HomeMy WebLinkAboutAUP_2025-01-10_AgendaPacketAdministrative Use Permit
HOW TO OBSERVE THE MEETING:
Interested individuals may attend the meeting in-person at Atascadero City Hall. To observe
remotely, the meeting may be livestreamed on Zoom. The video recording of the meeting will be
available through the City’s website and on the City’s YouTube Channel. To observe remotely
using the Zoom platform, please visit:
To join the virtual hearing:
https://us02web.zoom.us/j/84567568854
Webinar ID: 845 6756 8854
HOW TO SUBMIT PUBLIC COMMENT:
Public comment may be provided in-person.
Written public comments are accepted at aup-comments@atascadero.org by 5:00 pm the day
before the meeting. Such email comments must identify the Agenda Item Number in the
subject line of the email. The comments will be forwarded to the Administrative Hearing Officer
and made a part of the administrative record. If a comment is received after the deadline for
submission but before the close of the meeting, the comment will still be included as a part of the
administrative record of the meeting but will be forwarded to the Zoning Administrator the next
business day. Please note, email comments will not be read into the record.
AMERICAN DISABILITY ACT ACCOMMODATIONS:
Any member of the public who needs accommodations should contact the City Clerk’s Office at
cityclerk@atascadero.org or by calling (805) 470-3400 at least 48 hours prior to the meeting or
time when services are needed. The City will use their best efforts to provide reasonable
accommodations to afford as much accessibility as possible while also maintaining public safety
in accordance with the City procedure for resolving reasonable accommodation requests.
Administrative Use Permit agendas and staff reports may be viewed on the City's website:
www.atascadero.org. Final Action Reports will be available after the meeting, and upon request
from the Community Development Department.
Copies of the staff reports or other documentation relating to each item of business referred to on the Agenda are on
file in the Community Development Department and are available for public inspection on our website,
www.atascadero.org. All documents submitted by the public during AUP meetings that are either read into the record
or referred to in their statement will be noted in the audio recording and available for review by contacting the
Community Development Department. All documents will be available for public inspection during City Hall business
hours by appointment request.
Page 1 of 30
Administrative Use Permit Hearing
A G E N D A
The City of Atascadero’s Administrative Hearing Officer will hold a public hearing at
2:00 P.M. on Friday, January 10, 2025 at City Hall in Room 106 to consider the
following project:
1. 8306 EL CAMINO REAL (USE24-0109)
The application is to allow the installation of walls signs exceeding the standard
code size allowances on an existing restaurant building located at 8306 El
Camino Real (APN 056-041-047). The project is exempt from the California
Environmental Quality Act (CEQA) under Categorical Exemption §15303, Class
1 for existing facilities. Staff recommendation is to approve the project, subject
to conditions. (Erick Gomez, Associate Planner)
PLEASE NOTE: Any court challenge to the actions taken at the public hearing may be limited to
considering only those issues raised at the public hearing described in this notice or in written
correspondence to the City of Atascadero at, or prior to, the public hearing.
Any decision of the Hearing Officer is final unless appealed to the Planning Commission within 14 days of the action.
Any person aggrieved by the decision may file an appeal. Appeal forms are available in the Community Development
Department or on the City’s website (www.atascadero.org). The fee for filing an appeal is $1,668 (fee as of 7-29-24)
and must accompany the appeal documentation.
t:\~ administrative use permit\agendas\2025\jan 10\aup_2025-01-10_agenda.docx
Page 2 of 30
CITY OF ATASCADERO
ADMINISTRATIVE HEARING
STAFF REPORT
TO: Phil Dunsmore, Administrative Hearing Officer
FROM: Kelly Gleason, Planning Manager
PREPARED BY: Erick Gomez, Associate Planner
SUBJECT: USE24-0109, Dutch Bros Commercial Signs
8306 El Camino Real, Atascadero, CA 93422 (APN 056-041-047)
RECOMMENDATION:
The Administrative Hearing Officer approve Administrative Use Permit USE24-0109 allowing the
installation of signs exceeding the standard code size allowances, based on findings and subject
to conditions of approval.
DISCUSSION:
PROJECT SUMMARY
The existing multi-tenant commercial building is located on a 0.51-acre (ac) property within the
Food-4-Less commercial center in the Commercial Retail (CR) zoning district located at 8306 El
Camino Real (APN 056-041-047).
CVP-ATASCADERO DB LLC request a design exception to allow:
• Installation of 46.72 SF of wall sings, a 25% increase above the allowance of the
Atascadero Municipal Code (AMC).
• An aggregate sign area of 271 SF between Dutch Bros and their co-tenant, Jersey Mikes,
equivalent to approximately 9.5% above the allowance of the AMC.
The applicant will also be repairing and changing the faces of existing monument and pylon signs
and installing menu boards and directional signs in compliance with the Atascadero Municipal
Code.
ITEM #1
Department: Community
Development
Date: 01/10/2025
East Façade with (P) Dutch Bros Wall Signs and Jersey Mikes Wall Signs (Under Separate Permit)
Page 3 of 30
01/10/2025 | Item 1 | Staff Report
Page 2 of 8
ANALYSIS
The former Burger King building in the Food-4-Less shopping center has been split into two tenant
spaces. Dutch Bros Coffee will be occupying one of the tenant spaces with Jersey Mike’s
occupying the other. Dutch Bros tenant space has 37.5’ of building frontage facing El Camino Real
and 37.5’ of building frontage facing the existing Food 4 Less Commercial Center parking lot. The
Atascadero Municipal Code allows an aggregate of 150 SF of sign area on commercial buildings
with each tenant limited to 1 SF of wall sign area per linear foot of building frontage facing the
street or a parking lot. Given this standard, Dutch Bros signs would be limited to 37.5 SF on their
west and east building frontages. The applicant is requesting a sign design exception to allow
46.72 SF of wall sign area on both the west and east façade and an increased aggregate sign area
of 271 SF to accommodate signage for both tenants, inclusive of the proposed sign face changes
to the 38 SF monument sign and 68 SF freeway facing sign. The AMC allows design exceptions to
be made with the approval of an Administrative Use Permit subject to the findings included in
the following section.
FINDINGS:
AMC 9-1.112 requires the Administrative Hearing Officer to make the following 4 findings:
1. FINDING: The sign is consistent with the purposes set forth in Section 9-15.002(Intent)
FACT: The building was previously a single tenant building. The conversion of the build-
ing to a multi-tenant building necessitates additional sign area to accommodate both
tenants. The proposed signs are of a scale and design that is suitable for the proposed
structures. They will contribute well to the aesthetic of the building and will facilitate
identification of the occupying businesses without being overly complex or containing
nuisance elements.
2. FINDING: The opportunity to combine signs for more than one use on a single sign struc-
ture has been considered.
FACT: One existing monument sign will be shared between both tenants, as is depicted
in the project plans.
3. FINDING: For freeway-oriented signs, the sign area and height are the minimum needed
to achieve adequate visibility along the freeway due to highway ramp locations and
grade differences.
FACT: No changes in size or height are proposed for the existing highway-oriented sign.
Modifications are limited to replacement of the cabinet and sign face. The sign style and
size will be the same as what was installed for the previous Burger King restaurant.
4. FINDING: Conformance with all other applicable codes and ordinances of the City, in-
cluding, but not limited to, the Zoning Ordinance, General Plan and its several elements,
and the appearance review guideline
FACT: The proposed signs meet all other applicable requirements of the AMC.
Page 4 of 30
01/10/2025 | Item 1 | Staff Report
Page 3 of 8
ENVIRONMENTAL DETERMINATION:
The proposed project qualifies for a Class 1 categorical exemption from the provisions of the
California Environmental Quality Act (California Public Resources Code §§ 21000, et seq., “CEQA”)
and CEQA Guidelines (Title 14 California Code of Regulations §§ 15000, et seq.) pursuant to CEQA
Guidelines Section 15301, which exempts existing facilities. See Attachment 2.
CONCLUSION:
• The applicant is Proposing a design exception to allow for increased sign area facing El
Camino Real and the shopping center parking lot.
• The signs meet the intent of the code are well-designed for effective use on the
multitenant structure.
CONDITIONS:
1. This approval of Administrative Use Permit USE24-0109 as depicted and described on
the attached exhibits allows the installation of 46.72 SF of wall signs for Dutch Bros
Coffee shop on the east and west building facades of the existing restaurant building
located on a 0.51-ac property in the CR zoning district located at 8306 El Camino Real
(APN 056-041-047). The approval of these entitlements project runs with the land,
regardless of the owner.
2. The approval of these entitlements shall become final and effective for the purposes of
issuing building permits fourteen (14) days after the Administrative Officer hearing
unless an appeal is made in accordance with the Atascadero Municipal Code.
3. Approval of these entitlements shall be valid for twenty-four (24) months after its
effective date. At the end of the period, the approval shall expire and become null and
void unless the project has received a time extension consistent with the Atascadero
Municipal Code.
4. The Community Development Department shall have the authority to approve the
following minor changes to the project that (1) modify the site plan project by less than
10%, and/or (2) result in a superior site design or appearance.
5. The Applicant shall defend, indemnify, and hold harmless the City of Atascadero or its
agents, officers, and employees against any claim or action brought to challenge an
approval by the City, or any of its entities, concerning this administrative use permit.
ACTION:
☐ APPROVE ☐ APPROVE AS MODIFIED ☐ DENY
☐ CONTINUE TO ALLOW _________________________________________________________
SIGNED:
Phil Dunsmore, Administrative Hearing Officer Date
Page 5 of 30
01/10/2025 | Item 1 | Staff Report
Page 4 of 8
ATTACHMENTS:
1. Site and Zoning Map
2. Notice of Exemption
3. Project Plans
Page 6 of 30
10/29/2024 | Item 1 | Staff Report
Attachment 1: Site and Zoning Maps
Page 5 of 8
Page 7 of 30
01/10/2025 | Item 1 | Staff Report
Attachment 2: Notice of Exemption
Page 6 of 8
CITY OF ATASCADERO
NOTICE OF EXEMPTION
6500 Palma Avenue Atascadero, CA 93422 805.461.5000
Date Received Stamp
TO: Clerk-Recorder Office
County of San Luis Obispo
1055 Monterey Street Suite D120
San Luis Obispo, CA 93408
Office of Planning and Research
P.O. Box 3044, Room 113
Sacramento, CA 95812-3044
FROM: City of Atascadero Community Development Department 6500 Palma Avenue Atascadero, CA 93422 SUBJECT: Filing of Notice of Exemption in Compliance with Sections 15062 and 21152 of the Public Resources Code
Project Title: USE24-0109, Dutch Bros Wall Signs
Project Applicant: CVP-ATASCADERO DB LLC, 2188 SW Park Pl, Ste 100, Portland, OR 97205
planning@atascadero.org; (805) 470-5035
Project Location: 8306 El Camino Real, Atascadero, CA 93422 (APN 056-041-047)
Project Description: Administrative Use Permit for a design exception to allow:
1) The installation of 46.72 SF of wall signs for a Dutch Bros Coffee shop on the east and west
frontages of the existing building.
2) An aggregate wall sign area of 271 SF SF of sign area between Dutch Bros Coffee and their co-
tenant.
Name of Person or Agency Carrying Out Project: CVP-ATASCADERO DB LLC
Exempt Status:
Ministerial (Sec. 15268); General Rule Exemption (Sec. 15061. c);
Declared Emergency (Sec. 15269(a)); X Categorically Exempt (Sec. 15301 - 15333);
Emergency Project (Sec. 15269(b)(c)); Statutory Exemption (Sec. 15261 - 15285)
Reasons why the project is exempt: The project is exempt from environmental review pursuant to pursuant
to CEQA Guidelines Section 15301 (Existing Facilities). The proposed project will install a four wall signs.
No increase to the square footage or changes to the use of the building are proposed. The are no sensitive
Page 8 of 30
01/10/2025 | Item 1 | Staff Report
Attachment 2: Notice of Exemption
Page 7 of 8
environmental resources on the project or unusual environmental circumstances surrounding the project site.
There are no scenic or historical resources in the vicinity of the project site. The site is not a listed hazardous
waste site property. There are no cumulative impacts from associated successive projects.
Lead Agency Contact: Erick Gomez, Planner
(805) 470-3436
egomez@atascadero.org
Date Exemption Accepted: 01/10/2025
_________________________
01/10/2025
Page 9 of 30
10/29/2024 | Item 1 | Staff Report
Attachment 3: Project Plans
Page 8 of 8
Page 10 of 30
1
CONSTRUCTION MGR.
DIRECTOR
06-24-0008R3
SIGNS AND MENUS
ALL IDEAS, PLANS, AND ELECTRONIC
ART INDICATED ON THIS DRAWING ARE
COPYRIGHTED AND OWNED BY
FUSION SIGN AND DESIGN AND
SHALL NOT BE REPRODUCED, USED
BY OR DISCLOSED TO ANY PERSONS,
FIRM OR CORPORATION FOR ANY
PURPOSE WHATSOEVER WITHOUT
PERMISSION OF
FUSION SIGN AND DESIGN.
8306 El Camino Real
Atascadero, CA 93422
ADDRESS
DRAWING/REVISION NO.:
PAGE NO.:
OF
DUTCH BROS
CLIENT:
Approval Signature
06/18/2024
DATE:
Joanne P.
PROJECT MANAGER
Trong T.
DESIGNER:
11/14/2024
REVISION DATE:
Trong T.
REVISION BY:
12 226 Co as t Dr iv e
W hit ti er, CA 9 0601
( )Tel: 562 946-7545
( )Fax: 562 949-5707
St. Lic.: 894662
Los Angeles, CA
www.fusionsign.com
20
L E G E N D
S I G N C O D E
PROPOSED SQ. FT. ALLOWABLE SQ. FT.
S C H E D U L E
X DateTitle
A P P R O V A L
EXISTING SIGN
TO REMAINS1EXISTING SIGN
TO BE REMOVEDX1EXISTING SIGN
TO BE REPLACEDR1NEW
PROPOSEDN1
Dutch Bros Coffee
8306 El Camino Real
Atascadero, CA 93422
VICINITY MAP NOT TO SCALE
NORTHNORTH
AERIAL PHOTO / SITE PLAN NOT TO SCALE
NORTH
N1 - (1) SIGN TYPE DBCL10-REMOTE-RW: CHANNEL LETTERS WITH REMOTE RACEWAY
N2 - (1) SIGN TYPE DBCL10-REMOTE-RW: CHANNEL LETTERS WITH REMOTE RACEWAY
N3 - (1) SIGN TYPE DBW13: SELF CONTAINED LOGO
N4 - (1) SIGN TYPE DBW13: SELF CONTAINED LOGO
N5 - (2) SIGN TYPE DBMENU-WM-SF: WALL MOUNTED MENU BOARD
N6 - (1) ADDRESS NUMBERS
N7 - (2) SIGN TYPE DBMENU-PM-SF: FREE STANDING MENU BOARD
N8 - (1) SIGN TYPE DB-DIR-DT-DF: NON-ILLUMINATED D/F DIRECTIONAL
N9 - (1) SIGN TYPE DB-DIR-EO-DF: NON-ILLUMINATED D/F DIRECTIONAL
N10 - (2) EXISTING D/F MONUMENT SIGN REPLACEMENT FACES
N11 - (1) EXISTING D/F PYLON SIGN REPLACEMENT CABINET
CA4408
Page 11 of 30
2
CONSTRUCTION MGR.
DIRECTOR
06-24-0008R3
SIGNS AND MENUS
ALL IDEAS, PLANS, AND ELECTRONIC
ART INDICATED ON THIS DRAWING ARE
COPYRIGHTED AND OWNED BY
FUSION SIGN AND DESIGN AND
SHALL NOT BE REPRODUCED, USED
BY OR DISCLOSED TO ANY PERSONS,
FIRM OR CORPORATION FOR ANY
PURPOSE WHATSOEVER WITHOUT
PERMISSION OF
FUSION SIGN AND DESIGN.
8306 El Camino Real
Atascadero, CA 93422
ADDRESS
DRAWING/REVISION NO.:
PAGE NO.:
OF
DUTCH BROS
CLIENT:
Approval Signature
06/18/2024
DATE:
Joanne P.
PROJECT MANAGER
Trong T.
DESIGNER:
11/14/2024
REVISION DATE:
Trong T.
REVISION BY:
12 226 Co as t Dr iv e
W hit ti er, CA 9 0601
()Tel:562 946-7545
()Fax: 562 949-5707
St. Lic.: 894662
Los Angeles, CA
www.fusionsign.com
20EL CAM
INO
REAL
SITE PLAN
Scale: 1/32” = 1’-0”
SITE PLAN
N3 DBW13-@18.39SF
DBMENU-WM-SF N5
N1 DBCL10@28.33SF
N2 DBCL10@28.33SF
DBMENU-WM-SF N5
N4 DBW13-@18.39SF
N6 ADDRESS NUMBERS
DBMENU-PM-SF
N7N8 DB-DIR-DT-DF
N9 DB-DIR-EO-DF
EXISTING MONUMENT SIGN N10
Page 12 of 30
3
CONSTRUCTION MGR.
DIRECTOR
06-24-0008R3
SIGNS AND MENUS
ALL IDEAS, PLANS, AND ELECTRONIC
ART INDICATED ON THIS DRAWING ARE
COPYRIGHTED AND OWNED BY
FUSION SIGN AND DESIGN AND
SHALL NOT BE REPRODUCED, USED
BY OR DISCLOSED TO ANY PERSONS,
FIRM OR CORPORATION FOR ANY
PURPOSE WHATSOEVER WITHOUT
PERMISSION OF
FUSION SIGN AND DESIGN.
8306 El Camino Real
Atascadero, CA 93422
ADDRESS
DRAWING/REVISION NO.:
PAGE NO.:
OF
DUTCH BROS
CLIENT:
Approval Signature
06/18/2024
DATE:
Joanne P.
PROJECT MANAGER
Trong T.
DESIGNER:
11/14/2024
REVISION DATE:
Trong T.
REVISION BY:
12 226 Co as t Dr iv e
W hit ti er, CA 9 0601
()Tel:562 946-7545
()Fax: 562 949-5707
St. Lic.: 894662
Los Angeles, CA
www.fusionsign.com
20
Scale: 3/16” = 1’-0”
WEST ELEVATION TOTAL SQ. FT.: 46.72
DBCL10-@28.33 SF
DBW10-@18.39 SCALE: 1/4" = 1'-0"
4 WEST ELEVATION - WALK-UP WINDOW
T.O. PARAPET 3
+18'-3"
T.O. SLAB
B.O CANOPY &
AWNING+10'-6"
+22'-6"
T.O. PARAPET 1
+3'-2"
T.O. CAP
+0'-0"
T.O. SERVICE
COUNTER
+2'-10"
+19'-6"T.O. PARAPET 2
+12'-2"
+17'-0"
T.O. EXISTING
PARAPET
10’-0”2’-10”16”15-4”N1
16”
EQ 2’-9”EQ
72’-4”16”16-2 ½”N3
3’-8 ½” EQ EQ
4’-11 ½” DBMENU-WM- SF
N5
Page 13 of 30
4
CONSTRUCTION MGR.
DIRECTOR
06-24-0008R3
SIGNS AND MENUS
ALL IDEAS, PLANS, AND ELECTRONIC
ART INDICATED ON THIS DRAWING ARE
COPYRIGHTED AND OWNED BY
FUSION SIGN AND DESIGN AND
SHALL NOT BE REPRODUCED, USED
BY OR DISCLOSED TO ANY PERSONS,
FIRM OR CORPORATION FOR ANY
PURPOSE WHATSOEVER WITHOUT
PERMISSION OF
FUSION SIGN AND DESIGN.
8306 El Camino Real
Atascadero, CA 93422
ADDRESS
DRAWING/REVISION NO.:
PAGE NO.:
OF
DUTCH BROS
CLIENT:
Approval Signature
06/18/2024
DATE:
Joanne P.
PROJECT MANAGER
Trong T.
DESIGNER:
11/14/2024
REVISION DATE:
Trong T.
REVISION BY:
12 226 Co as t Dr iv e
W hit ti er, CA 9 0601
()Tel:562 946-7545
()Fax: 562 949-5707
St. Lic.: 894662
Los Angeles, CA
www.fusionsign.com
20
NORTH ELEVATION
Scale: 3/16”=1’-0”
+9'-0"
+12'-8"
+18'-3"
+22'-6"
+19'-6"
+0'-0"
Page 14 of 30
5
CONSTRUCTION MGR.
DIRECTOR
06-24-0008R3
SIGNS AND MENUS
ALL IDEAS, PLANS, AND ELECTRONIC
ART INDICATED ON THIS DRAWING ARE
COPYRIGHTED AND OWNED BY
FUSION SIGN AND DESIGN AND
SHALL NOT BE REPRODUCED, USED
BY OR DISCLOSED TO ANY PERSONS,
FIRM OR CORPORATION FOR ANY
PURPOSE WHATSOEVER WITHOUT
PERMISSION OF
FUSION SIGN AND DESIGN.
8306 El Camino Real
Atascadero, CA 93422
ADDRESS
DRAWING/REVISION NO.:
PAGE NO.:
OF
DUTCH BROS
CLIENT:
Approval Signature
06/18/2024
DATE:
Joanne P.
PROJECT MANAGER
Trong T.
DESIGNER:
11/14/2024
REVISION DATE:
Trong T.
REVISION BY:
12 226 Co as t Dr iv e
W hit ti er, CA 9 0601
()Tel:562 946-7545
()Fax: 562 949-5707
St. Lic.: 894662
Los Angeles, CA
www.fusionsign.com
20
16”
Scale: 3/16”=1’-0”
SOUTH ELEVATION
+9'-0"
+12'-8"
+18'-3"
+22'-6"
+19'-6"
+0'-0" 16” 3’-10” 15’-4” 10’-0” 34’-2”
45’-6”
Page 15 of 30
6
CONSTRUCTION MGR.
DIRECTOR
06-24-0008R3
SIGNS AND MENUS
ALL IDEAS, PLANS, AND ELECTRONIC
ART INDICATED ON THIS DRAWING ARE
COPYRIGHTED AND OWNED BY
FUSION SIGN AND DESIGN AND
SHALL NOT BE REPRODUCED, USED
BY OR DISCLOSED TO ANY PERSONS,
FIRM OR CORPORATION FOR ANY
PURPOSE WHATSOEVER WITHOUT
PERMISSION OF
FUSION SIGN AND DESIGN.
8306 El Camino Real
Atascadero, CA 93422
ADDRESS
DRAWING/REVISION NO.:
PAGE NO.:
OF
DUTCH BROS
CLIENT:
Approval Signature
06/18/2024
DATE:
Joanne P.
PROJECT MANAGER
Trong T.
DESIGNER:
11/14/2024
REVISION DATE:
Trong T.
REVISION BY:
12 226 Co as t Dr iv e
W hit ti er, CA 9 0601
()Tel:562 946-7545
()Fax: 562 949-5707
St. Lic.: 894662
Los Angeles, CA
www.fusionsign.com
20
16”
Scale: 3/16”=1’-0”
EAST ELEVATION
+0'-0"
+9'-0"
+12'-8"
+18'-3"
+22'-6"
+19'-6"
DUTCH BROS JERSEY MIKE’S
DBCL10-@28.33SF
N2
26’-9”
3’-8 ½” EQ EQ
10’-6”
37’-3”
10’-0” 16” 2’-10” 15’-4” DBMENU-WM-SF
N5
TOTAL SQ. FT.: 46.72
DBW13-@18.39SF
ADDRESS NUMBERS 12’-2” 6”
8306
N6
N4 16’-2 ½” 16” 4’-11 ½”Page 16 of 30
7
CONSTRUCTION MGR.
DIRECTOR
06-24-0008R3
SIGNS AND MENUS
ALL IDEAS, PLANS, AND ELECTRONIC
ART INDICATED ON THIS DRAWING ARE
COPYRIGHTED AND OWNED BY
FUSION SIGN AND DESIGN AND
SHALL NOT BE REPRODUCED, USED
BY OR DISCLOSED TO ANY PERSONS,
FIRM OR CORPORATION FOR ANY
PURPOSE WHATSOEVER WITHOUT
PERMISSION OF
FUSION SIGN AND DESIGN.
8306 El Camino Real
Atascadero, CA 93422
ADDRESS
DRAWING/REVISION NO.:
PAGE NO.:
OF
DUTCH BROS
CLIENT:
Approval Signature
06/18/2024
DATE:
Joanne P.
PROJECT MANAGER
Trong T.
DESIGNER:
11/14/2024
REVISION DATE:
Trong T.
REVISION BY:
12 226 Co as t Dr iv e
W hit ti er, CA 9 0601
()Tel:562 946-7545
()Fax: 562 949-5707
St. Lic.: 894662
Los Angeles, CA
www.fusionsign.com
20
INTERNALLY ILLUMINATED FACE-LIT FLUSH MOUNTED CHANNEL LETTERS 5" DEEP CHANNEL LETTERS.
230-127 INTENSE BLUE PSV, 230-015 YELLOW PSV, 230-33 RED PSV.
LED ILLUMINATION.
FLUSH MOUNTED CHANNEL LETTERS WITH REMOTE MOUNTED RACEWAY.
RACEWAY SHALL HAVE A CAULKING APPLIED ALONG THE TOP AND SIDES.
ALL HOLE PENETRATIONS WILL BE SEALED WITH CAULKING.
5” RETURNS & 1”TRIM CAP PAINTED TO MATCH PANTONE 7691 C “INTENSE BLUE”. WHITE ACRYLIC FACES.8”1”9”10'-0"
FABRICATED REMOTE RACEWAY
.040 PRE-COAT WHITE ALUMINUM 1”REMOVABLE DOORS FOR SERVICE BOTTOM RACEWAY TAB
1.) INSTALLATION OF THIS SIGN SHALL CONFORM TO THE REQUIREMENTS OF ARTICLE 600 OF NEC, UL48 AND/OR
OTHER APPLICABLE LOCAL CODES.
2.) BRANCH CIRCUIT:
A.) ALL BRANCH CIRCUITS FOR SIGNS MUST BE TOTALLY DEDICATED TO SIGNS (INCLUDING DEDICATED
GROUND AND DEDICATED NEUTRAL PER CIRCUIT).
B.) SIGN CIRCUITS MUST NOT BE SHARED WITH OTHER LOADS SUCH AS LIGHTING, AIR CONDITIONING AND
OTHER EQUIPMENT.
C.) PROPERTY SIZED GROUND WIRE THAT CAN BE TRACKED TO THE BREAKER PANEL MUST BE PROVIDED.
3.) U.L. AND DATA LABELS REQUIRED
4. ) SIGN SATISFIES ALL REQUIREMENTS OF TITLE 24.
5. ) OUTDOOR SIGNAGE TO EMPLOY EITHER PHOTOCELL OR OUTDOOR ASTRONOMICAL TIMER
GENERAL NOTES:
QTY. 2
SCOPE OF WORK: MANUFACTURE & INSTALL (2) SETS OF ILLUMINATED CHANNEL LETTERS WITH REMOTE RACEWAYS
14 3/4"2'-10"1'-6 3/4"12"10'-0"
SIDE VIEW
5"
Scale: 3/4” = 1’-0”
SIGN TYPE DBCL10: SELF CONTAINED LOGO
TOTAL SQ. FT.: 28.33 1"
WHITE
230-127 INTENSE BLUE PSV
230-33 RED PSV
230-015 YELLOW PSV
PMS 300C
PMS 7691C
PMS 1797C
PMS 116C
COLOR SPECIFICATIONS:
Scale: 6” = 1’-0”
⅜”2 ¾”.063” ALUM
CLIP
COFFEE
UNDERSCORE
COFFEE UNDERSCORE FACE
RETENTION CLIP
N2N1
67 LEDS @ 48.24W
LED LAYOUT NTS
48 LEDS @ 34.56W
ON
5”
DISCONNECT SWITCH
ELECTRICAL CONNECTION
TO PRIMARY
LOW VOLTAGEPOWER SUPPLY
INSIDE INCLOSURE
LOW VOLTAGE WIRE 36” PIGTAIL FOR EACH LETTER
.040” ALUM. RETURN
⅛” ACM BACKS (LETTERS)
WHITE L.E.D.
WHITE L.E.D.
1” JEWELITE TRIM CAP
⅛” WHITE ACRYLIC W/1ST SURFACE
VINYL OUTLINE 230-127 INTENSE BLUE
⅛” WHITE ACRYLIC W/1ST SURFACE
VINYL 230-127 INTENSE BLUE, 230-33
RED AND 230-15 YELLOW
1” JEWELITE TRIM CAP
LETTERS:
COFFEE UNDERSCORE:
#10 TEK SCREWS
FABRICATED RACEWAY
EXISTING WALL
¼” LAG SCREW MIN. EMBED.=5/8”
MIN. THREADED PEN.=5/8” INTO
PLYWOOD, MIN. (3) PER LETTER
EVENLY SPACED
¼” LAG SCREW MIN. EMBED.=5/8”
MIN. THREADED PEN.=5/8” INTO
PLYWOOD, SPACED @ 3’-0” O.C.
FOR STRIP MIN. (4) TOTAL FOR
“COFFEE” LOGO EVENLY SPACED
W/ SPACERS AS REQUIRED
THIS SIGN IS INTENDED TO BE
INSTALLED IN ACCORDANCE
WITH THE REQUIREMENTS OF
ARTICLE 600 OF THE NATIONAL
ELECTRICAL CODE AND/OR OTHER
APPLICABLE LOCAL CODES.
THIS INCLUDES PROPER GROUNDING
AND BONDING OF THE SIGN.
LISTED
ELECTRIC SIGN SECTION ELECTRICAL SPECIFICATIONS
TOTAL CIRCUIT LOAD:
1.2 AMPS @ 120 VAC
LETTERS & COFFEE UNDERSCORE:
(1) CUSTOMER PROVIDED 120V/20A/60HZ
DEDICATED CIRCUIT REQUIRED
(73) WHITE LED MODULES @ 0.72W EA= 52.56W TOTAL
(1) 12V 60W POWER SUPPLIES @ 1.2 AMPS EA.
INSTALLATION SPECIFICATIONS:
All hardware should be corrosion resistant.
Recommended mounting hardware:
Option 1: -Stucco or dryvit over plywood substrate:
#10” X 3” long hex head lag bolts & washers.
Option 2: -Stucco or dryvit over hollow substrate:
1/4” X 4” toggle bolts & washers.
Option 3: -Concrete or masonry: screws size #10
Tapcon anchors
Option 4: -Sheet metal: 1/4” X 4” threaded rods &
washers w/ 2x4 wood blocking or 1 1/2” aluminum
angle or 1/4” thick X 2” flat bars.Page 17 of 30
8
CONSTRUCTION MGR.
DIRECTOR
06-24-0008R3
SIGNS AND MENUS
ALL IDEAS, PLANS, AND ELECTRONIC
ART INDICATED ON THIS DRAWING ARE
COPYRIGHTED AND OWNED BY
FUSION SIGN AND DESIGN AND
SHALL NOT BE REPRODUCED, USED
BY OR DISCLOSED TO ANY PERSONS,
FIRM OR CORPORATION FOR ANY
PURPOSE WHATSOEVER WITHOUT
PERMISSION OF
FUSION SIGN AND DESIGN.
8306 El Camino Real
Atascadero, CA 93422
ADDRESS
DRAWING/REVISION NO.:
PAGE NO.:
OF
DUTCH BROS
CLIENT:
Approval Signature
06/18/2024
DATE:
Joanne P.
PROJECT MANAGER
Trong T.
DESIGNER:
11/14/2024
REVISION DATE:
Trong T.
REVISION BY:
12 226 Co as t Dr iv e
W hit ti er, CA 9 0601
()Tel:562 946-7545
()Fax: 562 949-5707
St. Lic.: 894662
Los Angeles, CA
www.fusionsign.com
20
DBW13
SCALE: 3/4"=1'-0"
3'-8 1/2"4'-11 1/2"SCOPE OF WORK: MANUFACTURE & INSTALL (2) ILLUMINATED WINDMILL LOGOS
INTERNALLY ILLUMINATED FACE-LIT FLUSH MOUNTED CHANNEL WRAP LOGO 5" DEEP CHANNEL WRAP.
5” RETURNS & 1” TRIM CAP PAINTED TO MATCH PANTONE 7691 C “INTENSE BLUE”. WHITE ACRYLIC FACE.
230-127 INTENSE BLUE PSV OUTLINE.
LED ILLUMINATION.
FLUSH MOUNTED SELF CONTAINED INSTALLATION.
ATTACHMENT DETAIL
SELF CONTAINED CHANNEL LOGO
WOOD STUD WALL
1/4"X3" LAG SCREWS INTO WOOD
(X2) TOP
(X2) BOTTOM
WET LOCATION LED
POWER SUPPLY
J-BOX
120V POWER
WOOD SHEATHING
5"
Side View
ATTACHMENT DETAIL
SELF CONTAINED CHANNEL LOGO
Scale: 3/4” = 1’-0”
SIGN TYPE DBW13: SELF CONTAINED LOGO
TOTAL SQ. FT.: 18.39
1"
WHITE
230-127 INTENSE BLUE PSV
COLOR CODE
Scale: 6” = 1’-0”
FACE RETENTION CLIP
½”2 ¾”.063” ALUM
CLIP
FACE
N3 N4
LED LAYOUT NTSLPV-35-12QTY. 2
THIS SIGN IS INTENDED TO BE
INSTALLED IN ACCORDANCE
WITH THE REQUIREMENTS OF
ARTICLE 600 OF THE NATIONAL
ELECTRICAL CODE AND/OR OTHER
APPLICABLE LOCAL CODES.
THIS INCLUDES PROPER GROUNDING
AND BONDING OF THE SIGN.
LISTED
ELECTRIC SIGN SECTION
ELECTRICAL SPECIFICATIONS
(27) WHITE LED MODULES @ 0.72W EA= 19.44W TOTAL
(1) 12V 35W POWER SUPPLIES @ 1.1 AMPS EA.
TOTAL CIRCUIT LOAD:
1.1 AMPS @ 120 VAC
LOGO:
(1) CUSTOMER PROVIDED 120V/20A/60HZ
DEDICATED CIRCUIT REQUIRED
NOTES:
ELECTRICAL COMPONENTS TO BE UL LISTED
AND INSTALLED IN ACCORDANCE WITH THE
NATIONAL ELECTRIC CODE (NEC)
ALL WIRING SHALL BE 12 GA
(1) 20 AMP-120V CIRCUIT TO BE BROUGHT
TO JOB SITE BY LICENCED ELECTRICIAN.
ALL SIGNAGE WILL BE UL2161 COMPLIANT
AND CARRY UL LABELS.
1.) INSTALLATION OF THIS SIGN SHALL CONFORM TO THE REQUIREMENTS OF ARTICLE 600 OF NEC, UL48 AND/OR
OTHER APPLICABLE LOCAL CODES.
2.) BRANCH CIRCUIT:
A.) ALL BRANCH CIRCUITS FOR SIGNS MUST BE TOTALLY DEDICATED TO SIGNS (INCLUDING DEDICATED
GROUND AND DEDICATED NEUTRAL PER CIRCUIT).
B.) SIGN CIRCUITS MUST NOT BE SHARED WITH OTHER LOADS SUCH AS LIGHTING, AIR CONDITIONING AND
OTHER EQUIPMENT.
C.) PROPERTY SIZED GROUND WIRE THAT CAN BE TRACKED TO THE BREAKER PANEL MUST BE PROVIDED.
3.) U.L. AND DATA LABELS REQUIRED
4. ) SIGN SATISFIES ALL REQUIREMENTS OF TITLE 24.
5. ) OUTDOOR SIGNAGE TO EMPLOY EITHER PHOTOCELL OR OUTDOOR ASTRONOMICAL TIMER
GENERAL NOTES:INSTALLATION SPECIFICATIONS:
All hardware should be corrosion resistant.
Recommended mounting hardware:
Option 1: -Stucco or dryvit over plywood substrate:
#10” X 3” long hex head lag bolts & washers.
Option 2: -Stucco or dryvit over hollow substrate:
1/4” X 4” toggle bolts & washers.
Option 3: -Concrete or masonry: screws size #10
Tapcon anchors
Option 4: -Sheet metal: 1/4” X 4” threaded rods &
washers w/ 2x4 wood blocking or 1 1/2” aluminum
angle or 1/4” thick X 2” flat bars.
Page 18 of 30
9
CONSTRUCTION MGR.
DIRECTOR
06-24-0008R3
SIGNS AND MENUS
ALL IDEAS, PLANS, AND ELECTRONIC
ART INDICATED ON THIS DRAWING ARE
COPYRIGHTED AND OWNED BY
FUSION SIGN AND DESIGN AND
SHALL NOT BE REPRODUCED, USED
BY OR DISCLOSED TO ANY PERSONS,
FIRM OR CORPORATION FOR ANY
PURPOSE WHATSOEVER WITHOUT
PERMISSION OF
FUSION SIGN AND DESIGN.
8306 El Camino Real
Atascadero, CA 93422
ADDRESS
DRAWING/REVISION NO.:
PAGE NO.:
OF
DUTCH BROS
CLIENT:
Approval Signature
06/18/2024
DATE:
Joanne P.
PROJECT MANAGER
Trong T.
DESIGNER:
11/14/2024
REVISION DATE:
Trong T.
REVISION BY:
12 226 Co as t Dr iv e
W hit ti er, CA 9 0601
()Tel:562 946-7545
()Fax: 562 949-5707
St. Lic.: 894662
Los Angeles, CA
www.fusionsign.com
20
SCOPE OF WORK: MANUFACTURE & INSTALL (2) S/F WALL MOUNTED MENU SIGNS
Scale: 1” = 1’-0”
SIGN TYPE DBMENU-WM-SF: WALL MOUNTED MENU BOARDS
TOTAL SQ. FT.: 10.70
N5 QTY. 2
Page 19 of 30
10
CONSTRUCTION MGR.
DIRECTOR
06-24-0008R3
SIGNS AND MENUS
ALL IDEAS, PLANS, AND ELECTRONIC
ART INDICATED ON THIS DRAWING ARE
COPYRIGHTED AND OWNED BY
FUSION SIGN AND DESIGN AND
SHALL NOT BE REPRODUCED, USED
BY OR DISCLOSED TO ANY PERSONS,
FIRM OR CORPORATION FOR ANY
PURPOSE WHATSOEVER WITHOUT
PERMISSION OF
FUSION SIGN AND DESIGN.
8306 El Camino Real
Atascadero, CA 93422
ADDRESS
DRAWING/REVISION NO.:
PAGE NO.:
OF
DUTCH BROS
CLIENT:
Approval Signature
06/18/2024
DATE:
Joanne P.
PROJECT MANAGER
Trong T.
DESIGNER:
11/14/2024
REVISION DATE:
Trong T.
REVISION BY:
12 226 Co as t Dr iv e
W hit ti er, CA 9 0601
()Tel:562 946-7545
()Fax: 562 949-5707
St. Lic.: 894662
Los Angeles, CA
www.fusionsign.com
20
4”11/16”2 3/16”11/16”2 3/16”SECTION DETAIL
Scale: 6” = 1’-0”
ON
OFF
ELECTRICAL WHIP
WHITE LED .118” WHITE
LEXAN DIFFUSER
.118” CLEAR LEXAN
.090” ALUM.
RETAINER CLIP
FABRICATED .090”
ALUM. CABINET
FABRICATED .090”
ALUM. RETAINER
FABRICATED .063”
ALUM. HOUSING
DISCONNECT SWITCH
LED POWER SUPPLY 4”.118” WHITE
DIFFUSER
PIANO HINGE
SECTION DETAIL
Scale: 6” = 1’-0”
11/16”2 3/16”
FABRICATED .090”
ALUM. CABINET
.118” CLEAR LEXAN
FABRICATED .063”
ALUM. HOUSING
DISCONNECT SWITCH
.090” ALUM.
RETAINER CLIP
B
-
A
-
FABRICATED .090”
ALUM. RETAINER QUARTER TURN CAPTIVE
PANEL SCREW (2)
ALUMINUM SNAP FRAME
MENU INSERT
20 3/16” X 11/3/16”
MENU INSERT
41 ¼” X 23 ½”
11/16”2 3/16”
1”1”FABRICATED .063”
ALUM. BACK
ALUMINUM SNAP FRAME
MENU INSERT
41 ¼” X 23 ½”
FABRICATED .090”
ALUM. CABINET
WHITE LED
.090” ALUM. STRIP
ELECTRICAL DETAIL
Scale: 1” = 1’-0”
24 LEDS @ 17.28W
ELECTRICAL SPECIFICATIONS:
(25) WHITE LED MODULES @ 1.5W EA= 37.5 W TOTAL
(1) 12V 60W POWER SUPPLIES @ 1.2 AMPS EA.
(1) CUSTOMER PROVIDED 120V/20A/60HZ
DEDICATED CIRCUIT REQUIRED
TOTAL CIRCUIT LOAD:
1.2 AMPS @ 120 VAC
Page 20 of 30
11
CONSTRUCTION MGR.
DIRECTOR
06-24-0008R3
SIGNS AND MENUS
ALL IDEAS, PLANS, AND ELECTRONIC
ART INDICATED ON THIS DRAWING ARE
COPYRIGHTED AND OWNED BY
FUSION SIGN AND DESIGN AND
SHALL NOT BE REPRODUCED, USED
BY OR DISCLOSED TO ANY PERSONS,
FIRM OR CORPORATION FOR ANY
PURPOSE WHATSOEVER WITHOUT
PERMISSION OF
FUSION SIGN AND DESIGN.
8306 El Camino Real
Atascadero, CA 93422
ADDRESS
DRAWING/REVISION NO.:
PAGE NO.:
OF
DUTCH BROS
CLIENT:
Approval Signature
06/18/2024
DATE:
Joanne P.
PROJECT MANAGER
Trong T.
DESIGNER:
11/14/2024
REVISION DATE:
Trong T.
REVISION BY:
12 226 Co as t Dr iv e
W hit ti er, CA 9 0601
()Tel:562 946-7545
()Fax: 562 949-5707
St. Lic.: 894662
Los Angeles, CA
www.fusionsign.com
20
8306
QTY. 1
SCOPE OF WORK: MANUFACTURE & INSTALL (1) NON-ILLUMINATED BUILDING ADDRESS
3’-0”
BUILDING ADDRESS
SCALE: 1 1/2"=1'-0"
ADDRESS NUMBERS:
FONT: ARIAL BOLD
MATERIAL: ¼” THICK ALUMINUM
COLOR: REFLECTIVE BLACK VINYL
INSTALLATION: STUD MOUNTED FLUSH TO BUILDING
1/4”
SIDE DETAIL
FULL SC ALE
¼” ALUMINUM FCO
ADDRESS NUMBER
THREADED STUD
COLOR CODE
Scale: 1 ½ = 1’-0”
ADDRESS NUMBERS
PAINTED BLACK W/ REFLECTIVE
BLACK VINYL OVERLAY
N6
Page 21 of 30
12
CONSTRUCTION MGR.
DIRECTOR
06-24-0008R3
SIGNS AND MENUS
ALL IDEAS, PLANS, AND ELECTRONIC
ART INDICATED ON THIS DRAWING ARE
COPYRIGHTED AND OWNED BY
FUSION SIGN AND DESIGN AND
SHALL NOT BE REPRODUCED, USED
BY OR DISCLOSED TO ANY PERSONS,
FIRM OR CORPORATION FOR ANY
PURPOSE WHATSOEVER WITHOUT
PERMISSION OF
FUSION SIGN AND DESIGN.
8306 El Camino Real
Atascadero, CA 93422
ADDRESS
DRAWING/REVISION NO.:
PAGE NO.:
OF
DUTCH BROS
CLIENT:
Approval Signature
06/18/2024
DATE:
Joanne P.
PROJECT MANAGER
Trong T.
DESIGNER:
11/14/2024
REVISION DATE:
Trong T.
REVISION BY:
12 226 Co as t Dr iv e
W hit ti er, CA 9 0601
( )Tel: 562 946-7545
( )Fax: 562 949-5707
St. Lic.: 894662
Los Angeles, CA
www.fusionsign.com
20
3’-0”
SCOPE OF WORK: MANUFACTURE & INSTALL (2) S/F POST MOUNTED MENU SIGN
Scale: 1” = 1’-0”
SIGN TYPE DBMENU-PM-SF: FREE STANDING MENU BOARD
TOTAL SQ. FT.: 10.7
3
ELECTRICAL SPECIFICATIONS:
(25) WHITE LED MODULES @ 1.5W EA= 37.5 W TOTAL
(1) 12V 60W POWER SUPPLIES @ 1.2 AMPS EA.
(1) CUSTOMER PROVIDED 120V/20A/60HZ
DEDICATED CIRCUIT REQUIRED
TOTAL CIRCUIT LOAD:
1.2 AMPS @ 120 VAC
ELECTRICAL DETAIL
Scale: 1” = 1’-0”
25 LEDS @ 37.5W
CONDUIT
(4) 5/8” Ø J-BOLTS 6” MIN.
EMBEDMENT INTO CONCRETE SIDE VIEWFRONT VIEW
3’-0” X 3’-0” X 10” DEEP
SPREAD FOOTING
W/ #4 @ REBAR 12” O.C.
EACH WAY
3’-0”10”5”QTY. 2N7
Page 22 of 30
13
CONSTRUCTION MGR.
DIRECTOR
06-24-0008R3
SIGNS AND MENUS
ALL IDEAS, PLANS, AND ELECTRONIC
ART INDICATED ON THIS DRAWING ARE
COPYRIGHTED AND OWNED BY
FUSION SIGN AND DESIGN AND
SHALL NOT BE REPRODUCED, USED
BY OR DISCLOSED TO ANY PERSONS,
FIRM OR CORPORATION FOR ANY
PURPOSE WHATSOEVER WITHOUT
PERMISSION OF
FUSION SIGN AND DESIGN.
8306 El Camino Real
Atascadero, CA 93422
ADDRESS
DRAWING/REVISION NO.:
PAGE NO.:
OF
DUTCH BROS
CLIENT:
Approval Signature
06/18/2024
DATE:
Joanne P.
PROJECT MANAGER
Trong T.
DESIGNER:
11/14/2024
REVISION DATE:
Trong T.
REVISION BY:
12 226 Co as t Dr iv e
W hit ti er, CA 9 0601
()Tel:562 946-7545
()Fax: 562 949-5707
St. Lic.: 894662
Los Angeles, CA
www.fusionsign.com
20
Page 23 of 30
14
CONSTRUCTION MGR.
DIRECTOR
06-24-0008R3
SIGNS AND MENUS
ALL IDEAS, PLANS, AND ELECTRONIC
ART INDICATED ON THIS DRAWING ARE
COPYRIGHTED AND OWNED BY
FUSION SIGN AND DESIGN AND
SHALL NOT BE REPRODUCED, USED
BY OR DISCLOSED TO ANY PERSONS,
FIRM OR CORPORATION FOR ANY
PURPOSE WHATSOEVER WITHOUT
PERMISSION OF
FUSION SIGN AND DESIGN.
8306 El Camino Real
Atascadero, CA 93422
ADDRESS
DRAWING/REVISION NO.:
PAGE NO.:
OF
DUTCH BROS
CLIENT:
Approval Signature
06/18/2024
DATE:
Joanne P.
PROJECT MANAGER
Trong T.
DESIGNER:
11/14/2024
REVISION DATE:
Trong T.
REVISION BY:
12 226 Co as t Dr iv e
W hit ti er, CA 9 0601
()Tel:562 946-7545
()Fax: 562 949-5707
St. Lic.: 894662
Los Angeles, CA
www.fusionsign.com
20
PLATE DETAIL
Scale: 3” = 1’-0”4”6”4”
6”
⅜” THICK. ALUM. PLATE
¾” Ø HOLE
CUT-OUT FOR 2” SQ. TUBE
2”X2” ALUM. TUBE
TYP.3/16”
6” X 6” X ⅜” ALUM. PLATE W/
(4) ⅝” Ø J-BOLTS 6” MIN.
EMBEDMENT INTO CONCRETE
SIDE B WHITE REFLECTIVE VINYL
Scale: 1 ½” = 1’-0”
SIGN TYPE DBDIR-DT-DF: NON-ILLUMINATED D/F DIRECTIONAL
TOTAL SQ. FT.: 3.13
2’-6”2”1’-3”3’-0”1’-9”SIDE A
SIDE VIEW2”6 ¼”
TOP VIEW
FABRICATED .090
ALUMINUM BOLT COVER
6 ¼”SCOPE OF WORK: MANUFACTURE & INSTALL (1) D/F NON-ILLUMINATED DIRECTIONAL SIGN
QTY. 1
2’-0”10”5”2’-0”10”5”N8
2”2”X2” ALUM.
TUBE
2”X2” ALUM. TUBE .090” ALUM. FACES
SECTION DETAILA
4 Scale: 1 ½” = 1’-0”
Scale: 1 ½” = 1’-0”
STRUCTURE DETAIL
2”X2” ALUM. TUBE
A
XX
1’-3”Scale: 1 ½” = 1’-0”
2”X2”X TUBE
P.T.M. PMS 541 C BLUE
2’-6”
Page 24 of 30
15
CONSTRUCTION MGR.
DIRECTOR
06-24-0008R3
SIGNS AND MENUS
ALL IDEAS, PLANS, AND ELECTRONIC
ART INDICATED ON THIS DRAWING ARE
COPYRIGHTED AND OWNED BY
FUSION SIGN AND DESIGN AND
SHALL NOT BE REPRODUCED, USED
BY OR DISCLOSED TO ANY PERSONS,
FIRM OR CORPORATION FOR ANY
PURPOSE WHATSOEVER WITHOUT
PERMISSION OF
FUSION SIGN AND DESIGN.
8306 El Camino Real
Atascadero, CA 93422
ADDRESS
DRAWING/REVISION NO.:
PAGE NO.:
OF
DUTCH BROS
CLIENT:
Approval Signature
06/18/2024
DATE:
Joanne P.
PROJECT MANAGER
Trong T.
DESIGNER:
11/14/2024
REVISION DATE:
Trong T.
REVISION BY:
12 226 Co as t Dr iv e
W hit ti er, CA 9 0601
()Tel:562 946-7545
()Fax: 562 949-5707
St. Lic.: 894662
Los Angeles, CA
www.fusionsign.com
20
Page 25 of 30
16
CONSTRUCTION MGR.
DIRECTOR
06-24-0008R3
SIGNS AND MENUS
ALL IDEAS, PLANS, AND ELECTRONIC
ART INDICATED ON THIS DRAWING ARE
COPYRIGHTED AND OWNED BY
FUSION SIGN AND DESIGN AND
SHALL NOT BE REPRODUCED, USED
BY OR DISCLOSED TO ANY PERSONS,
FIRM OR CORPORATION FOR ANY
PURPOSE WHATSOEVER WITHOUT
PERMISSION OF
FUSION SIGN AND DESIGN.
8306 El Camino Real
Atascadero, CA 93422
ADDRESS
DRAWING/REVISION NO.:
PAGE NO.:
OF
DUTCH BROS
CLIENT:
Approval Signature
06/18/2024
DATE:
Joanne P.
PROJECT MANAGER
Trong T.
DESIGNER:
11/14/2024
REVISION DATE:
Trong T.
REVISION BY:
12 226 Co as t Dr iv e
W hit ti er, CA 9 0601
()Tel:562 946-7545
()Fax: 562 949-5707
St. Lic.: 894662
Los Angeles, CA
www.fusionsign.com
20
SIDE A
SIDE B
2”2”X2” ALUM.
TUBE
2”X2” ALUM. TUBE .090” ALUM. FACES
SECTION DETAILA
4 Scale: 1 ½” = 1’-0”
WHITE REFLECTIVE VINYL
N9
Scale: 1 ½” = 1’-0”
SIGN TYPE DBDIR-EO-DF: NON-ILLUMINATED D/F DIRECTIONAL
TOTAL SQ. FT.: 3.13
SCOPE OF WORK: MANUFACTURE & INSTALL (1) D/F NON-ILLUMINATED DIRECTIONAL SIGN
2’-6”2”1’-3”3’-0”1’-9”SIDE A2”6 ¼”
TOP VIEW
FABRICATED .090
ALUMINUM BOLT COVER
Scale: 1 ½” = 1’-0”
PLATE DETAIL
Scale: 3” = 1’-0”
REFLECTIVE WHITE VINYL WITH DIGITALLY PRINTED BACKGROUND TO MATCH
DB CUSTOM DARK BLUE.
(SPECIAL PRODUCTION NOTE: GRAPHICS TO BE INSET FROM EDGE 1/8”).
2" X 2" SQUARE TUBE ALUMINUM FRAME & POST WITH ALUMINUM FACES & 1/4” X 6" X 6" PLATE.
FABRICATED .090 ALUMINUM BOLT COVER PAINT DB CUSTOM DARK BLUE.
INSTALL PLATE-MOUNTED.
PAD FOOTING INSTALLED BY GC.6 ¼”2”X2”X TUBE
P.T.M. PMS 541 C BLUE
REFLECTIVE WHITE VINYL
BORDER AND LETTERS
STRUCTURE DETAIL
2”X2” ALUM. TUBE
A
XX
1’-3”Scale: 1 ½” = 1’-0”
2”X2”X TUBE
P.T.M. PMS 541 C BLUE
2’-6”4”6”4”
6”
⅜” THICK. ALUM. PLATE
¾” Ø HOLE
CUT-OUT FOR 2” SQ. TUBE
2”X2” ALUM. TUBE
TYP.3/16”
6” X 6” X ⅜” ALUM. PLATE W/
(4) ⅝” Ø J-BOLTS 6” MIN.
EMBEDMENT INTO CONCRETE
2’-0”10”5”SIDE VIEW
2’-0”10”5”QTY. 1
Page 26 of 30
17
CONSTRUCTION MGR.
DIRECTOR
06-24-0008R3
SIGNS AND MENUS
ALL IDEAS, PLANS, AND ELECTRONIC
ART INDICATED ON THIS DRAWING ARE
COPYRIGHTED AND OWNED BY
FUSION SIGN AND DESIGN AND
SHALL NOT BE REPRODUCED, USED
BY OR DISCLOSED TO ANY PERSONS,
FIRM OR CORPORATION FOR ANY
PURPOSE WHATSOEVER WITHOUT
PERMISSION OF
FUSION SIGN AND DESIGN.
8306 El Camino Real
Atascadero, CA 93422
ADDRESS
DRAWING/REVISION NO.:
PAGE NO.:
OF
DUTCH BROS
CLIENT:
Approval Signature
06/18/2024
DATE:
Joanne P.
PROJECT MANAGER
Trong T.
DESIGNER:
11/14/2024
REVISION DATE:
Trong T.
REVISION BY:
12 226 Co as t Dr iv e
W hit ti er, CA 9 0601
()Tel:562 946-7545
()Fax: 562 949-5707
St. Lic.: 894662
Los Angeles, CA
www.fusionsign.com
20
Page 27 of 30
18
CONSTRUCTION MGR.
DIRECTOR
06-24-0008R3
SIGNS AND MENUS
ALL IDEAS, PLANS, AND ELECTRONIC
ART INDICATED ON THIS DRAWING ARE
COPYRIGHTED AND OWNED BY
FUSION SIGN AND DESIGN AND
SHALL NOT BE REPRODUCED, USED
BY OR DISCLOSED TO ANY PERSONS,
FIRM OR CORPORATION FOR ANY
PURPOSE WHATSOEVER WITHOUT
PERMISSION OF
FUSION SIGN AND DESIGN.
8306 El Camino Real
Atascadero, CA 93422
ADDRESS
DRAWING/REVISION NO.:
PAGE NO.:
OF
DUTCH BROS
CLIENT:
Approval Signature
06/18/2024
DATE:
Joanne P.
PROJECT MANAGER
Trong T.
DESIGNER:
11/14/2024
REVISION DATE:
Trong T.
REVISION BY:
12 226 Co as t Dr iv e
W hit ti er, CA 9 0601
()Tel:562 946-7545
()Fax: 562 949-5707
St. Lic.: 894662
Los Angeles, CA
www.fusionsign.com
20
1 ½” 74 ⅝”
66” 8”
EXISTING CABINET & RETAINERS
PAINTED BLACK
1 ¼” “H” DIVIDER BAR
PAINTED BLACK COLOR CODE
WHITE ACRYLIC
DB CUSTOM DARK BLUE
230-127 INTENSE BLUE PSV
230-33 RED PSV
230-015 YELLOW PSV
.177” WHITE ACRYLIC W/ 1st
SURFACE APPLY VINYL GRAPHICS
.177” WHITE ACRYLIC W/ 1st
SURFACE APPLY VINYL GRAPHICS
(COLORS MATCH TO BE PROVIDED)
EXISTING BASE TO REMAIN
68”
EXISTING CONDITION AS PROPOSED
Scale: 1/2” = 1’-0”
EXISTING MONUMENT SIGN REPLACEMENT FACES
AERIAL VIEW
N10
N13
20 ¾” 35” 36 ¼” 73 ¾” 36 ¼” QTY. 2
NOTE:
FABRICATE/INSTALL BY OTHERS
Page 28 of 30
19
CONSTRUCTION MGR.
DIRECTOR
06-24-0008R3
SIGNS AND MENUS
ALL IDEAS, PLANS, AND ELECTRONIC
ART INDICATED ON THIS DRAWING ARE
COPYRIGHTED AND OWNED BY
FUSION SIGN AND DESIGN AND
SHALL NOT BE REPRODUCED, USED
BY OR DISCLOSED TO ANY PERSONS,
FIRM OR CORPORATION FOR ANY
PURPOSE WHATSOEVER WITHOUT
PERMISSION OF
FUSION SIGN AND DESIGN.
8306 El Camino Real
Atascadero, CA 93422
ADDRESS
DRAWING/REVISION NO.:
PAGE NO.:
OF
DUTCH BROS
CLIENT:
Approval Signature
06/18/2024
DATE:
Joanne P.
PROJECT MANAGER
Trong T.
DESIGNER:
11/14/2024
REVISION DATE:
Trong T.
REVISION BY:
12 226 Co as t Dr iv e
W hit ti er, CA 9 0601
( )Tel: 562 946-7545
( )Fax: 562 949-5707
St. Lic.: 894662
Los Angeles, CA
www.fusionsign.com
20
FACES:............... CLEAR POLYCARBONATE FACE
W/ 2ND SURFACE VINYL GRAPHICS PER
COLOR SPECIFICATION
RETURNS:......... .090 ALUMINUM PAINTED - DB CUSTOM DARK BLUE
RETAINER:.......... 2”X2” RETAINER PAINTED - DB CUSTOM DARK BLUE
ILLUMINATION:.. WHITE LED’S
PYLON SIGN:
SPECIFICATIONS:
EXISTING CONDITION
AS PROPOSED
PYLON SIGN LOCATION
AERIAL VIEW 7’-9” V.O. 7’-11” V.O.
Scale: 3/8” = 1’-0”
EXISTING D/F PYLON SIGN W/ REPLACEMENT CABINETN11
N14
COLOR CODE
WHITE ACRYLIC
DB CUSTOM DARK BLUE
230-127 INTENSE BLUE PSV
230-33 RED PSV
230-015 YELLOW PSV
N11
QTY. 1
49’-0”
10”
16”
8’-2” CUT SIZE
8’-0” CUT SIZE 8’-3” 8’-1”Page 29 of 30
20
CONSTRUCTION MGR.
DIRECTOR
06-24-0008R3
SIGNS AND MENUS
ALL IDEAS, PLANS, AND ELECTRONIC
ART INDICATED ON THIS DRAWING ARE
COPYRIGHTED AND OWNED BY
FUSION SIGN AND DESIGN AND
SHALL NOT BE REPRODUCED, USED
BY OR DISCLOSED TO ANY PERSONS,
FIRM OR CORPORATION FOR ANY
PURPOSE WHATSOEVER WITHOUT
PERMISSION OF
FUSION SIGN AND DESIGN.
8306 El Camino Real
Atascadero, CA 93422
ADDRESS
DRAWING/REVISION NO.:
PAGE NO.:
OF
DUTCH BROS
CLIENT:
Approval Signature
06/18/2024
DATE:
Joanne P.
PROJECT MANAGER
Trong T.
DESIGNER:
11/14/2024
REVISION DATE:
Trong T.
REVISION BY:
12 226 Co as t Dr iv e
W hit ti er, CA 9 0601
( )Tel: 562 946-7545
( )Fax: 562 949-5707
St. Lic.: 894662
Los Angeles, CA
www.fusionsign.com
20
8-3”8’-1”1.) INSTALLATION OF THIS SIGN SHALL CONFORM TO THE REQUIREMENTS OF ARTICLE 600 OF NEC, UL48 AND/OR
OTHER APPLICABLE LOCAL CODES.
2.) BRANCH CIRCUIT:
A.) ALL BRANCH CIRCUITS FOR SIGNS MUST BE TOTALLY DEDICATED TO SIGNS (INCLUDING DEDICATED
GROUND AND DEDICATED NEUTRAL PER CIRCUIT).
B.) SIGN CIRCUITS MUST NOT BE SHARED WITH OTHER LOADS SUCH AS LIGHTING, AIR CONDITIONING AND
OTHER EQUIPMENT.
C.) PROPERTY SIZED GROUND WIRE THAT CAN BE TRACKED TO THE BREAKER PANEL MUST BE PROVIDED.
3.) U.L. AND DATA LABELS REQUIRED
4. ) SIGN SATISFIES ALL REQUIREMENTS OF TITLE 24.
5. ) OUTDOOR SIGNAGE TO EMPLOY EITHER PHOTOCELL OR OUTDOOR ASTRONOMICAL TIMER
GENERAL NOTES:
NOTES:
ELECTRICAL COMPONENTS TO BE UL LISTED
AND INSTALLED IN ACCORDANCE WITH THE
NATIONAL ELECTRIC CODE (NEC)
ALL WIRING SHALL BE 12 GA
(1) 20 AMP-120V CIRCUIT TO BE BROUGHT
TO JOB SITE BY LICENCED ELECTRICIAN.
ALL SIGNAGE WILL BE UL2161 COMPLIANT
AND CARRY UL LABELS.
THIS SIGN IS INTENDED TO BE
INSTALLED IN ACCORDANCE
WITH THE REQUIREMENTS OF
ARTICLE 600 OF THE NATIONAL
ELECTRICAL CODE AND/OR OTHER
APPLICABLE LOCAL CODES.
THIS INCLUDES PROPER GROUNDING
AND BONDING OF THE SIGN.
LISTED
ELECTRIC SIGN SECTION
ELECTRICAL SPECIFICATIONS:
TOTAL CIRCUIT LOAD:
2.4 AMPS @ 120 VAC
(42) LED RETROSTICKS MODULES @ 6.0W EA= 252W
TOTAL WATTS= 252W
(3) 24V 120W POWER SUPPLIES @ 2.4 AMPS EA.
42 MODULES TOTAL
60W POWER SUPPLY
ELECTRICAL
CUT-OFF SWITCH
13”
POWER SUPPLY
LED LAYOUT
Scale: 3/4” = 1’-0”
Page 30 of 30