HomeMy WebLinkAboutResolution 32-90 RESOLUTION NO. 32-90
RESOLUTION OF THE COUNCIL OF THE CITY OF ATASCADERO
ESTABLISHING A SEWER LATERAL STANDARD
FOR THE
INSTALLATION OF SANITARY SEWER LATERALS
WHEREAS, there is no existing sanitary sewer lateral
standard for the City of Atascadero; and
WHEREAS, the installation of sewer laterals is a common
activity within the City; and
WHEREAS, information regarding sewer lateral installation
standards is frequently requested by the public; and
WHEREAS, information regarding sewer lateral installation
standards is frequently used by the City staff in reviewing
construction plans.
NOW, THEREFORE, BE IT RESOLVED THAT:
The installation standard for sewer laterals shall be as
delineated on the attached drawing S-2 titled "Sewer Lateral. "
The City Engineer is hereby authorized to make minor adjustments
to this Standard to accommodate changing materials
specifications and construction conditions.
On motion by Councilperson Lilley , seconded by
Councilperson Mackey , the foregoing resolution is passed on
the following roll call vote:
AYES: Councilmembers Shiers, Borgeson, Mackey, Lilley and Mayor Dexter
NOES: None
ABSENT: None
ADOPTED: 3/27/90
ATTEST 6(�
----
LEE DAYKA, City Cl rk R N DEXTER, Mayor
APPROVED AS TO FORM: APPROVED AS TO CONTENT:
ART R M NTAN N HE RY ENG
City Attorney Director o Commity
Development
(ATTACHMENT TO RES. 32-90)
Revisions Approvals
Descriptions By Date Approved Council Resolution No.
GUTTER LIP PROPERTY LINE
GUTTER FLOW LINE BACK OF CURB
WATERPROOF
1/8 BEND (45') BACK OF SIDEWALK STOPPER &
4" MIN DIA. SEAL
VARIES
-- N --- -- ------ 0
4" MIN. DIA.
SEWER LATERAL SIDEWALK 12"
PLACE REDWOOD
WYE OR TEE GRAPE STAKE
SEWER MAIN VARIES �' AT END OF
LATERAL
SEWER MAIN PLAN
EAEN ROACHMENT PERMIT ANDPROPERTY LINE
ARE REQUIRED FOR SEWERD INSTALLATION.
pee ---------y.•o.p. ..p••?.o;•Y.
r G°9�ife�•ri .s, D •'p a �'Gt�tr3'�[J���
CURB & GUTTER z
NOTE:
z �
LATERAL SHALL BE CAST IRON PIPE x M 12„
OR PVC PIPE ENCASED IN CONCRETE M MIN LATERAL SIZE: 4" DIA. i
WHEN THE COVER IS LESS THAN 36" MIN SLOPE 1/4" PER FOOT 7
OVER THE TOP OF PIPE. OTHERWISE, / PLACEREDWOOD
LATERAL SHALL BE SDR 35 PVC. r GRAPE STAKE AT
TEE END OF LATERAL.
OR WYE
-*-----1/8 BEND (45•) SECTION
NOTES: INSTALL
I. S" SHALL BE MARKED ON CURB OVER LATERAL. WATERTIGHT SEAL
2. THE "S" SHALL BE STAMPED INTO NEW CONCRETE
SEWER MAIN IF NOT CONNECTED
AND SHALL BE CHISELED INTO EXISTING CONCRETE. TO BUILDING SEWER.
3. THE "S" SHALL BE NOT LESS THAN 3" HIGH, 2" WIDE
AND 3/16" DEEP.
4. MAINTAIN MINIMUM 5' HORIZONTAL SEPARATION FROM
WATER SERVICE.
5. INSTALL MAGNETIC TAPE AT A DEPTH OF 24"-32", THEN
UP TO SURFACE.
6. INSTALL TRENCH ACCORDING TO STANDARD TRENCH DETAIL, S-1.
SCALE
CITY OF ATASCADERO NO SCALE
ENGINEERING DIVISION DRAWNG NO.
s
ptkgCADSRa SEWER LATERAL S-2