITSANDWHEREROUTEDBELOWSLABORUNDERGROUND.CONDUITSIZES,WHERENOTNOTEDONTHEDRAWINGS,SHALLBESIZEDFORMAXIMUM40%FILLPERCEC310-6.A. PROVIDESEALTITEPOWER&CONTROLCONNECTIONSTOALLACUNITS.B. ALLEQUIPMENTSHOWNABOVEROOFISNEMA3R.C. VERIFYEXACTEQUIPMENTLOCATIONSANDPOINTSOFCONNECTIONWITHMECHANICALCONTRACTORPRIORTOROUGH-IN.D. CONDUITSHOWNISROUTEDINCEILINGSPACEBELOWROOFDECK.E. NOROOFMOUNTCONDUITISALLOWEDUNLESSOTHERWISENOTED.F. FUSEDISCONNECTSWITCHESPEREQUIPMENTNAMEPLATERATING.G. ALLROOFPENETRATIONSSHALLBEMADEWITHROOFJACKS.SEALINGOFALLROOFPENETRATIONSSHALLBEBYTHEROOFINGCONTRACTOR.H. GFCIPROTECTSERVICERECEPTACLESWITHEXTRADUTYCOVERSMUSTBEINSTALLEDWITHIN25FEETOFEQUIPMENT,PERCEC210.63ANDCMC301.4CONDUCTORSANDCABLESROOFPLANNOTESTYPICALDWELLINGUNITNOTESFIREALARMSYSTEM1. PROVIDEALLWORKANDMATERIALREQUIREDFORACOMPLETEANDOPERATINGFIREALARMSYSTEM.WORKSHALLINCLUDE(BUTNOTBELIMITEDTO):A. SHOPDRAWINGSB. SUBMITTALFORAPPROVALC. COMPLETEINSTALLATIONANDTESTINGD. SYSTEMTRAININGFOROWNER'SREPRESENTATIVEE. WARRANTY2. SUBMITASEPARATESETOFDETAILEDFIREALARMPLANS,SPECIFICATIONSANDENGINEERINGCALCULATIONSINCLUDINGBUTNOTNECESSARILYLIMITEDTO:A. CSFMLISTING#'SANDMANUFACTURERMODEL#'SFOREVERYSYSTEMCOMPONENT WHICHISTOBEINTERCONNECTEDASAPARTOFTHISPROJECT.B. SINGLELINE,RISERANDPOINTTOPOINTWIRINGDIAGRAMSINCLUDINGBATTERYAND VOLTAGEDROPCALCULATIONSFORTHEENTIRESYSTEM.C. INDICATIONOFCONDUCTORTYPE(S),POWER-LIMITEDORNON-POWER-LIMITEDSYSTEM.D. SCALEDELEVATIONOFREMOTEGRAPHICANNUNCIATORPANELATENTRY(IFREQUIRED).E. LISTOFPROPOSEDZONESFORALLINITIATINGDEVICES.F. MATRIXOFSYSTEMOPERATION.G. INFORMATIONASREQUIREDTODEMONSTRATECOMPLIANCEWITHAPPLICABLECODE(S)ANDGAINAPPROVALOFAUTHORITY(IES)HAVINGJURISDICTION.FIREALARMSYSTEMINSTALLATIONSHALLNOTBEGINUNTILSEPARATEPERMITHASBEENOBTAINEDANDALLOFTHEABOVEHASBEENACCEPTEDANDSIGNEDBYTHEAUTHORITY(IES)HAVINGJURISDICTIONANDTHEARCHITECT.AFTERCONSTRUCTION,PROVIDEACCURATEFIELDRECORDDRAWINGSTOOWNER.3. ASAMINIMUM,UNLESSOTHERWISENOTED,FIREALARMCONTROLPANELSHALLBEPROVIDEDWITHBATTERYBACKUP,4ZONESAND1SIGNALCIRCUITWITHPROVISIONSFORFUTUREEXPANSION.PROVIDEWITHDIALER(DACT)ANDCONNECTTOCOMMUNICATIONSSYSTEMWITH(2)DEDICATEDVOICELINESASREQUIREDTOSENDSEPARATEANDDISTINCTSIGNALS(ASREQUIREDBYTHEFIREDEPARTMENT)TOANAPPROVEDCENTRALSTATION.FIRESPRINKLERRISERWATERFLOWAND/ORVALVETAMPERSWITCHESSHALLBEPROVIDEDANDINSTALLEDBYTHESPRINKLERSYSTEMCONTRACTOR,ANDWIREDBACKTOTHEFACPBYTHEFIREALARMCONTRACTOR.COORDINATEFORPROPERVOLTAGE.ALLFIREALARMCOMPONENTSSHALLBECALIFORNIASTATEFIREMARSHALLISTED.4. DUCTSMOKEDETECTORSSHALLBEPROVIDEDBYELECTRICALCONTRACTORANDINSTALLEDBYMECHANICALCONTRACTOR.DETECTORPOWERANDSUPERVISORYWIRINGANDCONNECTIONSSHALLBEMADEBYELECTRICALCONTRACTOR.MECHANICALUNITCONTROL(SHUTDOWNUPONDETECTORALARM)WIRINGANDCONNECTIONSSHALLBEMADEBYMECHANICALCONTRACTOR.FIREALARMSYSTEMGENERATORPOWERSYSTEMA. ITSHALLBETHECONTRACTOR'SRESPONSIBILITYTOCONTACTANDCOORDINATEWITHTHESERVINGUTILITYTOENSUREALLSERVINGUTILITYREQUIREMENTSAREMET.B. ALLSWITCHES,CIRCUITBREAKERSANDOTHEREQUIPMENT,ASSPECIFIED,SHALLHAVETERMINATIONPROVISIONSLISTEDANDIDENTIFIEDFORUSEWITH75DEG.CONDUCTORS,ANDALLFEEDERCONDUCTORS,ANDCONDUITS,ARESIZEBASEDONUSEOF75DEG.CCOPPERWIRESTYPESHWN/THHN.C. ALLEQUIPMENTSHALLHAVEANAPPROVEDTESTINGLABORATORYLABELATTACHED[UL,CSA,ETC.](CEC110-2).D. THEELECTRICALCONTRACTORISRESPONSIBLEFORSUPPLYINGSWITCHGEARSIZEDTOFITINTHEAVAILABLESPACE.REFERTOARCHITECTURALPLANSFORDIMENSIONALINFORMATIONNOTSHOWNONTHEELECTRICALPLANS.CONTRACTORSHALLSUBMITA1/4"SCALEDRAWINGOFALLSWITCHGEAR,ANDTERMINATIONCABINETSONFLOORPLANWITHSUBMITTAL.E. ALLBOXESANDENCLOSURES(INCLUDINGTRANSFERSWITCHES,GENERATORS,ANDPOWERPANELS)FOREMERGENCYCIRCUITSSHALLBEPERMANENTLYMARKEDSOTHEYWILLBEREADILYIDENTIFIEDASACOMPONENTOFANEMERGENCYCIRCUITORSYSTEM,PERNEC700-9(A).F. EMERGENCYLIGHTINGSYSTEM(GENERATORANDAUTOMATICTRANSFER)ANDEXITLIGHTSSHALLBECHECKEDANDAPPROVEDBYTHEFIREDEPARTMENTBEFORETHEAPPROVALOFTHEFINALPLANS.G. INACCORDANCEWITHCEC110.16.PROVIDEARCFLASHPROTECTIONWARNINGLABELSONEACHSWITCHBOARD,PANELBOARD,ANDTRANSFORMER.LABELSSHALLBEPERANSIZ535.4GUIDELINES.(SEEDETAIL)H. ALLPANELSAREBOLT-ONBREAKERS.LOADCENTERSARENOTPERMITTED.I. PERCALIFORNIATITLE24SECTION130.5,WIRINGPROVISIONSHAVEBEENMADEFORDISAGGREGATIONOFTHEELECTRICALCIRCUITS,THEOPTIONALMETERINGHASNOTBEENPROVIDEDFORTHISPROJECT.J. REFERTOPANELSCHEDULESFORINDIVIDUALBRANCHCIRCUITVOLTAGEDROPANDSINGLELINEDIAGRAMFORFEEDERVOLTAGEDROPCALCULATIONS.K. BRANCHCIRCUIT/FEEDERDISTANCEISSHOWNFORREFERENCEONLYASTHEBASISOFVOLTAGEDROPCALCULATIONS.CONDUCTORDISTANCEASINDICATEDSHALLNOTBEUSEDFORBIDDING/CONSTRUCTIONPURPOSES.SHOULDTHEFEEDERDISTANCEEXCEEDTHELENGTHNOTEDPERINSTALLATIONCONDITIONS,NOTIFYTHEENGINEEROFRECORD.TYPICAL.L. TRANSFORMERMUSTBEGROUNDEDTOTHESAMEGROUNDINGELECTRODESYSTEMOFTHEBUILDINGPERCEC250.30(A)(4)ANDBONDEDPERCEC250.104(D).M. PRIMARYDISCONNECTNOTLOCATEDWITHINSIGHTOFTRANSFORMERMUSTHAVELOCKINGMEANSOATREMOTEDISCONNECTANDALABELATTRANSFORMERDENOTINGDISCONNECTLOCATIONPERCEC450.14N. METALWATERPIPINGSYSTEMQUALIFYINGASAGROUNDINGELECTRODEPERCEC250.52(A)(1)MUSTBEBONDEDWITHIN5FEETOFENTERINGTHEBUILDINGPERCEC250.68(C)(1).O. ALLSWITCHBOARD,SWITCHGEAR,PANELBOARDS,ANDMOTORCONTROLCENTERSSHALLBELOCATEDINDEDICATEDSPACESANDPROTECTEDFROMDAMAGEPERCEC110.26E(1)AND/OR(2).P. SERVICECONDUCTORSARETOBEOUTSIDETHEBUILDINGPERCEC230.6.Q. ACCESSANDWORKINGSPACEMUSTBEPROVIDEDABOUTELECTRICALEQUIPMENTREQUIRINGOPERATIONANDMAINTENANCEPERCEC110.26R. PROVIDEREQUIREDIDENTIFICATIONOFPOWERSOURCESBEIDENTIFIEDONTHETRANSFORMER(S)WITHPERMANENTPLAQUEINDICATIONLOCATIONOFALLOTHERSOURCESPER230.2(E),700.7,701.7AND702.7A. APERMANENTPLAQUESHALLBEPLACEDATTHENORMALSERVICEEQUIPMENTDENOTINGTHETYPE&LOCATIONOFTHEON-SITEEMERGENCYSTANDBYPOWERGENERATOR(CEC700-7A,701-7A,702-7A)THEPLAQUESHALLIDENTIFYTHECONNECTIONOFTHEGROUNDINGELECTRODECONDUCTORWHENTHATCONNECTIONISATALOCATIONREMOTEFROMTHEGENERATOR.(CEC700-7B,701-7B,702-7B).SIGNTOREAD"WARNINGSHOCKHAZARDEXISTSIFGROUNDINGELECTRODECONDUCTORORBONDINGJUMPERCONNECTIONINTHISEQUIPMENTISREMOVEDWHILEALTERNATESOURCE(S)ISENERGIZED.B. THEFOLLOWINGEQUIPMENTSHALLBEULLISTEDASINDICATED:- STATIONARYGENERATORS600VORLESSINNON-HAZARDOUSLOCATIONS-(UL2200)- NONEMERGENCYUNINTERRUPTIBLEPOWERSYSTEMS(UPS)-(UL1778)- EMERGENCYRATEDUNINTERRUPTIBLEPOWERSYSTEMS(UPS)-(UL924)- EMERGENCYLIGHTINGANDPOWEREQUIPMENT(UL924)- TRANSFERSWITCHEQUIPMENT(UL1008)- EMERGENCYRATEDLOWLEVELPATHMARKINGANDLIGHTINGSYSTEMS-(UL1994)D. CONFIRMWIRINGREQUIREMENTSWITHGENERATORANDATSPROVIDER.E. PRELIMINARYATSSETTINGARASFOLLOWS.STARTTIMEDELAY:3SECONDSRETRANSFERTIMEDELAY:5MINUTESSTOPTIMEDELAY:THEFINALATSSETTINGSSHALLBEDETERMINEDBYTESTINGCOMPANY.ATSSERVESENTIREFIRESTATIONFACILITY.SINGLELINEDIAGRAMGENERALNOTESEMERGENCYPOWERSYSTEM1. APERMANENTPLAQUESHALLBEPLACEDATTHENORMALSERVICEEQUIPMENTDENOTINGTHETYPE&LOCATIONOFTHEON-SITEEMERGENCYSTANDBYPOWERGENERATORTHEPLAQUESHALLIDENTIFYTHECONNECTIONOFTHEGROUNDINGELECTRODECONDUCTORWHENTHATCONNECTIONISATALOCATIONREMOTEFROMTHEGENERATOR.(NEC700-7,701-7,702-7).2. FORALLSTANDBYGENERATORSYSTEMS,ASIGNSHALLBEPLACEDATTHESERVICEENTRANCEEQUIPMENTINDICATINGTYPEANDLOCATIONOFON-SITEEMERGENCYPOWERSOURCES,PERCEC701-7(A)/702-7(A).3. WHERETHEGROUNDEDCIRCUITCONDUCTORCONNECTEDTOTHEEMERGENCYSOURCEISCONNECTEDTOAGROUNDINGELECTRODECONDUCTORATALOCATIONREMOTEFROMTHEEMERGENCYSOURCE,THERESHALLBEASIGNATTHEGROUNDINGLOCATIONTHATSHALLIDENTIFYALLEMERGENCYANDNORMALSOURCESCONNECTEDATTHATLOCATION,PERCEC701-7(B)/702-7(B).4. LIGHTINGINVERTERWIRINGFROMANEMERGENCYSOURCEOREMERGENCYSOURCEDISTRIBUTIONOVERCURRENTPROTECTIONTOEMERGENCYLOADSSHALLBEKEPTENTIRELYINDEPENDENTOFALLOTHERWIRINGANDEQUIPMENTANDSHALLBEIDENTIFIEDBYPERMANENTMARKING,EXCEPTASNOTEDIN(1)THROUGH(5),PERCEC700.GENERALNOTESCONDUITSYSTEMSNOTESA. ALL15AND20AMPERERECEPTACLESFORBOTHDAMPANDWETLOCATIONSREQUIREDTOBELISTEDWEATHER-RESISTANT(WR)TYPEPERCEC406.9(A)AND(B)B. CEC406.9(A)RECEPTACLESINDAMPLOCATIONS:RECEPTACLESINSTALLEDOUTDOORSINALOCATIONPROTECTEDFROMTHEWEATHERORINOTHERDAMPLOCATIONSSHALLBEANENCLOSUREFORTHERECEPTACLETHATISWEATHERPROOFWHENTHERECEPTACLEISCOVERED(ATTACHMENTPLUGCAPNOTINSERTEDANDRECEPTACLECOVERSCLOSE)C. CEC406.9(B)RECEPTACLESOF15AND20AMP,125AND250VOLTSINSTALLEDINAWETLOCATIONSHALLHAVEANENCLOSURETHATISWEATHERPROOFWHETHERORNOTTHEATTACHMENTPLUGCAPISINSERTED.ANOUTLETBOXHOODINSTALLEDFORTHISPURPOSESHALLBELISTEDANDSHALLBEIDENTIFIEDAS'EXTRA-DUTY"OTHERLISTEDPRODUCTS,ENCLOSURES,ORASSEMBLIESPROVIDINGWEATHERPROOFPROTECTIONTHATDONOTUTILIZEANOUTLETBOXHOODNEEDTOBEMARKED"EXTRADUTY"EXCEPTION:15AND20AMP,125THROUGH250VOLTRECEPTACLESINSTALLEDINAWETLOCATIONANDSUBJECTTOROUTINEHIGH-PRESSURESPRAYWASHINGSHALLBEPERMITTEDTOHAVEANENCLOSURETHATISWEATHERPROOFWHENTHEATTACHMENTPLUGISREMOVED.RECEPTACLESATDAMPANDWETLOCATIONSHEETINDEXSHEETNO.FIRESTATIONSHEETDESCRIPTIONEF2-001 ELECTRICALGENERALNOTESEF2-002 ELECTRICALLEGENDANDABBREVIATIONSEF2-003 SINGLELINEDIAGRAMEF2S-101 ELECTRICALSITEPLANEF2-101LIGHTINGFLOORPLANEF2-102POWERFLOORPLANEF2-103COMMUNICATIONSFLOORPLANEF2-104FIRESTATIONALERTINGFLOORPLANEF2-105FIREALARMFLOORPLANEF2-001CEC 160.5 ATASCADEROPUBLICSAFETY-FIRESTATION201/20/2025SanLuisObispo,CA93406P.O.Box1167-3562EmpleoSt.THOMAELECTRIC,INC.Phone:(805)543-3850cad@thomaelec.comFax:(805)543-3829ThesedrawingsandspecificationswerepreparedbyThomaElectricspecificallyforthisdesign/buildprojectandshallnotbeusedforbiddingpurposesand/orconstructionbyothers.AlldesignsandinformationshownonthedrawingsareinstrumentsofserviceandarethepropertyofThomaElectric,Inc.Visualcontactwiththeseplansandspecificationsshallconstituteprimafacieevidenceoftheacceptanceoftheserestrictions.FIRESTATION2ELECTRICALLEGENDANDABBREVIATIONSPOWERLEGENDNOTE:INTERPRETINCONTEXTMISCELLANEOUSCONDUIT/WIRELIGHTFIXTURESCONVENTIONSLEGEND3103NUMBEREDSHEETNOTES:REFERSTONOTESONSAMESHEETASREFERENCEDETAILREFERENCE:Z=DETAILDESIGNATIONX=SHEETNUMBERREFERENCEZXFEEDERSCHEDULEDESIGNATION(EXAMPLE:3103=310AMPERE,600V,3CURRENTCARRYINGCONDUCTORS,PREFIXES:'M'INDICATESMEDIUMVOLTAGE,'CO14'INDICATESCONDUITONLY,QUANTITY(1)ANDSIZE(4"))XMECHANICALSYSTEMSTAG(REFERTOMECHANICALSHEETS)Y=UNITTYPEX=UNITNUMBERYXCOMBINATIONSTARTERMAGNETICCONTACTORDAMPERMOTORHUMIDISTATSURFACEMOUNTCABINETFLUSHMOUNTCABINETSURFACEMOUNTPANELFLUSHMOUNTPANELPUSHBUTTONHMDMCIRCUITBREAKERFUSIBLESWITCHGROUNDTHERMOSTATSURFACEALETTERADJACENTINDICATES(ARROWINDICATESDIRECTION)FIXTURETYPERECESSEDWALLMOUNTEXITLIGHT-CEILINGEXITLIGHT-WALLWALL-PACKCLOCKPHASEØTMOTORUPLIGHT-FLUSHINGRADEPOLELIGHT-DECORATIVEPENDANTLINEARUNDERCABINETLIGHTTANDEM-WIREDLAMPSBOLLARDSTRIPUONDIRECTIONALFLOODEMERGENCYFIXTUREPOLELIGHTTRACKLIGHTCEILINGSURFACEMOUNTWALLSURFACEMOUNTRECESSEDDOWNLIGHTRECESSEDWALLWASHRECESSEDPENDANTMOUNT(E)POWERHOMERUNINDICATESLINECONTINUESWIRELINE-CONTINUESCONDUITSTUB(W/MARKER)VERTICALCONDUITRUNFLEXIBLECONNECTIONSURFACEMOUNTRACEWAYCORDW/PLUGLOWVOLTAGELVCONDUITSEALNEWPOWERHOMERUN(3HOTS&NEUTSHOWN)ISOLATEDGROUNDEXISTINGTOREMAINNEWEUNDERGROUNDWALLMOUNTEDCLOCKCLOCK/SPEAKERCOMBINATIONSSAFETYDISCONNECTENDOFLINERESISTORCHIMEDUCTSMOKEDETECTORVISUAL-VISUALDEVICEMANUALPULLSTATIONHORN-AUDIBLEDEVICEAUDIBLE/VISUALSMOKEDETECTORHEATDETECTORBELLTAMPERSWITCHTPFLOWSWITCHAVVFHFIREALARMCONTROLPANELREMOTEPOWERSUPPLYRPSSPEAKER/VISUALSVFIREALARMSFDSMOKEFIREDAMPERSDCOSDDSDHBCSMOKEDETECTORWITHCOWALLSURFACEMOUNTLINEARTYPELEDCOVE&UNDERCABINETLIGHTPERFIXTURESCHEDULEJJUNCTIONBOXSDVSMOKEDETECTORWITHVISUALA AMPEREAB AMPBREAKERABAND ABANDONEDABV ABOVEAC ALTERNATINGCURRENTAC-# AIRCONDITIONERADJ ADJACENTAF AMPFUSE,AMPFRAMEAFF ABOVEFINISHFLOORAFG BOVEFINISHGRADEAIC AMPERESINTERRUPTINGCAPACITYAl ALUMINUMAS AMPSWITCHRATINGATS AUTOMATICTIMESWITCHATS AUTOMATICTRANSFERSWITCHAV AUDIBLE/AUDIOVISUALAWG AMERICANWIREGAGEBFG BELOWFINISHGRADEBIL BASICIMPULSELEVELBLDG BUILDINGC CONDUIT-C- CATVCONDUITCAB'T CABINETCATV CABLETELEVISIONCB CIRCUITBREAKER,CODEBLUECBC CA.BUILDINGCODECEC CA.ELECTRICALCODECA.ENERGYCOMMISSIONCF COMPACTFLUORESCENTCFC CALIFORNIAFIRECODECLG CEILINGCL CENTERLINECKT CIRCUITCNT'R CONTRACTORC.O. CONDUITONLY(W/PULLROPE)COND CONDUIT,CONDUCTORCR CRITICALBRANCHCSFM CALIFORNIASFMCT CURRENTTRANSFORMERCu COPPERCU-# CONDENSINGUNITD DEPTHDC DIRECTCURRENTDF DRINKINGFOUNTAINDIA DIAMETERDISC DISCONNECTDIST DISTRIBUTIONDPST DOUBLEPOLESINGLETHROWDW DISHWASHEREM EMERGENCY(E) EXISTINGEA EACHEB ELECTRONICBALLASTEC ELECTRICALCONTRACTOREC-# EVAPORATIVECOOLEREF-# EXHAUSTFANEL EVENINGLIGHTELEC ELECTRICALEM EMERGBATTERYBACKUPEMERGENCYBALLASTEMERG EMERGENCYEOL ENDOFLINEEQUIP'T EQUIPMENTES ENERGYSAVING(EXN) (E)IN(N)LOCATION(EXR) (E)TOBE(R)EXT EXTERIORF FLUORESCENT(F) FUTUREF-# FURNACEFA FIREALARMFACP FIREALARMCONTROLPANELFAT FIREALARMTERMINALFAU FORCEDAIRUNITFBO FURNISHEDBYOTHERSFC-# FANCOILFLA FULLLOADAMPSFLR FLOORFLUOR FLUORESCENTFS FUSIBLESWITCHFVNR FULLVOLTAGENON-REVERSINGG GROUNDINGCONDUCTORGC GENERALCONTRACTORGD GARBAGEDISPOSALGFCI GROUNDFAULTCIRCUITINTERRUPTERGFI GROUNDFAULTCIRCUITINTERRUPTERGND GROUNDGRS GALVANIZEDRIGIDSTEELGWS GANGWITHSWITCHH HEIGHT,HIGHHACR HEATING,AC&REFRIGHID HIGHINTENSITYDISCHARGEHO HIGHOUTPUTHOA HAND-OFF-AUTOhp HORSEPOWERHPF HIGHPOWERFACTORHPS HIGHPRESSURESODIUMIC INTERCOMID IDENTIFICATIONIDF INTERMEDIATEDISTRIBUTIONFRAMEIF INSIDEFROSTIG ISOLATEDGROUNDJ-BOX JUNCTIONBOXk QUANTITY1000kVA KILOVOLTAMPSkW KILOWATTLC LIGHTINGCONTACTORLPS LOWPRESSURESODIUMLRA LOCKEDROTORAMPSLS LIFESAFETYBRANCHLT LIGHTLTG LIGHTINGLV LOWVOLTAGEMC MECHANICALCONTRACTORMCA MINIMUMCKTAMPSMCB MAINCIRCUITBREAKERMCTB MAINCATVTERMINALBOARDMCTC MAINCATVTERMINALCABINETMDF MAINDISTRIBUTIONFRAMEMECH MECHANICALMFR MANUFACTURERMFS MAINFUSIBLESWITCHMH METALHALIDEMLO MAINLUGSONLYMOCP MAXIMUMOCPMPOE MINIMUMPOINTOFENTRYMSB MAINSWITCHBOARDMT MOUNTMTHT MOUNTINGHEIGHTMTS MANUALTRANSFERSWITCHMTTB MAINTELEPHONETERMINALBOARDMTTC MAINTELEPHONETERMINALCABINETMW MICROWAVEN NEUTRAL(GROUNDEDCONDUCTOR)(N) NEWN3R NEMA3RNC NORMALLYCLOSEDNEC NATIONALELECTRICALCODENEMA NAT'LELECMANUFACTURER'SASSOCNIC NOTINCONTRACTNL NIGHTLIGHTNO NORMALLYOPENNPF NORMALPOWERFACTORNTS NOTTOSCALEOC ONCENTEROCP OVERCURRENTPROTECTIONOD OUTSIDEDIAMETEROH OVERHEADOSA OFFICEoftheSTATEARCHITECTOSHPD OFFICEofSTATEWIDEHEALTHPLANNING&DEVELOPMENTOVLD OVERLOADP POLEPA PUBLICADDRESSPB PULLBOXPC PULLCHAINPC PHOTOCELLPC PLUMBINGCONTRACTORph PHASEPNL PANELPOC POINTOFCONNECTION-PP- POWERPRIMARY-PS- POWERSECONDARYPV PHOTOVOLTAIC(R) RELOCATE(D)RECEPTRECEPTACLEREF REFRIGERATORREQ'D REQUIREDRLA RATEDLOADAMPSRM ROOMRMC RIGIDMETALCONDUITRMV REMOVERPLC REPLACERS RAPIDSTARTSC SIGNALCABINETSCC SHORTCKTCURRENTSFM STATEFIREMARSHALSHT SHEETSL SLIMLINE,SWITCHLEGSPEC SPECIFICATIONSPST SINGLEPOLESINGLETHROWSQ SQUARESTR'G STORAGESURF SURFACESVC SERVICESW SWITCHT TRANSFORMER,TERMINAL-T- TELEPHONECONDUIT(TBR) TOBEREMOVEDTC TIMECLOCKTEL TELEPHONETELCO TELEPHONECOMPANYTS TIMESWITCHTSO TIMESWITCHOVERRIDETSP TWISTEDSHIELDEDPAIRTTB TELEPHONETERMINALBOARDTTC TELEPHONETERMINALCABINETTX TRANSFORMERTYP TYPICALTYPSIMTYPICALSIMILARUC UNDERCABINET,UNDERCOUNTERUG UNDERGROUNDUGPS UNDERGROUNDPULLSECTIONUL UNDERWRITERSLABORATORIESUON UNLESSOTHERWISENOTEDUSA UGSVCALERT800-642-2444V VOLTVA VOLTAMPERESVAC VOLTALTERNATINGCURRENTVHO VERYHIGHOUTPUTVOLT VOLTAGEVR VANDAL-RESISTANTW WIDTH,WATT,WIREWH-# WATERHEATERWP WEATHERPROOF(NEMA3R)XFMR TRANSFORMER+48 INDICATESMOUNTINGHEIGHTAFFABBREVIATIONS3-WAYSWITCHSINGLEPOLESINGLETHROW(SPST)SWITCHLIGHTINGPOWERBRANCHCIRCUITLINEVOLTAGECEILINGMOUNTEDOCCUPANCYSENSOR,EXTENDEDRANGE360DEGREES,DUALTECHNOLOGY4-WAYSWITCHNETWORKEDLOWVOLTAGE,DUALTECHNOLOGY,CEILINGMOUNT360°OCCUPANCYSENSOR."C"DENOTESCORNERMOUNT.NETWORKED1-POLEWALLSWITCHWITHDUALTECHNOLOGYOCCUPANCYSENSORANDDIMMINGCONTROLLOWVOLTAGECABLINGPERNETWORKEDSYSTEMREQUIREMENTSNETWORKED0-10VDIMMINGRELAYPACKFORLIGHTFIXTURES.COORDINATEDIMMINGTYPEWITHLIGHTFIXTURE.NETWORKEDRELAYPACKFORCONTROLLEDRECEPTACLESPERT24REQUIREMENTS.LOWVOLTAGECEILINGMOUNTEDOCCUPANCYSENSOR,360DEGREES,DUALTECHNOLOGYNETWORKED2CHANNELSWITCHWITHDIMMINGCONTROLNETWORKEDLOWVOLTAGE,DUALTECHNOLOGY,CEILINGMOUNT360°OCCUPANCYSENSORWITHDAYLIGHTHARVESTING.PROGRAMSENSORTOPROVIDESEPARATECONTROLFORPRIMARYANDSECONDARYDAYLITZONES(ASAPPLICABLE).GENERALLIGHTINGPOWERINASSOCIATEDDAYLITZONESHALLBEREDUCEBYAMINIMUMOF65%.NETWORKED4CHANNELSWITCHWITHDIMMINGCONTROL0-10VORPHASEDIMMINGWALLSWITCH(BASEDONFIXTUREREQUIREMENTS)CEILINGFAN/LIGHTCONTROLWALLSWITCHOCCUPANCYSENSOR,2-BUTTON,DUALTECHNOLOGYWALLSWITCHOCCUPANCYSENSOR,2-BUTTON,PASSIVEINFRAREDNETWORKEDSINGLECHANNELSWITCHWITHDIMMINGCONTROLNETWORKEDAUTOMATICDIMMINGCONTROLPHOTOCELL.SINGLEZONECONTROL.PROGRAMTOPROVIDEDIMMINGCONTROLFORDAYLITZONE.GENERALLIGHTINGPOWERINASSOCIATEDDAYLITZONESHALLBEREDUCEDBYAMINIMUMOF65%.0-10VWALLDIMMINGOCCUPANCYWALLSWITCHNETWORKED0-10VDIMMINGUL924COMPLIANTEMERGENCYRELAYPACKFOREGRESSLIGHTFIXTURES.NETWORKEDPHASEDIMMINGRELAYPACKFORLIGHTFIXTURES.COORDINATEDIMMINGTYPEWITHLIGHTFIXTURE.LINEVOLTAGEPOWERSUPPLYVACANCYSENSORWALLSWITCHNETWORKEDHIGHBAY360DEGREESENSOR.PIROCCUPANCYDETECTION.15MINUTEMAXINTERVALTIMERWALLSWITCHOCCUPANCYSENSOR,SINGLEBUTTON,DUALTECHNOLOGYDOUBLEPOLESINGLETHROW(DPST)SWITCHTIMERSWITCHOSLVPSOSTSF/LnDn2Dn4DnOSDW/PILOTLIGHTP432VAD,OSDKEYOPERATEDKW/THERMOOVERLOADTDUALLEVELSWITCHINGLIGHTINGCONTROLSLVNETWORKENABLEDFIXTUREWIRELESSBATTERYPOWEREDWALLDIMMER,1-GANG,4-POLE0-10VDIMMINGD,WSWIRELESSBATTERYPOWEREDWALLDIMMER,1-GANG1-POLE0-10VDIMMINGD,WSa,b,c20ADUPLEXRECEPTACLE20A(GFCI)GROUNDFAULTCURRENTINTERRUPTERDEVICE20AMOUNTABOVECOUNTERPERADA.MOUNTAT+48"MEASUREDTOTOPOFBOX.NEMA3RCOVER(BELL#1503ORENGINEERAPROVEDEQUAL)FLOORMOUNTEDOUTLETGROUNDBAR20ACEILINGMOUNTEDOUTLETGANGWITHSWITCHDISCONNECTFUSEORNONFUSED20DOUBLEDUPLEXRECEPTACLE20A"CONTROLLED"DUPLEXRECEPTACLEPER2022CAENERGYCODEREQUIREMENTS130-5"CIRCUITCONTROLSFOR120VRECEPTACLES"(LEVITON5362-S2X,HEAVYDUTYSPECGRADE;LEVITON16352-WPX)TELEVISIONRECEPT.VERIFYMOUNTINGHEIGHTPRIORTOROUGH-INCOMBINATIONPOWER/DATAFLOORBOX.PROVIDE4-GANGFLOORBOX(POKE-THRU)(WIREMOLDRFB4SERIES),FOR(1)DUPLEXRECEPTACLEAND(1)CONTROLLEDDUPLEXRECEPTACLE,(1)COMMUNICATIONOUTLET,ANDSPARESPACE.CONTRACTORTOPROVIDEALLACCESSORIESFORAWORKINGSYSTEM.DUPLEXRECEPTACLE.REMOVEBREAK-OFFTAB.TOPOUTLETISCONTROLLEDANDBOTTOMOUTLETISUN-CONTROLLED.CONTROLLEDOUTLETSHALLHAVEAPERMANENTMARKINGTODIFFERENTIATETHEMFROMUNCONTROLLEDOUTLETPER2022CAENERGYCODEREQUIREMENTS.(LEVITON5362S1X,HEAVYDUTYSPECGRADE,LEVITON16352-1PX-DECORA)20ASINGLERECEPTACLE20ADUPLEX-HALFSWITCHEDFLOORMOUNT208V,1ØRECEPTACLE20ASWITCHEDRECEPTACLEDROPCORDRECEPTACLE208V1ØRECEPTACLE20AMPDUPLEXOUTLETWITHTYPEAANDTYPECUSBCHARGERNOTE: PROVIDEALLOUTLETSWITHINRESIDENTIALSPACESWITHTAMPERPROOFDEVICESRECEPTACLEWITHINDICATORLIGHT20A(1)CONTROLLEDDUPLEXRECEPTACLEAND(1)DUPLEXRECEPTACLEWHILE-INUSENEMA3RCOVER(TAYMAC#MX4280SORENGINEERAPROVEDEQUALUNLESSOTHERWISENOTED)ARCFAULTCIRCUITINTERRUPTERPROTECTEDRECEPTACLETAMPERPROOFRECEPTACLENEFnOSPCnOSCnPCnOSHnRPPHnRPnRP(ER)nRPT24LIGHTINGFIXTURESCHEDULESITE/EXTERIORLIGHTINGFIXTURESCHEDULETYPE MANUFACTURER CATALOGNO. VOLTAGEMAXVALAMPING MOUNTINGDESCRIPTIONS2MVOLTLED4000K+80CRIPOLEMOUNTED(+16'OAH)POLEMOUNTEDLUMINAIRE.PROVIDEWITHTYPE3MEDIUMDISTRIBUTIONANDHOUSESIDESHIELD.W1MVOLTLED4000KWALL(+8'OAH)EXTERIORWALLLIGHT8-1/2"WX4-3/8"HX4"DEEPDOWNDISTRIBUTIONONLYBLACKFINISH,0-10VDIMMINGW2MVOLTLED WALL(+8'OAH)LEDVAPORTITEWITHREDGLASSLENS,SHADE,CASTGUARDAND,DRIVERHOUSING73MATTEBLACKFINISHW3MVOLTLED4000KWALL(+12'OAH)EXTERIORWALLLIGHT12"WX4-3/8"HX4"DEEPBLACKFINISH,0-10VDIMMINGINTERIORLIGHTINGFIXTURESCHEDULETYPE MANUFACTURER CATALOGNO. VOLTAGEMAXVALAMPING MOUNTINGDESCRIPTIONF1AMVOLTLED3500KRECESSED 2'X4'TROFFER0-10VDIMMINGTO1%PROVIDEWITH4,000LUMENSPACKAGE.F1DMVOLTLED3500KRECESSED2'X2'TROFFER0-10VDIMMINGTO1%PROVIDEWITH4,000LUMENSPACKAGE.F2MVOLTLED3500KSURFACE4'LINEARSURFACEMOUNTED,0-10VDIMMINGTO1%F3MVOLTLED3500KWALLLINEARINDIRECT/DIRECT,LENGTHASREQUIREDPERPLANS.(RESTROOM)F5MVOLTLED3500KUNDERCABINETLINEARLEDUNDERCABINET,REFERTOFLOORPLANFORLENGTHINFEETANDPOWERSUPPLYSIZE.(0-10VDIMMINGTO1%),F6MVOLTLED3500KWALLTASKLEDLIGHTINGCHROMEFINISH.PROVIDEON/OFFSWITCHABOVEHEADOFBEDAT+36"AFF.F7AMVOLTLED3500KRECESSED 4"RECESSEDCANWITHDEEPREFLECTOR,FLANGED0-10VDIMMINGTO1%F9MVOLTLED3500KPENDANTLEDHIGHBAYFIXTURE,0-10VDIMMINGWITHINTEGRALOCCUPANCYSENSOR.F10MVOLTLED3500KWALLLEDFLOODLIGHTWITHFLATBEAMLENS(APPBAY)F11MVOLTLED3500KSURFACE 8'LINEARSURFACEMOUNTED,0-10VDIMMINGTO1%X1MVOLTLEDUNIVERSAL(TOP/END/BACKMOUNT)SINGLEFACEUNIVERSALMOUNTLEDEXITSIGNWITHFIELDSELECTABLECHEVRONS.X2MVOLTLEDUNIVERSAL(TOP/END/BACKMOUNT)DOUBLEFACEUNIVERSALMOUNTLEDEXITSIGNWITHFIELDSELECTABLECHEVRONS.X3MVOLTLEDUNIVERSAL(TOP/END/BACKMOUNT)SINGLEFACEUNIVERSALMOUNTLEDEXITSIGNWITHFIELDSELECTABLECHEVRONS.WETLOCATIONRATED.EXITSIGNFIXTURESCHEDULETYPE MANUFACTURER CATALOGNO. VOLTAGEMAXVALAMPING MOUNTINGDESCRIPTIONF12MVOLTLED3500KPENDANTDECORATIVELEDPENDANTEF2-002F13MVOLTLED3500KWALLLEDWALLMOUNTEDDECORATIVESCONCE.0-10VDIMMINGTO1%. ATASCADEROPUBLICSAFETY-FIRESTATION201/20/2025SanLuisObispo,CA93406P.O.Box1167-3562EmpleoSt.THOMAELECTRIC,INC.Phone:(805)543-3850cad@thomaelec.comFax:(805)543-3829ThesedrawingsandspecificationswerepreparedbyThomaElectricspecificallyforthisdesign/buildprojectandshallnotbeusedforbiddingpurposesand/orconstructionbyothers.AlldesignsandinformationshownonthedrawingsareinstrumentsofserviceandarethepropertyofThomaElectric,Inc.Visualcontactwiththeseplansandspecificationsshallconstituteprimafacieevidenceoftheacceptanceoftheserestrictions.FIRESTATION2ELECTRICALSINGLELINEDIAGRAM(E)'MSB'32J789#3/012G10(N)65KAIC1113GANNPULLBOX1112100%"GEN"M400A2PRATED200A/2P"EM"SPD4125KA/PHASE2003200A2P60A2P200ABUS,120/240V,1Ø,3W5200A"ATS"40A2P503HVAC40A2P503HVAC40A2P503HVACREPRESENTATIVEMECHANICALLOADS-EXACTSIZINGTOBEDETERMINEDREFERENCENOTES1. EXISTINGPOLEMOUNTTRANSFORMER.2. EXISTINGPG&ESECONDARYCONDUITS.3. EXISTINGTWO-SECTIONMAINSWITCHBOARD"MSB"(400AMAIN,120/240V,1Ø,3W,NEMA3R)TOBERELOCATED.4. SURGEPROTECTIONDEVICE"SPD".PROVIDEINTERNALDISCONNECTFORPANELBOARDS.PROVIDEKV/PHASEASSHOWN.5. FLOORMOUNTEDAUTOMATICTRANSFERSWITCH"ATS",TWOPOLESOLIDNEUTRAL(200A,120/240V,1Ø,3W,NEMA3R).6. NEWBRANCHCIRCUITPANELBOARD.SPACESASNOTED.PROVIDECOPPERBUSSING.7. OPTIONALSTANDBYNATURALGASGENERATOR.50KW,120/240V,1Ø,3WWITHNEMA3RENCLOSURE.(BOD:KOHLERKG50)8. PROVIDEBRANCHCIRCUIT(S)FORBLOCKHEATER,BATTERYCHARGER,ETC.VERIFYREQUIREMENTSWITHGENERATORSUPPLIER/MANUFACTURER.9. PROVIDEGROUNDRODS,ONEATGENERATORPADINFLUSHMOUNTEDGROUNDBOXWITH#3/0BARECOPPERTOCONVAULTEQUIPMENTGROUNDINGLUG.BONDTOGENERATORGROUNDBUS,METTALICBASEFRAMEANDHOUSING(NOTE:GENERATORISNOTDESIGNEDASASEPARATELYDERIVEDSYSTEM.10. REMOTEEMERGENCYSHUT-OFFFORGENERATOR.PROVIDEDBYGENERATORMANUFACTURER,ECTOPROVIDEROUGH-INBOXAND3/4"CONDUITTOGENERATOR.COORDINATEWITHMANUFACTURERFORTERMINATIONPOINTWITHINTHEGENERATORANDWIREREQUIREMENTS.PROVIDEENGRAVEDPLACARD(REDONWHITE)"GENERATOREMERGENCYSHUT-OFF".11. 3/4"C(CONTROLWIRING)PERMANUFACTURER'SREQUIREMENTS.12. 3/4"C(START/STOPCONTROLWIRING)PERMANUFACTURER'SREQUIREMENTS.13. REMOTEGENERATORANNUNCIATORPANEL.PROVIDEALARMSTATUSASREQUIREDBYNFPA110TABLE5.6.5.2FORTHELEVELOFEPSBEINGINSTALLED.14. WALLMOUNTEDPORTABLEGENERATORCONNECTIONPANEL("GCP").TRIPLESWITCH3-WAYMANUALTRANSFERSWITCHTOALLOWFORCONNECTIONSTOPORTABLEGENERATORANDLOADBANKPERCEC700.3(F).ALLFIELDWIRINGTERMINATIONSHALLBETORQUEASREQUIREDPERTHEINSTRUCTIONSONTHEPOWERDISTRIBUTIONBLOCK,CIRCUITBREAKERANDGROUNDLUG.PRIORTOENERGIZING,THECONTRACTORSHALLPERFORMFIELDTESTINGPERMANUFACTURE'SRECOMMENDATION.PROVIDESPECIALSEISMICCERTIFICATIONEXCLUSIVELYONTHEBASISOFAPPROVEDSHAKETABLETESTING,ANDALSOCERTIFIEDBYIBC.MANUALTRANSFERSWITCHMANUFACTURERSHALLPROVIDEACOMPLETEFACTORYASSEMBLED,WIREDANDTESTEDMANUALTRANSFERSWITCH.15. INTERCEPTANDEXTENDEXISTINGUTILITYCONDUIT(S)(PVCSCHEDULE40)TONEWLOCATIONOFMAINSWITCHBOARDPERPG&ECONSTRUCTIONDRAWINGS.16. PROVIDENEWFEEDERFROMRELOCATED"MSB"TOEXISTINGPANEL.17. BRANCHCIRCUITSTOSELECTLOADSTOBEBACKEDUPBYTHEGENERATOR.18. EXISTINGNON-EMERGENCYLOADSTOREMAIN.EXISTINGEMERGENCYLOADSTOHAVEBRANCHCIRCUITSINTERCEPTEDANDEXTENDEDTONEWPANEL"EM".NEWNON-EMERGENCYLOADSTOBEFEDOUTOFEXISTINGPANEL"A".(E)120032003"GCP"14(N)200A,120/240,1Ø,3W,42kAIC,NEMA3R.200342SPACENEMA3R750WEMLTGINVERTER20A1P252COPPERFEEDERSCHEDULEFEEDERNO.RACEWAYQUANTITY/SIZECONDUCTORS1153(3)#2THWN&(1)#6GND.(1)1-1/2"C503(3)#8THWN&(1)#10GND.(1)1"C252(2)#12THWN&(1)#12GND.(1)3/4"C400ACOPPERBUS,120/240V,1PH,3-WIREAVAILABLEFAULTCURRENT(25,000AEST.)15200A2P(N)2003200A2P(E)1153100A2P(E)1153100A2P(E)PANELA(E)PANELB(E)PANELC(E)6172003(3)#3/0THWN&(1)#6GND.(1)2"C32SPACE(30)(N)AFCIBREAKERS&CIRCUITS16161618EF2-003Optional?METALLICMissingPanelSchedulesandLoadCalculationsVanir - not optional FD WH DNDNDNDNDN(E)PP52(N)POSTTOPLIGHT41"MSB"33"ATS""GCP"J"EM"76S2ATASCADEROPUBLICSAFETY-FIRESTATION201/20/2025SanLuisObispo,CA93406P.O.Box1167-3562EmpleoSt.THOMAELECTRIC,INC.Phone:(805)543-3850cad@thomaelec.comFax:(805)543-3829ThesedrawingsandspecificationswerepreparedbyThomaElectricspecificallyforthisdesign/buildprojectandshallnotbeusedforbiddingpurposesand/orconstructionbyothers.AlldesignsandinformationshownonthedrawingsareinstrumentsofserviceandarethepropertyofThomaElectric,Inc.Visualcontactwiththeseplansandspecificationsshallconstituteprimafacieevidenceoftheacceptanceoftheserestrictions.FIRESTATION2ELECTRICALSITEPLANNORTHSCALE:ELECTRICALSITEPLAN1"=10'REFERENCENOTES1. NEWLOCATIONOFEXISTING2-SECTIONSWITCHBOARD.SEESINGLELINEDIAGRAM.2. EXISTINGLOWVOLTAGEUTILITYPULLBOX.PROVIDEEXTENSIONRINGANDNEWCOVERTOADJUSTBOXTONEWGRADE.3. EXISTINGLOWVOLTAGEUTILITYCONDUITSTOREMAIN.4. EXISTINGPG&ESECONDARYSERVICECONDUIT(S)TOBEINTERCEPTEDANDEXTENDEDTORELOCATEDMAINSWITCHBOARD"MSB".PROVIDENEW2'X3'PULLBOXPERPG&EREQUIREMENTS.EXISTINGPOLEMOUNTEDTRANSFORMERTOREMAIN(FIELDLOCATEEXISTINGROUTINGTOPROTECTINPLACE).5. EXISTINGUTILITYPOLE.6. NEWGASEOUSGENERATORPERSINGLELINEDIAGRAM.7. NEW1"C(PVC40)HOMERUNTOPANEL"EM"FORGENERATORBATTERY/HEATERCIRCUITS.PG&ESECONDARYSERVICECONDUIT(S)(PVCSCHEDULE40)(SEEHANDOUTPACKAGE)ELECTRICALSITELEGENDEXISTINGUNDERGROUNDLINES(2)4"C(PCVSCHEDULE40)LOWVOLTAGECONDUITSFROM(E)PULLBOXTOMPOE.EF2S-101SHOW EXISTINGTELECOMPATHWAYTOS COMMENT:PLEASE REFER TO TOS COMMENTS PROVIDED ON 4. Scoping Document - FS 2 Drawings - TOS REVIEW AND 3. Scoping Document - FS2 Narrative - TOS REVIEWFOR FIRE STATION 2 FDWHBUNKF6F7AF7AAPPBAYF9F9F5F1AF1AF1AF1DF1DF1AF1AF1AF1AF1AF1AF1AF1AF1DF1AF1AF1AF1AF1AF1AF1AF1AF2F11F10F10W1F10F10W3W3F2W1W1W1F5F2F2F3-4F7AOSnDnDnOSnRPnRPnDnOSn4DnRPn2DnRPn2DnRPn2DnRPn2DnRPW2F6F6F6F9F9F9F9F9F9F9F3-8F3-8F3-6F2nRPF7AnRPF7AF7AF7AF12F12F7AF7AF7AF7AF7AF7AnRPnOSnOSnOSnDnDnDWSDWSDWSDWSD1INVINVINVINVINVINVINVINVINVINVX3INVX3INVX1INVX2INVnDnDnRPnRPnRPnDnOSnOSnOSnDnOSnRPnRPnRPOSnDnOSW1W1W1X1INVF13F13F13F13F11F11nDnDnRPnRPnOSnOSOSHALLRRRRJANTURNOUTITMEDSTORAGELAUNDRYLOBBYWATCHDECONRRWELLNESSCENTERDAYROOMBUNKBUNKBUNKRRSHOPATASCADEROPUBLICSAFETY-FIRESTATION201/20/2025SanLuisObispo,CA93406P.O.Box1167-3562EmpleoSt.THOMAELECTRIC,INC.Phone:(805)543-3850cad@thomaelec.comFax:(805)543-3829ThesedrawingsandspecificationswerepreparedbyThomaElectricspecificallyforthisdesign/buildprojectandshallnotbeusedforbiddingpurposesand/orconstructionbyothers.AlldesignsandinformationshownonthedrawingsareinstrumentsofserviceandarethepropertyofThomaElectric,Inc.Visualcontactwiththeseplansandspecificationsshallconstituteprimafacieevidenceoftheacceptanceoftheserestrictions.FIRESTATION2LIGHTINGFLOORPLANREFERENCENOTES1. EXISTINGLIGHTSWITHINAPPARATUSBAYTOBEREMOVEDANDREPLACEDWITHNEWASSHOWN.1LIGHTINGFLOORPLANSCALE:1/4"=1'-0"EF2-101HallwaysandcorridorsneedemergencyegresslightingArethehatchedluminairesnightlightsoremergencylights?Thisreviewerhasn'tseenarchsheets.DaylightzonesshouldbeshownonthesesheetsifnottheA-sheets.Aredaylightsensorsinstalledinthissystem?TOS COMMENT:PLEASE REFER TO TOS COMMENTS PROVIDED ON 4. Scoping Document - FS 2 Drawings - TOS REVIEW AND 3. Scoping Document - FS2 Narrative - TOS REVIEWFOR FIRE STATION 2 FDWHA,TA,TU,A,TU,A,TU,A,TU,A,TA,TA,TA,TA,TA,TA,TA,TM,G,A,TM,G,A,TM,G,A,TGCDCDCDCDG@GRINDERG@COUNTERWIREMOLD@COUNTERWITHOUTLETEVERY12"FOREQUIPMENTCHARGINGGGGM,GM,G@DRYER@WASHERGMMM@ELIPTICAL@STATIONARYBIKE@TREADMILLUUUUUM,GM,G@RANGE@HOODM,GG@DISHWASHERG@DISPOSALM,GM,G@REFRIGERATOR@REFRIGERATOR@REFRIGERATORUUUTVUWIU,GWIU,G30A/2PM,G@DRYINGRACKWIU,GWIU,G"MSB""ATS""GCP""EM""INV"2@AVCAB.3BUNKAPPBAYHALLRRRRJANTURNOUTITMEDSTORAGELAUNDRYLOBBYWATCHDECONRRWELLNESSCENTERDAYROOMBUNKBUNKBUNKRR1SHOPATASCADEROPUBLICSAFETY-FIRESTATION201/20/2025SanLuisObispo,CA93406P.O.Box1167-3562EmpleoSt.THOMAELECTRIC,INC.Phone:(805)543-3850cad@thomaelec.comFax:(805)543-3829ThesedrawingsandspecificationswerepreparedbyThomaElectricspecificallyforthisdesign/buildprojectandshallnotbeusedforbiddingpurposesand/orconstructionbyothers.AlldesignsandinformationshownonthedrawingsareinstrumentsofserviceandarethepropertyofThomaElectric,Inc.Visualcontactwiththeseplansandspecificationsshallconstituteprimafacieevidenceoftheacceptanceoftheserestrictions.FIRESTATION2POWERFLOORPLANREFERENCENOTES1. EXISTINGOUTLETSINTHISROOMTOREMAIN.PROVIDENEWASSHOWN.2. DEDICATEDCIRCUITFORDATACABINET.3. APPROXIMATELOCATIONOFEXISTINGBRANCHCIRCUITPANELBOARDSTOREMAIN.RELOCATE/REROUTE/EXTENDEXISTINGBRANCHCIRCUIT(S)TOREMAINASNEEDEDTOMAINTAINPROPEROPERATIONOFTHESYSTEM.1POWERFLOORPLANSCALE:1/4"=1'-0"NOTE: ANYWORKNOTSHOWNONPLANSISCONSIDEREDEXISTINGTOREMAIN.EF2-102TOS COMMENT:PLEASE REFER TO TOS COMMENTS PROVIDED ON 4. Scoping Document - FS 2 Drawings - TOS REVIEW AND 3. Scoping Document - FS2 Narrative - TOS REVIEWFOR FIRE STATION 2 FDWHAPAP4IDF22222APAPAPWTV22222911TV2TV24BUNKAPPBAYHALLRRRRJANTURNOUTITMEDSTORAGELAUNDRYLOBBYWATCHDECONRRWELLNESSCENTERDAYROOMBUNKBUNKBUNKRRSHOP1(TYPICAL)ATASCADEROPUBLICSAFETY-FIRESTATION201/20/2025SanLuisObispo,CA93406P.O.Box1167-3562EmpleoSt.THOMAELECTRIC,INC.Phone:(805)543-3850cad@thomaelec.comFax:(805)543-3829ThesedrawingsandspecificationswerepreparedbyThomaElectricspecificallyforthisdesign/buildprojectandshallnotbeusedforbiddingpurposesand/orconstructionbyothers.AlldesignsandinformationshownonthedrawingsareinstrumentsofserviceandarethepropertyofThomaElectric,Inc.Visualcontactwiththeseplansandspecificationsshallconstituteprimafacieevidenceoftheacceptanceoftheserestrictions.FIRESTATION2COMMUNICATIONSFLOORPLAN1COMMUNICATIONSFLOORPLANSCALE:1/4"=1'-0"EF2-103NOTE: WIRELESSACCESSPOINTS,CAMERAS,ANDINTERCOMSYSTEMSAREBASEDONASTANDALONEUBIQUITIPRODUCT.EQUIPMENTANDINSTALLATIONBYTHOMAELECTRIC,STARTUPANDCOMMISSIONINGOFSYSTEMSBYCITYOFATASCADERO.REFERENCENOTES1. (2)CAT6ACABLESATTELEVISIONHEIGHT.TELEVISIONANDBRACKETTOBEOWNERFURNISHED,OWNERINSTALLED.COORDINATEROUGH-INWITHTELEVISIONMOUNTING.TOS COMMENT:PLEASE REFER TO TOS COMMENTS PROVIDED ON 4. Scoping Document - FS 2 Drawings - TOS REVIEW AND 3. Scoping Document - FS2 Narrative - TOS REVIEWFOR FIRE STATION 2 FDWH4BR5FSAS13JSSTTTTTTV2SWP1-GSOSSSSVSSSSSVVVSSSSVVVVVVVSSSSSSVSVSSSSSSWP66VSSVJJJJVVVSVSVVVBUNKAPPBAYHALLRRRRJANTURNOUTITMEDSTORAGELAUNDRYLOBBYWATCHDECONRRWELLNESSCENTERDAYROOMBUNKBUNKBUNKRRSHOPATASCADEROPUBLICSAFETY-FIRESTATION101/20/2025SanLuisObispo,CA93406P.O.Box1167-3562EmpleoSt.THOMAELECTRIC,INC.Phone:(805)543-3850cad@thomaelec.comFax:(805)543-3829ThesedrawingsandspecificationswerepreparedbyThomaElectricspecificallyforthisdesign/buildprojectandshallnotbeusedforbiddingpurposesand/orconstructionbyothers.AlldesignsandinformationshownonthedrawingsareinstrumentsofserviceandarethepropertyofThomaElectric,Inc.Visualcontactwiththeseplansandspecificationsshallconstituteprimafacieevidenceoftheacceptanceoftheserestrictions.FIRESTATION1FSASFLOORPLAN1FIRESTATIONALERTINGSYSTEMFLOORPLANSCALE:1/4"=1'-0"REFERENCENOTEST-BARCEILINGMOUNTED8"SPEAKERWITHVOLUMECONTROL(QUAMC10XBUWSVCANDSSB-2)MOUNTING: FLUSHINT-BARCEILING.ROUGH-IN: SPECIALULRATEDTOPHATSYLEBACKCANANDTILESUPPORTBRIDGE.PROVIDE3/4"EMT.(PULLSTRING)ABOVEACCESSIBLECEILINGSPACEASINDICATEDONPLANS.COMMENTS: INSTALLEDPRIMARILYINT-BARGRIDCEILING.EXTERIORHORNSPEAKER(SPECOTECHNOLOGYWEATHERPROOFALUMINUMPASPEAKER)MOUNTING: +8FTAFF.VERIFYLOCATIONANDMOUNTING.FLUSHINWALL.ROUGH-IN: 4X4BOXSTANDARDDEPTH.(APPLETON4S-3/4)PROVIDE3/4"EMT.(PULLSTRING)ABOVEACCESSIBLECEILINGSPACEASINDICATEDONPLANS.COMMENTHORNSPEAKERBASEMOUNTSDIRECTLYON4X4BOX.- ALLINFRASTRUCTURE,CONDUIT,ELECTRICALBOXESANDENCLOSURES.- FURNISHANDINSTALLDEVICESANDPRE-WIRESPEAKERWIRES.LABELEACHCABLESANDPROVIDE10FTSLACKFORTERMINATIONBYCOUNTY.- THOMATOCUTCEILINGANDPAINTINGBYOTHERS- COUNTYTOTERMINATEATHEADINDEVICEATMULTI-PURPOSEOFFICE109.- INSTALLSPEAKERWIRES:BELDENCABLE6304FE#18-6,SHIELDEDSTRANDEDBARECOPPERCONDUCTORS.- PROVIDESEPARATESPEAKERHOMERUNFOREACHDORMANDEXTERIORHORN.APPARATUSBAYWALLLOUDSPEAKER(QUAMSYSTEM3/VC)MOUNTING: +8FTAFF.VERIFYLOCATIONANDSURFACEMOUNTINWALL.ROUGH-IN: 4X4BOXSTANDARDDEPTH.(APPLETON4S-3/4)PROVIDE3/4"EMT.(PULLSTRING)ABOVEACCESSIBLECEILINGSPACEASINDICATEDONPLANS.COMMENT: DIMENSION11-3/8"(H)X11-5/8"(W)X5-5/16"(D)FSASLEGENDSGYPBOARDMOUNTED8"SPEAKERWITHVOLUMECONTROL(QUAMX10XBUWSVCANDERD-8)MOUNTING: FLUSHINCEILINGORWALLDENOTEDWITH"W"(+84"AFF)ROUGH-IN: SPECIALULRATEDTOPHATSTYLEBACKCANWITHSUPPORTPROVIDE3/4"EMT.(PULLSTRING)ABOVEACCESSIBLECEILINGSPACEASINDICATEDONPLANS.COMMENT: USEDIN(GYPBOARD)CEILINGS/WALL.SWPFSASFIRESTATIONALERTINGSYSTEMKIT:MOUNTING: THECOMPONENTSAREHOUSEDINACUSTOMWOODENBOXTHATISBUILTANDINSTALLEDBYCOUNTYFACILITIESROUGH-IN: PROVIDE120VDEDICATEDOUTLETCOMMENTS: COORDINATEEXACTLOCATIONINOFFICE109PRIORTOROUGH-IN.SSHFIRESTATIONALERTINGSYSTEMNOTESECWORKSCOPE1. (N)LOCATIONOFCOUNTYHEAD-INALERTINGSYSTEM.OUTLETATTHISWALLWITHADEDICATEDCIRCUIT.2. INSTALLVOLUMECONTROL(QUAM#QC10W)FORSPEAKERS.VERIFYEXACTLOCATIONWITHCOUNTYPRIORTOROUGH-IN.3. ELECTRICALCONTACTENCLOSURE.4. HOMEGAS/ELECTRICALRANGEOUTLETTOCONTACTENCLOSURE.5. (N)BASERADIO.PROVIDE12"X12"X4"FLUSHMOUNTEDAND2"CONDUITTOITROOM.6. PROVIDETIMECLOCKFOREXTERIORSPEAKER.RADIOTURNOUTTIMER(BOD:MICROFRAMED6340-4-DIGITCOUNTOWNTIMERDISPLAY)MOUNTING: VERIFYLOCATIONANDMOUNTING.FLUSHINWALL.ROUGH-IN: 4X4BOXSTANDARDDEPTH.PROVIDE3/4"EMT.(PULLSTRING)ABOVEACCESSIBLECEILINGSPACEASINDICATEDONPLANS.COMMENT:TURNOUTTIMEDISPLAYATEACHDRIVETHROUGHAPPARATUSBAY.DISPLAYTOBEWALLMOUNTEDATAPPARATUSBAYDOORSATTHEDRIVER'SSIGHTLINEHEIGHTANDONTHEPASSENGERSIDEOFEACHBAY.TTS6"ORBITPENDANTSPEAKER100W,70V(BOGENOPS1BOREQUAL)MOUNTING: FLUSHINCEILINGROUGH-IN: PRIVIDESEISMICCORDANDPROVIDE3/4"EMT.(PULLSTRING)ASINDICATEDONPLANS.COMMENT: PENDANTMOUNTSPEAKER1EMERGENCYAPPLIANCESHUT-OFFDIAGRAMC60A,4POLE(N)50AELECTRICRANGEOUTLET(IFANY)ELECTRICALCONTACTENCLOSURE.3/4"C(EMT)WITH24VWIRING(SINGLEPAIR)TOALERTINGHEADEND.COORDINATEWITHOWNERVENDOR(STUBCONDUITTOACCESSIBLECEILINGSPACE)GASSHUTOFF(GSO)CONTROLPANELPERPLUMBINGPLANSN1/2"C,EMT,(24VAC)24VACNOTE:24VACWIRINGBYPLUMBINGCONRACTORANDLOWVOLTAGEWIRINGBETWEENCONTROLPANELFSASBYFSASCONTRACTOR.GASRANGEANDHOODEF2-104Shouldn't relays beN.O. so they are in"interrupt" positionunless coil isactivated?TOS COMMENT:PLEASE REFER TO TOS COMMENTS PROVIDED ON 4. Scoping Document - FS 2 Drawings - TOS REVIEW AND 3. Scoping Document - FS2 Narrative - TOS REVIEWFOR FIRE STATION 2 FDWHSDSSDSSDSSDSV15cdSDCOAV30cdAV15cdAV15cdANNPV15cdAV15cdAV15cdHWPV15cdSDCOSDCOV15cdAV75cdAV75cdHWPHWPC/DACTP1SD2TFDM3MMMMMMDDCVMM45PPPPAV15cdV15cdV15cdV15cdHWPSDCOAV30cdSDSBUNKAPPBAYHALLRRRRJANTURNOUTITMEDSTORAGELAUNDRYLOBBYWATCHDECONRRWELLNESSCENTERDAYROOMBUNKBUNKBUNKRRSHOPATASCADEROPUBLICSAFETY-FIRESTATION101/20/2025SanLuisObispo,CA93406P.O.Box1167-3562EmpleoSt.THOMAELECTRIC,INC.Phone:(805)543-3850cad@thomaelec.comFax:(805)543-3829ThesedrawingsandspecificationswerepreparedbyThomaElectricspecificallyforthisdesign/buildprojectandshallnotbeusedforbiddingpurposesand/orconstructionbyothers.AlldesignsandinformationshownonthedrawingsareinstrumentsofserviceandarethepropertyofThomaElectric,Inc.Visualcontactwiththeseplansandspecificationsshallconstituteprimafacieevidenceoftheacceptanceoftheserestrictions.FIRESTATION1FIREALARMFLOORPLAN1FIREALARMFLOORPLANSCALE:1/4"=1'-0"REFERENCENOTESANN(30cd)(15cd)FA-DEVICELEGENDAVVHWPFTPSDWEATHER-PROOFHORNCANDELARATINGCANDELARATINGVISUALSW/AUDIBLE/VISUALW/SPRINKLERFLOWSWITCHSPRINKLERTAMPERSWITCHMANUALPULLSTATIONSMOKEDETECTORREMOTEANNUNCIATORFIREALARMCONTROLPANELRMRELAYMODULEC/DACTCELLULARDIALER(30cd)(15cd)AVVCANDELARATINGCANDELARATINGVISUALS-CEILINGW/AUDIBLE/VISUAL-CEILINGW/CCDETECTORCHECKVALVEFIRESPRINKLERDOUBLEDDCVMMMONITORMODULESDDUCTMOUNTEDSMOKEDETECTORD**SEEFIREALARMRISERDIAGRAMFORCOMPETEFIREALARMLEGEND10-MTENINPUTMONITORMODULEDMDUALMONITORMODULE1. FIREALARMCONTROLPANEL"FACP-PS",CELLULARDIALERANDFIREALARMDOCUMENTATIONCABINET.LABELCABINET,"SYSTEMRECORDDOCUMENTS.2. FIREALARMREMOTEANNUNCIATOR.3. PROVIDEFIREALARMDUALMONITORMODULEATFIRESPRINKLERRISERTAMPERANDFLOWSWITCH.FIELDVERIFYLOCATIONANDCOORDINATECONNECTIONSWITHFIRESPRINKLERVENDOR.4. PROVIDEFIREALARMMONITORMODULEAND3/4"UNDERGROUNDCONDUITWITHFIREALARMCONDUCTORSTOFIRESPRINKLERDOUBLEDETECTORCHECKVALVE(DDCV).FIELDVERIFYLOCATIONANDCOORDINATECONNECTIONSWITHFIRESPRINKLERVENDOR.5. PROVIDEFIREALARMMONITORMODULESATEMERGENCYGENERATOR.PROVIDE3/4"UNDERGROUNDCONDUITWITHFIREALARMCONDUCTORSFROMFIREALARMCONTROLPANELTOGENERATOR.FIELDVERIFYLOCATIONANDCOORDINATECONNECTIONSWITHGENERATORVENDOR.EF2-105Noreviewnotesforthissheet.TOS COMMENT:PLEASE REFER TO TOS COMMENTS PROVIDED ON 4. Scoping Document - FS 2 Drawings - TOS REVIEW AND 3. Scoping Document - FS2 Narrative - TOS REVIEWFOR FIRE STATION 2 ATASCADEROPUBLICSAFETY-POLICESTATION01/20/2025SanLuisObispo,CA93406P.O.Box1167-3562EmpleoSt.THOMAELECTRIC,INC.Phone:(805)543-3850cad@thomaelec.comFax:(805)543-3829ThesedrawingsandspecificationswerepreparedbyThomaElectricspecificallyforthisdesign/buildprojectandshallnotbeusedforbiddingpurposesand/orconstructionbyothers.AlldesignsandinformationshownonthedrawingsareinstrumentsofserviceandarethepropertyofThomaElectric,Inc.Visualcontactwiththeseplansandspecificationsshallconstituteprimafacieevidenceoftheacceptanceoftheserestrictions.ELECTRICALGENERALNOTES1. CODECOMPLIANCE:ALLWORKSHALLCONFORMTOANDBEPERFORMEDINACCORDANCEWITHCODES,STANDARDS,ANDORDINANCESASSETFORTHBYTHEAUTHORITIESHAVINGJURISDICTIONANDTHEIRLATESTADOPTEDEDITIONS(INEFFECTATTIMEOFBUILDINGPERMITAPPLICATION)OFTHEFOLLOWINGPUBLICATIONS:A. CALIFORNIACODEOFREGULATIONSTITLE24;INCLUDES2022CALIFORNIAELECTRICALCODE,2022CALIFORNIAFIRECODE,2022CALIFORNIABUILDINGCODE,ETC.WITHLOCALAMENDMENTSASAPPLICABLE.B. AMERICANSWITHDISABILITIESACT(ADA).2. SAFETY:THEELECTRICALCONTRACTORISRESPONSIBLETOMAINTAINALLEQUIPMENTINASAFEANDRESPONSIBLEMANNER.KEEPDEADFRONTEQUIPMENTINPLACEWHILEEQUIPMENTISENERGIZED.CONDUCTALLCONSTRUCTIONOPERATIONSINASAFEMANNERFOREMPLOYEESASWELLASOTHERWORKPERSONSORANYONEVISITINGTHEJOBSITE.PROVIDEBARRIERS,FLAGS,TAPE,ETC.ASREQUIREDFORSAFETY.THECONTRACTORSHALLHOLDALLPARTIESHARMLESSOFNEGLIGENTSAFETYPRACTICES,WHICHMAYCAUSEINJURYTOOTHERSONORNEARTHEJOBSITE.3. FIRERATEDASSEMBLIESSHALLMAINTAINRATINGSASSPECIFIEDINTHECALIFORNIABUILDINGCODECHAPTER7.CONTRACTORSHALLPROVIDEANDINSTALLPHYSICALENCLOSUREAROUNDFIXTURES,PANELS,ETC.ASREQUIRED.ALLASSEMBLIESTOBEPENETRATEDSHALLBEINSTALLEDWITHAPPLICABLETHROUGH-PENETRATIONFIRESTOPSYSTEMASDETERMINEDBYULCLASSIFICATION.BEFORECONSTRUCTION,VERIFYANDCOMPLYWITHREQUIREMENTSOFLOCALAUTHORITYHAVINGJURISDICTION.4. MOUNTINGHEIGHTSSHALLBEASFOLLOWSUNLESSOTHERWISENOTED:+15"AFF:RECEPTACLES,TELEPHONE,TV&DATAOUTLETS.(MEASUREDBOTTOMOFOUTLETBOX)+46"AFF:OUTLETABOVECOUNTER(MEASUREDTOPOFOUTLETBOX)+48"AFF:LIGHTSWITCHES.(MEASUREDTOPOFOUTLETBOX)+48"AFF:FIREALARMMANUALPULLSTATIONS,T-STATS.(MEASUREDTOPOFOUTLETBOX)THELOWEROF+80"AFFTOBOTTOMOFLENS,OR6"BELOWCEILING:FIREALARMVISUALS.ELECTRICALSWITCHES:CONTROLSANDSWITCHESINTENDEDTOBEUSEDBYTHEOCCUPANTOFTHEROOMORAREATOCONTROLLIGHTANDRECEPTACLEOUTLETS,APPLIANCESORCOOLING,HEATINGANDVENTILATINGEQUIPMENT,SHALLBELOCATEDNOMORETHAN48INCHESMEASUREDFROMTHETOPOFTHEOUTLETBOXNORLESSTHAN15INCHESMEASUREDFROMTHEBOTTOMOFTHEOUTLETBOXTOTHELEVELOFTHEFINISHFLOORORWORKINGPLATFORM.[CBC11B-308.1.1]ELECTRICALRECEPTACLEOUTLETS:ELECTRICALRECEPTACLEOUTLETSONBRANCHCIRCUITSOF30AMPERESORLESSANDCOMMUNICATIONSYSTEMRECEPTACLESSHALLBELOCATEDNOMORETHAN48INCHESMEASUREDFROMTHETOPOFTHERECEPTACLEOUTLETBOXORRECEPTACLEHOUSINGNORLESSTHAN15INCHESMEASUREDFROMTHEBOTTOMOFTHERECEPTACLEOUTLETBOXORRECEPTACLEHOUSINGTOTHELEVELOFTHEFINISHFLOORORWORKINGPLATFORM[CBC11B-308.1.2]CONTROLSANDOPERATINGMECHANISMSSHALLCOMPLYWITHTHEREQUIREMENTSOFSECTION11B-309.BEFOREROUGH-IN,VERIFYALLMOUNTINGHEIGHTSANDEXACTLOCATIONSFORALLEQUIPMENTELECTRICALCONNECTIONS,STUB-UPS,RECEPTACLES,OUTLETS,ETC.WITHARCHITECTOROWNER.PLACEDEVICESLOCATEDABOVECOUNTERS,SHELVING,ETC.ANDINBATHROOMSSOASNOTTOCONFLICTWITHEDGESOFWAINSCOTING,COUNTERSPLASH,SHELVING,ETC.ARCHITECTURALSHEETSSHALLGOVERN.5. EQUIPMENTANCHORAGENOTEALLMECHANICALANDELECTRICALEQUIPMENTSHALLBEANCHOREDORBRACEDTOMEETTHEHORIZONTALANDVERTICALFORCESPRESCRIBEDINTHE2016CBC,SECTION1614A.1.13ANDASCE7-05SECTIONS13.3,13.4&13.6.THEATTACHMENTOFTHEFOLLOWINGITEMSSHALLBEDESIGNEDTORESISTTHEFORCESPRESCRIBEDABOVE,BUTNEEDNOTBEDETAILEDONTHEPLANS:A. EQUIPMENTWEIGHINGLESSTHAN400POUNDSSUPPORTEDDIRECTLYONTHEFLOORORROOF.B. FURNITUREREQUIREDTOBEATTACHEDINACCORDANCEWITHPART2,TITLE24,C.C.R..C. TEMPORARYORMOVABLEEQUIPMENT.D. EQUIPMENTWEIGHINGLESSTHAN20POUNDSSUPPORTEDBYVIBRATIONISOLATORS.E. EQUIPMENTWEIGHINGLESSTHAN20POUNDSSUSPENDEDFROMAROOFORFLOORORHUNGFROMAWALL.FORTHOSEELEMENTSTHATDONOTREQUIREDETAILSONTHEAPPROVEDDRAWINGS,THEINSTALLATIONSHALLBESUBJECTTOTHEAPPROVALOFTHEMECHANICAL/ELECTRICALENGINEER.PIPING,DUCTWORK,ANDELECTRICALDISTRIBUTIONSYSTEMBRACINGNOTEPIPING,DUCTWORK,ANDELECTRICALDISTRIBUTIONSYSTEMSSHALLBEBRACEDTORESISTTHEFORCESPRESCRIBEDINASCE7-05SECTION13.3ASDEFINEDINASCE7-05SECTION13.6.8,13.6.7,AND13.6.5.5,ITEM6,RESPECTIVELY.SHEETNO.POLICESTATIONSHEETDESCRIPTIONEP-001 ELECTRICALGENERALNOTESEP-002 ELECTRICALLEGENDANDABBREVIATIONSEP-003 SINGLELINEDIAGRAMEPS-101 ELECTRICALSITEPLANEP-101LIGHTINGFLOORPLANEP-102POWERFLOORPLANEP-103COMMUNICATIONSFLOORPLANEP-104FIREALARMFLOORPLANA. FUSING:ALLFUSIBLESAFETYDISCONNECTSWITCHESSHALLBEPROVIDEDWITHDUAL-ELEMENTTIMEDELAYTYPEFUSESSIZEDANDRATEDPEREQUIPMENTMANUFACTURERS'RECOMMENDATIONS.VERIFYWITHEQUIPMENTNAMEPLATEBEFOREINSTALLATION.B. INSTALLSEPARATENEUTRALSFOREACH120VBRANCHCIRCUIT.C. MOTOROVERLOADPROTECTION:WHEREREQUIREDBYNECARTICLE430PARTCANDNOTSHOWNONPLANORPROVIDEDINTEGRALWITHEQUIPMENT,PROVIDEANDINSTALLTHERMALOVERLOADPROTECTIONFORALLMOTORS.D. SPARECONDUITFORRECESSEDPANELS:PROVIDE(1)3/4"SPARECONDUITSTUBUPTOACCESSIBLEABOVECEILINGSPACEAND/ORACCESSIBLESPACEBELOWFOREVERY(3)SPAREBREAKERSPACESASINDICATEDONPANELSCHEDULES.E. DEVICELOCATIONSSHOWNARESCHEMATICANDAPPROXIMATE.EXACTLOCATIONSSHALLBEFIELDVERIFIEDDURINGROUGH-INWITHARCHITECTURALELEVATIONS,CASEWORKSHOPDRAWINGS,FURNITURE,ETC.ANDSHALLBECOORDINATEDWITHOTHERTRADESTOAVOIDCONFLICTWITHOTHEREQUIPMENT.F. ELECTRICALANDCOMMUNICATIONSOUTLETSSHOWNINTHESAMELOCATION,SHALLBEMOUNTEDONOPPOSITESIDESOFTHESAMESTUD.COORDINATEBETWEENELECTRICALANDCOMMUNICATIONSPLANS.G. ALLNEWOUTLETSMUSTBETAMPERPROOF.H. ALL15AND20AMPERERECEPTACLESFORBOTHDAMPANDWETLOCATIONSREQUIREDTOBELISTEDWEATHER-RESISTANT(WR)TYPEPERCEC406.9.I. ALLGFCIPROTECTIONMUSTBEREADILYACCESSIBLE.J. GFCIPROTECTRECEPTACLESINWETLOCATIONMUSTBEFURNISHEDWITHANEXTRADUTYHOODCOVERPERCEC406.9(B)A. NIGHTLIGHT"NL"DESIGNATEDLUMINAIRESININTERIORLOCATIONSSHALLHAVEONEBALLASTCONTINUOUSLYENERGIZED.LUMINAIRESINEXTERIORLOCATIONSSHALLBEAUTOMATICALLYCONTROLLEDTOBEONFROMDUSKTODAWN.B. LIGHTINGFIXTURELOCATIONSSHOWNARESCHEMATIC.REFERTOARCHITECTURALPLANS(REFLECTEDCEILING,ELEVATIONS,ETC.)FOREXACTLOCATIONSANDMOUNTINGHEIGHTSPRIORTOROUGH-IN.C. REFERTOARCHITECT'SREFLECTEDCEILINGPLAN(S)FORCEILINGHEIGHTS,TYPES,FINISHES,ETC.INEACHAREA.VERIFYFLANGETYPES,TRIMKITS,STEMLENGTHS,ETC.FORALLFIXTURESPRIORTOSUBMITTALS.D. CONFIRMLOCATIONOFALLDOORSSWINGSWITHARCHITECTURALPLANSPRIORTOROUGH-INOFSWITCHES.E. PROVIDEUNSWITCHEDHOTLEGOFROOMLIGHTINGBRANCHCIRCUITTOEACHBATTERYPOWEREDEMERGENCYLIGHTANDEXITSIGNFORCONTINUOUSCHARGING.LIGHTINGFLOORPLANNOTESRATEDWALLS/ASSEMBLIESNOTESPOWERFLOORPLANNOTES1. INFIRE-RESISTANCERATEDWALLS,DETAILTHROUGHPENETRATIONSANDMEMBRANEPENETRATIONPERCBC714.4ASNOTEDBELOW:A. STEEL,FERROUSORCOPPERPIPESMAYPENETRATEFIRE-RESISTANCERATEDWALLS,PROVIDEDTHEOPENINGISPROTECTEDASFOLLOWS:(CBC714.4.1)i. TEMPENETRATINGCONCRETEORMASONRYWALLSISAMAXIMUM6INCHESNOMINAL DIAMETERANDTHEAREAOFTHEOPENINGTHROUGHTHEWALLDOESNOTEXCEED144 SQUAREINCHES,CONCRETE,GROUTORMORTARISPERMITTEDWHEREITISINSTALLED THEFULLTHICKNESSOFTHEWALLORTHETHICKNESSREQUIREDTOMAINTAINTHEFIRE-RESISTANCERATING;ORii. WHENTHEANNULARSPACEISPROTECTEDWITHMATERIALTHATMEETSASTME119OR UL263.B. PENETRATIONSSHALLBEFIRE-STOPPEDBYASYSTEMINSTALLEDASTESTEDINACCORDANCEWITHASTME814ORUL1479,ANDSHALLHAVEANFRATINGOFNOTLESSTHANTHEREQUIREDFIRE-RESISTANCERATINGOFTHEWALLPENETRATED.(CBC714.4.1.2)C. MEMBRANEPENETRATIONSOFMAXIMUM2-HOURFIRE-RESISTANCERATEDWALLSBYSTEELELECTRICALBOXESAREPERMITTED,PROVIDEDTHATEACHDOESNOTEXCEED16SQUAREINCHESINAREAANDTHETOTALAREAOFSUCHOPENINGDOESNOTEXCEED100SQUAREINCHESFORANY100SQUAREFEETOFWALLAREA,ANDTHESPACEBETWEENTHEWALLMEMBRANEANDTHEBOXDOESNOTEXCEED1/8INCH.ADDITIONALLY,OUTLETBOXESONOPPOSITESIDESOFTHEWALLSHALLBESEPARATEDBYAHORIZONTALDISTANCEOFNOTLESSTHAN24INCHES(CBC714.4.2EXCEPTION1).D. MEMBRANEPENETRATIONSBYLISTEDELECTRICALBOXESOFANYMATERIALAREPERMITTED,PROVIDEDSUCHBOXESHAVEBEENTESTEDFORUSEINFIRE-RESISTANCERATEDASSEMBLIES,ANDTHESPACEBETWEENTHEWALLMEMBRANEANDTHEBOXDOESNOTEXCEED1/8INCHUNLESSLISTEDOTHERWISE.ADDITIONALLY,OUTLETBOXESONOPPOSEDSIDESOFTHEWALLSHALLBESEPARATEDBYAHORIZONTALDISTANCEOFNOTLESSTHAN24INCHES.(CBC714.4.2EXCEPTION2)E. AFIRESPRINKLERSHALLBEPERMITTEDTOBEUNPROTECTEDPROVIDEDSUCHSPACEISCOVEREDBYAMETALESCUTCHEONPLATE.(CBC714.4.2EXCEPTION5)F. WHEREWALLSAREPENETRATEDBYOTHERMATERIALSOROPENINGSLARGERTHANTHOSEMENTIONEDABOVE,THEYMUSTBEQUALIFIEDBYTESTINACCORDANCEWITHCBC714.4.2EXCEPTION2.2. INFIRE-RESISTANCEHORIZONTALASSEMBLIES,DETAILTHROUGHPENETRATIONSANDMEMBRANEPENETRATIONPERCBC714.5ASNOTEDBELOW:A. STEEL,FERROUSORCOPPERCONDUITSMAYPENETRATEFIRE-RESISTANCERATEDFLOORASSEMBLYWHENTHEANNULARSPACEISPROTECTEDWITHMATERIALTHATMEETSASTME119ORUL263(CBC714.5.1EXCEPTION1)B. PENETRATINGITEMS,ASNOTEDABOVE,WITHAMAXIMUM6INCHESNOMINALDIAMETERSHALLNOTBELIMITEDTOTHEPENETRATIONOFASINGLEFIRE-RESISTANCERATEDFLOORASSEMBLY,PROVIDEDTHATTHEAREAOFTHEOPENINGSDOESNOTEXCEED144SQUAREINCHESINANY100SQUAREFEETOFFLOORAREA.(CBC714.4.1.1EXCEPTION1)C. PENETRATIONSSHALLBEFIRE-STOPPEDBYASYSTEMINSTALLEDASTESTEDINACCORDANCEWITHASTME814ORUL1479.THESYSTEMSHALLHAVEANFRATINGANDTRATINGOFNOTLESSTHAN1-HOURBUTNOTLESSTHANTHEREQUIREDFIRE-RESISTANCERATINGOFTHEFLOORPENETRATED(CBC714.5.1)D. MEMBRANEPENETRATIONSBYLISTEDELECTRICALOUTLETBOXESAREPERMITTEDPROVIDEDSUCHBOXESHAVEBEENTESTEDFORUSEINFIRE-RESISTANCERATEDASSEMBLIES,ANDTHESPACEBETWEENTHECEILINGMEMBRANEANDTHEBOXDOESNOTEXCEED1/8INCHESUNLESSLISTEDOTHERWISE.(CBC714.5.2EXCEPTION4)E. AFIRESPRINKLERSHALLBEPERMITTEDTOBEUNPROTECTEDPROVIDEDSUCHSPACEISCOVEREDBYAMETALESCUTCHEONPLATE.(CBC714.5.2EXCEPTION5)3. JOINTSINSTALLEDINORBETWEENFIRE-RESISTANCERATEDWALL,FLOORORFLOOR/CEILINGASSEMBLIESANDROOFSORROOF/CEILINGASSEMBLIESSHALLBEPROTECTEDANAPPROVEDFIRE-RESISTANTJOINTSYSTEMWITHAFIRE-RESISTANCERATINGNOTLESSTHANTHATOFTHEASSEMBLYINWHICHITISINSTALLED.PROVIDEDETAILS(CBC7145.1)4. FIREDOORSANDFIRE-PROTECTIONRATEDGLAZINGSHALLBEARLABELSASREQUIREDBYCBC716.2.9AND716.3.5.5. FIREDAMPERSSHALLBETHEMINIMUMFIREPROTECTIONRATINGSPECIFIEDINCBCTABLE717.3.2.1FORTHETYPEOFPENETRATION(CBC717.3.2.1)REFERTOSPECIFICATIONS260519FORADDITIONALINFORMATION.1. WIRECONNECTORSSHALLBEMINIMUM75DEGREECENTIGRADERATEDANDPROPERLYSIZEDFORTHENUMBEROFCONDUCTORSBEINGCONNECTED,TERMINATED,SPLICED,ETC.ALLABOVEGRADECONNECTORSSHALLBESOLDERLESSLUGORPLASTICWIRENUTTYPE,SCREWON,PRESSURECABLETYPE(WIREUTORSPRINGNUTTYPE)600VOLT,105DEGREEC,WITHSKIRTTOCOVERALLPORTIONSOFSTRIPPEDWIRES.CONNECTORSHALLBEU.L.RATEDFORNUMBERANDSIZEOFCONDUCTORSBEINGJOINEDTOGETHERASSPLICED.2. WIRESANDCABLESFORLINEVOLTAGESYSTEMANDCONTROLS.WIREANDCABLESHALLBECOPPER,600VOLTRATEDTHROUGHOUT.CONDUCTORS14AWGOT10AWG,SOLIDORSTRANDED.CONDUCTORS8AWGANDLARGER,STRANDED3. ALLCONDUCTORSSHALLBECOPPERUNLESSOTHERWISENOTED.MINIMUMSIZEFORINDIVIDUALCONDUCTORSSHALLBE#12AWGUNLESSOTHERWISENOTEDONPANELSCHEDULEORPLANS.SIZE#8AWGANDLARGERSHALLBESTRANDEDCONDUCTOR.INDIVIDUALCONDUCTORSSHALLBEINSULATEDWITHTYPE,XHHW,THW,THHN/THWN600VOLTINSULATIONUNLESSOTHERWISENOTED.4. PROPERINSULATIONTYPESHALLBEUSEDFORTHEPROPERENVIRONMENTALAPPLICATION(I.E.WATERPROOF,WETLOCATION,PLENUMTEMPERATURERATED).ALLCONDUCTORS,WIRINGCABLEWHEREINSTALLEDBELOWFLOOR,SLABORUNDERGROUNDSHALLBECONSIDEREDWETLOCATIONS,ANDSHALLBERATEDACCORDINGLY.NONWATERPROOFCABLINGISNOTALLOWEDINANYBELOWGRADEORWETAPPLICATION.CONDUITSYSTEMSUSEDONTHISPROJECTSHALLBEASFOLLOWS1. PVCSCHEDULE40-underground/belowslabwithGRSelbowsandriserstapewrapped).2. ELECTRICALMETALLICCONDUIT(EMT)-abovegrade/slabinbuildingconstructionandwhereexposedabove8'-0"aff.3. GALVANIZEDRIGIDSTEEL(GRS)-whereexposedbelow8'-0"aff.and/orwheresubjecttophysicaldamage.4. FLEXIBLESTEELCONDUIT-aboveceilingsand/orconcealedinbuildingconstruction(sealtightflexrequiredinexteriorlocations).5. MCCABLEISALLOWED6. ENTISALLOWEDFORLOWVOLTAGESYSTEMSREFERTOSECTION260533&260500OFSPECIFICATIONSFORADDITIONALINFORMATION.CONDUITSSHALLBEMINIMUM3/4"UNLESSOTHERWISENOTEDORCODEREQUIRESLARGERSIZE,1"FORALLHOMERUNCONDUITSANDWHEREROUTEDBELOWSLABORUNDERGROUND.CONDUITSIZES,WHERENOTNOTEDONTHEDRAWINGS,SHALLBESIZEDFORMAXIMUM40%FILLPERCEC310-6.A. PROVIDESEALTITEPOWER&CONTROLCONNECTIONSTOALLACUNITS.B. ALLEQUIPMENTSHOWNABOVEROOFISNEMA3R.C. VERIFYEXACTEQUIPMENTLOCATIONSANDPOINTSOFCONNECTIONWITHMECHANICALCONTRACTORPRIORTOROUGH-IN.D. CONDUITSHOWNISROUTEDINCEILINGSPACEBELOWROOFDECK.E. NOROOFMOUNTCONDUITISALLOWEDUNLESSOTHERWISENOTED.F. FUSEDISCONNECTSWITCHESPEREQUIPMENTNAMEPLATERATING.G. ALLROOFPENETRATIONSSHALLBEMADEWITHROOFJACKS.SEALINGOFALLROOFPENETRATIONSSHALLBEBYTHEROOFINGCONTRACTOR.H. GFCIPROTECTSERVICERECEPTACLESWITHEXTRADUTYCOVERSMUSTBEINSTALLEDWITHIN25FEETOFEQUIPMENT,PERCEC210.63ANDCMC301.4CONDUCTORSANDCABLESROOFPLANNOTESFIREALARMSYSTEM1. PROVIDEALLWORKANDMATERIALREQUIREDFORACOMPLETEANDOPERATINGFIREALARMSYSTEM.WORKSHALLINCLUDE(BUTNOTBELIMITEDTO):A. SHOPDRAWINGSB. SUBMITTALFORAPPROVALC. COMPLETEINSTALLATIONANDTESTINGD. SYSTEMTRAININGFOROWNER'SREPRESENTATIVEE. WARRANTY2. SUBMITASEPARATESETOFDETAILEDFIREALARMPLANS,SPECIFICATIONSANDENGINEERINGCALCULATIONSINCLUDINGBUTNOTNECESSARILYLIMITEDTO:A. CSFMLISTING#'SANDMANUFACTURERMODEL#'SFOREVERYSYSTEMCOMPONENT WHICHISTOBEINTERCONNECTEDASAPARTOFTHISPROJECT.B. SINGLELINE,RISERANDPOINTTOPOINTWIRINGDIAGRAMSINCLUDINGBATTERYAND VOLTAGEDROPCALCULATIONSFORTHEENTIRESYSTEM.C. INDICATIONOFCONDUCTORTYPE(S),POWER-LIMITEDORNON-POWER-LIMITEDSYSTEM.D. SCALEDELEVATIONOFREMOTEGRAPHICANNUNCIATORPANELATENTRY(IFREQUIRED).E. LISTOFPROPOSEDZONESFORALLINITIATINGDEVICES.F. MATRIXOFSYSTEMOPERATION.G. INFORMATIONASREQUIREDTODEMONSTRATECOMPLIANCEWITHAPPLICABLECODE(S)ANDGAINAPPROVALOFAUTHORITY(IES)HAVINGJURISDICTION.FIREALARMSYSTEMINSTALLATIONSHALLNOTBEGINUNTILSEPARATEPERMITHASBEENOBTAINEDANDALLOFTHEABOVEHASBEENACCEPTEDANDSIGNEDBYTHEAUTHORITY(IES)HAVINGJURISDICTIONANDTHEARCHITECT.AFTERCONSTRUCTION,PROVIDEACCURATEFIELDRECORDDRAWINGSTOOWNER.3. ASAMINIMUM,UNLESSOTHERWISENOTED,FIREALARMCONTROLPANELSHALLBEPROVIDEDWITHBATTERYBACKUP,4ZONESAND1SIGNALCIRCUITWITHPROVISIONSFORFUTUREEXPANSION.PROVIDEWITHDIALER(DACT)ANDCONNECTTOCOMMUNICATIONSSYSTEMWITH(2)DEDICATEDVOICELINESASREQUIREDTOSENDSEPARATEANDDISTINCTSIGNALS(ASREQUIREDBYTHEFIREDEPARTMENT)TOANAPPROVEDCENTRALSTATION.FIRESPRINKLERRISERWATERFLOWAND/ORVALVETAMPERSWITCHESSHALLBEPROVIDEDANDINSTALLEDBYTHESPRINKLERSYSTEMCONTRACTOR,ANDWIREDBACKTOTHEFACPBYTHEFIREALARMCONTRACTOR.COORDINATEFORPROPERVOLTAGE.ALLFIREALARMCOMPONENTSSHALLBECALIFORNIASTATEFIREMARSHALLISTED.4. DUCTSMOKEDETECTORSSHALLBEPROVIDEDBYELECTRICALCONTRACTORANDINSTALLEDBYMECHANICALCONTRACTOR.DETECTORPOWERANDSUPERVISORYWIRINGANDCONNECTIONSSHALLBEMADEBYELECTRICALCONTRACTOR.MECHANICALUNITCONTROL(SHUTDOWNUPONDETECTORALARM)WIRINGANDCONNECTIONSSHALLBEMADEBYMECHANICALCONTRACTOR.FIREALARMSYSTEMA. ITSHALLBETHECONTRACTOR'SRESPONSIBILITYTOCONTACTANDCOORDINATEWITHTHESERVINGUTILITYTOENSUREALLSERVINGUTILITYREQUIREMENTSAREMET.B. ALLSWITCHES,CIRCUITBREAKERSANDOTHEREQUIPMENT,ASSPECIFIED,SHALLHAVETERMINATIONPROVISIONSLISTEDANDIDENTIFIEDFORUSEWITH75DEG.CONDUCTORS,ANDALLFEEDERCONDUCTORS,ANDCONDUITS,ARESIZEBASEDONUSEOF75DEG.CCOPPERWIRESTYPESHWN/THHN.C. ALLEQUIPMENTSHALLHAVEANAPPROVEDTESTINGLABORATORYLABELATTACHED[UL,CSA,ETC.](CEC110-2).D. THEELECTRICALCONTRACTORISRESPONSIBLEFORSUPPLYINGSWITCHGEARSIZEDTOFITINTHEAVAILABLESPACE.REFERTOARCHITECTURALPLANSFORDIMENSIONALINFORMATIONNOTSHOWNONTHEELECTRICALPLANS.CONTRACTORSHALLSUBMITA1/4"SCALEDRAWINGOFALLSWITCHGEAR,ANDTERMINATIONCABINETSONFLOORPLANWITHSUBMITTAL.E. ALLBOXESANDENCLOSURES(INCLUDINGTRANSFERSWITCHES,GENERATORS,ANDPOWERPANELS)FOREMERGENCYCIRCUITSSHALLBEPERMANENTLYMARKEDSOTHEYWILLBEREADILYIDENTIFIEDASACOMPONENTOFANEMERGENCYCIRCUITORSYSTEM,PERNEC700-9(A).F. EMERGENCYLIGHTINGSYSTEM(GENERATORANDAUTOMATICTRANSFER)ANDEXITLIGHTSSHALLBECHECKEDANDAPPROVEDBYTHEFIREDEPARTMENTBEFORETHEAPPROVALOFTHEFINALPLANS.G. INACCORDANCEWITHCEC110.16.PROVIDEARCFLASHPROTECTIONWARNINGLABELSONEACHSWITCHBOARD,PANELBOARD,ANDTRANSFORMER.LABELSSHALLBEPERANSIZ535.4GUIDELINES.(SEEDETAIL)H. ALLPANELSAREBOLT-ONBREAKERS.LOADCENTERSARENOTPERMITTED.I. PERCALIFORNIATITLE24SECTION130.5,WIRINGPROVISIONSHAVEBEENMADEFORDISAGGREGATIONOFTHEELECTRICALCIRCUITS,THEOPTIONALMETERINGHASNOTBEENPROVIDEDFORTHISPROJECT.J. REFERTOPANELSCHEDULESFORINDIVIDUALBRANCHCIRCUITVOLTAGEDROPANDSINGLELINEDIAGRAMFORFEEDERVOLTAGEDROPCALCULATIONS.K. BRANCHCIRCUIT/FEEDERDISTANCEISSHOWNFORREFERENCEONLYASTHEBASISOFVOLTAGEDROPCALCULATIONS.CONDUCTORDISTANCEASINDICATEDSHALLNOTBEUSEDFORBIDDING/CONSTRUCTIONPURPOSES.SHOULDTHEFEEDERDISTANCEEXCEEDTHELENGTHNOTEDPERINSTALLATIONCONDITIONS,NOTIFYTHEENGINEEROFRECORD.TYPICAL.L. TRANSFORMERMUSTBEGROUNDEDTOTHESAMEGROUNDINGELECTRODESYSTEMOFTHEBUILDINGPERCEC250.30(A)(4)ANDBONDEDPERCEC250.104(D).M. PRIMARYDISCONNECTNOTLOCATEDWITHINSIGHTOFTRANSFORMERMUSTHAVELOCKINGMEANSOATREMOTEDISCONNECTANDALABELATTRANSFORMERDENOTINGDISCONNECTLOCATIONPERCEC450.14N. METALWATERPIPINGSYSTEMQUALIFYINGASAGROUNDINGELECTRODEPERCEC250.52(A)(1)MUSTBEBONDEDWITHIN5FEETOFENTERINGTHEBUILDINGPERCEC250.68(C)(1).O. ALLSWITCHBOARD,SWITCHGEAR,PANELBOARDS,ANDMOTORCONTROLCENTERSSHALLBELOCATEDINDEDICATEDSPACESANDPROTECTEDFROMDAMAGEPERCEC110.26E(1)AND/OR(2).P. SERVICECONDUCTORSARETOBEOUTSIDETHEBUILDINGPERCEC230.6.Q. ACCESSANDWORKINGSPACEMUSTBEPROVIDEDABOUTELECTRICALEQUIPMENTREQUIRINGOPERATIONANDMAINTENANCEPERCEC110.26R. PROVIDEREQUIREDIDENTIFICATIONOFPOWERSOURCESBEIDENTIFIEDONTHETRANSFORMER(S)WITHPERMANENTPLAQUEINDICATIONLOCATIONOFALLOTHERSOURCESPER230.2(E),700.7,701.7AND702.7SINGLELINEDIAGRAMGENERALNOTESGENERALNOTESCONDUITSYSTEMSNOTESA. ALL15AND20AMPERERECEPTACLESFORBOTHDAMPANDWETLOCATIONSREQUIREDTOBELISTEDWEATHER-RESISTANT(WR)TYPEPERCEC406.9(A)AND(B)B. CEC406.9(A)RECEPTACLESINDAMPLOCATIONS:RECEPTACLESINSTALLEDOUTDOORSINALOCATIONPROTECTEDFROMTHEWEATHERORINOTHERDAMPLOCATIONSSHALLBEANENCLOSUREFORTHERECEPTACLETHATISWEATHERPROOFWHENTHERECEPTACLEISCOVERED(ATTACHMENTPLUGCAPNOTINSERTEDANDRECEPTACLECOVERSCLOSE)C. CEC406.9(B)RECEPTACLESOF15AND20AMP,125AND250VOLTSINSTALLEDINAWETLOCATIONSHALLHAVEANENCLOSURETHATISWEATHERPROOFWHETHERORNOTTHEATTACHMENTPLUGCAPISINSERTED.ANOUTLETBOXHOODINSTALLEDFORTHISPURPOSESHALLBELISTEDANDSHALLBEIDENTIFIEDAS'EXTRA-DUTY"OTHERLISTEDPRODUCTS,ENCLOSURES,ORASSEMBLIESPROVIDINGWEATHERPROOFPROTECTIONTHATDONOTUTILIZEANOUTLETBOXHOODNEEDTOBEMARKED"EXTRADUTY"EXCEPTION:15AND20AMP,125THROUGH250VOLTRECEPTACLESINSTALLEDINAWETLOCATIONANDSUBJECTTOROUTINEHIGH-PRESSURESPRAYWASHINGSHALLBEPERMITTEDTOHAVEANENCLOSURETHATISWEATHERPROOFWHENTHEATTACHMENTPLUGISREMOVED.RECEPTACLESATDAMPANDWETLOCATIONSHEETINDEXEP-001Noreviewnotesforthissheet. ATASCADEROPUBLICSAFETY-POLICESTATION01/20/2025SanLuisObispo,CA93406P.O.Box1167-3562EmpleoSt.THOMAELECTRIC,INC.Phone:(805)543-3850cad@thomaelec.comFax:(805)543-3829ThesedrawingsandspecificationswerepreparedbyThomaElectricspecificallyforthisdesign/buildprojectandshallnotbeusedforbiddingpurposesand/orconstructionbyothers.AlldesignsandinformationshownonthedrawingsareinstrumentsofserviceandarethepropertyofThomaElectric,Inc.Visualcontactwiththeseplansandspecificationsshallconstituteprimafacieevidenceoftheacceptanceoftheserestrictions.ELECTRICALLEGENDANDABBREVIATIONSPOWERLEGENDNOTE:INTERPRETINCONTEXTMISCELLANEOUSCONDUIT/WIRELIGHTFIXTURESCONVENTIONSLEGEND3103NUMBEREDSHEETNOTES:REFERSTONOTESONSAMESHEETASREFERENCEDETAILREFERENCE:Z=DETAILDESIGNATIONX=SHEETNUMBERREFERENCEZXFEEDERSCHEDULEDESIGNATION(EXAMPLE:3103=310AMPERE,600V,3CURRENTCARRYINGCONDUCTORS,PREFIXES:'M'INDICATESMEDIUMVOLTAGE,'CO14'INDICATESCONDUITONLY,QUANTITY(1)ANDSIZE(4"))XMECHANICALSYSTEMSTAG(REFERTOMECHANICALSHEETS)Y=UNITTYPEX=UNITNUMBERYXCOMBINATIONSTARTERMAGNETICCONTACTORDAMPERMOTORHUMIDISTATSURFACEMOUNTCABINETFLUSHMOUNTCABINETSURFACEMOUNTPANELFLUSHMOUNTPANELPUSHBUTTONHMDMCIRCUITBREAKERFUSIBLESWITCHGROUNDTHERMOSTATSURFACEALETTERADJACENTINDICATES(ARROWINDICATESDIRECTION)FIXTURETYPERECESSEDWALLMOUNTEXITLIGHT-CEILINGEXITLIGHT-WALLWALL-PACKCLOCKPHASEØTMOTORUPLIGHT-FLUSHINGRADEPOLELIGHT-DECORATIVEPENDANTLINEARUNDERCABINETLIGHTTANDEM-WIREDLAMPSBOLLARDSTRIPUONDIRECTIONALFLOODEMERGENCYFIXTUREPOLELIGHTTRACKLIGHTCEILINGSURFACEMOUNTWALLSURFACEMOUNTRECESSEDDOWNLIGHTRECESSEDWALLWASHRECESSEDPENDANTMOUNT(E)POWERHOMERUNINDICATESLINECONTINUESWIRELINE-CONTINUESCONDUITSTUB(W/MARKER)VERTICALCONDUITRUNFLEXIBLECONNECTIONSURFACEMOUNTRACEWAYCORDW/PLUGLOWVOLTAGELVCONDUITSEALNEWPOWERHOMERUN(3HOTS&NEUTSHOWN)ISOLATEDGROUNDEXISTINGTOREMAINNEWEUNDERGROUNDWALLMOUNTEDCLOCKCLOCK/SPEAKERCOMBINATIONSSAFETYDISCONNECTENDOFLINERESISTORCHIMEDUCTSMOKEDETECTORVISUAL-VISUALDEVICEMANUALPULLSTATIONHORN-AUDIBLEDEVICEAUDIBLE/VISUALSMOKEDETECTORHEATDETECTORBELLTAMPERSWITCHTPFLOWSWITCHAVVFHFIREALARMCONTROLPANELREMOTEPOWERSUPPLYRPSSPEAKER/VISUALSVFIREALARMSFDSMOKEFIREDAMPERSDCOSDDSDHBCSMOKEDETECTORWITHCOWALLSURFACEMOUNTLINEARTYPELEDCOVE&UNDERCABINETLIGHTPERFIXTURESCHEDULEJJUNCTIONBOXSDVSMOKEDETECTORWITHVISUALA AMPEREAB AMPBREAKERABAND ABANDONEDABV ABOVEAC ALTERNATINGCURRENTAC-# AIRCONDITIONERADJ ADJACENTAF AMPFUSE,AMPFRAMEAFF ABOVEFINISHFLOORAFG BOVEFINISHGRADEAIC AMPERESINTERRUPTINGCAPACITYAl ALUMINUMAS AMPSWITCHRATINGATS AUTOMATICTIMESWITCHATS AUTOMATICTRANSFERSWITCHAV AUDIBLE/AUDIOVISUALAWG AMERICANWIREGAGEBFG BELOWFINISHGRADEBIL BASICIMPULSELEVELBLDG BUILDINGC CONDUIT-C- CATVCONDUITCAB'T CABINETCATV CABLETELEVISIONCB CIRCUITBREAKER,CODEBLUECBC CA.BUILDINGCODECEC CA.ELECTRICALCODECA.ENERGYCOMMISSIONCF COMPACTFLUORESCENTCFC CALIFORNIAFIRECODECLG CEILINGCL CENTERLINECKT CIRCUITCNT'R CONTRACTORC.O. CONDUITONLY(W/PULLROPE)COND CONDUIT,CONDUCTORCR CRITICALBRANCHCSFM CALIFORNIASFMCT CURRENTTRANSFORMERCu COPPERCU-# CONDENSINGUNITD DEPTHDC DIRECTCURRENTDF DRINKINGFOUNTAINDIA DIAMETERDISC DISCONNECTDIST DISTRIBUTIONDPST DOUBLEPOLESINGLETHROWDW DISHWASHEREM EMERGENCY(E) EXISTINGEA EACHEB ELECTRONICBALLASTEC ELECTRICALCONTRACTOREC-# EVAPORATIVECOOLEREF-# EXHAUSTFANEL EVENINGLIGHTELEC ELECTRICALEM EMERGBATTERYBACKUPEMERGENCYBALLASTEMERG EMERGENCYEOL ENDOFLINEEQUIP'T EQUIPMENTES ENERGYSAVING(EXN) (E)IN(N)LOCATION(EXR) (E)TOBE(R)EXT EXTERIORF FLUORESCENT(F) FUTUREF-# FURNACEFA FIREALARMFACP FIREALARMCONTROLPANELFAT FIREALARMTERMINALFAU FORCEDAIRUNITFBO FURNISHEDBYOTHERSFC-# FANCOILFLA FULLLOADAMPSFLR FLOORFLUOR FLUORESCENTFS FUSIBLESWITCHFVNR FULLVOLTAGENON-REVERSINGG GROUNDINGCONDUCTORGC GENERALCONTRACTORGD GARBAGEDISPOSALGFCI GROUNDFAULTCIRCUITINTERRUPTERGFI GROUNDFAULTCIRCUITINTERRUPTERGND GROUNDGRS GALVANIZEDRIGIDSTEELGWS GANGWITHSWITCHH HEIGHT,HIGHHACR HEATING,AC&REFRIGHID HIGHINTENSITYDISCHARGEHO HIGHOUTPUTHOA HAND-OFF-AUTOhp HORSEPOWERHPF HIGHPOWERFACTORHPS HIGHPRESSURESODIUMIC INTERCOMID IDENTIFICATIONIDF INTERMEDIATEDISTRIBUTIONFRAMEIF INSIDEFROSTIG ISOLATEDGROUNDJ-BOX JUNCTIONBOXk QUANTITY1000kVA KILOVOLTAMPSkW KILOWATTLC LIGHTINGCONTACTORLPS LOWPRESSURESODIUMLRA LOCKEDROTORAMPSLS LIFESAFETYBRANCHLT LIGHTLTG LIGHTINGLV LOWVOLTAGEMC MECHANICALCONTRACTORMCA MINIMUMCKTAMPSMCB MAINCIRCUITBREAKERMCTB MAINCATVTERMINALBOARDMCTC MAINCATVTERMINALCABINETMDF MAINDISTRIBUTIONFRAMEMECH MECHANICALMFR MANUFACTURERMFS MAINFUSIBLESWITCHMH METALHALIDEMLO MAINLUGSONLYMOCP MAXIMUMOCPMPOE MINIMUMPOINTOFENTRYMSB MAINSWITCHBOARDMT MOUNTMTHT MOUNTINGHEIGHTMTS MANUALTRANSFERSWITCHMTTB MAINTELEPHONETERMINALBOARDMTTC MAINTELEPHONETERMINALCABINETMW MICROWAVEN NEUTRAL(GROUNDEDCONDUCTOR)(N) NEWN3R NEMA3RNC NORMALLYCLOSEDNEC NATIONALELECTRICALCODENEMA NAT'LELECMANUFACTURER'SASSOCNIC NOTINCONTRACTNL NIGHTLIGHTNO NORMALLYOPENNPF NORMALPOWERFACTORNTS NOTTOSCALEOC ONCENTEROCP OVERCURRENTPROTECTIONOD OUTSIDEDIAMETEROH OVERHEADOSA OFFICEoftheSTATEARCHITECTOSHPD OFFICEofSTATEWIDEHEALTHPLANNING&DEVELOPMENTOVLD OVERLOADP POLEPA PUBLICADDRESSPB PULLBOXPC PULLCHAINPC PHOTOCELLPC PLUMBINGCONTRACTORph PHASEPNL PANELPOC POINTOFCONNECTION-PP- POWERPRIMARY-PS- POWERSECONDARYPV PHOTOVOLTAIC(R) RELOCATE(D)RECEPTRECEPTACLEREF REFRIGERATORREQ'D REQUIREDRLA RATEDLOADAMPSRM ROOMRMC RIGIDMETALCONDUITRMV REMOVERPLC REPLACERS RAPIDSTARTSC SIGNALCABINETSCC SHORTCKTCURRENTSFM STATEFIREMARSHALSHT SHEETSL SLIMLINE,SWITCHLEGSPEC SPECIFICATIONSPST SINGLEPOLESINGLETHROWSQ SQUARESTR'G STORAGESURF SURFACESVC SERVICESW SWITCHT TRANSFORMER,TERMINAL-T- TELEPHONECONDUIT(TBR) TOBEREMOVEDTC TIMECLOCKTEL TELEPHONETELCO TELEPHONECOMPANYTS TIMESWITCHTSO TIMESWITCHOVERRIDETSP TWISTEDSHIELDEDPAIRTTB TELEPHONETERMINALBOARDTTC TELEPHONETERMINALCABINETTX TRANSFORMERTYP TYPICALTYPSIMTYPICALSIMILARUC UNDERCABINET,UNDERCOUNTERUG UNDERGROUNDUGPS UNDERGROUNDPULLSECTIONUL UNDERWRITERSLABORATORIESUON UNLESSOTHERWISENOTEDUSA UGSVCALERT800-642-2444V VOLTVA VOLTAMPERESVAC VOLTALTERNATINGCURRENTVHO VERYHIGHOUTPUTVOLT VOLTAGEVR VANDAL-RESISTANTW WIDTH,WATT,WIREWH-# WATERHEATERWP WEATHERPROOF(NEMA3R)XFMR TRANSFORMER+48 INDICATESMOUNTINGHEIGHTAFFABBREVIATIONS3-WAYSWITCHSINGLEPOLESINGLETHROW(SPST)SWITCHLIGHTINGPOWERBRANCHCIRCUITLINEVOLTAGECEILINGMOUNTEDOCCUPANCYSENSOR,EXTENDEDRANGE360DEGREES,DUALTECHNOLOGY4-WAYSWITCHNETWORKEDLOWVOLTAGE,DUALTECHNOLOGY,CEILINGMOUNT360°OCCUPANCYSENSOR."C"DENOTESCORNERMOUNT.NETWORKED1-POLEWALLSWITCHWITHDUALTECHNOLOGYOCCUPANCYSENSORANDDIMMINGCONTROLLOWVOLTAGECABLINGPERNETWORKEDSYSTEMREQUIREMENTSNETWORKED0-10VDIMMINGRELAYPACKFORLIGHTFIXTURES.COORDINATEDIMMINGTYPEWITHLIGHTFIXTURE.NETWORKEDRELAYPACKFORCONTROLLEDRECEPTACLESPERT24REQUIREMENTS.LOWVOLTAGECEILINGMOUNTEDOCCUPANCYSENSOR,360DEGREES,DUALTECHNOLOGYNETWORKED2CHANNELSWITCHWITHDIMMINGCONTROLNETWORKEDLOWVOLTAGE,DUALTECHNOLOGY,CEILINGMOUNT360°OCCUPANCYSENSORWITHDAYLIGHTHARVESTING.PROGRAMSENSORTOPROVIDESEPARATECONTROLFORPRIMARYANDSECONDARYDAYLITZONES(ASAPPLICABLE).GENERALLIGHTINGPOWERINASSOCIATEDDAYLITZONESHALLBEREDUCEBYAMINIMUMOF65%.NETWORKED4CHANNELSWITCHWITHDIMMINGCONTROL0-10VORPHASEDIMMINGWALLSWITCH(BASEDONFIXTUREREQUIREMENTS)CEILINGFAN/LIGHTCONTROLWALLSWITCHOCCUPANCYSENSOR,2-BUTTON,DUALTECHNOLOGYWALLSWITCHOCCUPANCYSENSOR,2-BUTTON,PASSIVEINFRAREDNETWORKEDSINGLECHANNELSWITCHWITHDIMMINGCONTROLNETWORKEDAUTOMATICDIMMINGCONTROLPHOTOCELL.SINGLEZONECONTROL.PROGRAMTOPROVIDEDIMMINGCONTROLFORDAYLITZONE.GENERALLIGHTINGPOWERINASSOCIATEDDAYLITZONESHALLBEREDUCEDBYAMINIMUMOF65%.0-10VWALLDIMMINGOCCUPANCYWALLSWITCHNETWORKED0-10VDIMMINGUL924COMPLIANTEMERGENCYRELAYPACKFOREGRESSLIGHTFIXTURES.NETWORKEDPHASEDIMMINGRELAYPACKFORLIGHTFIXTURES.COORDINATEDIMMINGTYPEWITHLIGHTFIXTURE.LINEVOLTAGEPOWERSUPPLYVACANCYSENSORWALLSWITCHNETWORKEDHIGHBAY360DEGREESENSOR.PIROCCUPANCYDETECTION.15MINUTEMAXINTERVALTIMERWALLSWITCHOCCUPANCYSENSOR,SINGLEBUTTON,DUALTECHNOLOGYDOUBLEPOLESINGLETHROW(DPST)SWITCHTIMERSWITCHOSLVPSOSTSF/LnDn2Dn4DnOSDW/PILOTLIGHTP432VAD,OSDKEYOPERATEDKW/THERMOOVERLOADTDUALLEVELSWITCHINGLIGHTINGCONTROLSLVNETWORKENABLEDFIXTUREWIRELESSBATTERYPOWEREDWALLDIMMER,1-GANG,4-POLE0-10VDIMMINGD,WSWIRELESSBATTERYPOWEREDWALLDIMMER,1-GANG1-POLE0-10VDIMMINGD,WSa,b,c20ADUPLEXRECEPTACLE20A(GFCI)GROUNDFAULTCURRENTINTERRUPTERDEVICE20AMOUNTABOVECOUNTERPERADA.MOUNTAT+48"MEASUREDTOTOPOFBOX.NEMA3RCOVER(BELL#1503ORENGINEERAPROVEDEQUAL)FLOORMOUNTEDOUTLETGROUNDBAR20ACEILINGMOUNTEDOUTLETGANGWITHSWITCHDISCONNECTFUSEORNONFUSED20DOUBLEDUPLEXRECEPTACLE20A"CONTROLLED"DUPLEXRECEPTACLEPER2022CAENERGYCODEREQUIREMENTS130-5"CIRCUITCONTROLSFOR120VRECEPTACLES"(LEVITON5362-S2X,HEAVYDUTYSPECGRADE;LEVITON16352-WPX)TELEVISIONRECEPT.VERIFYMOUNTINGHEIGHTPRIORTOROUGH-INCOMBINATIONPOWER/DATAFLOORBOX.PROVIDE4-GANGFLOORBOX(POKE-THRU)(WIREMOLDRFB4SERIES),FOR(1)DUPLEXRECEPTACLEAND(1)CONTROLLEDDUPLEXRECEPTACLE,(1)COMMUNICATIONOUTLET,ANDSPARESPACE.CONTRACTORTOPROVIDEALLACCESSORIESFORAWORKINGSYSTEM.DUPLEXRECEPTACLE.REMOVEBREAK-OFFTAB.TOPOUTLETISCONTROLLEDANDBOTTOMOUTLETISUN-CONTROLLED.CONTROLLEDOUTLETSHALLHAVEAPERMANENTMARKINGTODIFFERENTIATETHEMFROMUNCONTROLLEDOUTLETPER2022CAENERGYCODEREQUIREMENTS.(LEVITON5362S1X,HEAVYDUTYSPECGRADE,LEVITON16352-1PX-DECORA)20ASINGLERECEPTACLE20ADUPLEX-HALFSWITCHEDFLOORMOUNT208V,1ØRECEPTACLE20ASWITCHEDRECEPTACLEDROPCORDRECEPTACLE208V1ØRECEPTACLE20AMPDUPLEXOUTLETWITHTYPEAANDTYPECUSBCHARGERNOTE: PROVIDEALLOUTLETSWITHINRESIDENTIALSPACESWITHTAMPERPROOFDEVICESRECEPTACLEWITHINDICATORLIGHT20A(1)CONTROLLEDDUPLEXRECEPTACLEAND(1)DUPLEXRECEPTACLEWHILE-INUSENEMA3RCOVER(TAYMAC#MX4280SORENGINEERAPROVEDEQUALUNLESSOTHERWISENOTED)ARCFAULTCIRCUITINTERRUPTERPROTECTEDRECEPTACLETAMPERPROOFRECEPTACLENEFnOSPCnOSCnPCnOSHnRPPHnRPnRP(ER)nRPT24LIGHTINGFIXTURESCHEDULENETWORKED2CHANNELSWITCHWITHDIMMINGCONTROLANDTUNABLEWHITECONTROLNETWORKED4CHANNELSWITCHWITHDIMMINGCONTROLANDTUNABLEWHITECONTROLNETWORKEDSINGLECHANNELSWITCHWITHDIMMINGCONTROLANDTUNABLEWHITECONTROLnDTn2DTn4DTSITE/EXTERIORLIGHTINGFIXTURESCHEDULETYPE MANUFACTURER CATALOGNO. VOLTAGEMAXVALAMPING MOUNTINGDESCRIPTIONW1MVOLTLED4000KWALL(+8'OAH)EXTERIORWALLLIGHT8-1/2"WX4-3/8"HX4"DEEPDOWNDISTRIBUTIONONLYBLACKFINISH,0-10VDIMMINGINTERIORLIGHTINGFIXTURESCHEDULETYPE MANUFACTURER CATALOGNO. VOLTAGEMAXVALAMPING MOUNTINGDESCRIPTIONF1AMVOLTLED3500KRECESSED 2'X4'TROFFER0-10VDIMMINGTO1%PROVIDEWITH4,000LUMENSPACKAGE.F2MVOLTLED3500KSURFACE 4'LINEARSURFACEMOUNTED,0-10VDIMMINGTO1%F3MVOLTLED3500KWALLLINEARINDIRECT/DIRECT,LENGTHASREQUIREDPERPLANS.(RESTROOM)F7AMVOLTLED3500KRECESSED 4"RECESSEDCANWITHDEEPREFLECTOR,FLANGED0-10VDIMMINGTO1%F11MVOLTLED3500KSURFACE 8'LINEARSURFACEMOUNTED,0-10VDIMMINGTO1%X1MVOLTLEDUNIVERSAL(TOP/END/BACKMOUNT)SINGLEFACEUNIVERSALMOUNTLEDEXITSIGNWITHFIELDSELECTABLECHEVRONS.EXITSIGNFIXTURESCHEDULETYPE MANUFACTURER CATALOGNO. VOLTAGEMAXVALAMPING MOUNTINGDESCRIPTIONEP-002Noreviewnotesforthissheet. ATASCADEROPUBLICSAFETY-POLICESTATION01/20/2025SanLuisObispo,CA93406P.O.Box1167-3562EmpleoSt.THOMAELECTRIC,INC.Phone:(805)543-3850cad@thomaelec.comFax:(805)543-3829ThesedrawingsandspecificationswerepreparedbyThomaElectricspecificallyforthisdesign/buildprojectandshallnotbeusedforbiddingpurposesand/orconstructionbyothers.AlldesignsandinformationshownonthedrawingsareinstrumentsofserviceandarethepropertyofThomaElectric,Inc.Visualcontactwiththeseplansandspecificationsshallconstituteprimafacieevidenceoftheacceptanceoftheserestrictions.ELECTRICALSINGLELINEDIAGRAM(E)'MSB'3(E)800A3P(E)MB(E)M9G350A/3P100KW,125KVA(E)(E)"GEN"1.5KVAEMLTGINVERTER2PGE#10088224714(E)ATS-PD(E)COPPERFEEDERSCHEDULEFEEDERNO.RACEWAYQUANTITY/SIZECONDUCTORS(E)EXISTINGTOREMAIN(E)TOREMAIN202(2)#12THWN&(1)#12GND.(1)3/4"CREFERENCENOTES1. EXISTINGSECONDARYCONDUITSTOREMAINPERPG&E.2. EXISTINGREMOTEMETERTOREMAIN.3. EXISTINGTWO-SECTIONMAINSWITCHBOARD"MSB"(800A,120/208V,3Ø,4W,NEMA1).4. EXISTINGAUTOMATICTRANSFERSWITCH"ATS"TOREMAIN.5. EXISTINGPANELBOARDTOREMAIN.6. PROVIDENEW100A/3PCIRCUITBREAKERTOMATCHEXISTING.7. NEWBRANCHCIRCUITPANELBOARDFORDISPATCHBUILDING.SPACESASNOTED.PROVIDECOPPERBUSSING.8. SURGEPROTECTIONDEVICE"SPD".PROVIDEWITHINTERNALDISCONNECTFORPANELBOARDS.PROVIDEKV/PHASEASSHOWN.9. EXISTINGGENERATOR(100KW/125KVA,120/208V,3Ø,4W,NEMA1)TOREMAIN.10. MANUALTRANSFERSWITCHWITHSEPARATECAMLOCKSTOALLOWFORCONNECTIONTOPORTABLEGENERATOR.800ABUS,120/208V,3PH,4WAVAILABLEFAULTCURRENT42,000A(EST.)225A/3P(E)1PANELG1(E)2304(N)PANELG1A150A(N)3P150A3PMCBSPD160kA/PHASE842SPACE150420256723042304(4)#4/0THWN&(1)#4GND.(1)2-1/2"C1504(4)#1/0THWN&(1)#6GND.(1)2"CEP-003"MTS"10(N)400A,120/208,3Ø,4W,42kAIC,NEMA3R.EMTEMTEMTNote 6 says "100A"MissingPanelSchedulesandLoadCalculationsCall-out at panelsays "150A" "MTS"1(E)"MSB""G1A"(E)"ATS"23ATASCADEROPUBLICSAFETY-POLICESTATION01/20/2025SanLuisObispo,CA93406P.O.Box1167-3562EmpleoSt.THOMAELECTRIC,INC.Phone:(805)543-3850cad@thomaelec.comFax:(805)543-3829ThesedrawingsandspecificationswerepreparedbyThomaElectricspecificallyforthisdesign/buildprojectandshallnotbeusedforbiddingpurposesand/orconstructionbyothers.AlldesignsandinformationshownonthedrawingsareinstrumentsofserviceandarethepropertyofThomaElectric,Inc.Visualcontactwiththeseplansandspecificationsshallconstituteprimafacieevidenceoftheacceptanceoftheserestrictions.ELECTRICALSITEPLANNORTHSCALE:ELECTRICALSITEPLAN1/16"=1'-0"REFERENCENOTES1. E1. EXISTINGMETEREDSERVICEPERSINGLELINEDIAGRAM.SECONDARYCONDUITSAREEXISTINGTOREMAIN.2. OVERHEADFEEDERFROMPANEL"G1"TO"G1A".SEESINGLELINEDIAGRAMFORCONDUITANDFEEDERSIZE.3. OVERHEADCOMMUNICATIONSCONDUITSTONEWDISPATCHBUILDING.SEECOMMUNICATIONSFLOORPLANFORCONDUITQUANTITYANDSIZE.EPS-101Noreviewnotesforthissheet.TOS COMMENT:PLEASE REFER TO TOS COMMENTS PROVIDED ON 5. Scoping Document - PD Narrative - TOS REVIEW AND 6. Scoping Document - PD Drawings - TOS REVIEWFOR THE NEW DISPATCH BUILDING AND THEEXISTING POLICE STATION F11F11F11F2F2F11nOSnRPnOSnOSnOSnDMEN'SLOCKERROOMnRPbnRPEM,anRPcnRPan4DF3-6F7AOSF11T/S105IT104F11F1AF1AnDF1AF1AF1AF1AF1AF1AF1AanOSF1AF1AnDaabbccnOSnRPOFFICE1103BREAK101DISPATCH102HALLWAY100nOSnRPnDnDF11F11F7AF7AF7AF11F3-6nDnOSnRPnOSnOSnOSnRPWOMEN'SLOCKERROOMOSF2F2OSATASCADEROPUBLICSAFETY-POLICESTATION01/20/2025SanLuisObispo,CA93406P.O.Box1167-3562EmpleoSt.THOMAELECTRIC,INC.Phone:(805)543-3850cad@thomaelec.comFax:(805)543-3829ThesedrawingsandspecificationswerepreparedbyThomaElectricspecificallyforthisdesign/buildprojectandshallnotbeusedforbiddingpurposesand/orconstructionbyothers.AlldesignsandinformationshownonthedrawingsareinstrumentsofserviceandarethepropertyofThomaElectric,Inc.Visualcontactwiththeseplansandspecificationsshallconstituteprimafacieevidenceoftheacceptanceoftheserestrictions.LIGHTINGFLOORPLAN1LIGHTINGFLOORPLANSCALE:1/8"=1'-0"REFERENCENOTES1. INTERCEPTEXISTINGCORRIDORLIGHTINGBRANCHCIRCUITANDEXTENDTONEWFIXTURE.PROVIDENEWSURFACEMOUNTFIXTURETOMATCHEXISTING.NOTE: ANYWORKNOTSHOWNONPLANSISCONSIDEREDEXISTINGTOREMAIN.EP-101NOTE: ASSUMESEGRESSLIGHTINGWITHINTHEPDISEXISTINGANDFUNCTIONALTOREMAIN.NOCHANGESTOEGRESSLIGHTINGAREBEINGPROPOSEDWITHINTHEPD.Noreviewnotesforthissheet.TOS COMMENT:PLEASE REFER TO TOS COMMENTS PROVIDED ON 5. Scoping Document - PD Narrative - TOS REVIEW AND 6. Scoping Document - PD Drawings - TOS REVIEWFOR THE NEW DISPATCH BUILDING AND THEEXISTING POLICE STATION TVTVTVTVTVTVTV6(N)"SBB"4321"MTS"(N)"PBB"4(TYPICAL)5(E)"G1"(E)"MSB"(E)"ATS"(E)(E)9MEN'SLOCKERROOMT/S105IT104OFFICE1103BREAK101DISPATCH102HALLWAY100M,G"G1A"M,GM,GWOMEN'SLOCKERROOMM,GGGM,G(N)(N)(N)(N)ATASCADEROPUBLICSAFETY-POLICESTATION01/20/2025SanLuisObispo,CA93406P.O.Box1167-3562EmpleoSt.THOMAELECTRIC,INC.Phone:(805)543-3850cad@thomaelec.comFax:(805)543-3829ThesedrawingsandspecificationswerepreparedbyThomaElectricspecificallyforthisdesign/buildprojectandshallnotbeusedforbiddingpurposesand/orconstructionbyothers.AlldesignsandinformationshownonthedrawingsareinstrumentsofserviceandarethepropertyofThomaElectric,Inc.Visualcontactwiththeseplansandspecificationsshallconstituteprimafacieevidenceoftheacceptanceoftheserestrictions.POWERFLOORPLANREFERENCENOTES1. EXISTINGMETERSERVICEBOARDTOREMAIN.REFERTOSINGLELINEDIAGRAM.2. EXISTINGREMOTEPG&EMETER.3. EXISTINGAUTOMATICTRANSFERSWITCH"ATS".INTERCEPTEXISTINGFEEDERCONDUITFROM"ATS"TOPANEL"G1"ATTHISLOCATIONANDEXTENDNEWFEEDERSFROM"ATS"TOTHEGENERATORCONNECTIONPANEL"GCP"ANDFROM"GCP"TOPANEL"G1".REFERTOSINGLELINEDIAGRAM.4. SECONDARYBONDINGBUSBAR(SBB).5. BONDEACHDISPATCHFURNITURE(TYPICALOF4)WITH(1)#6CUGROUNDWIRINGFROM"SBB".PROVIDE(1)1"C(EMT)WITH(1)#4/0THWNCUGROUNDWIRINGBETWEENGROUNDBARSPERTIA-607E.BENDSOFBONDINGCONDUCTORSTERMINATINGATPBBORSBBSHALLHAVEAMINIMUMINSIDEBENDRADIUSOF8INCHES.6. PROVIDE(2)DEDICATED30A,208VNEMAL6-30RRECEPTACLESABOVEEACHEQUIPMENTRACK(TYPICALOF2).7. EXISTINGPANELTOBERELOCATEDASSHOWN.INTERCEPTANDEXTENDEXISTINGBRANCHCIRCUITSTONEWPANELLOCATION.8. EXISTINGSWITCHTOBERELOCATEDTONEWWALL.INTERCEPTANDEXTENDEXISTING1/2"CONDUITTONEWSWITCHLOCATION.9. NEWFEEDERTOBEROUTEDABOVEACCESSIBLECEILINGWITHINPDANDUTILIZETHEEXISTINGOVERHANGONTHEEXTERIOROFTHEBUILDINGTOTRAVELOVERHEADTONEWDISPATCHBUILDING.1POWERFLOORPLANSCALE:1/8"=1'-0"NOTE: ANYWORKNOTSHOWNONPLANSISCONSIDEREDEXISTINGTOREMAIN.EP-102Noreviewnotesforthissheet.TOS COMMENT:PLEASE REFER TO TOS COMMENTS PROVIDED ON 5. Scoping Document - PD Narrative - TOS REVIEW AND 6. Scoping Document - PD Drawings - TOS REVIEWFOR THE NEW DISPATCH BUILDING AND THEEXISTING POLICE STATIONTOS COMMENT: PLEASE ADD POWER ANDCOMMUNICATION FOR A FULLCONSOLE IN OFFICE 4 4 24TVTVTVTVTVTVTV12121212CAMCAM1MEN'SLOCKERROOMAP2(TYPICAL)T/S105IT104OFFICE1103BREAK101DISPATCH102HALLWAY100WWOMEN'SLOCKERROOMATASCADEROPUBLICSAFETY-POLICESTATION01/20/2025SanLuisObispo,CA93406P.O.Box1167-3562EmpleoSt.THOMAELECTRIC,INC.Phone:(805)543-3850cad@thomaelec.comFax:(805)543-3829ThesedrawingsandspecificationswerepreparedbyThomaElectricspecificallyforthisdesign/buildprojectandshallnotbeusedforbiddingpurposesand/orconstructionbyothers.AlldesignsandinformationshownonthedrawingsareinstrumentsofserviceandarethepropertyofThomaElectric,Inc.Visualcontactwiththeseplansandspecificationsshallconstituteprimafacieevidenceoftheacceptanceoftheserestrictions.COMMUNICATIONSFLOORPLANREFERENCENOTES1. PROVIDE(2)4"AND(2)2"CONDUITS(EMT)FROMRADIOITROOMTONEWDISPATCHITROOM.NEWCONDUITSTOBEROUTEDABOVEACCESSIBLECEILINGWITHINPDANDUTILIZETHEEXISTINGOVERHANGONTHEEXTERIOROFTHEBUILDINGTOTRAVELOVERHEADTONEWDISPATCHBUILDING.2. (2)CAT6ACABLESATTELEVISIONHEIGHT.TELEVISIONANDBRACKETTOBEOWNERFURNISHED,OWNERINSTALLED.COORDINATEROUGH-INWITHTELEVISIONMOUNTING.1COMMUNICATIONSFLOORPLANSCALE:1/8"=1'-0"EP-103NOTE: ANYWORKNOTSHOWNONPLANSISCONSIDEREDEXISTINGTOREMAIN.NOTE: WIRELESSACCESSPOINTS,CAMERAS,ANDINTERCOMSYSTEMSAREBASEDONASTANDALONEUBIQUITIPRODUCT.EQUIPMENTANDINSTALLATIONBYTHOMAELECTRIC,STARTUPANDCOMMISSIONINGOFSYSTEMSBYCITYOFATASCADERO.Noreviewnotesforthissheet.ADD DATA TO THISSIDE OF ROOMTOS COMMENT:PLEASE REFER TO TOS COMMENTS PROVIDED ON 5. Scoping Document - PD Narrative - TOS REVIEW AND 6. Scoping Document - PD Drawings - TOS REVIEWFOR THE NEW DISPATCH BUILDING AND THEEXISTING POLICE STATIONTOS COMMENT: PLEASE ADD TV PER NOTE #2 V15cdV15cdAV30cdSDPC/DACTP 1ANN2WOMEN'SLOCKERROOMMEN'SLOCKERROOMT/S105IT104OFFICE1103BREAK101DISPATCH102HALLWAY100ATASCADEROPUBLICSAFETY-POLICESTATION01/20/2025SanLuisObispo,CA93406P.O.Box1167-3562EmpleoSt.THOMAELECTRIC,INC.Phone:(805)543-3850cad@thomaelec.comFax:(805)543-3829ThesedrawingsandspecificationswerepreparedbyThomaElectricspecificallyforthisdesign/buildprojectandshallnotbeusedforbiddingpurposesand/orconstructionbyothers.AlldesignsandinformationshownonthedrawingsareinstrumentsofserviceandarethepropertyofThomaElectric,Inc.Visualcontactwiththeseplansandspecificationsshallconstituteprimafacieevidenceoftheacceptanceoftheserestrictions.FIREALARMFLOORPLAN1FIREALARMFLOORPLANSCALE:1/8"=1'-0"REFERENCENOTES1. FIREALARMCONTROLPANEL"FACP-PS",CELLULARDIALERANDFIREALARMDOCUMENTATIONCABINET.LABELCABINET,"SYSTEMRECORDDOCUMENTS.2. FIREALARMREMOTEANNUNCIATOR.ANN(30cd)(15cd)FA-DEVICELEGENDAVVHWPFTPSDWEATHER-PROOFHORNCANDELARATINGCANDELARATINGVISUALSW/AUDIBLE/VISUALW/SPRINKLERFLOWSWITCHSPRINKLERTAMPERSWITCHMANUALPULLSTATIONSMOKEDETECTORREMOTEANNUNCIATORFIREALARMCONTROLPANELRMRELAYMODULEC/DACTCELLULARDIALER(30cd)(15cd)AVVCANDELARATINGCANDELARATINGVISUALS-CEILINGW/AUDIBLE/VISUAL-CEILINGW/CCDETECTORCHECKVALVEFIRESPRINKLERDOUBLEDDCVMMMONITORMODULESDDUCTMOUNTEDSMOKEDETECTORD**SEEFIREALARMRISERDIAGRAMFORCOMPETEFIREALARMLEGEND10-MTENINPUTMONITORMODULEDMDUALMONITORMODULEFIREALARMBELLBEP-104NOTE: FIREALARMSYSTEMWITHINTHEPDISEXISTINGTOREMAIN.NOREVISIONSAREBEINGPROPOSEDFORTHEEXISTINGSYSTEM.Noreviewnotesforthissheet.TOS COMMENT:PLEASE REFER TO TOS COMMENTS PROVIDED ON 5. Scoping Document - PD Narrative - TOS REVIEW AND 6. Scoping Document - PD Drawings - TOS REVIEWFOR THE NEW DISPATCH BUILDING AND THEEXISTING POLICE STATION 3562 Empleo St., San Luis Obispo, CA 93401 Dept. of Industrial Relations #1000000812 Contractor’s License # (C-10) 274276 (805) 543-3850 FAX (805) 543-3829 mwestley@thomaelec.com Page 1 of 5 March 12, 2025 Proposal for Electrical Work To: F&H Construction Attn: Stephen Seibly Re: Atascadero Public Safety Improvements, Atascadero, CA _______________________________________________________________________________________________________________________________________ Thoma Electric, Inc. proposes to furnish labor, materials, and equipment to perform the electrical scope of work for the above project per Thoma Electric provided plans with plot date of 3/10/2025 for FS1 and PD and a plot date of 3/6/25 for FS2, with qualifications as follows: Qualifications: As a result of significant Value Engineering exercises between Thoma Electric, the City of Atascadero, and F&H Construction, all entities recognize that pricing included herein incorporates substantial deviations from originally issued RFP documents and issued Addenda in recognition that such deviations were necessary for achieving the City’s overall budget. This proposal assumes that all such deviations, including those made by Thoma Electric as reasonable for the type and scope of this project, have been reviewed and accepted by the City of Atascadero and F&H Construction and the resulting basis of design. As such, the submittal plans as attached hereto via Exhibit A and the clarifications/assumptions/exclusions in this proposal as well as Exhibit B shall be the governing documents regarding electric scope of work to be performed. Inclusions: · Disconnection of power for demolition work by others. · Temporary power and lighting at each site and temporary power connection to one trailer at one of the three sites. Phone/data/CATV or any other low voltage system is excluded. · Trenching and backfill for site electrical work performed under this proposal. · Concrete transformer pad and primary junction pad at Fire Station 1. · Provide and install Title 24 compliant lighting and controls at all new and remodeled spaces. · Provide and install new site lighting as indicated on plans at Fire Station 1 and Fire Station 2. · New main electrical service at Fire Station 1 and relocation of existing electrical service at Fire Station 2. · New natural gas generator, concrete pad, protective bollards (as required), and automatic transfer switch to back up the entire facility at Fire Station 1 and partial backup of the facility at Fire Station 2 (Police Department will utilize existing generator). · New generator connection panel for connection to a portable generator (provided by others) at each site for backup of those loads that have been selectively backed up by generator at each site (see above). · Provide and install new Video Monitoring System at exterior entries to Fire Station 1 as indicated on plans, basis of design is Ubiquiti, equipment/installation to be provided by Thoma, equipment to be commissioned by Atascadero City IT (see commissioning exclusion below). · Provide and install new video intercom devices at Fire Station 1 gates for remote operation at the EOC, basis of design is Ubiquity, equipment/installation to be provided by Thoma, equipment to be commissioned by Atascadero City IT (see commissioning exclusion below). · Provide and install new data communications wiring and pathways at new and remodeled spaces. · Provide and install new tone-based Fire Station Alerting system at Fire Station 1 and Fire Station 2. · New Fire Alarm System at Fire Station 1, Fire Station 2, and the new Dispatch building at PD. · PV system at new Fire Station 1 as indicated on Thoma Electric single line. · DAS/ERRCS survey at each site (if survey determines that these systems are needed additional charges will apply.) · The services of a Licensed Professional Engineer to produce drawings for permit. · Applicable sales tax (expressly excludes other duties, tariffs, or government imposed charges which shall be passed through to client. 3562 Empleo St., San Luis Obispo, CA 93401 Dept. of Industrial Relations #1000000812 Contractor’s License # (C-10) 274276 (805) 543-3850 FAX (805) 543-3829 mwestley@thomaelec.com Page 2 of 5 Exclusions: · On-site fuel storage for new generators (this is not required if a generator connection panel is provided). · 2-hour rated feeders at any facility. · Innerduct in any low voltage conduit. · Concrete encasement of any underground conduit (except at Thoma Electric’s discretion). · Battery Energy Storage System (BESS) at any site. · Variable Frequency Drive (VFD) procurement and installation. Line voltage connection included. · Base radio and City or County radio systems and provisioning, commissioning, etc. of such systems, assumes to be performed by City of Atascadero. · Dispatch stations, Dispatch monitors, CAD system, radio systems, antennas, antenna mounting infrastructure or integration of such systems. · AV systems including speakers, microphones, cameras, touch panels, displays, & TV’s. · Assistive listening system (if required). · Commissioning of Wireless Access Points, Video Surveillance, Intercom systems. Assumes that Thoma will provide equipment, connectivity, structured cabling, rough-in, and that City of Atascadero will provide startup and integration with such systems to their own IT facilities as necessary. · Hood controls and or interconnection wiring including Ansul system, if required. · Permits and fees, and utility company fees and charges. · Bond premium. If required, our bond rate is approximately 1%. · Power and low voltage provisions for relocation of any personnel, equipment, or systems to accommodate temporary relocation of City staff during construction. · Any scope of work that is not explicitly included above or explicitly included in the attached drawing sets (Exhibit A). Refer to additional clarifications/assumptions/exclusions in Exhibit B. Exclusions Continued (assumed to be covered by General Contractor) · Removal of trenching spoils from site. Assumes spoils can be stored on site for re-use or disposal by others. · Natural gas supply line and connection for all generators. · Mechanical controls, plumbing controls, irrigation controls, EMS, and BMS in their entirety. · Concrete housekeeping pads at electrical equipment. (Other than Generators and Utility provided equipment.) · Seismic restraint wires for light fixtures (normally provided by acoustic ceiling contractor). · Sealing of roof penetrations; assumes this work will be by the roofing contractor. · Framing for support of light fixtures, panels, or other electrical materials. · Fire rated assemblies and enclosures (sheetrock backing at panels, sheetrock “boxes” for fire rating around light fixtures, enclosures, etc.). · Fire smoke dampers and duct smoke detector procurement and installation. Power and fire alarm connections are included as needed. · Access hatches in hard lid ceilings. · Electrified door hardware at any doors. · Painting. · Overtime. This proposal is based on all work being performed during our normal business hours between 7:00 a.m. to 3:30 p.m., Monday through Friday. · Bond premium. If required, our bond rate is approximately 1%. 3562 Empleo St., San Luis Obispo, CA 93401 Dept. of Industrial Relations #1000000812 Contractor’s License # (C-10) 274276 (805) 543-3850 FAX (805) 543-3829 mwestley@thomaelec.com Page 3 of 5 Clarifications: · Pricing is based on Fire Station 1 being complete by March of 2027, Police Department being complete by October 2026 and Fire Station 2 being complete by July 2026. · Assumes existing IT room has sufficient backup power to facilitate existing dispatch operations. Excludes additional generator power receptacles in this room. · Assumes Builder's Risk Insurance is paid for and covered by the General Contractor or Owner. · Our Bid is conditioned on: A mutually acceptable form of Purchase Order or contract document. Please note carefully the Inclusions, Exclusions, and Clarifications contained in this proposal, as Thoma Electric will require this proposal, and any Exhibits attached hereto, to be attached to any contract offered by you as our complete Scope of Work. · This pricing may be withdrawn by us if not accepted within (60) days. · In the event of a Force Majeure Event, the obligations of the parties and the time period for the performance of such obligations shall be adjusted to the extent such parties are prevented or hindered. The affected party shall give prompt, written notice of such Force Majeure Event to the other party. A Force Majeure Event shall mean any one or more of the following events that adversely affects the operation of either party under this Agreement including but not limited to fire, earthquake, storm, labor interruptions, any act or omission of any government authority, civil unrest, material shortages and/or delivery delays through standard supply chains; tariffs, duties, import/export fees, or other similar government-imposed charges, or any other event beyond the Parties’ reasonable control. Further, Subcontractor shall be permitted to adjust any pricing, costs or fees quoted in any bid, proposal, quotation, or at any time during performance of the scope of work, due to the occurrence of a Force Majeure Event and pass such adjusted cost, fee, duty, or charge through. Atascadero Fire Station #1 - Scoping Documents CommentsComment NO.Date ReceivedBuilding Document Page Drawing Section/TopicCommentGraphicResponsibilityDBE ResponseCity ResponseDBE / Review Item Discussion1 3/18/2025 Fire Station #1 Narrative1 Demolition ScopeContractor to please expand on the demolition scope for the site and what will remain in place and be protected. NoneF&HA site survey will be needed in order to complete this task. Will be addressed during the design. Currently only utilities needed for the new construction will remain and be protected. Agree2 3/18/2025 Fire Station #1 Narrative1 FF&E PackageVanir to review FF&E lists and share with F&H team to confirm contractor scope of work. NoneF&HNeed the updated FF&E lists, based on the VE discussed & direction, in order to comment.List provided, coordinate between City and F&HSee revised FF&E list.3 3/18/2025 Fire Station #1 Narrative1 Paragraph 7Add "fire administrative offices" after "The new building will include"…NoneF&HWill edit & change wordingProvide document for confirmationCONFIRMED4 3/18/2025 Fire Station #1 Narrative1 Paragraph 7Replace "apparatus bay" with "a three-bay drive through apparatus bays with stacked parking for 5 vehicles".NoneF&HWill edit & change wordingProvide document for confirmationCONFIRMED5 3/18/2025 Fire Station #1 Narrative1 Paragraph 8Add bullet point: "The existing emergency generator is to be salvaged and provided to the City."NoneF&HWill edit & change wordingProvide document for confirmationCONFIRMED6 3/18/2025 Fire Station #1 Narrative1 Paragraph 8Add bullet point: "Contractor to please salvage the existing flagpole monument plaque for re-use. Please coordination with the FD on new location"NoneF&HWill edit & change wordingProvide document for confirmationCONFIRMED7 3/18/2025 Fire Station #1 Narrative1 Paragraph 8DBE to coordinate with the City team on where these salvaged items are to be delivered.NoneF&HThis can be reviewed, coordinated, and adjusted during the design phase. F&H does not anticipate this comment to have a cost impact.Agree8 3/18/2025 Fire Station #1 Narrative2 Paragraph 1This is a very broad statement and should be updated to align with the scoping drawing package and FF&E lists. NoneF&HNot sure how to answer this as we have not seen an updated FF&E list based on the revised VE and requested changes.List provided, coordinate between City and F&HSee revised FF&E list.9 3/18/2025 Fire Station #1 Narrative2 DemolitionContractor to please expand on the demolition scope for the site and what will remain in place and be protected. NoneF&HSame comments as item #1Agree10 3/18/2025 Fire Station #1 Narrative2 Interior Architectural Woodworking & Casework - Bullet 7Add: Counter to decontamination area cabinet. This should be covered by FF&E?NoneF&HThis was edited based on changes requested during the negotiation phase. This item remained in budget comments & is part of F&H's scope.Agree11 3/18/2025 Fire Station #1 Narrative2 Interior Architectural Woodworking & Casework - Bullet 9Request that DB team be specific with NIC statements with naming each space where casework will not be included, so we can align with FF&E lists.NoneF&HThis was edited based on changes requested during the negotiation phase. The LDA scoping drawings show the cabinets to remain that are part of F&H's scope. We should change the "Wall Finishes" drawings to read "Wall Finishes & Cabinets"List provided, coordinate between City and F&HSee revised FF&E list.12 3/18/2025 Fire Station #1 Narrative3 RoofingConfirm Class A roofing materials and length of warranties. NoneF&HClass A PVC Roofing Membrane w/ 30 year warranty per original RFPAgree13 3/18/2025 Fire Station #1 Narrative3 RoofingConfirm minimum metal gauge.NoneF&HPer original RFPAgree14 3/18/2025 Fire Station #1 Narrative3 Doors, Frames, Windows, & Hardware - Bullet 3Please confirm apparatus bay door types. Original RFP had 4 fold bi-fold doors on the front and rapid coiling overhead doors at the rear.NoneF&HThis can be reviewed, coordinated, and adjusted during the design phase. F&H does not anticipate this comment to have a cost impact.City understands this to mean that bi-fold and rapid coiling doors can be included at the base cost. F&H confirmConfirmed, the budget includes per the RFP15 3/18/2025 Fire Station #1 Narrative3 Doors, Frames, Windows, & Hardware - Bullet 5-7Please confirm material type for doors and windows. NoneF&HStandard doors, frames & hardware be coordinated with the City during the design phase. Doors & frames can be wood or metal, window frames either steel or aluminum depending on location. All ballistics ratings were removed during VEAgree16 3/18/2025 Fire Station #1 Narrative3 Finishes - Bullet 5Larger tiles and less grout lines are preferred for maintenance.NoneF&HThis can be reviewed, coordinated, and adjusted during the design phase. F&H does not anticipate this comment to have a cost impact.Agree17 3/18/2025 Fire Station #1 Narrative3 Finishes - Bullet 6-9Please refer to the drawings for comments on flooring and ceiling materials.NoneF&HComments on drawings addressed below.Agree18 3/18/2025 Fire Station #1 Narrative3 Miscellaneous items - Bullet 1 Suggest changing language (for ADA) to all code required signage for permitting.NoneF&HWill adjust during design phaseAgree19 3/18/2025 Fire Station #1 Narrative3 Miscellaneous items - Bullet 3 Bench in RR is also an ADA requirementNoneF&HAcknowledgedAgree20 3/18/2025 Fire Station #1 Narrative3 Miscellaneous items - Bullet 5 25 Standard Lockers: Where are these located? Are these the hygiene lockers?NoneF&HPer RFP requirements, confirm location and design with City during design phase.Agree21 3/18/2025 Fire Station #1 Narrative3 Miscellaneous items - Bullet 5 24 Turnout Lockers: Programming called for 26. Lockers be 36" wide to fit the out of county bags on the top shelf.NoneLDA24 was minimum required by Chief & coordinated during VE discussion. We can review and adjust during design.Agree22 3/18/2025 Fire Station #1 Narrative3 Miscellaneous items Please confirm if there is a monument sign included in the scope of work.NoneF&HNo monument sign is included. Signage on the building is included.Agree23 3/18/2025 Fire Station #1 Narrative4 Site Development - Bullet 4Confirm if the screening is fabric or vinyl slats. NoneF&HWill coordinate with City to determine their preference. Not cost impact is anticipated.Agree Atascadero Fire Station #1 - Scoping Documents CommentsComment NO.Date ReceivedBuilding Document Page Drawing Section/TopicCommentGraphicResponsibilityDBE ResponseCity ResponseDBE / Review Item Discussion24 3/18/2025 Fire Station #1 Narrative4 Site Development - Bullet 5The whole site will be disturbed on this project. Please update this statement.NoneF&HThe site and including off-site items will be disturbed & the wording as currently shown should remain.Agree25 3/18/2025 Fire Station #1 Narrative4 Site Development - Bullet 9Suggest changing language to all required permits shall be paid for by the City.NoneF&HWill edit & change wordingProvide document for confirmationCONFIRMED26 3/18/2025 Fire Station #1 Narrative4 General Conditions & Miscellaneous Project Items - Bullet 1Vanir - OKNoneF&HAcknowledgedAgree27 3/18/2025 Fire Station #1 Narrative4 General Conditions & Miscellaneous Project Items - Bullet 5Vanir/F&H to reviewNoneF&HTeam to collaborate on revised language.Pending final languageThe revised wording provided today (4/9/2025) is acceptable to F&H. Thank you!28 3/18/2025 Fire Station #1 Drawings1 Site PlanPlease change gate to rolling and eliminating swing gates.F&HThis can be reviewed, coordinated, and adjusted during the design phase. F&H does not anticipate this comment to have a cost impact.Agree29 3/18/2025 Fire Station #1 Drawings1 Site PlanCity FD has requested that a "LEEP CLEAR" zone be labeled and striped.F&HThis can be reviewed, coordinated, and adjusted during the design phase. F&H does not anticipate this comment to have a cost impact.Agree30 3/18/2025 Fire Station #1 Drawings1 Site PlanPlease change gate to rolling and eliminating swing gates.F&HThis can be reviewed, coordinated, and adjusted during the design phase. F&H does not anticipate this comment to have a cost impact.The biggest issue with this change is dealing with the driveway elevation change due to required slope. By turning the trash enclosure in this direction could lead to the driveway being completely blocked when trash is being picked up.Agree31 3/18/2025 Fire Station #1 Drawings1 Site PlanPlease rotate trash enclosure.F&HRefer to previous noteAgree32 3/18/2025 Fire Station #1 Drawings1 Site PlanCity Planning to review if screen wall is needed to hide the emergency generator.F&HThis can be reviewed, coordinated, and adjusted during the design phase. F&H does not anticipate this comment to have a cost impact.Agree33 3/18/2025 Fire Station #1 Drawings1 Site PlanPlease confirm if there is a back-up propane fuel tank for the generator if required to meet the essential services act.F&H / ThomaPlease refer to Addendum #4 of the RFP under the section "Emergency Power System for Essential Services Facilities". This was also further addressed in Thomas Clarifications under item #49 and #50 as it relates to Fire Station #1 & #2. Agree34 3/18/2025 Fire Station #1 Drawings2 Floor Plan - First FloorTurnout 2Only 24 lockers are shown. Program requires 26. Contractor to confirmLDA24 was minimum required by Chief & coordinated during VE discussion. We can review and adjust during design.Agree35 3/18/2025 Fire Station #1 Drawings2 Floor Plan - First FloorEliminate door or use for turnout washer access to rear for maintenanceLDAThis can be reviewed, coordinated, and adjusted during the design phase. Agree - this should be a cost savings36 3/18/2025 Fire Station #1 Drawings2Floor Plan - First FloorPlease show location for turnout washer with sump drain. LDAThis can be reviewed, coordinated, and adjusted during the design phase. Agree - at no additional cost37 3/18/2025 Fire Station #1 Drawings2 Floor Plan - First FloorSCBAPlease confirm that access to all panels on the (e) Bauer compressor can be achieved with placement F&HThis is being salvaged and reinstalled at this location. Please provide data and information on the exact unit so that we can coordinate in design.Agree Atascadero Fire Station #1 - Scoping Documents CommentsComment NO.Date ReceivedBuilding Document Page Drawing Section/TopicCommentGraphicResponsibilityDBE ResponseCity ResponseDBE / Review Item Discussion38 3/18/2025 Fire Station #1 Drawings2 Floor Plan - First FloorExercisePlease consider roll up door hereF&HThis can be reviewed, coordinated, and adjusted during the design phase. F&H anticipates that this may have a cost impact. F&H will work with the team to mitigate or offset any cost impact during the design phase.Agree39 3/18/2025 Fire Station #1 Drawings2 Floor Plan - First FloorStorageMezzanine storage has been moved to the ground floor. Space will need to be conditioned for storing PPE.Please provide a space for yard equipment storage. F&HWe will coordinate with Boneso for the conditioning of the space. Not sure what yard equipment is being referred to in this comment.New PPE storage is needed and should be temperature controlled for longevity and protection of supplies. A separate yard equipment storage area is needed for yard maintenance such as rakes, shovels, etc and does not require temperature control40 3/18/2025 Fire Station #1 Drawings2 Floor Plan - First FloorMechUpdate Room Name.LDAThis can be reviewed, coordinated, and adjusted during the design phase. Agree41 3/18/2025 Fire Station #1 Drawings2 Floor Plan - First FloorHoseHose is an alcove. Do not need doors or wall at hallway. Framed opening to FD's preferenceF&HThis can be reviewed, coordinated, and adjusted during the design phase. F&H does not anticipate this comment to have a cost impact.Agree - this should be a cost savings.42 3/18/2025 Fire Station #1 Drawings2 Floor Plan - First FloorTurnoutArchitect to confirm that NFPA requirements for turnout room can be met with without doors separating the turnout spaceF&HThis can be reviewed, coordinated, and adjusted during the design phase. F&H does not anticipate this comment to have a cost impact.Agree - this is a code requirement with no additional cost43 3/18/2025 Fire Station #1 Drawings2 Floor Plan - First FloorShopDo not need doors. Framed opening to FD's preferenceF&HThis can be reviewed, coordinated, and adjusted during the design phase. F&H does not anticipate this comment to have a cost impact.Agree - this should be a cost savings44 3/18/2025 Fire Station #1 Drawings2 Floor Plan - First FloorShopNeeds space for rolling tool chest and full height hazmat cabinetF&HThe layout of FF&E items such as storage shelving, HazMat cabinets & tool chests to be coordinated during the designAgree45 3/18/2025 Fire Station #1 Drawings2 Floor Plan - First FloorApp BayContractor to confirm front app bay door type. Opening speed and low maintenance are the two prioritiesNoneF&HThis can be reviewed, coordinated, and adjusted during the design phase. F&H does not anticipate this comment to have a cost impact.City understands this to mean that bi-fold and rapid coiling doors can be included at the base cost. F&H confirmConfirmed, the budget includes per the RFP46 3/18/2025 Fire Station #1 Drawings2 Floor Plan - First FloorApp BayVerify 20' min for clear height in app bays NoneLDAThis can be reviewed, coordinated, and adjusted during the design phase. F&H does not anticipate this comment to have a cost impact.Agree47 3/18/2025 Fire Station #1 Drawings2 Floor Plan - First FloorApp BayHERE IS THE LINK TO THE HORMANN ROLL UP SPEED DOORS AS AN ALTERNATIVE TO THE BIFOLD: https://www.hormann.us/high-performance/rigid-doors/speed-guardian-5000-lp-42/NoneF&HThis can be coordinated during design. We are following the RFP documents but will work with the City during the design meetings City understands this to mean that bi-fold and rapid coiling doors can be included at the base cost. F&H confirmConfirmed, the budget includes per the RFP Atascadero Fire Station #1 - Scoping Documents CommentsComment NO.Date ReceivedBuilding Document Page Drawing Section/TopicCommentGraphicResponsibilityDBE ResponseCity ResponseDBE / Review Item Discussion48 3/18/2025 Fire Station #1 Drawings2 Floor Plan - First FloorDeconMissing freestanding two compartment clean up sink with drainboards and hazmat bins in DECONF&HThis can be reviewed, coordinated, and adjusted during the design phase. F&H does not anticipate this comment to have a cost impact. We will review the RFP documents and make sure we meet the City's requirements in this roomAgree49 3/18/2025 Fire Station #1 Drawings2 Floor Plan - First FloorDeconPlease consider and provide access to the hallway and pathway to the laundry for decon of clothing from this space. F&HThis can be reviewed, coordinated, and adjusted during the design phase. F&H does not anticipate this comment to have a cost impact.Agree50 3/18/2025 Fire Station #1 Drawings2 Floor Plan - First FloorDeconPlease consider adding door, so personnel do not have to re-enter hot zone after decon.F&HThis can be reviewed, coordinated, and adjusted during the design phase. F&H anticipates that this may have a cost impact. F&H will work with the team to mitigate or offset any cost impact during the design phase.Agree51 3/18/2025 Fire Station #1 Drawings2 Floor Plan - First FloorDeconPlease show freestanding stainless steel clean-up sink with drainboards and plumbing fixtures per program. F&HSame question as item #48?Agree52 3/18/2025 Fire Station #1 Drawings2Floor Plan - First FloorMissing location for ice machine. Prefer a clean location. Not in the app bays.NoneF&HThis can be reviewed, coordinated, and adjusted during the design phase. F&H does not anticipate this comment to have a cost impact.Agree53 3/18/2025 Fire Station #1 Drawings2 Floor Plan - First FloorHallwayProvide 2 doors into this space. Regular users will be the Admin folksF&HThis can be reviewed, coordinated, and adjusted during the design phase. F&H anticipates that this may have a cost impact. F&H will work with the team mitigate or offset any cost impact during the design phase.Agree54 3/18/2025 Fire Station #1 Drawings2 Floor Plan - First FloorElectricalPlease consider moving these doors to provide more wall space and access street for maintenance in the electrical roomF&HThis can be reviewed, coordinated, and adjusted during the design phase. F&H does not anticipate this comment to have a cost impact.This will need to be coordinated with Thoma Electric as needed for their equipment & systems.Agree55 3/18/2025 Fire Station #1 Drawings2Floor Plan - First FloorPlease consider moving these doors apart, so that casework and displays can be in the middle. This seems like the only space that will be able to fit anythingF&HThis can be reviewed, coordinated, and adjusted during the design phase. F&H does not anticipate this comment to have a cost impact.Agree56 3/18/2025 Fire Station #1 Drawings2 Floor Plan - First FloorBreakout RoomSeats fewer people than program calls for (10).F&HThis can be changed by editing the layout of the table shown but will work with the City & LDA on the final layout and size of the roomAgree Atascadero Fire Station #1 - Scoping Documents CommentsComment NO.Date ReceivedBuilding Document Page Drawing Section/TopicCommentGraphicResponsibilityDBE ResponseCity ResponseDBE / Review Item Discussion57 3/18/2025 Fire Station #1 Drawings2 Floor Plan - First FloorAdminPlease show public counter and window.F&HThis can be reviewed, coordinated, and adjusted during the design phase. F&H does not anticipate this comment to have a cost impact.Agree58 3/18/2025 Fire Station #1 Drawings2 Floor Plan - First FloorStairsArchitect to review location of these stairs for exiting and connection to the app bay for turnout time efficienciesF&HThis can be reviewed, coordinated, and adjusted during the design phase. F&H anticipates that this may have a cost impact if there is significant floorplan change. F&H will work with the team to mitigate or offset any cost impact during the design phase.The stair locations were commented on since the confidential meetings and the request for the design team to address was made so there would be no cost impacts. This should be a no cost item to be reviewed during design.59 3/18/2025 Fire Station #1 Drawings2 Floor Plan - First FloorJanitorPlease show location of mop sinkF&HThis can be reviewed, coordinated, and adjusted during the design phase. F&H does not anticipate this comment to have a cost impact.Agree60 3/18/2025 Fire Station #1 Drawings2 Floor Plan - First FloorRestroomPlease confirm that (5) Full height lockers for command staff are includedF&HLocker quantity and type will be per the RFP documents and located during design as coordinated with the CityAgree61 3/18/2025 Fire Station #1 Drawings2 Floor Plans MiscellaneousFF&E items should be shown all the same. There is casework that is still shown in contract graphically and does not align with narrative or the City's FF&E Lists. Please update so we can confirm and finalize the City's FF&E listsF&HThis was edited based on changes requested during the negotiation phase. The LDA scoping drawings show the cabinets to remain that are part of F&H's scope. We should change the "Wall Finishes" drawings to read "Wall Finishes & Cabinets" as this shows the cabinets to remain and doesn't show the FF&E items.List provided, coordinate between City and F&HSee revised FF&E list.62 3/18/2025 Fire Station #1 Drawings2 Floor Plan - Second FloorStairsArchitect to review location of these stairs for exiting and connection to the app bay for turnout time efficienciesF&HThis can be reviewed, coordinated, and adjusted during the design phase. F&H anticipates that this may have a cost impact if there is significant floorplan change. F&H will work with the team to mitigate or offset any cost impact during the design phase.The stair locations were commented on since the confidential meetings and the request for the design team to address was made so there would be no cost impacts. This should be a no cost item to be reviewed during design.63 3/18/2025 Fire Station #1 Drawings2 Floor Plan - Second FloorRestroomsPlease show location of the hygiene lockers and benches shownF&HLocker quantity and type will be per the RFP documents and located during design as coordinated with the City . . . LDA to commentAgree64 3/18/2025 Fire Station #1 Drawings2 Floor Plan - Second FloorBedroom 6Double occupancy bunk room requires space for 6 wardrobe lockers. Please confirm. F&HThis can be reviewed, coordinated, and adjusted during the design phase. F&H does not anticipate this comment to have a cost impact.Agree65 3/18/2025 Fire Station #1 Drawings2 Floor Plan - Second FloorLaundry/Jan StorageThese could be combined into one space.F&HThis can be reviewed, coordinated, and adjusted during the design phase. F&H anticipates that this may have a cost impact. Agree - this should be a cost savings66 3/18/2025 Fire Station #1 Drawings2Floor Plan - Second FloorThere is no coffee station space shownNoneLDAThis can be reviewed, coordinated, and adjusted during the design phase. F&H does not anticipate this comment to have a cost impact.Agree Atascadero Fire Station #1 - Scoping Documents CommentsComment NO.Date ReceivedBuilding Document Page Drawing Section/TopicCommentGraphicResponsibilityDBE ResponseCity ResponseDBE / Review Item Discussion67 3/18/2025 Fire Station #1 Drawings3 Reflected Ceiling Plan - First FloorIDFCity IT prefers acoustical ceilings in the IDF and IT spaces.F&HThis can be reviewed, coordinated, and adjusted during the design phase. F&H does not anticipate this comment to have a cost impact.Agree68 3/18/2025 Fire Station #1 Drawings3 Reflected Ceiling Plan - First FloorEOC Storage & StorageCity prefers gyp board ceiling.F&HThis can be reviewed, coordinated, and adjusted during the design phase. F&H does not anticipate this comment to have a cost impact.Agree69 3/18/2025 Fire Station #1 Drawings3 Reflected Ceiling Plan - First Floor Two types of acoustical ceiling tile sizes. City prefers only one size be used.NoneF&HWe will work with the City to coordinate & may want to look at a second look tile that all appear to be 2x4 but look like a 2x2 tile.Agree70 3/18/2025 Fire Station #1 Drawings3 Reflected Ceiling Plan - Second FloorLaundry/Jan StorageCity prefers gyp board ceiling.F&HThis can be reviewed, coordinated, and adjusted during the design phase. F&H does not anticipate this comment to have a cost impact.Agree71 3/18/2025 Fire Station #1 Drawings4 Floor Finishes Plans - First FloorR.R. ShowerEpoxyF&HThis can be reviewed, coordinated, and adjusted during the design phase. F&H anticipates that this may have a cost impact. F&H will work with the team mitigate or offset any cost impact during the design phase.We can discuss & coordinate with the City. Many times, the users prefer tile at the actual showers but can finalize during the design phaseAgree72 3/18/2025 Fire Station #1 Drawings4Floor Finishes Plans - First FloorSealed Concrete: Turnout 1, Turnout 2, Medical Storage, Janitor, EOC Storage, StorageNoneF&HSee comment below for item #74Agree73 3/18/2025 Fire Station #1 Drawings4Floor Finishes Plans - First FloorPolished Concrete, typ: Break, Men's Restroom, Lobby, Admin, Fire Marshall, Fire Chief, QuietNoneF&HSee comment below for item #74Agree74 3/18/2025 Fire Station #1 Drawings4 Floor Finishes Plans - First FloorMiscellaneousThere should be one flooring material throughout the new building. FD preference is polished concrete for easy maintenance. Second Floor - please use LVT in all spaces except at restroomsEliminate carpet in Lobby. Use carpet only in the training room, breakout room, and executive conference room.Use polished concrete on the ground floor. The ceramic tile area may be reduced to the shower area in each firefighter restroomNoneF&HThis can be reviewed, coordinated, and adjusted during the design phase. F&H does not anticipate this comment to have a cost impact.Currently as shown most of these items where per the RFP and direction during the VE discussions.Agree75 3/18/2025 Fire Station #1 Drawings4Floor Finishes Plans - Second Floor Sealed Concrete: LaundryF&HSee comment above for item #74Agree Atascadero Fire Station #1 - Scoping Documents CommentsComment NO.Date ReceivedBuilding Document Page Drawing Section/TopicCommentGraphicResponsibilityDBE ResponseCity ResponseDBE / Review Item Discussion76 3/18/2025 Fire Station #1 Drawings4 Floor Finishes Plans - Second FloorStairsRubber treads and risers at stairs, typ.F&HIs this a new requirement? Happy to coordinate with the City during design.The F&H design proposal introduced a second floor and stairs. The second floor and stairs was not a part of the RFP. The stair treads, risers and landing should be covered with a slip resistant, low maintenance, and durable material. 77 3/18/2025 Fire Station #1 Drawings4 Floor Finishes Plans - Second FloorOutdoor PatioProvide decking material above the roofing membrane to protect the roofingF&HA material will be needed but has not yet been determined. We can work with the City to determine during design.Agree78 3/18/2025 Fire Station #1 Drawings5 Wall Finishes - First Floor PlanTurnout 1 & Turnout 2FRP on walls in both these spacesF&HThis can be reviewed, coordinated, and adjusted during the design phase. F&H anticipates that this may have a minimal cost impact. F&H will work with the team mitigate or offset any cost impact during the design phase.FRP wall finish is noted in the RFP - program document. This should not be an extra cost.79 3/18/2025 Fire Station #1 Drawings5 Wall Finishes - First Floor PlanDecon & RRFRP on walls in both these spaces: Decon & adjacent RRF&HThis can be reviewed, coordinated, and adjusted during the design phase. F&H does not anticipate this comment to have a cost impact.Agree80 3/18/2025 Fire Station #1 Drawings5 Wall Finishes - First Floor PlanBreak RoomProvide backsplashF&HThis can be reviewed, coordinated, and adjusted during the design phase. F&H anticipates that this may have a minimal cost impact. F&H will work with the team mitigate or offset any cost impact during the design phase.Agree81 3/18/2025 Fire Station #1 Drawings5 Wall Finishes - First Floor PlanServer & IDFExposed rated plywood as wall finishF&HThis was not noted on the wall schedule as this is a requirement in the RFP as part of the Electrical Scope but is furnished and installed by F&HAgree82 3/18/2025 Fire Station #1 Drawings5 Wall Finishes - First Floor PlanRR adjacent to Quiet Room, Men's & Women's RestroomsConfirm height of the ceramic tile on wallsF&HAll wall tile will be to 8'Agree83 3/18/2025 Fire Station #1 Drawings5 Wall Finishes - Second Floor PlanRestroomsConfirm height of the ceramic tile on wallsF&HAll wall tile will be to 8'Agree84 3/18/2025 Fire Station #1 Drawings5 Wall Finishes - Second Floor PlanLegendPlease define height of the ceramic tile wallsF&HAll wall tile will be to 8' and where shownAgree85 3/18/2025 Fire Station #1 Drawings5 Wall Finishes - Second Floor PlanLegendPlease remove. Covered in FF&E as City provided, contractor installed.F&HThese changed somewhat during the VE process and we have tried to document per our discussions and directions. List provided, coordinate between City and F&HSee revised FF&E list. Atascadero Fire Station #1 - Scoping Documents CommentsComment NO.Date ReceivedBuilding Document Page Drawing Section/TopicCommentGraphicResponsibilityDBE ResponseCity ResponseDBE / Review Item Discussion86 3/18/2025 Fire Station #1 Drawings5 Wall Finishes - Second Floor PlanLegendLocations do not seem to be defined on the floor plans. Please provideF&HNot sure what is being requested but this can be coordinated during design.Agree. The comment was specific for corner guards. They are not grapically represented on the floor plans87 3/18/2025 Fire Station #1 Drawings6 Roof PlanPlease define roof covering material.F&HCurrently budget is a wood framed shade structure but will review other options during the Design Phase.Agree88 3/18/2025 Fire Station #1 Drawings6 Roof PlanRoof covering is required at trash enclosureF&HThis will be added during the design phase and is include and a required item Agree89 3/18/2025 Fire Station #1 Drawings6 Roof PlanRecommend removing small roof areas. These are difficult to maintain.LDAAgree. We will review and coordinate during design phase.Agree90 3/18/2025 Fire Station #1 Drawings6 Roof PlanWhat is the slope of these roof planes, typ?F&HTypically metal flashing caps but will be coordinated and finalized during design phaseAgree91 3/18/2025 Fire Station #1 Drawings7 Privacy Wall Types - First Floor Plan Level 3 on walls indicatedLDATo be determined in design and for best practices and requirementsAgree92 3/18/2025 Fire Station #1 Drawings7 Privacy Wall Types - First Floor Plan Level 3 at all restroom and IDF walls.LDAHard lid Ceiling and insulation provided in contract scope to address privacy levels. Will coordinate wall assemblies and STC ratings during design phaseAgree93 3/18/2025 Fire Station #1 Drawings7 Privacy Wall Types - Second Floor Plan Level 2 at all restroom wallsLDAHardlid Ceiling and insulation provided in contract scope to address privacy levels. Will coordinate wall assemblies and STC ratings during design phaseAgree94 3/18/2025 Fire Station #1 Drawings8 Exterior Elevations - South & West Please provide typical materials callouts on the exterior elevations to align with the narratives.LDAPlaster & thin brick per the scoping document writeup. Will review and edit during design phase.Agree95 3/18/2025 Fire Station #1 Electrical Drawings EF1-001 Electrical General NotesTypical Dwelling Unit Notes #20Update to CEC 160.5.ThomaThank you, we will correct. Difference between 150.0 and 160.5 is Architect's classification of R2 vs. R3. We will follow per Architect's classification.Agree96 3/18/2025 Fire Station #1 Electrical Drawings EF1-003 Electrical Single Line DiagramMissing Panel Schedules and Load Calculations NoneThomaDetails such as panel schedules and load calculations will be provided at DD level of design, not required for RFP submittal.Agree97 3/18/2025 Fire Station #1 Electrical Drawings EF1-003 Electrical Single Line DiagramReference Note 20NEC 690.13AC Disconnect must be installed on exteriorThomaCEC 690.13 notes that disconnect shall be provided at "readily accessible location". Interior to Electrical Room, as accessed through the use of keys is specifically allowed under the NEC definition of "readily accessible" (refer to CEC Section 100)Agree98 3/18/2025 Fire Station #1 Electrical Drawings EF1-003 Electrical Single Line DiagramReference Note 26Change CENC to CECThomaCEnC stands for CA Energy Code, CEC stands for California Electrical Code per our understanding. The reference here we believe is correct, but more importantly this requirement follows CA Energy Code.Agree99 3/18/2025 Fire Station #1 Electrical Drawings EF1S-101 Electrical Site PlanPLEASE REFER TO TOS COMMENTS PROVIDED ON 2. Scoping Document - FS1 Drawings - TOS REVIEW AND 1. Scoping Document - FS1 Narrative - TOS REVIEWFOR FIRE STATION 1NoneThomaAssumes any comments referenced here are answered elsewhere, no additional DBE response required?Agree100 3/18/2025 Fire Station #1 Electrical Drawings EF1S-101 Electrical Site PlanTELECOM CONDUITS MUST BE AT OPPOSITE ENDS OF VAULTThomaIf possible, this can be done, however per Thoma's proposal, Exhibit B, item #8 - at FS1 we assumed that conduits may enter/exit as necessary and do not necessarily need to enter vaults on opposing ends.Agree101 3/18/2025 Fire Station #1 Electrical Drawings EF1S-101 Electrical Site PlanTELECOM CONDUITS MUST BE AT OPPOSITE ENDS OF VAULTThomaSame DBE response as comment no. 100Agree Atascadero Fire Station #1 - Scoping Documents CommentsComment NO.Date ReceivedBuilding Document Page Drawing Section/TopicCommentGraphicResponsibilityDBE ResponseCity ResponseDBE / Review Item Discussion102 3/18/2025 Fire Station #1 Electrical Drawings EF1-101 Lighting Floor PlansPLEASE REFER TO TOS COMMENTS PROVIDED ON 2. Scoping Document - FS1 Drawings - TOS REVIEW AND 1. Scoping Document - FS1 Narrative - TOS REVIEW FOR FIRE STATION 1NoneThomaAssumes any comments referenced here are answered elsewhere, no additional DBE response required.Agree103 3/18/2025 Fire Station #1 Electrical Drawings EF1-102 Power Floor PlansFirst Floor PlanBreak RoomProvide sw receptacle for garbage disposal.ThomaThis will be provided at SD level of development. Agree - at no additional cost104 3/18/2025 Fire Station #1 Electrical Drawings EF1-102 Power Floor PlansFirst Floor PlanBreak RoomDedicated ckt required for small appliance areas on countertop.ThomaThis will be provided at DD level of development. Agree - at no additional cost105 3/18/2025 Fire Station #1 Electrical Drawings EF1-102 Power Floor PlansFirst Floor PlanBreak RoomRefrigerator receptacle should be on dedicated ckt.ThomaThis will be provided at DD level of development. Agree - at no additional cost106 3/18/2025 Fire Station #1 Electrical Drawings EF1-102 Power Floor PlansSecond Floor PlanPLEASE REFER TO TOS COMMENTS PROVIDED ON 2. Scoping Document - FS1 Drawings - TOS REVIEW AND 1. Scoping Document - FS1 Narrative - TOS REVIEW FOR FIRE STATION 1NoneThomaAssumes any comments referenced here are answered elsewhere, no additional DBE response required.Agree107 3/18/2025 Fire Station #1 Electrical Drawings EF1-102 Power Floor PlansSecond Floor PlanLaundry RoomDedicated ckt in laundry roomThomaThis will be provided at DD level of development. Agree - at no additional cost108 3/18/2025 Fire Station #1 Electrical Drawings EF1-102 Power Floor PlansReference Note 1Provide dimensions here or on plan viewThomaThis will be provided at CD level of development. Agree109 3/18/2025 Fire Station #1 Electrical Drawings EF1-102 Power Floor PlansReference Note 5Need to specify requirements: Red, non-locking, with indicator light, OR "COPS Compliant"ThomaReceptacles will be provided as red, non-locking, and with indicator light.Agree110 3/18/2025 Fire Station #1 Electrical Drawings EF1-103 Communications Floor PlansFirst FloorMechanical RoomCOORDINATE LOCATION WITH MECHANICALThomaThis will be provided at CD level of development. Agree111 3/18/2025 Fire Station #1 Electrical Drawings EF1-103 Communications Floor PlansFirst FloorElectrical RoomCOORDINATE LOCATION WITH MECHANICALThomaThis will be provided at CD level of development. Agree112 3/18/2025 Fire Station #1 Electrical Drawings EF1-103 Communications Floor PlansFirst FloorAdmin/Reception DeskADD DISTRESS ALERT AT RECEPTION DESKThomaAssumes that comment here is related to "DURESS" not "DISTRESS" and per VE with City of Atascadero, and as called out in Thoma's Exhibit B, a Duress System is excluded from scope per VE and Items #72, 73, and 74.Agree - City will provide if needed Atascadero Fire Station #1 - Scoping Documents CommentsComment NO.Date ReceivedBuilding Document Page Drawing Section/TopicCommentGraphicResponsibilityDBE ResponseCity ResponseDBE / Review Item Discussion113 3/18/2025 Fire Station #1 Electrical Drawings EF1-103 Communications Floor PlansPLEASE REFER TO TOS COMMENTS PROVIDED ON 2. Scoping Document - FS1 Drawings - TOS REVIEW AND 1. Scoping Document - FS1 Narrative - TOS REVIEWFOR FIRE STATION 1NoneThomaAssumes any comments referenced here are answered elsewhere, no additional DBE response required.Agree114 3/18/2025 Fire Station #1 Electrical Drawings EF1-103 Communications Floor PlansReference Note 3SEE ARCHITECTURAL DRAWINGS FOR MOUNTING HEIGHTThomaNoted, this will be provided at CD level of development, however final location will be coordinated at rough-in with final Architectural elevationsAgree115 3/18/2025 Fire Station #1 Electrical Drawings EF1-103 Communications Floor PlansAre all CAT6 lines to be terminated in I/T room? Provide contractor with direction on data lines. Can the contractor use bulk wire and terminate, or are factory-terminated ends required?Are data lines required for the lighting control system? If so, who will install? NoneThomaThis level of interconnection detail will be provided at DD level of development and following the development of the telecommunications riser. Lighting control system has not yet been specified. Cat6/Cat6a will be field terminated and tested. Lighting control cabling will be provided by EC (Thoma) as necessary per the Manufacturer.Agree116 3/18/2025 Fire Station #1 Electrical Drawings EF1-104 FSAS Floor PlansFirst Floor FS Alerting System PlanShouldn't relays be N.O. so they are in "interrupt" position unless coil is activated?ThomaWe will review for operational functionality, additional detail will be provided at CD level of development.Agree117 3/18/2025 Fire Station #1 Electrical Drawings EF1-104 FSAS Floor PlansFirst Floor FS Alerting System PlanADD TURNOUT TIMERSThomaRFP calls out for ToTs on the public-driveway side of the apparatus bay (for example, RFP says Lewis Ave. side at Driver's sightline, but apparatus bays face the Traffic Way side), therefore we have provided the ToT's on Traffic way side of apparatus bays (4 total) and believe that will be sufficient. Additional ToT's may be considered at DD level at added cost.In the RFP, there were four apparatus bays. The F&H proposed solution reduced the number of appratsu bays to three, which requires two of the fire apparatus to exit using the rear apron. The costs for the displays for the turnout timers will be covered under the FF&E. The infrastructure for the turnout timers should be covered by the F&H contract118 3/18/2025 Fire Station #1 Electrical Drawings EF1-104 FSAS Floor PlansFirst Floor FS Alerting System Plan?ThomaThis will be resolved in the Design Phase.Agree119 3/18/2025 Fire Station #1 Electrical Drawings EF1-104 FSAS Floor PlansFirst Floor FS Alerting System PlanADD TURNOUT TIMERS IN RESPONSE PATH FROM SECOND FLOOR ThomaRFP does not require ToT's in these locations, additional ToT's will be considered during Design Development at added cost.Agree - The City understands the RFP does not mention turnout timers outside of the apparatus bays but F&H introduced the second story which may make additional ToT's necessary. To be resolved during design.120 3/18/2025 Fire Station #1 Electrical Drawings EF1-104 FSAS Floor PlansPLEASE REFER TO TOS COMMENTS PROVIDED ON 2. Scoping Document - FS1 Drawings - TOS REVIEW AND 1. Scoping Document - FS1 Narrative - TOS REVIEW FOR FIRE STATION 1NoneThomaAssumes any comments referenced here are answered elsewhere, no additional DBE response required.Agree121 3/18/2025 Fire Station #1 Electrical Drawings EF1-105 Fire Alarm Floor PlansPLEASE REFER TO TOS COMMENTS PROVIDED ON 2. Scoping Document - FS1 Drawings - TOS REVIEW AND 1. Scoping Document - FS1 Narrative - TOS REVIEW FOR FIRE STATION 1NoneThomaAssumes any comments referenced here are answered elsewhere, no additional DBE response required.Agree122 3/18/2025 Fire Station #1 Electrical Drawings EF1-105 Fire Alarm Floor PlansReference Note 1Add end quote.ThomaWe will correct during the Design Phase.Agree123 3/18/2025 Fire Station #1 Electrical Drawings EF1-201 Enlarged Floor PlansAt Server RoomADD TELECOM ENLARGED PLANThomaThis will be provided at DD level of development. Agree124 3/18/2025 Fire Station #1 Electrical Drawings EF1-201 Enlarged Floor PlansAt KitchenDedicated ckt required for countertop small appliancesThomaThis will be provided at DD level of development. Agree Atascadero Fire Station #1 - Scoping Documents CommentsComment NO.Date ReceivedBuilding Document Page Drawing Section/TopicCommentGraphicResponsibilityDBE ResponseCity ResponseDBE / Review Item Discussion125 3/18/2025 Fire Station #1 Electrical Drawings EF1-201 Enlarged Floor PlansAt KitchenDedicated ckt required for refrigerators/freezers; If using AFCI, add it to the breaker so the receptacle can be reset without moving the appliance.ThomaThis will be provided at DD level of development. Aggree126 3/18/2025 Fire Station #1 Electrical Drawings EF1-201 Enlarged Floor PlansPLEASE REFER TO TOS COMMENTS PROVIDED ON 2. Scoping Document - FS1 Drawings - TOS REVIEW AND 1. Scoping Document - FS1 Narrative - TOS REVIEW FOR FIRE STATION 1NoneThomaAssumes any comments referenced here are answered elsewhere, no additional DBE response required.Agree127 3/20/2025 Fire Station #1 Electrical Drawings N/A N/APlease confirm with the FD fire alerting vendor the number of roof penetrations and antennae mounts needed for the fire radio systemNoneThomaRoof penetrations will be coordinated with the City during document development. Providing and installing radios, antenna, etc. are excluded from scope per Thoma proposal Exhibit B, Items #110 and #120, stating that Radio equipment shall be City provided and installed.F&H and LDA to review and confirm who will complete the roof penetration and mounting details. City to coordinate number of penetrations needed for City provided antenanna's, radio equipment, etc.128 3/20/2025 Fire Station #1 Electrical Drawings N/A N/APlease provide exterior speakers for the fire alerting system at the exercise patioNoneThomaThis will be review and add in the design phase. Agree - at no additional cost129 3/20/2025 Fire Station #1 Electrical Drawings N/A N/APlease provide a recessed floor box with data and power to the podium location in the Training Room/EOCNoneThomaThis will be review and add in the design phase. Agree - at no additional cost130 3/20/2025 Fire Station #1 Electrical Drawings N/A N/APlease provide data connection in the EOC Storage RoomNoneThomaThis will be review and we will add (1) 2-port data outlet in the design phase.Agree - at no additional cost Atascadero Fire Station #2 - Scoping Documents CommentsComment NO.Date ReceivedBuilding DocumentPage Drawing Section/TopicCommentGraphicResponsibilityDBE ResponseCity ResponseDBE / Review Item Discussion1 3/18/2025 Fire Station #2Narrative1 FF&E PackageVanir to review FF&E lists and share with F&H team to confirm contractor scope of work. NoneF&HNeed the updated FF&E lists, based on the VE discussed & direction, in order to comment.List provided, coordinate between City and F&HSee revised FF&E list.2 3/18/2025 Fire Station #2Narrative1Paragraph 2Please clarify 'single-level building'. The existing station is a split level. The new building portion of the fire station finish floor elevation shall match the existing apparatus bay finish floorNoneF&HWe can adjust to read "single-story building"Agree3 3/18/2025 Fire Station #2Narrative1Scope Items by SpecificationParagraph 1This is a very broad statement and should be updated to align with the scoping drawing package and FF&E lists. NoneF&HNot sure how to answer this as we have not seen an updated FF&E list based on the revised VE and requested changes.List provided, coordinate between City and F&HSee revised FF&E list.4 3/18/2025 Fire Station #2Narrative2Interior Architectural Woodworking & Casework - Bullet 7Add: Counter to decontamination area cabinet. This should be covered by FF&E?NoneF&HThis was edited based on changes requested during the negotiation phase. This item remained in budget comments & is part of F&H's scope.Agree5 3/18/2025 Fire Station #2Narrative2Interior Architectural Woodworking & Casework - Bullet 9Request that DB team be specific with NIC statements with naming each space where casework will not be included, so we can align with FF&E listsNoneF&HThis was edited based on changes requested during the negotiation phase. The LDA scoping drawings show the cabinets to remain that are part of F&H's scope. We should change the "Wall Finishes" drawings to read "Wall Finishes & Cabinets"Agree6 3/18/2025 Fire Station #2Narrative2RoofingBullet 1-3Confirm Class A roofing materials and length of warranties on composition shingles & PVC roofing.NoneF&HClass A PVC Roofing Membrane w/ 30 year warranty per original RFP will be installed at the new addition. Because of the current design of the existing app bay, the existing roofing will be removed and replace with a similar product to the existing. Agree7 3/18/2025 Fire Station #2Narrative2RoofingBullet 4Confirm minimum metal gauge on Roofing flashing & sheet metal.NoneF&HPer original RFP at the new additionA metal gauge is not noted in the RFP. F&H to please confirm minimum metal gauge for sheeting metal flashingThere will be multiple types and gauges of sheet metal for the project. It will range from galvanized to prefinished and based on the application. Likewise, the gauge will vary but in most cases will be 24 gauge for gutters & roof coping. We will meet all roofing manufacturer requirements.8 3/18/2025 Fire Station #2Narrative2Doors, Frames, Windows & HardwareBullet 3Existing Doors: What about the operators at each existing overhead door. Suggest adding "overhead" to clarify door type in this statementNoneF&HThe original three overhead/sectional doors & operators will remain as is and will be serviced only. The Southeast door & operator will be removed and replaced with a similar sectional door to match the existing other three doors as close as possible.Agree9 3/18/2025 Fire Station #2Narrative2Doors, Frames, Windows & HardwareBullet 5-7Please confirm material type for doors and windowsNoneF&HStandard doors, frames & hardware be coordinated with the City during the design phase. Doors & frames can be wood or metal, window frames either steel or aluminum depending on location. All ballistics ratings were removed during VEAgree10 3/18/2025 Fire Station #2Narrative3FinishesBullet 4Larger tiles and less grout lines are preferred for maintenanceNoneF&HThis can be reviewed, coordinated, and adjusted during the design phase. F&H does not anticipate this comment to have a cost impact.Agree11 3/18/2025 Fire Station #2Narrative3FinishesBullet 5-8Please refer to the drawings for comments on flooring and ceiling materialsNoneF&HComments on drawings addressed below. Agree12 3/18/2025 Fire Station #2Narrative3Miscellaneous ItemsBullet 1Suggest changing language (for ADA) to all code required signage for permittingNoneF&HWill adjust during design phaseAgree13 3/18/2025 Fire Station #2Narrative3Miscellaneous ItemsBullet 67 standard lockers: Are these the hygiene lockers? we had 8 shownNoneF&HOriginal requirement in the RFP to be met & need to confirm location and design with City input.Agree14 3/18/2025 Fire Station #2Narrative3Miscellaneous ItemsBullet 62 benches: Are these the shower benches or the ones in the restroom for changing?There are also an additional 1 shower bench and 1 changing bench in the Tier II decon roomNoneF&HBenches and locations can be reviewed during design. The shower benches are part of the toilet accessory description and scope.Agree15 3/18/2025 Fire Station #2Narrative4Site DevelopmentBullet 8Suggest changing language to all required permits shall be paid for by the City.NoneF&HWill edit & change wordingAgree Atascadero Fire Station #2 - Scoping Documents CommentsComment NO.Date ReceivedBuilding DocumentPage Drawing Section/TopicCommentGraphicResponsibilityDBE ResponseCity ResponseDBE / Review Item Discussion16 3/18/2025 Fire Station #2Narrative4General Conditions and Miscellaneous Project ItemsBullet 1 & 5Vanir and City to review.NoneF&HAcknowledged17 3/18/2025 Fire Station #2Narrative4General Conditions and Miscellaneous Project ItemsBullet 5Vanir and F&H to review.NoneF&HTeam to collaborate on revised language. Pending final languageThe revised wording provided today (4/9/2025) is acceptable to F&H. Thank you!18 3/18/2025 Fire Station #2Drawings1Site PlanShow Emergency Generator and Propane Tank along with enclosure or screen walls.F&H / ThomaThe emergency generator is going to be on the north side of the building (see electrical site plans). There is not a Propane Tank and please refer to Addendum #4 of the RFP under the section "Emergency Power System for Essential Services Facilities". This was also further addressed in Thomas Clarifications under item #49 and #50 as it relates to Fire Station #1 & #2. Agree19 3/18/2025 Fire Station #2Drawings1Site PlanPatioF&HPatio was removed based on the VE direction. Agree20 3/18/2025 Fire Station #2Drawings2Floor PlanPlease confirm location of exterior switchgear and location of mechanical units.F&H / ThomaThis will be designed based on required equipment during the design phase and coordinate with the City.Agree21 3/18/2025 Fire Station #2Drawings2Floor PlanWellness CenterCity wants double doors to the exterior for exercise equipment.F&HThis can be added during the design phase. F&H anticipates that changing to double door depending on selection may have a cost impact. F&H will work with the team to mitigate or offset any cost impact during the design phase.During VE the City agreed to eliminate the patios from the scope with the intention that they could add it later. It was not agreed to remove the doors to the exterior.The budget for the doors remained and this can be finalized in the design & will need to coordinate exterior access to the doors.22 3/18/2025 Fire Station #2Drawings2Floor PlanThis note conflicts with the written narrative and the FF&E lists. Need to work with the City and F&H to align scope of work with FF&HE list.F&HList provided, coordinate between City and F&HSee revised FF&E list.23 3/18/2025 Fire Station #2Drawings2Floor PlanDay RoomCity wants double doors to the exterior patio.F&HThis can be added during the design phase. F&H anticipates that changing to double door depending on selection may have a cost impact. F&H will work with the team to mitigate or offset any cost impact during the design phase.During VE the City agreed to eliminate the patios from the scope with the intention that they could add it later. It was not agreed to remove the doors to the exterior.The budget for the doors remained and this can be finalized in the design & will need to coordinate exterior access to the doors. Atascadero Fire Station #2 - Scoping Documents CommentsComment NO.Date ReceivedBuilding DocumentPage Drawing Section/TopicCommentGraphicResponsibilityDBE ResponseCity ResponseDBE / Review Item Discussion24 3/18/2025 Fire Station #2Drawings2Floor PlanPlease consider swapping the Laundry to be closer to DeconF&HThis can be reviewed, coordinated, and adjusted during the design phase. Swapping Laundry and IT room seems possible with little to no cost impact. F&H will work with the team to mitigate or offset any cost impact during the design phase.These locations were commented on since the confidential meetings and the request for the design team to address was made so there would be no cost impacts. This should be a no cost item to be reviewed during design.25 3/18/2025 Fire Station #2Drawings2Floor PlanCity FD requested swapping the medical storage to have direct access to App Bays.F&HThis can be reviewed, coordinated, and adjusted during the design phase. Swapping Med Storage and Janitor seems possible with little to no cost impact. F&H will work with the team to mitigate or offset any cost impact during the design phase.These locations were commented on since the confidential meetings and the request for the design team to address was made so there would be no cost impacts. This should be a no cost item to be reviewed during design.26 3/18/2025 Fire Station #2Drawings2Floor PlanMed Storage to open directly into App BaysF&HThis can be reviewed, coordinated, and adjusted during the design phase. Swapping Med Storage and Janitor seems possible with little to no cost impact. F&H will work with the team to mitigate or offset any cost impact during the design phase.These locations were commented on since the confidential meetings and the request for the design team to address was made so there would be no cost impacts. This should be a no cost item to be reviewed during design.27 3/18/2025 Fire Station #2Drawings3Floor Plan - CaseworkPer narrative, these should be covered by FF&E. Please confirm.LDA???This can be reviewed, coordinated, and adjusted during the design phase. Agree Atascadero Fire Station #2 - Scoping Documents CommentsComment NO.Date ReceivedBuilding DocumentPage Drawing Section/TopicCommentGraphicResponsibilityDBE ResponseCity ResponseDBE / Review Item Discussion28 3/18/2025 Fire Station #2Drawings4Floor Finishes PlanDecon RR & Tier II DeconEpoxy in both these spaces.F&HEpoxy can bee added to both spaces. This can be reviewed, coordinated, and adjusted during the design phase. F&H does not anticipate this comment to have a cost impact.Agree29 3/18/2025 Fire Station #2Drawings4Floor Finishes PlanITProvide static dissapative floor.F&HStatic Dissipative flooring is budgeted. This will be updated during the design phase.Agree30 3/18/2025 Fire Station #2Drawings4Floor Finishes PlanDayroom, Watch, Laundry, Lobby, RR, Hall, Bunks, RRThere should be one flooring material throughout the new building. FD preference is polished concrete for easy maintenance. If LVT is less expensive, then it should be used in lieu of polished concreteEliminate carpet.If polished concrete is used, the ceramic tile area may be reduced to the shower area in each firefighter restroomF&HFlooring can be reviewed, coordinated, and adjusted during the design phase.Currently as shown most of these items where per the RFP and direction during the VE discussions. Reviewing and eliminating any ceramic tile areas or epoxy areas shown would be a cost savings.Agree31 3/18/2025 Fire Station #2Drawings6Roof PlanPlease show roof drains and slopesNoneF&HThis has not been finalized and will be coordinated during the design phase.Agree32 3/18/2025 Fire Station #2Drawings7Floor Plan - Wall FinishesTurn OutFRP on walls in this spaceF&HWe will coordinate in design. We will add in the FRP but had not taken off as there is a conflict between the Space Characteristics check list (paint & wainscot are checked) the description below does indicate Full height FRP that we should have picked up.Agree - FRP is the intended wall finish per the RFP. 33 3/18/2025 Fire Station #2Drawings7Floor Plan - Wall FinishesDecon RR, Tier II DeconFRP in both these spaces on the wallsF&HWe will coordinate in design. We will change to show FRP in lieu of Ceramic tile. This is per the RFP documents. We will want to keep the ceramic time in the shower for best practices. Agree - the shower should remain ceramic tile. Note was just intended for the rest of the restroom and decon Atascadero Fire Station #2 - Scoping Documents CommentsComment NO.Date ReceivedBuilding DocumentPage Drawing Section/TopicCommentGraphicResponsibilityDBE ResponseCity ResponseDBE / Review Item Discussion34 3/18/2025 Fire Station #2Drawings7Floor Plan - Wall FinishesITExposed rated plywood as wall finishF&HThis is included and will need to be coordinated with the City and Thoma for all of the low voltage systemsAgree35 3/18/2025 Fire Station #2Drawings7Floor Plan - Wall FinishesLegendPlease define height of the ceramic tile wallsF&HAll wall tile will be to 8'Agree36 3/18/2025 Fire Station #2Drawings7Floor Plan - Wall FinishesLegendPlease remove. Covered in FF&E as City provided, contractor installed.F&HNote is shown from a previous version but was moved to an FF&E item during the VE phase.Agree37 3/18/2025 Fire Station #2Drawings7Floor Plan - Wall FinishesLegendWhy are corner guards not shown on FS 2 Legend and Floor Plan? NoneF&HThese will be added as needed during the design phase and not shown as we haven't gotten that far into design.Agree38 3/18/2025 Fire Station #2Drawings8RCP - PrivacyWellness Center, Day RoomLevel 3LDA???This can be reviewed, coordinated, and adjusted during the design phase. Agree39 3/18/2025 Fire Station #2Drawings8RCP - PrivacyLevel 3 at all restroom wallsLDA???This can be reviewed, coordinated, and adjusted during the design phase. Agree40 3/18/2025 Fire Station #2Drawings8RCP - PrivacyLegendConfirm if existing ceiling is to remain? F&HExisting ceiling in the app bay to remain. Agree41 3/18/2025 Fire Station #2Drawings8RCP - PrivacyProvide STC ratings for all wall typesNoneF&HThis will be established during the design phase. Agree42 3/18/2025 Fire Station #2Drawings9ElevationsSouthConfirm if there is an integral color coat for the plaster system for the base and field colors. Or if the color is applied by paint. F&HColor will be via integral color coating. Painting of new plaster can lead to condensation issues and is not recommended. The only exterior plaster to be painted will be at the existing app bay plastered walls.Agree Atascadero Fire Station #2 - Scoping Documents CommentsComment NO.Date ReceivedBuilding DocumentPage Drawing Section/TopicCommentGraphicResponsibilityDBE ResponseCity ResponseDBE / Review Item Discussion43 3/18/2025 Fire Station #2Drawings9ElevationsWest & EastWhich overhead door is the new one per narrativeF&HThe Southeast door as it is a much lighter system that the other three doors.Agree44 3/18/2025 Fire Station #2Drawings9ElevationsNorth, East, WestConfirm new paint over existing plasterF&HCorrect, see comment no. 42Agree45 3/18/2025 Fire Station #2Electrical Drawings EF2-001Electrical General NotesTypical Dwelling Unit NotesUpdate to CEC 160.5.ThomaWe will correct. Difference between 150.0 and 160.5 is Architect's classification of R2 vs. R3. This will follow per Architect's classification.Agree46 3/18/2025 Fire Station #2Electrical Drawings EF2-003 Electrical Single Line DiagramMissing Panel Schedules and Load CalculationsNoneThomaDetails such as panel schedules and load calculations will be provided at DD level of design.Agree47 3/18/2025 Fire Station #2Electrical Drawings EF2-003Electrical Single Line DiagramReference Note 7Not Optional.ThomaGenerator meets the definition of CEC 702 which defines systems for "Optional Standby" power sources. Providing and interconnection generator itself is not "Optional" - we will provide the generator, ATS and GCP per Single Line and site plan.Agree48 3/18/2025 Fire Station #2Electrical Drawings EF2-003Electrical Single Line DiagramReference Note 9SP: MetallicThomaWe will correct.Agree49 3/18/2025 Fire Station #2Electrical Drawings EF2S-101 Electrical Site PlanPLEASE REFER TO TOS COMMENTS PROVIDED ON 4. Scoping Document - FS 2 Drawings - TOS REVIEW AND 3. Scoping Document - FS2 Narrative - TOS REVIEWFOR FIRE STATION 2NoneThomaAssumes any comments referenced here are answered elsewhere, no additional DBE response required?Agree50 3/18/2025 Fire Station #2Electrical Drawings EF2S-101 Electrical Site PlanSHOW EXISTING TELECOM PATHWAYThomaRefer to reference note 3 which states which pathway is existing. Existing pathway from pull-box into building is to be demolished based on footprint of addition to FS2, demo work is not shown on this plan.Agree Atascadero Fire Station #2 - Scoping Documents CommentsComment NO.Date ReceivedBuilding DocumentPage Drawing Section/TopicCommentGraphicResponsibilityDBE ResponseCity ResponseDBE / Review Item Discussion51 3/18/2025 Fire Station #2Electrical Drawings EF2-101 Lighting Floor PlanPLEASE REFER TO TOS COMMENTS PROVIDED ON 4. Scoping Document - FS 2 Drawings - TOS REVIEW AND 3. Scoping Document - FS2 Narrative - TOS REVIEWFOR FIRE STATION 2NoneThomaAssumes any comments referenced here are answered elsewhere, no additional DBE response required.Agree52 3/18/2025 Fire Station #2Electrical Drawings EF2-101 Lighting Floor PlanHallways and corridors need emergency egress lightingAre the hatched luminaires nightlights or emergency lights?This reviewer hasn't seen arch sheets. Daylight zones should be shown on these sheets if not the A-sheets. Are daylight sensors installed in this system?NoneThomaHalf-hatched luminaires are equipped with 90-min backup batteries (as unit equipment) or powered by central inverter. Hallways and corridors are shown with half-hatched symbols indicating where emergency lighting is provided. Daylight zones will be provided at CD level of document development, as will occupancy/daylighting sensors locations.Agree53 3/18/2025 Fire Station #2Electrical Drawings EF2-102 Power Floor PlanPLEASE REFER TO TOS COMMENTS PROVIDED ON 4. Scoping Document - FS 2 Drawings - TOS REVIEW AND 3. Scoping Document - FS2 Narrative - TOS REVIEWFOR FIRE STATION 2NoneThomaAssumes any comments referenced here are answered elsewhere, no additional DBE response required.Agree54 3/18/2025 Fire Station #2Electrical Drawings EF2-103 Communications Floor PlanPLEASE REFER TO TOS COMMENTS PROVIDED ON 4. Scoping Document - FS 2 Drawings - TOS REVIEW AND 3. Scoping Document - FS2 Narrative - TOS REVIEWFOR FIRE STATION 2NoneThomaAssumes any comments referenced here are answered elsewhere, no additional DBE response required.Agree55 3/18/2025 Fire Station #2Electrical Drawings EF2-104 FSAS Floor PlanPLEASE REFER TO TOS COMMENTS PROVIDED ON 4. Scoping Document - FS 2 Drawings - TOS REVIEW AND 3. Scoping Document - FS2 Narrative - TOS REVIEWFOR FIRE STATION 2ThomaAssumes any comments referenced here are answered elsewhere, no additional DBE response required.Agree56 3/18/2025 Fire Station #2Electrical Drawings EF2-104 FSAS Floor PlanCorrect Sheet Title, reads "Fire Station 1"ThomaWe will correct in the design phaseAgree57 3/18/2025 Fire Station #2Electrical Drawings EF2-104FSAS Floor PlanEmergency Appliance Shut-Off DiagramShouldn't relays be N.O. so they are in "interrupt" position unless coil is activated?ThomaNoted, we will review for operational functionality, additional detail will be provided at CD level of development.Agree58 3/18/2025 Fire Station #2Electrical Drawings EF2-105 Fire Alarm Floor PlanCorrect Sheet Title, reads "Fire Station 1"ThomaWe will correct in the design phaseAgree59 3/18/2025 Fire Station #2Electrical Drawings EF2-105 Fire Alarm Floor PlanPLEASE REFER TO TOS COMMENTS PROVIDED ON 4. Scoping Document - FS 2 Drawings - TOS REVIEW AND 3. Scoping Document - FS2 Narrative - TOS REVIEWFOR FIRE STATION 2NoneThomaAssumes any comments referenced here are answered elsewhere, no additional DBE response required.Agree60 3/20/2025 Fire Station #2Electrical Drawings N/A N/AFD intends to accommodate 4 personnel at the Watch Office. Please review power and data plans.NoneThomaWe will review and add during the design phase Agree Atascadero Fire Station #2 - Scoping Documents CommentsComment NO.Date ReceivedBuilding DocumentPage Drawing Section/TopicCommentGraphicResponsibilityDBE ResponseCity ResponseDBE / Review Item Discussion61 3/20/2025 Fire Station #2Electrical Drawings N/A N/APlease confirm with the FD fire alerting vendor the number of roof penetrations and antennae mounts needed for the fire radio systemNoneThomaRoof penetrations will be coordinated with the City during document development. Providing and installing radios, antenna, etc. are excluded from scope per Thoma proposal Exhibit B, Items #110 and #120, stating that Radio equipment shall be City provided and installed.F&H and LDA to review and confirm who will complete the roof penetration and mounting details. City to coordinate number of penetrations needed for City provided antenanna's, radio equipment, etc.62 3/20/2025 Fire Station #2Electrical Drawings N/A N/APlease provide exterior speakers for the fire alerting system at the kitchen and exercise patio(s)NoneThomaThese will be considered during Design Development at added cost, since they were removed during VE exercises with City along with exterior patio.Agree Atascadero Police Department - Scoping Documents CommentsComment NO.Date ReceivedBuilding Document Page Drawing Section/TopicCommentGraphicResponsibilityDBE ResponseCity ResponseDBE / Review Item Discussion1 3/18/2025 Police Department Narrative1 Paragraph 1Add: & restroom with showers after both men's and women's locker room.NoneF&HWill change to read "men's locker room and restroom area" and "women's locker room and restroom area".Agree2 3/18/2025 Police Department Narrative1Scope Items by SpecificationParagraph 1This is a very broad statement and should be updated to align with the scoping drawing package and FF&E lists. NoneF&HNot sure how to answer this as we have not seen an updated FF&E list based on the revised VE and requested changes.Vanir and City team to finalize FF&E lists.See revised FF&E list.3 3/18/2025 Police Department Narrative2Interior Architectural Woodworking and CaseworkBullet 2Request that DB team be specific with NIC statements with naming each space where casework will not be included, so we can align with FF&E lists.NoneF&HThis was edited based on changes requested during the negotiation phase. The LDA scoping drawings show the cabinets to remain that are part of F&H's scope. We should change the "Wall Finishes" drawings to read "Wall Finishes & Cabinets"Agree4 3/18/2025 Police Department Narrative2RoofingBullet 1PVC Roofing: Confirm Class A roofing materials and length of warranties.NoneF&HClass A PVC Roofing Membrane w/ 30 year warranty per the original RFP at the Dispatch buildingAgree5 3/18/2025 Police Department Narrative2RoofingBullet 3Roofing flashing & Sheet Metal: Confirm minimum metal gauge.NoneF&HThe flashing at the Dispatch building will be Per the original RFPAgree6 3/18/2025 Police Department Narrative2Doors, Frames, Windows & HardwareBullet 3-4Please confirm material type for windowsNoneF&HStandard doors, frames & hardware be coordinated with the City during the design phase. Doors & frames can be wood or metal, window frames either steel or aluminum depending on location. All ballistics ratings were removed during VEAgree7 3/18/2025 Police Department Narrative2Finishes Bullet 4Larger tiles and less grout lines are preferred for maintenanceNoneF&HThis can be reviewed, coordinated, and adjusted during the design phase. F&H does not anticipate this comment to have a cost impact.Agree8 3/18/2025 Police Department Narrative2Finishes Bullet 5-6Please refer to the drawings for comments on flooring and ceiling materialsNoneF&HNot sure what is being askedAgree - Notes for simplication of flooring and ceiling types. Similar comment as FS 1 and FS 29 3/18/2025 Police Department Narrative2Miscellaneous ItemsBullet 1Suggest changing language (for ADA) to all code required signage for permitting.NoneF&HWill adjust during design phaseAgree10 3/18/2025 Police Department Narrative2Miscellaneous ItemsBullet 43 benches: Inconsistent with plan, which shows 5 locker benches. If referring to shower seat count please clarify. NoneF&HCorrections, there are only 2 benches shown. 1 in each of the locker rooms. The shower benches are referenced with the toilet accessories.Agree11 3/18/2025 Police Department Narrative3Site DevelopmentBullet 5Suggest changing language to all required permits shall be paid for by the City.NoneF&HWill correct as noted and add all permits to be paid by the CityAgree12 3/18/2025 Police Department Narrative3General Conditions and Miscellaneous Project ItemsBullet 1 & 5Vanir and City to review.NoneF&HAcknowledgedPending final languageThe revised wording provided today (4/9/2025) is acceptable to F&H. Thank you!13 3/18/2025 Police Department Narrative3General Conditions and Miscellaneous Project ItemsBullet 5Vanir and F&H to review.NoneF&HTeam to collaborate on revised language.Pending final languageThe revised wording provided today (4/9/2025) is acceptable to F&H. Thank you!14 3/18/2025 Police Department Drawings1 Site PlanConfirm accessible path of travel from parking to dispatch building, additional site work may be needed to accommodate a ramp.F&H / LDADue to the existing grades and in an effort to keep most of the patio, we may need to access from the front parking lot & through a secured man gate. This would keep the same area and use of the patio but a coordination issue we can discuss and incorporate during design.Agree Atascadero Police Department - Scoping Documents CommentsComment NO.Date ReceivedBuilding Document Page Drawing Section/TopicCommentGraphicResponsibilityDBE ResponseCity ResponseDBE / Review Item Discussion15 3/18/2025 Police Department Drawings1 Site PlanConfirm that new security fencing will connect with existing secured parking and pedestrian gates. F&HThe existing security man gate will be salvaged and reinstalled at the sidewalk area. There is no other fencing or gates included at the parking lot area as all site items not related to the New Dispatch building were removed during the VE efforts.Agree - but the secure area must remain secure at the completion of Dispatch.16 3/18/2025 Police Department Drawings1 Site PlanConfirm retaining wall is provided or needed?Vanir - also provide security fence in this area to maintain secure areaF&HA final architectural, civil and structural design will be coordinated during design to finalize the requirements for grades, retaining walls (if at building or site), fencing/gates and accessibility as needed for the Dispatch Building. This will be coordinated during the design phase.Agree17 3/18/2025 Police Department Drawings1 Site PlanOverex of foundation system may require the replacement of existing site improvementsF&HUnderstood but until we have a final soils report and structural design, we will not know what is required. This will be coordinated during the design phase.Agree18 3/18/2025 Police Department Drawings2Floor Plan & RCPDispatch Floor PlanThis note conflict with the written narrative and the FF&E lists. Clarify if dispatch consoles are to be included in scope or City Provided. F&HThe items shown in grey indicate furniture (FF&E items). This is typical for each of the facilities. In this case specifically, the Dispatch Consoles are to be and FF&E item by the City. Agree19 3/18/2025 Police Department Drawings2Floor Plan & RCPDispatch Floor PlanSite Plan shows this entire area covered. This will be needed so traffic between buildings can be coveredF&HThis can be changed or edited as we go through design and coordinate with the City. In design, we will also need to take into account the existing overhang at the main building that is currently not shown nor does it allow for the size of canopy shown in the red lined comment. Agree Atascadero Police Department - Scoping Documents CommentsComment NO.Date ReceivedBuilding Document Page Drawing Section/TopicCommentGraphicResponsibilityDBE ResponseCity ResponseDBE / Review Item Discussion20 3/18/2025 Police Department Drawings2Floor Plan & RCPDispatch RCPCity IT prefers acoustical ceilings in the IT spaceF&HThis can be changed or edited as we go through design and coordinate with the City.Agree21 3/18/2025 Police Department Drawings4 Wall TypesLevel 3F&HThis can be changed or edited as we go through design and coordinate with the City.Agree22 3/18/2025 Police Department Drawings4 Wall TypesPD would like to add or relocate window and awning to this location.F&HThe quantity / linear feet of awnings can be moved as requested by the City. As long as we stay within the footage and quantity currently shown, there will not be any costs changes. Agree23 3/18/2025 Police Department Drawings4 Wall FinishesFRP on walls in ITF&HWe would not recommend FRP on walls in the IT. Currently, F&H is including fire rated plywood on walls and over gypsum board as necessary for low voltage systemsAgree - fire rated plywood is the wall finish desired in the IT room24 3/18/2025 Police Department Drawings4Wall FinishesLegendPlease define height of the ceramic tile wallsF&HAll wall tile will be to 8'Agree25 3/18/2025 Police Department Drawings5Building ElevationsSouthPD would like to add or relocate window and awning to this location.F&HThe quantity & square footage of windows can be moved as requested by the City. As long as we stay within the footage and quantity currently shown, there will not be any costs changes. Agree26 3/18/2025 Police Department Drawings5Building ElevationsEastConfirm if there is an integral color coat for the plaster system for the base and field colors. Or if the color is applied by paint. F&HColor will be via integral color coating. Painting of plaster can lead to condensation issues and is not recommended.Agree Atascadero Police Department - Scoping Documents CommentsComment NO.Date ReceivedBuilding Document Page Drawing Section/TopicCommentGraphicResponsibilityDBE ResponseCity ResponseDBE / Review Item Discussion27 3/18/2025 Police Department Drawings6 PD Renovation Floor Finish PlanConfirm fixture count is enough to meet code and support 41 lockers.LDANumber of fixtures was determined by the City.Noted, please confirm that the fixture count meets the plumbing code and permitting requirements28 3/18/2025 Police Department Drawings6 PD Renovation Floor Finish PlanPD would like to add door and wall to create vestibule for visual and sound privacyF&HNeed to review during design to verify that this will meet ADA accessability standards and to also allow for access to existing roof hatch above.Agree - goal is to find a solution to limit line of sight into the locker room through the door29 3/18/2025 Police Department Drawings6 PD Renovation Floor Finish PlanPD would like to keep the existing door and wall to create vestibule for visual and sound privacy.F&HNeed to review during design to verify that this will meet ADA accessibility standardsAgree - goal is to find a solution to limit line of sight into the locker room through the door Atascadero Police Department - Scoping Documents CommentsComment NO.Date ReceivedBuilding Document Page Drawing Section/TopicCommentGraphicResponsibilityDBE ResponseCity ResponseDBE / Review Item Discussion30 3/18/2025 Police Department Drawings6 PD Renovation Floor Finish PlanConfirm fixture count is enough to meet code and support 14 lockers.LDANumber of fixtures was determined by the City.Noted, please confirm that the fixture count meets the plumbing code and permitting requirements31 3/18/2025 Police Department Drawings6PD Renovation Floor Finish PlanSamplesPD would like to remove all existing interior walls to create a larger room.F&HNeed to review during design and this would be a cost impact. The layout drawings provided to our team where followed and incorporated into the current and provided design.Agree32 3/18/2025 Police Department Drawings6PD Renovation Floor Finish PlanWomen's Locker RoomPD would like to add door and wall to create vestibule for visual and sound privacy.F&HThis can be reviewed, coordinated, and adjusted during the design phase. F&H anticipates that this may have a cost impact. F&H will work with the team mitigate or offset any cost impact during the design phase.Agree - goal is to find a solution to limit line of sight into the locker room through the door33 3/18/2025 Police Department Drawings7 PD Renovation RCPIs the ceiling in this area also to remain; patch, repair & paint?F&HWalls and ceilings will be patched/repaired and painted in both locker room areas.Agree34 3/18/2025 Police Department Drawings8PD Renovation Wall Finish PlanLegendPlease define height of the ceramic tile wallsF&HAll wall tile will be to 8'Agree35 3/18/2025 Police Department Electrical Drawings EP-003Electrical Single Line Diagram Missing Panel Schedules and Load CalculationsNoneThomaDetails such as panel schedules and load calculations will be provided at DD level of designAgree36 3/18/2025 Police Department Electrical Drawings EP-003Electrical Single Line DiagramReference Note 6Call-out at panel says "150A"ThomaWe will correct. Should be 150A/3P per SLDAgree Atascadero Police Department - Scoping Documents CommentsComment NO.Date ReceivedBuilding Document Page Drawing Section/TopicCommentGraphicResponsibilityDBE ResponseCity ResponseDBE / Review Item Discussion37 3/18/2025 Police Department Electrical Drawings EP-003Electrical Single Line Diagram Note 6 says "100A"Thomawe will correct. 150A/3P rating is accurate.Agree38 3/18/2025 Police Department Electrical Drawings EPS-101Electrical Site PlanPLEASE REFER TO TOS COMMENTS PROVIDED ON 5. Scoping Document - PD Narrative - TOS REVIEW AND 6. Scoping Document - PD Drawings - TOS REVIEWFOR THE NEW DISPATCH BUILDING AND THE EXISTING POLICE STATIONNoneThomaComments referenced here are answered elsewhere, no additional DBE response required.Agree39 3/18/2025 Police Department Electrical Drawings EP-101Lighting Floor PlanPLEASE REFER TO TOS COMMENTS PROVIDED ON 5. Scoping Document - PD Narrative - TOS REVIEW AND 6. Scoping Document - PD Drawings - TOS REVIEWFOR THE NEW DISPATCH BUILDING AND THE EXISTING POLICE STATIONNoneThomaComments referenced here are answered elsewhere, no additional DBE response required.Agree40 3/18/2025 Police Department Electrical Drawings EP-102Power Floor PlanPLEASE REFER TO TOS COMMENTS PROVIDED ON 5. Scoping Document - PD Narrative - TOS REVIEW AND 6. Scoping Document - PD Drawings - TOS REVIEWFOR THE NEW DISPATCH BUILDING AND THE EXISTING POLICE STATIONNoneThomaComments referenced here are answered elsewhere, no additional DBE response required.Agree41 3/18/2025 Police Department Electrical Drawings EP-102Power Floor PlanDispatch OfficePLEASE ADD POWER AND COMMUNICATION FOR A FULL CONSOLE IN OFFICEThomaWe will include & coordinate with City in the design phaseAgree - at no additional cost42 3/18/2025 Police Department Electrical Drawings EP-103Communications Floor PlanPLEASE REFER TO TOS COMMENTS PROVIDED ON 5. Scoping Document - PD Narrative - TOS REVIEW AND 6. Scoping Document - PD Drawings - TOS REVIEWFOR THE NEW DISPATCH BUILDING AND THE EXISTING POLICE STATIONNoneThomaComments referenced here are answered elsewhere, no additional DBE response required.Agree Atascadero Police Department - Scoping Documents CommentsComment NO.Date ReceivedBuilding Document Page Drawing Section/TopicCommentGraphicResponsibilityDBE ResponseCity ResponseDBE / Review Item Discussion43 3/18/2025 Police Department Electrical Drawings EP-103Communications Floor PlanDispatch Break RoomPLEASE ADD TV PER NOTE #2ThomaWe will include data and power for television location in future document development. Per FF&E list and Thoma Clarifications Exhibit B, Items #133, 134, and 135, Televisions will be provided and installed by CityAgree44 3/18/2025 Police Department Electrical Drawings EP-103Communications Floor PlanDispatch OfficeADD DATA TO THIS SIDE OF ROOMThomaPer item #41 in this worksheet, this room will already be getting (12) for the Dispatch console (as per Addendum #1), additional 4-port outlet is not included as a resultAgree45 3/18/2025 Police Department Electrical Drawings EP-104Fire Alarm Floor PlanPLEASE REFER TO TOS COMMENTS PROVIDED ON 5. Scoping Document - PD Narrative - TOS REVIEW AND 6. Scoping Document - PD Drawings - TOS REVIEWFOR THE NEW DISPATCH BUILDING AND THE EXISTING POLICE STATIONNoneThomaComments referenced here are answered elsewhere, no additional DBE response required.Agree46 3/20/2025 Police Department Electrical Drawings N/A N/APlease provide exterior lighting at the entry door at the Dispatch BuildingNoneThomaWe will include & coordinate with City in the design phaseAgree47 3/20/2025 Police Department Electrical Drawings N/A N/APlease confirm there is adequate lighting at the existing PD rear entrance. Want to have another footcandles for the path from the rear door to the entrance at the Dispatch building. NoneThomaAssumes exterior lighting is existing to remain as a function of Value Engineering already performed, refer to Thoma Proposal Exhibit B, Item #109 and per VE feedback from City team.Agree Atascadero Mechanical & Plumbing ProposalDate ReceivedBuilding Document Page Drawing Section/TopicCommentGraphicResponsibilityDBE ResponseCity ResponseDBE / Review Item Discussion3/18/2025 All Proposal 1Project TeamBullet 7Please confirm if HVAC and plumbing engineering design fees will be carried by Boneso or F&H.NoneBonesoConfirmed, the HVAC & Plumbing is part of a Design-Build subcontract with Boneso with them partnering with 3C's Engineering.Agree3/18/2025 All Proposal 2 HVAC Base Bid Includes Fire Station 1Confirm there is wall louver in the SCBANoneBonesoConfirmed, wall louver is includedAgree3/18/2025 All Proposal 2HVAC Base Bid Includes Fire Station 1Bullet 6-7Indicate equipment capacity (heat pump).NoneBonesoUnits will be sized accordingly as the design progresses. Probably finalized or available in the DD set of drawings. Agree3/18/2025 All Proposal 3HVAC Base Bid Includes PD with Dispatch OfficeDispatch Office Bullet 3Provide make/model of exhaust fan.NoneBonesoMake is currently Acme but will be verified and sized during the design phase and probably in the DD set of drawings.Agree3/18/2025 All Proposal 3HVAC Base Bid Includes PD with Dispatch OfficeDispatch Office Bullet 3Should say restroom, not locker room.NoneBonesoWe have updated the wording as requested.Provide document for confirmationSee attached3/18/2025 All Proposal 3HVAC Base Bid Includes PD with Dispatch OfficeDispatch Office Bullet 5Recommend providing a dedicated exhaust fan for the break room.NoneBonesoWe have updated the wording as requested.Provide document for confirmationSee attached3/18/2025 All Proposal 3HVAC Base Bid Includes PD with Dispatch OfficeLocker Rooms Bullet 3Provide necessary transfer ducts for all locker rooms.NoneBonesoThe renovation scope never included redoing the mechanical units or major ducting. This may be a cost item that we will need to discuss but shouldn’t be a major cost.Agree3/18/2025 All Proposal 3General Scope InclusionsBullet 1 (Drain waste & vent piping) Criteria says cast iron.NoneBonesoThis can be reviewed in design but PVC is a standard and included in the VE scoping. Let's review for best method during design and coordinate with the ownerAgree3/18/2025 All Proposal 4Plumbing Base Bid Includes Fire Station 1 Last Bullet PointConfirm who has the trench drains scope at each app bay.NoneF&H & BonesoTrench drains are furnished and install by the concrete crews (F&H or subcontractor) and will be hooked up & plumbed by BonesoAgree3/18/2025 All Proposal 6 ClarificationsHVAC and Plumbing exclusion sections were removed. Please add back into the scoping document for review.NoneBonesoSee updated and revised scoping document from Boneso / F&HProvide document for confirmationSee attached