Loading...
HomeMy WebLinkAboutResolution 32-90 RESOLUTION NO. 32-90 RESOLUTION OF THE COUNCIL OF THE CITY OF ATASCADERO ESTABLISHING A SEWER LATERAL STANDARD FOR THE INSTALLATION OF SANITARY SEWER LATERALS WHEREAS, there is no existing sanitary sewer lateral standard for the City of Atascadero; and WHEREAS, the installation of sewer laterals is a common activity within the City; and WHEREAS, information regarding sewer lateral installation standards is frequently requested by the public; and WHEREAS, information regarding sewer lateral installation standards is frequently used by the City staff in reviewing construction plans. NOW, THEREFORE, BE IT RESOLVED THAT: The installation standard for sewer laterals shall be as delineated on the attached drawing S-2 titled "Sewer Lateral. " The City Engineer is hereby authorized to make minor adjustments to this Standard to accommodate changing materials specifications and construction conditions. On motion by Councilperson Lilley , seconded by Councilperson Mackey , the foregoing resolution is passed on the following roll call vote: AYES: Councilmembers Shiers, Borgeson, Mackey, Lilley and Mayor Dexter NOES: None ABSENT: None ADOPTED: 3/27/90 ATTEST 6(� ---- LEE DAYKA, City Cl rk R N DEXTER, Mayor APPROVED AS TO FORM: APPROVED AS TO CONTENT: ART R M NTAN N HE RY ENG City Attorney Director o Commity Development (ATTACHMENT TO RES. 32-90) Revisions Approvals Descriptions By Date Approved Council Resolution No. GUTTER LIP PROPERTY LINE GUTTER FLOW LINE BACK OF CURB WATERPROOF 1/8 BEND (45') BACK OF SIDEWALK STOPPER & 4" MIN DIA. SEAL VARIES -- N --- -- ------ 0 4" MIN. DIA. SEWER LATERAL SIDEWALK 12" PLACE REDWOOD WYE OR TEE GRAPE STAKE SEWER MAIN VARIES �' AT END OF LATERAL SEWER MAIN PLAN EAEN ROACHMENT PERMIT ANDPROPERTY LINE ARE REQUIRED FOR SEWERD INSTALLATION. pee ---------y.•o.p. ..p••?.o;•Y. r G°9�ife�•ri .s, D •'p a �'Gt�tr3'�[J��� CURB & GUTTER z NOTE: z � LATERAL SHALL BE CAST IRON PIPE x M 12„ OR PVC PIPE ENCASED IN CONCRETE M MIN LATERAL SIZE: 4" DIA. i WHEN THE COVER IS LESS THAN 36" MIN SLOPE 1/4" PER FOOT 7 OVER THE TOP OF PIPE. OTHERWISE, / PLACEREDWOOD LATERAL SHALL BE SDR 35 PVC. r GRAPE STAKE AT TEE END OF LATERAL. OR WYE -*-----1/8 BEND (45•) SECTION NOTES: INSTALL I. S" SHALL BE MARKED ON CURB OVER LATERAL. WATERTIGHT SEAL 2. THE "S" SHALL BE STAMPED INTO NEW CONCRETE SEWER MAIN IF NOT CONNECTED AND SHALL BE CHISELED INTO EXISTING CONCRETE. TO BUILDING SEWER. 3. THE "S" SHALL BE NOT LESS THAN 3" HIGH, 2" WIDE AND 3/16" DEEP. 4. MAINTAIN MINIMUM 5' HORIZONTAL SEPARATION FROM WATER SERVICE. 5. INSTALL MAGNETIC TAPE AT A DEPTH OF 24"-32", THEN UP TO SURFACE. 6. INSTALL TRENCH ACCORDING TO STANDARD TRENCH DETAIL, S-1. SCALE CITY OF ATASCADERO NO SCALE ENGINEERING DIVISION DRAWNG NO. s ptkgCADSRa SEWER LATERAL S-2